77206
Abstract: 77208C 77205C 77209C 77-20-2C 77205
Text: 772 Series POWER ELECTRONICS DIVISION Pulse Transformers SELECTION GUIDE Primary Inductance Min. 1.0 1.0 1.0 1.0 4.0 4.0 4.0 Primary Et Constant (Min.) 120 120 120 120 240 240 n Up to 482 V s Et rating Leakage Inductance (Max.) 2.0 3.0 3.5 3.5 5.0 n PCB mounting
|
Original
|
PDF
|
4000Vrms
77206
77208C
77205C
77209C
77-20-2C
77205
|
TA-83215
Abstract: TA-83224 TA-83315 TA-83213 PL-112705 TA-83210 TA-83222 TA-83219 PL-11270 PL-112700
Text: SECTION V INDUSTRIAL CONTROL TRANSFORMERS GROUP J 240 X 480 PRIMARY VOLTS — 120/240 SECONDARY VOLTS — 1Ø, 60 Hz CATALOG NO. VA RATING OUTPUT AMPS TA-83210 50 0.42 TA-83212 100 0.83 TA-83213 150 1.25 TA-83215 250 2.08 TA-83218 500 4.17 TA-83219 750 6.25
|
Original
|
PDF
|
TA-83210
TA-83212
TA-83213
TA-83215
TA-83218
TA-83219
TA-83220
TA-83221
TA-83222
TA-83223
TA-83215
TA-83224
TA-83315
TA-83213
PL-112705
TA-83210
TA-83222
TA-83219
PL-11270
PL-112700
|
220 ac INVERTER without transformer
Abstract: 220v to 110v INVERTER without transformer 220v AC to 110v AC transformer circuit diagram an AND8005 220v AC to 110v AC transformer circuit diagram high voltage transformer 100 kW 1N5349 2N2222 220 110 transformer 2N2222 circuit
Text: AND8005/D Automatic AC Line Voltage Selector http://onsemi.com APPLICATION NOTE INTRODUCTION In some cases, appliances and equipment are able to operate when supplied by two different levels of AC line voltage to their main terminals 120 V or 240 V . This is
|
Original
|
PDF
|
AND8005/D
220 ac INVERTER without transformer
220v to 110v INVERTER without transformer
220v AC to 110v AC transformer circuit diagram an
AND8005
220v AC to 110v AC transformer circuit diagram
high voltage transformer 100 kW
1N5349
2N2222
220 110 transformer
2N2222 circuit
|
c3194
Abstract: transistor c3194 5B35-04 5B35 5B35-01 5B35-02 5B35-03 5B35-05 5B35-C-01 5B35-C-02
Text: a FEATURES Accepts a Variety of RTD Types 100 ⍀ Platinum, 10 ⍀ Copper, 120 ⍀ Nickel Linearizes RTD Signal 1500 V rms Input/Output and Input/Power Isolation 250 V rms Output/Power Isolation 240 V rms Field Wiring Protection 4-Wire Lead Resistance Compensation
|
Original
|
PDF
|
01C/C
5B35-04
c3194
transistor c3194
5B35
5B35-01
5B35-02
5B35-03
5B35-05
5B35-C-01
5B35-C-02
|
PHE-7351-15
Abstract: No abstract text available
Text: INDUSTRIAL PH INSTRUMENTATION & ELECTRONICS Mini Panel-Mount pH Controller Model PHCN-201 $ 120 Basic Unit ߜ ߜ ߜ ߜ User-Selectable Acid or Alkaline Relay Simple One-Point Calibration Reduced Size to Facilitate Installation Choose from 100-240 V or Low Voltage
|
Original
|
PDF
|
PHCN-201
PHCN-201
PHCN-201,
PHE-7351-15,
PHE-7351-15
|
32901A
Abstract: 32212a 32048A 32205A 32012B 32012a 32005E 32024D 32005B Calex
Text: 32000 Series Open Frame AC/DC Regulated Linear Power Supplies General Specifications A.C. Input D.C. Output Line Regulation Load Regulation Output Ripple 100/120/220/240 V AC +10%, -12%, 47 to 60 Hz See Voltage/Current Rating Chart. Adjustment range ±5% minimum.
