Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    12 VOLT 1000 AMP TRANSFORMER Search Results

    12 VOLT 1000 AMP TRANSFORMER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    WB1040-SML Coilcraft Inc Transformer Visit Coilcraft Inc
    AS8426-A Coilcraft Inc Telecom Transformer Visit Coilcraft Inc Buy
    B0727-B Coilcraft Inc Telecom Transformer Visit Coilcraft Inc Buy
    AS8954-A Coilcraft Inc Telecom Transformer Visit Coilcraft Inc
    CR7984-CLD Coilcraft Inc Datacom Transformer Visit Coilcraft Inc

    12 VOLT 1000 AMP TRANSFORMER Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: nt SECTION 7 Mains 50/60Hz Current Transformers • Primary Current Ratings to 200 Amps • 20kHz to 200kHz Current Sense Inductors and Transformers • Fully RoHS Compliant • magnetics nuvotem Current Sense Transformers and Inductors Sales & Marketing, Design and Manufacturing Facilities


    Original
    PDF 50/60Hz 20kHz 200kHz

    12 volt 10 amp transformer

    Abstract: 100-01A northern design IEC1010-1 Northern Design Electronics Transformer 120 volt to 50 volt
    Text: Northern Design Clamp-on Current Transformer MODEL US 1000A:1A Electricity Metering & Monitoring SPECIFICATION Nominal Input Current In Maximum Input Current Measurement Range Output Signal Ratio Typical Accuracy Maximum Error 1000 Amp continuous 1200 Amp


    Original
    PDF 5000Hz IEC1010-1 2000m 1000-1a 12 volt 10 amp transformer 100-01A northern design IEC1010-1 Northern Design Electronics Transformer 120 volt to 50 volt

    radikor board

    Abstract: talema ac1015 radikor talema ASM-050 50A AC current sensor 50V Center Tapped 5 Amp Transformer ASM-020 ASM-030 Signal Line Filters CH-8902 ASM-010
    Text: Current Sense Transformers and Inductors Design and Manufacturing Facilities http://www.talema-nuvotem.com Czech Republic Germany Ireland India TALEMA ELECTRONIC s.r.o. Jablonského 7 301 45 Plzeñ Tel: Int. + 420 19 - 744 9303 Fax: Int. + 420 19 - 744 3697


    Original
    PDF 50/60Hz 20kHz 200kHz. radikor board talema ac1015 radikor talema ASM-050 50A AC current sensor 50V Center Tapped 5 Amp Transformer ASM-020 ASM-030 Signal Line Filters CH-8902 ASM-010

    talema ac1015

    Abstract: 50V Center Tapped 5 Amp Transformer AC1025 AC1015 CURRENT TRANSFORMER ma 3810 AC1150 Ac1010 ac1020 AC1005
    Text: AC Series • Current Transformer Quick Reference Guide Low Cost 50/60Hz Current Transformers Applications • Sensing Overload Current • Ground fault detection • Metering • Analog to Digital Circuits Features • Excellent quality at extremely competetive price due to high


    Original
    PDF 50/60Hz ISO-9001 AC1200) AC1200 200mA talema ac1015 50V Center Tapped 5 Amp Transformer AC1025 AC1015 CURRENT TRANSFORMER ma 3810 AC1150 Ac1010 ac1020 AC1005

    AC1040

    Abstract: AC1050
    Text: AC1040 • 40 Amp Current Transformer Low Cost 50/60Hz Current Transformers Applications • Sensing Overload Current • Ground fault detection • Metering • Analog to Digital Circuits Electrical Specifications @ 20°C ambient E lectrical S p ecificatio n s


    Original
    PDF AC1040 50/60Hz UL94-VO AC1040, AC1040) AC1040 AC1050

    isolation transformer 50 kVA

    Abstract: 240D10 Transformer 500 volt to 60 volt application of mp240d4 with circuit diagram reversing ssr 240A45 120A25 120D10 120D3 120D45
    Text: Solid-State Relays Features Overview In 1974, Opto 22 introduced the first liquid epoxy-filled line of power solid-state relays SSR . This innovation in SSR design greatly improved the reliability and reduced the cost of manufacturing. At that time, we also incorporated into our manufacturing process


