Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    26 KW MOTOR Search Results

    26 KW MOTOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TB67H451AFNG Toshiba Electronic Devices & Storage Corporation Brushed Motor Driver/1ch/Vout(V)=50/Iout(A)=3.5 Visit Toshiba Electronic Devices & Storage Corporation
    TB67H450AFNG Toshiba Electronic Devices & Storage Corporation Brushed Motor Driver/1ch/Vout(V)=50/Iout(A)=3.5 Visit Toshiba Electronic Devices & Storage Corporation
    TB67S580FNG Toshiba Electronic Devices & Storage Corporation Stepping Motor Driver/Unipolar Type/Vout(V)=50/Iout(A)=1.6 Visit Toshiba Electronic Devices & Storage Corporation
    TB67S581FNG Toshiba Electronic Devices & Storage Corporation Stepping Motor Driver/Unipolar Type/Vout(V)=50/Iout(A)=2.5 Visit Toshiba Electronic Devices & Storage Corporation
    TB67Z833SFTG Toshiba Electronic Devices & Storage Corporation Brushed Motor Driver / 3-Phase Brushless Motor Gate Driver / VVM(V)=-0.3~80 / P-WQFN40-0606-0.50-003 Visit Toshiba Electronic Devices & Storage Corporation

    26 KW MOTOR Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    3RT10 15-1AP01

    Abstract: 3RH19 21-1HA22 3RT1017 3TF28 3RT10 15-1AB01 3RH19 21 3RT13 16-1BB40 siemens sirius 3r 3rt1025 SIEMENS 3RT1026
    Text: Schaltgeräte für Verbraucherabzweige Schütze, Schützkombinationen SIRIUS 3R Schütze SIRIUS 3R mit Schraubanschluß bis 45 kW Seite Schütze 3RT10 zum Schalten von Motoren, 3polig, S00 bis S3 mit aufsetzbaren Hilfsschalterblöcken Technische Daten Beschreibung


    Original
    3RT10 3RT16, 3RT13 3RT15 NSK-8093 NSK-8094 3RT10 3RA19 NSK-7789 3RT10 15-1AP01 3RH19 21-1HA22 3RT1017 3TF28 3RT10 15-1AB01 3RH19 21 3RT13 16-1BB40 siemens sirius 3r 3rt1025 SIEMENS 3RT1026 PDF

    star delta motor starter with siemens contactor

    Abstract: star delta starter 4.0 kw to 100 kw type 2 coordination table siemens star delta starter siemens contactor 3rt 3RT siemens Siemens 3RT,Contactors siemens 110 kW motors HRC fuse 3NA siemens IEC 60947-4-1
    Text: 3RA13, 3RA14 Contactor Assemblies 3RA14 Contactor Assemblies for Wye-Delta Starting 3RA14 complete units, 3 . 75 kW • Function 3 Wye-delta starting can only be used either if the motor normally operates in a D connection or starts softly or if the load torque


    Original
    3RA13, 3RA14 star delta motor starter with siemens contactor star delta starter 4.0 kw to 100 kw type 2 coordination table siemens star delta starter siemens contactor 3rt 3RT siemens Siemens 3RT,Contactors siemens 110 kW motors HRC fuse 3NA siemens IEC 60947-4-1 PDF

    siemens 3UA59

    Abstract: siemens 3ua59 00 3UA SIEMENS 3UA* siemens siemens sirius 3r 3RB12 3UA59* siemens 3tf2 siemens 3UA7* siemens 3UA59
    Text: Schaltgeräte für Verbraucherabzweige Überlastrelais, Thermistor-Motorschutz, Fehlerstromschutzeinrichtung, Stromrelais Thermisch verzögerte Überlastrelais 3RU11 Seite 3UA Seite SIRIUS 3R für Auslösezeiten bis 10 s mit Schraubanschluß mit Cage-Clamp-Anschluß


    Original
    3RU11 3RB10 3RB12 NSK-7600 NSK-7601 3RU11 NSK-7599 NSK-7515a siemens 3UA59 siemens 3ua59 00 3UA SIEMENS 3UA* siemens siemens sirius 3r 3RB12 3UA59* siemens 3tf2 siemens 3UA7* siemens 3UA59 PDF

    schneider LC1-D38

    Abstract: LC1-D38 LC1-D09 LC1-D123 lc1d128 LC1-D093 LC1D09 schneider LC1-DT25 schneider LC1-D258 schneider LC1-D09
    Text: References TeSys contactors For motor control up to 75 kW at 400 V, in category AC-3 Control circuit: a.c., d.c. or low consumption 810356 3-pole contactors for connection by screw clamp terminals or connectors Standard power ratings of 3-phase motors 50/60 Hz in category AC-3