|
Original
|
PDF
|
2901A
32901B
32901A
32212a
32048A
32205A
32012B
32012a
32005E
32024D
32005B
Calex
|
SMD diode sg 46
Abstract: 1n4148 zener diode SG 46 a DIODE SMD RK73H1JT1001F WECO filter C3216X7R2J223KT0L0U Y2 diode SG 21 DIODE SMD cl31b zener diode 15v
Text: PRELIMINARY PFM V•I Chip PFM Power Factor Module • • • • • • • • • F3D480T20A DC+ Input: rectified 120/240 Vac sinusoidal Output: 48 Vdc programmable Output power: Up to 200 W 4,242 Vdc reinforced insulation 90% efficiency 375 W/in3 power density
|
Original
|
PDF
|
F3D480T20A
SMD diode sg 46
1n4148 zener diode
SG 46 a DIODE SMD
RK73H1JT1001F
WECO filter
C3216X7R2J223KT0L0U
Y2 diode
SG 21 DIODE SMD
cl31b
zener diode 15v
|
PFC buck converter design
Abstract: 1N4148 SMD PACKAGE 3 phase bridge fully controlled rectifier 1206 smd 100 ohm resistor sc 6200 Ferrite Bead TDK SMD diode sg 46 SG 21 DIODE SMD 1n4148 zener diode buck converter vout 100v
Text: PRELIMINARY PFM V•I Chip PFM Power Factor Module • • • • • • • • • F3D480T20A DC+ Input: rectified 120/240 Vac sinusoidal Output: 48 Vdc programmable Output power: Up to 200 W 4,242 Vdc reinforced insulation 90% efficiency 375 W/in3 power density
|
Original
|
PDF
|
F3D480T20A
PFC buck converter design
1N4148 SMD PACKAGE
3 phase bridge fully controlled rectifier
1206 smd 100 ohm resistor
sc 6200
Ferrite Bead TDK
SMD diode sg 46
SG 21 DIODE SMD
1n4148 zener diode
buck converter vout 100v
|
convert select 120
Abstract: 1740-6M1 1240-6M1 chloride systems 48v charger LWN2660-6 24V battery charger 12406M1 7213 BATTERY CHARGER ACID
Text: DIN-Rail Mountable AC-DC Converters 125, 250 Watt AC-DC Converters W Series Convert Select 120, 240 Rugged 35 mm DIN-rail snap-fit design Class I equipment Single or double outputs for 24 or 48 V DC loads • Universal AC-input with single stage conversion
|
Original
|
PDF
|
22/EN
convert select 120
1740-6M1
1240-6M1
chloride systems 48v charger
LWN2660-6
24V battery charger
12406M1
7213
BATTERY CHARGER ACID
|
convert select 120
Abstract: 1740-6M1 convert select 240 Battery Chargers planar Transformer circuit
Text: W Series Extended Data Sheet 125, 250 Watt AC-DC DC-DC - Convert Select 120, 240 Rugged 35 mm DIN-rail snap-fit design Class I equipment Single or double outputs for 24 or 48 V DC loads • Universal AC-input with single stage conversion AC to DC with PFC, DC input 90 to 275 V
|
Original
|
PDF
|
22/EN
89/336/EEC
convert select 120
1740-6M1
convert select 240
Battery Chargers planar Transformer circuit
|
TA-2-81214
Abstract: TA-2-81217 TA-2-81007 TA-2-81216 TA-2-81005 PL-112601 TA-2-81215 TA-2-81220 TA-2-81221 TA-2-81200
Text: SECTION V GROUP B INDUSTRIAL CONTROL TRANSFORMERS CONTINUED 240 X 480, 230 X 460, 220 X 440 PRIMARY VOLTS — 120/115/110 SECONDARY VOLTS — 1Ø, 50/60 Hz CATALOG NO. 2 VA OUTPUT RATING AMPS TA-2-81200 2 300 2.50 TA-2-81214 2 350 2.92 TA-2-81215 2 500 4.17
|
Original
|
PDF
|
TA-2-81200
TA-2-81214
TA-2-81215
TA-2-81216
TA-2-81217
TA-2-81218
TA-2-81219