    Original
    PDF 25-Amp 10-Amp Z240D25 Z240D10 240D10 240A10 240D25 240A25 240D45 isolation transformer 50 kVA 240D10 Transformer 500 volt to 60 volt application of mp240d4 with circuit diagram reversing ssr 240A45 120A25 120D10 120D3 120D45

    12 volt 10 amp transformer

    Abstract: solenoid contactor 120A10 120A25 120D10 120D25 120D3 120D45 240A10 240A25
    Text: Solid-State Relays Features Overview In 1974, Opto 22 introduced the first liquid epoxy-filled line of power solid-state relays SSR . This innovation in SSR design greatly improved the reliability and reduced the cost of manufacturing. At that time, we also incorporated into our manufacturing process


    Original
    PDF MP240D2 240D25 120A25 240D45 10-Amp 25-Amp 45-Amp 12 volt 10 amp transformer solenoid contactor 120A10 120A25 120D10 120D25 120D3 120D45 240A10 240A25

    solenoid contactor

    Abstract: 120-volt Ideal make ssr OPTO 22 model mp120d4 120A25 120D10 MP120D4 120D3 120D45 240A25
    Text: Solid-State Relays Features Overview In 1974, Opto 22 introduced the first liquid epoxy-filled line of power solid-state relays SSR . This innovation in SSR design greatly improved the reliability and reduced the cost of manufacturing. At that time, we also incorporated into our manufacturing process


    Original
    PDF MP240D2 240D25 120A25 240D45 10-Amp 25-Amp 45-Amp solenoid contactor 120-volt Ideal make ssr OPTO 22 model mp120d4 120A25 120D10 MP120D4 120D3 120D45 240A25

    OPTO 22 - 480D45-12

    Abstract: Z240D25 480D10-12 1000 watt power amp circuit diagram 120A25 120D10 120D25 120D3 120D45 240A25
    Text: Solid-State Relays Features Overview In 1974, Opto 22 introduced the first liquid epoxy-filled line of power solid-state relays SSR . This innovation in SSR design greatly improved the reliability and reduced the cost of manufacturing. At that time, we also incorporated into our manufacturing process


    Original
    PDF 25-Amp 10-Amp Z240D25 Z240D10 240D10 240A10 240D25 240A25 240D45 OPTO 22 - 480D45-12 Z240D25 480D10-12 1000 watt power amp circuit diagram 120A25 120D10 120D25 120D3 120D45 240A25

    OPTO 22 model p240d2

    Abstract: transformer 9-0-9 relay 12 volt tip 1200 1 amps 100 Amp current 1000 volt diode 480V motor operated valve scr 300 amps model 380D25 P240D4 12 volt 10 amp relay
    Text: SOLID-STATE RELAYS DATA SHEET page 1/12 Form 859-990514 Overview In 1974, Opto 22 introduced the first liquid epoxy-filled line of power solid-state relays SSR . This innovation in SSR design greatly improved the reliability and reduced the cost of manufacturing. At that time, we also incorporated


    Original
    PDF 25-Amp 480D10-12 45-Amp 16-Amp 480D15-12 15-Amp 321-OPTO opto22 452-OPTO OPTO 22 model p240d2 transformer 9-0-9 relay 12 volt tip 1200 1 amps 100 Amp current 1000 volt diode 480V motor operated valve scr 300 amps model 380D25 P240D4 12 volt 10 amp relay

    isolation transformer 50 kVA

    Abstract: 12 volt 10 amp transformer Z120D10 Z240D10 solenoid contactor 7240D10 MP240D2 120A25 120D3 120D45
    Text: Solid-State Relays Features Overview In 1974, Opto 22 introduced the first liquid epoxy-filled line of power solid-state relays SSR . This innovation in SSR design greatly improved the reliability and reduced the cost of manufacturing. At that time, we also incorporated into our manufacturing process