    Original
    LC1-D09// LC1-D12// LC1-D18// LC1-D25// LC2-DT20. schneider LC1-D38 LC1-D38 LC1-D09 LC1-D123 lc1d128 LC1-D093 LC1D09 schneider LC1-DT25 schneider LC1-D258 schneider LC1-D09 PDF

    wiring diagram dol motor starter

    Abstract: up62 star delta FORWARD REVERSE STARTER hp 15 star delta control 3phase DANFOSS 047B3159 automatic brake failure indicator DANFOSS ci 12 contactor wiring diagram 037N0057 3 phase 5.5 kw soft starter diagram
    Text: Industrial Controls Smoother running Longer lasting Electronic contactors and motor controllers Product overview and selection guide CI-tronic stands for high performance and long life There are many ways to control a heating process or a motor, but you’ll have a hard time finding a better way


    Original
    520B0736/DKACT wiring diagram dol motor starter up62 star delta FORWARD REVERSE STARTER hp 15 star delta control 3phase DANFOSS 047B3159 automatic brake failure indicator DANFOSS ci 12 contactor wiring diagram 037N0057 3 phase 5.5 kw soft starter diagram PDF

    LC1-D09

    Abstract: dimension LC1-D09 LC1-D25 LC1-D09 installation manual LC1-D25 wiring LC1-D2500 LP1-D09 380V 415v motor LC1 D25008 LP1-D25
    Text: Motor Control Device 1-1 Magnetic latching contactors GCR1-F series magnetic latching contactors Magnetic latching contactors of both block and bar mounted types are fitted with a special electromagnet which enables them to remain in the "On" position when the coil is no longer energised.


    Original
    GLE1-D09 GLE1-D018 GLE1-D25 GLE1-D32 GLE1-D40 GLE1-D95 LC1-D09 dimension LC1-D09 LC1-D25 LC1-D09 installation manual LC1-D25 wiring LC1-D2500 LP1-D09 380V 415v motor LC1 D25008 LP1-D25 PDF

    TA84005F

    Abstract: TB6548F 26 KW motor SSOP30-P-375-1 TB6537
    Text: TA84005F TOSHIBA Bipolar Linear IC Silicon Monolithic TA84005F Three-Phase Wave Motor Driver IC The TA84005F is a three-phase wave motor driver IC. Used with a three-phase sensorless controller TB6548F , the TA84005F can provide PWM sensorless drive for three-phase


    Original
    TA84005F TA84005F TB6548F) SSOP30-P-375-1 TB6548F 26 KW motor TB6537 PDF

    yl1 TRANSISTOR

    Abstract: MFC-L2 CFG20 H333 TB6534F TD62M3702F CU126 ym34
    Text: TB6534F TOSHIBA Bi-CMOS Digital Integrated Circuit Silicon Monolithic TB6534F Video Camera Cylinder Motor Controllers and Capstan Motor Controllers The TB6534F is a single-chip IC for video camera cylinder motor controllers and capstan motor controllers. The cylinder section is a soft-switching pre-driver based on a


    Original
    TB6534F TB6534F yl1 TRANSISTOR MFC-L2 CFG20 H333 TD62M3702F CU126 ym34 PDF

    100B330JW

    Abstract: chip resistors 0805 philips MRF9100 esd z10
    Text: MOTOROLA SEMICONDUCTOR TECHNICAL DATA The RF MOSFET Line MRF9100 MRF9100R3 MRF9100SR3 RF Power Field Effect Transistors N–Channel Enhancement–Mode Lateral MOSFETs Designed for GSM and EDGE base station applications with frequencies from 921 to 960 MHz, the high gain and broadband performance of these


    Original
    MRF9100 MRF9100R3 MRF9100SR3 100B330JW chip resistors 0805 philips esd z10 PDF

    3.3KW motor

    Abstract: ricon LAG665F Contek Microelectronics
    Text: LAG665F LINEAR INTEGRATED CIRCUIT RADIO AND CASSETTE RECORDER CIRCUIT DESCRIPTION The ContekLAG665F is a monolithic integrated circuit, designed for portable radio cassette. FEATURES *1-Chip stereo tape recorder with motor speed controller. *Operating supply voltage range: Vcc=2~5V


    Original
    LAG665F ContekLAG665F OP-28 3.3KW motor ricon LAG665F Contek Microelectronics PDF

    3phase winding data 3.7 kw to 110 kw

    Abstract: 1000v contactor J7KN-22-01 j7kn-32 J73KN-b-01 KNC 201 15 yd 803 knc 201 39 wiring diagram to hold contactor with NO, NC controls for 22kw motor
    Text: Motor Contactor Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 45 kW W • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof ( VBG 4) Accessoires • front mounted d single pole additional auxiliary contacts