TA-2-81220
TA-2-81221
PL-112700
TA-2-81007
TA-2-81005
PL-112601
TA-2-81220
TA-2-81221
|
FS-2-2000
Abstract: FS115 PL-79905 PL-79906 by 550-208 PL-79908 FS-2-1000 FS1500 FS-2-250 FS250
Text: SECTION V FINGER/GUARD INDUSTRIAL CONTROL TRANSFORMERS SELECTION CHARTS GROUP A 120 X 240 PRIMARY VOLTS — 24 SECONDARY VOLTS — 50/60 Hz CATALOG NO. FS-1-50 FS-1-75 FS-1-100 FS-1-150 FS-1-250 FS-1-350 FS-1-500 FS-1-750 FS-1-1000 VA RATING 50 75 100 150
|
Original
|
PDF
|
FS-1-50
FS-1-75
FS-1-100
FS-1-150
FS-1-250
FS-1-350
FS-1-500
FS-1-750
FS-1-1000
PL-79905
FS-2-2000
FS115
PL-79905
PL-79906
by 550-208
PL-79908
FS-2-1000
FS1500
FS-2-250
FS250
|
single phase transformer
Abstract: M6020-9Y m60205 M6020-18PS M6020-2S M6020-27Y m601 M6020E-12Y M6020-8PS 6020CT-2S
Text: Variable Transformers Series 6000 l 35.0 to 315.0 Amperes 5000/6000 Series Manual Single, Uncased Two Ganged 17.06” [433.3] 13.56” [344.4] 15.12” [384.2] A B C Three Ganged 23.12” [587.4] 19.62” [498.3] 21.19” [538.2] Manual Two and Three-Ganged, Uncased
|
Original
|
PDF
|
|
M50119P
Abstract: M50115P m50115 M50117P M5011 5011-6Y 5021E-6P M5021-9Y 5021CT M50118P
Text: Variable Transformers Series 5000 l 28.0 to 252.0 Amperes 5000 Series The 5011/5021 Series Variable transformers are designed to control large KVA requirements. The 5011 operates on 120 volts and is rated for constant current of 50 amperes. The 5021 operates on 240 volts and constant current of 28 amperes. The
|
Original
|
PDF
|
27-Ganged,
18-Ganged
60M5021-27Y
M50119P
M50115P
m50115
M50117P
M5011
5011-6Y
5021E-6P
M5021-9Y
5021CT
M50118P
|
|
transformer 24-0-24
Abstract: No abstract text available
Text: 6 Buck–Boost Transformers Buck-Boost transformers are small, single phase, dry type distribution transformers designed and shipped as insulating/isolating transformers. They have a dual voltage primary and a dual voltage secondary. These transformers can be connected for a wide range of voltage combinations.
|
Original
|
PDF
|
|
6v step down transformers
Abstract: No abstract text available
Text: FETCO TYPE IPTL ECTRO TUCHNIK ISOLATION POWER TRANSFORMERS / STEP UP or STEP DOWN - - Features: • I Output Voltage: 1 04V, 11 OV, 1 20V, 208V, 220V, 230V, & 240V • Power: 250VA to 10 KVA • • • Dielectric Strength: 2500 VRMS Hipot 0C Insulation: Class “A’ insulation - 105
|
Original
|
PDF
|
250VA
and208/220/240
6v step down transformers
|
K3009U
Abstract: No abstract text available
Text: mm HAMMOND /U4NUE4CTURING,. i l l w Transformers COPPER WOUND — SINGLE PHASE Pri V Sec V 240 x 480 120/240 kVA Mfr No. Wiring Dlag. Mfr. No. Wiring Dlag. Mfr. No. Wiring Diag. 3 5 7.5 10 15t 251 37.5 50 75 100 150 167 250 333 Q003LECF Q005LECF Q007LECF Q010LECF
|
OCR Scan
|
PDF
|
Q003LECF
Q005LECF
Q007LECF
Q010LECF
F015LEC
F025LEC
F037LEC
F050LEC
F075LEC
F100LEC
K3009U
|
1000 kVA transformer
Abstract: No abstract text available