    Original
    PDF MP240D2 240D25 120A25 240D45 10-Amp 25-Amp 45-Amp isolation transformer 50 kVA 12 volt 10 amp transformer Z120D10 Z240D10 solenoid contactor 7240D10 MP240D2 120A25 120D3 120D45

    MP380D4

    Abstract: OPTO 22 model mp120d4 P240D4 rectifier diode 20 amp 800 volt what is relay 9 volt 150 ohm 380D25 DC200MP Opto scr 10amp 1000 Volt diode 120A10
    Text: Solid-State Relays Features Opto 22 Power Series SSR Description Overview In 1974, Opto 22 introduced the first liquid epoxy-filled line of power solid-state relays SSR . This innovation in SSR design greatly improved the reliability and reduced the cost of manufacturing. At


    Original
    PDF opto22 MP380D4 OPTO 22 model mp120d4 P240D4 rectifier diode 20 amp 800 volt what is relay 9 volt 150 ohm 380D25 DC200MP Opto scr 10amp 1000 Volt diode 120A10

    transformer 9-0-9

    Abstract: scr RC snubber design MP240D4 opto 120d10 TRANSFORMER 9- 0-9 1.5amp DC200MP opto scr P240D4 480V motor operated valve DC60MP
    Text: SOLID-STATE RELAYS DATA SHEET page 1/14 Form 859-030604 Overview In 1974, Opto 22 introduced the first liquid epoxy-filled line of power solid-state relays SSR . This innovation in SSR design greatly improved the reliability and reduced the cost of manufacturing. At that time, we also incorporated into our


    Original
    PDF 321-OPTO opto22 452-OPTO 474-OPTO 474-OPTO. transformer 9-0-9 scr RC snubber design MP240D4 opto 120d10 TRANSFORMER 9- 0-9 1.5amp DC200MP opto scr P240D4 480V motor operated valve DC60MP

    12 VOLT 50 AMP smps schematics

    Abstract: PE-51718 35 VOLT 3 AMP smps schematics PE-65300 layout 48 VOLT 150 AMP smps PE-64973 flyback transformer THT pin connections offline switcher P0584 transformer 12 volt 150 amp smps
    Text: TABLE of CONTENTS Gate Drive Transformers DC/DC Surface Mount Gate Drives for SELV Operation . . . . . . . . . . . . . . . . . . . . .2-3 UL/C-UL Recognized Through Hole Gate Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 500 KHz Gate Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5


    Original
    PDF 500/reel 40/tube PE-682XX PC502 12 VOLT 50 AMP smps schematics PE-51718 35 VOLT 3 AMP smps schematics PE-65300 layout 48 VOLT 150 AMP smps PE-64973 flyback transformer THT pin connections offline switcher P0584 transformer 12 volt 150 amp smps

    Untitled

    Abstract: No abstract text available
    Text: Power Management Group RADIATION HARDENED ISOLATED DC/DC CONVERTERS SA50-120-5/15T 50 Watts Total Power +5Vdc±15Vdc Triple Output Microsemi Power Management Group PMG multiple decades of fault free heritage complex custom (radiation hardened) switching power design and systems


    Original
    PDF SA50-120-5/15T 15Vdc 100kRad SA50-120-5-15T

    opto 22 240d25

    Abstract: simple 10watt led circuit diagram DC60MP P240D4 12 volt 25 amp scr power supply 240D25 480D10-12 DC200MP 120A10 120A25
    Text: Solid-State Relays Features Opto 22 Power Series SSR Description Overview In 1974, Opto 22 introduced the first liquid epoxy-filled line of power solid-state relays SSR . This innovation in SSR design greatly improved the reliability and reduced the cost of manufacturing. At


    Original
    PDF opto22 opto 22 240d25 simple 10watt led circuit diagram DC60MP P240D4 12 volt 25 amp scr power supply 240D25 480D10-12 DC200MP 120A10 120A25