    Original
    380/415V) Conta7KN-10-01 J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 3phase winding data 3.7 kw to 110 kw 1000v contactor J7KN-22-01 j7kn-32 J73KN-b-01 KNC 201 15 yd 803 knc 201 39 wiring diagram to hold contactor with NO, NC controls for 22kw motor PDF

    encoder line driver

    Abstract: maxon RE 50 maxon RE 50 motor 110514 maxon ec-40 Souriau 8gm.ql2 maxon a-max 26 gp 823 maxon ec motor 25 maxon
    Text: maxon tacho Digital Encoder HEDL 55_ with Line Driver RS 422 Stock program Standard program Special program on request! Order Number 110512 110514 110516 110518 3 4 6 8 Type Shaft diameter overall length mm overall length Combination + Motor RE 25, 10 W


    Original
    PDF

    catalog for 3RT series contactor* siemens

    Abstract: catalog for 3tf series contactor* siemens 3RT siemens siemens contactor 3TF siemens magnetic contactor siemens contactor 3rt 3th42 siemens 3th42 catalog for 3RT Power contactor* siemens 3TB siemens contactor
    Text: Controls – Contactors and Contactor Assemblies 3/2 3/4 3/8 3/30 3/31 3/34 3/35 3/38 3/43 3/46 3/53 3/54 3/55 3/56 3/58 3/61 3/62 3/64 3/66 3/67 3/68 3/69 3/73 3/74 3/75 Introduction 3RT, 3TB, 3TF Contactors for Switching Motors General data 3RT10 contactors, 3-pole, 3 . 250 kW


    Original
    3RT10 3RT12 3RA13, 3RA14 3RA13 46-3KF44-0LA0 catalog for 3RT series contactor* siemens catalog for 3tf series contactor* siemens 3RT siemens siemens contactor 3TF siemens magnetic contactor siemens contactor 3rt 3th42 siemens 3th42 catalog for 3RT Power contactor* siemens 3TB siemens contactor PDF

    siemens soft starter 3rw44

    Abstract: Sirius 3Rv siemens star delta starter 3RW44 siemens soft starter Sirius 3RW40 3RW4900-0KC00 star delta motor starter with siemens contactor 3RW444 3UF7940-0AA00-0
    Text: Siemens AG 2008 Dynamics Reinterpreted The Comprehensive Range of SIRIUS Soft Starters www.siemens.com/softstarter © Siemens AG 2008 The Ideal SIRIUS Soft Starter for All Applications Today, three-phase motors serve as the ultimate drive concept. Yet, for many


    Original
    E20001-A1040-P302-X-7600 21C/9315 siemens soft starter 3rw44 Sirius 3Rv siemens star delta starter 3RW44 siemens soft starter Sirius 3RW40 3RW4900-0KC00 star delta motor starter with siemens contactor 3RW444 3UF7940-0AA00-0 PDF

    ABB A26-30-10

    Abstract: star delta timer starter diagram magnetic Contactor abb a9-30-10 star delta starter diagram star delta wiring diagram with magnetic and timer wiring diagram star delta starter wiring diagram ABB motor starter VE 5-2 ABB 3 phase 380v motor starter overload relay chart A9-30-10
    Text: Application Guide Motor Starting Solutions Open Type Version In Kit Form Complete Range of Products and Accessories to Create all Motor Starter Types Manual motor starter Short-Circuit Protection. Type 1 or 2 coordination guaranteed between contactors and short-circuit


    Original
    R2000 1SBC101001C0201 F-69685 C0201 ABB A26-30-10 star delta timer starter diagram magnetic Contactor abb a9-30-10 star delta starter diagram star delta wiring diagram with magnetic and timer wiring diagram star delta starter wiring diagram ABB motor starter VE 5-2 ABB 3 phase 380v motor starter overload relay chart A9-30-10 PDF

    siemens sirius 3r

    Abstract: a/3RV10
    Text: 3RT10 Contactors for Switching Motors SIRIUS 3R Technical data s and u ratings of the contactors Contactor Size Type AC V Rated insulation voltage Conventional thermal current Free air and enclosed Maximum horsepower ratings s and u-approved values Ratings


    Original
    3RT10 siemens sirius 3r a/3RV10 PDF

    fan motor winding formula

    Abstract: Brown Boveri induction Motor frame IEC-34-1 IEC 34-1 IM3011 m2va IM3001 asea EH 9-10 IM3601 IM1001
    Text: M2000 Aluminium Motors ABB LV Motors M2000 Range ABB Automation Making you more competitive ABB LV Motors knows about customer needs. For over 100 years we have been designing motors for every need and application. With a reputation for quality that is second to none,