Text: -1*-* f [ *; c;, !l Ians @ - :. ,„2M„ INPUT VOLTAGE 120 X 240: OUTPUT VOLTAGE 12/24 — 60 Hz Catalog Number Insulating Transformer Rating Secondary Maximum Current Output 12V 24 V Approximate Dimensions In Inches Height Width Depth Approximate Net Weight
|
OCR Scan
|
PDF
|
T-1-81047
T-1-81048
T-1-81049
T-1-81050
T-1-81051
f-1-81052
T-1-11683
T-1-11684
T-1-13073
T-1-13074
1000 kVA transformer
|
Untitled
Abstract: No abstract text available
Text: NiiSB • r t n i H H Wh Specifications 120 X 240 PRIMARY VOLTS — 12/24 SECONDARY VOLTS — 60 Hz CATALOG NUMBER INSULATING TRANSFORMER RATING T-1-81047 T-1-81048 T-1-81049 SECONDARY MAXIMUM Current Output APPROX. DIMENSIONS Inches Cm. 12 V 24 V HEIGHT
|
OCR Scan
|
PDF
|
T-1-81047
T-1-81048
T-1-81049
T-1-81050
T-1-81051
T-1-81052
T-1-13077
T-2-13078
T-2-13079
|
Diode LT 404
Abstract: No abstract text available
Text: s e M IK R D n SKiiP 312 GDL 120 - 404 WT E/U Absolute Maximum Ratings Symbol | Conditions Values Units 1200 - 5 5 . . . + 150 V V A A °C 3 0 0 0 5) V 240 A A A kA2s 11 IGBT & Invcsrse Diode Vces Operating DC link voltage Vc c 10) Theatsink — 2 5 °C
|
OCR Scan
|
PDF
|
613bb71
QQ05Q01
ai3bb71
0GQ50G3
00G5D04
Diode LT 404
|
Untitled
Abstract: No abstract text available
Text: ANALOG DEVICES FEATURES Accepts a V ariety of RTD Types 100 i l Platinum , 10 i l Copper, 120 i l Nickel Linearizes RTD Signal 1500 V rms In p u t/O u tp u t and In p u t/P o w er Isolation 250 V rms O u tp u t/P o w e r Isolation 240 V rms Field W iring Protection
|
OCR Scan
|
PDF
|
5B35-01
5B35-02
5B35-03
5B35-04
5B35-05
5B35-C-01
5B35-C-02
5B35-N-01
|
5B35
Abstract: 5B35-01 5B35-02 5B35-03 5B35-04 5B35-05 5B35-C-01 5B35-C-02 5B35-N-01
Text: ANALOG DEVICES FEATURES Accepts a V a rie ty o f RTD Types 100 i l P latin u m , 10 i l C o p per, 120 i l Nickel Lin earizes RTD Sign al 1500 V rm s In p u t/O u tp u t and In p u t/P o w e r Iso latio n 250 V rm s O u tp u t/P o w e r Iso latio n 240 V rm s Field W irin g P ro tectio n
|
OCR Scan
|
PDF
|
5B35-C-CUSTOM.
5B35-N-CUSTOM.
5B35
5B35-01
5B35-02
5B35-03
5B35-04
5B35-05
5B35-C-01
5B35-C-02
5B35-N-01
|
1156D-1256D
Abstract: powerstat 1156D powerstat 1256DU-3Y powerstat 116 T5587 1256D-2P 1256DU powerstat t5587 1156DT-3Y
Text: 1156D-1256D series POWERSTAT Variable Transformers of the 1156D-1256D Series are available in single and three phase, manually operated and motor-driven assemblies. The 1156D Series operates from 120 volt lines and the 1256D Series from 240 volt lines. The rated
|
OCR Scan
|
PDF
|
1156D-1256D
1156D
1256D
allowa837
18-GANG
powerstat
1156D powerstat
1256DU-3Y
powerstat 116
T5587
1256D-2P
1256DU
powerstat t5587
1156DT-3Y
|
Untitled
Abstract: No abstract text available
Text: DRY-TYPE DISTRIBUTION TRANSFORMERS SECTIO N 1 Do You Have a Non-Standard Three Phase Voltage Application?_ M any non-standard v o lta y r c u n v c lii i problem s can lx* solved by u h n y standard off-the-shelf sinyle phase transtnm uT'The follow ing is a list of such volt aye
|
OCR Scan
|
PDF
|
208Y/120
416Y/240
Delta/120
|