    Untitled

    Abstract: No abstract text available
    Text: LOW VOLTAGE LIGHTING TRANSFORM ERS & POWER SU PPLIES <§- Lo w Voltage General Purpose Transformers Features • Flexible copper leadwire terminations. • UL listed . CSA Certified. • 100,150, 300,600, 750,1000 VA. • UL class 180°C insulation system


    OCR Scan
    PDF T-1-79615-S T-1-79630-S T-1-79631-S T-1-79618-S T-1-79619-S

    Untitled

    Abstract: No abstract text available
    Text: gflM ECDN ^ 50A CURRENT TRANSFORMER, P/N 5308 THE ENERGY SAVER FOR 23 YEARS ELECTRICAL SPECIFICATIONS 50 A NOM. 125A MAX. 1000:1 NOMINAL 0 .1 0 0 V /A 0 .0 9 8 V /A 46 OHMS 4kV RMS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 50 A, FOR 100 OHM LOAD:


    OCR Scan
    PDF 025IN

    Untitled

    Abstract: No abstract text available
    Text: gflM ECDN ^71 40A CURRENT TRANSFORMER, P/N 5307 THE ENERGY SAVER FOR 23 YEARS ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 40 A, FOR 100 OHM LOAD: VOLT PER AMP RATIO AT 4 .0 A, FOR 100 OHM LOAD: D.C.RESISTANCE AT 20'C DIELECTRIC WITHSTANDING VOLTAGE:


    OCR Scan
    PDF 025IN

    Untitled

    Abstract: No abstract text available
    Text: SECTION i UJW VOUAGE LIGHTING TRANSFORMERS & POWER >;,J Low Voltage General Purpose Transformers_ @ Features • • • • • • • • • UL Listed, CSA Certified. 100,150, 300, 600,750,1000 VA 1 Phase, 60 Hz, 120 or 240 volt input. 12 or 24 volt output.


    OCR Scan
    PDF

    Untitled

    Abstract: No abstract text available
    Text: gfiM ECON • ^ 5A CURRENT TRANSFORMER, P /N 5301 THE ENERGY SAVER FOR 23 YEARS 71^ ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 5 A, FOR 100 OHM LOAD : VOLT PER AMP RATIO AT .5 A, FOR 100 OHM LOAD : D.C.RESISTANCE AT 20‘ C :


    OCR Scan
    PDF 025IN

    Amecon 5304

    Abstract: 5304 transformer
    Text: gflMECDN 20A CURRENT TRANSFORMER, P/N 5304 THE ENERGY SAVER FOR 2 3 YEARS 0 .3 5 5 ELECTRICAL SPECIFICATIONS 20A NOM., 60A MAX. 1000:1 NOMINAL 0 .1 0 0 V /A 0 .0 9 7 V /A 39 OHMS 4kV RMS. PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 2 0 A, FOR 100 OHM LO AD:


    OCR Scan
    PDF 025IN Amecon 5304 5304 transformer

    transformateurs

    Abstract: FIS130 FIS151 pour
    Text: Pulse* FEE FIS Series A T E C H N I T R O L C O M P A N Y Current Sense Transformers Transformateurs de courant K ey Features Caractéristiques Current sense transformers, as feedback elements linking the output and pulse control circuitry, a llo w low-cost regulation


    OCR Scan
    PDF PF500 transformateurs FIS130 FIS151 pour

    2M248

    Abstract: 10 pin flyback transformer schematics 0071 em 483 12 VOLT 50 AMP smps schematics PE-68411 12 VOLT 16 AMP smps schematics PE-65300 35 VOLT 3 AMP smps schematics transformer for lm2577 jh-45
    Text: TRANSFORMERS POWER MAGNETICS Pulse A TECHNITROL COMPANY TABLE of C O N T E N T S PG F Pow er Transform ers High Power, Low Profile, High Frequency. 1 G ate D riv e Transform ers MOSFET Gate D


    OCR Scan
    PDF PC502 2M248 10 pin flyback transformer schematics 0071 em 483 12 VOLT 50 AMP smps schematics PE-68411 12 VOLT 16 AMP smps schematics PE-65300 35 VOLT 3 AMP smps schematics transformer for lm2577 jh-45