    Original
    M2000 24-hour M2000 fan motor winding formula Brown Boveri induction Motor frame IEC-34-1 IEC 34-1 IM3011 m2va IM3001 asea EH 9-10 IM3601 IM1001 PDF

    3phase winding data 3.7 kw to 110 kw

    Abstract: feeder J74-WKR-B J7KN24 DOL reversing wiring diagram motor J7KNG-22-4 wiring diagram 3 phase dol compressor magnetic Contactor wiring diagrams J7KN14-01 J74KN-C-RC24
    Text: Motor Contactor J7KN • Range from 4 to 500 kW AC 3, 380/415 V • AC and DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting (35 mm DIN rail) upto 37 kW • Compliant to the global standards • Finger proof (BGV A2) • System contactors for Fuseless Load Feeders with integrated


    Original
    J74KN-C-RC J74KN-B-RC J74KN-LG-9030 J74KN-LG-11224 J74KN-LG-10404 J74KN-LG-11457 J74KN-P J74-WKR-B J74-WKR-C J74-WKSD-B 3phase winding data 3.7 kw to 110 kw feeder J7KN24 DOL reversing wiring diagram motor J7KNG-22-4 wiring diagram 3 phase dol compressor magnetic Contactor wiring diagrams J7KN14-01 J74KN-C-RC24 PDF

    transistor motorola 114-8

    Abstract: motorola s 114-8 Z9 TRANSISTOR SMD transistor J585 smd wb1 transistor smd wb1 motorola 114-8
    Text: MOTOROLA SEMICONDUCTOR TECHNICAL DATA The RF MOSFET Line MRF18090A MRF18090AS RF Power Field Effect Transistors N–Channel Enhancement–Mode Lateral MOSFETs Designed for GSM and EDGE base station applications with frequencies from 1.8 to 2.0 GHz. Suitable for FM, TDMA, CDMA and multicarrier amplifier


    Original
    MRF18090A MRF18090AS transistor motorola 114-8 motorola s 114-8 Z9 TRANSISTOR SMD transistor J585 smd wb1 transistor smd wb1 motorola 114-8 PDF

    ESSEX Contactor

    Abstract: LS 32 CONTACTOR LS Contactor ROTOR STAR 415 AC, 3 phase to 600V dc transformer CETA CETA25-32 120v AC to 12V dc transformer CETA12
    Text: In stallatio n - C E T A C o n tacto r General Data Contactor ratings 3-phase motor switching Contactor types CETA09-16 Max. ops/h 1200 75 a.c. 9 a.c. 100 a.c. 10 a.c. Operating times ms Closing Opening 11 - 22 a.c. 5 - 1 9 a.c. 22 - 29 a.c. 1 0- 15 a.c.


    OCR Scan
    CETA09-16 CETA25-32 CETA09 CETA12 CETA16 CETA25 CETA32 ESSEX Contactor LS 32 CONTACTOR LS Contactor ROTOR STAR 415 AC, 3 phase to 600V dc transformer CETA 120v AC to 12V dc transformer PDF

    Untitled

    Abstract: No abstract text available
    Text: MOTOROLA Order this document by MRF9100/D SEMICONDUCTOR TECHNICAL DATA The RF MOSFET Line RF Power Field Effect Transistors MRF9100R3 MRF9100SR3 N - Channel Enhancement - Mode Lateral MOSFETs Designed for GSM and EDGE base station applications with frequencies


    Original
    MRF9100/D MRF9100R3 MRF9100SR3 MRF9100/D PDF

    Transistor J182

    Abstract: MRF9100 MRF9100R3 MRF9100SR3 08053G105ZATEA
    Text: MOTOROLA Order this document by MRF9100/D SEMICONDUCTOR TECHNICAL DATA The RF MOSFET Line MRF9100 MRF9100R3 MRF9100SR3 RF Power Field Effect Transistors N–Channel Enhancement–Mode Lateral MOSFETs Designed for GSM and EDGE base station applications with frequencies


    Original
    MRF9100/D MRF9100 MRF9100R3 MRF9100SR3 MRF9100 MRF9100R3 Transistor J182 MRF9100SR3 08053G105ZATEA PDF

    3phase winding data 3.7 kw to 110 kw

    Abstract: J73KN-b-01 ICE 947 EN 60947 3 phase, 415v and 37 kw motor yd 803 J7KN110 3 phase, 415v and 270 kw motor EM- 546 motor wiring diagram 3 phase dol compressor Starting Current 7.5KW Motor 440v
    Text: Motor Contactor J7KN Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 45 kW • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof ( VBG 4) Accessories • front mounted single pole additional auxiliary contacts


    Original
    380/415V) J7KN-10-01 J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 3phase winding data 3.7 kw to 110 kw J73KN-b-01 ICE 947 EN 60947 3 phase, 415v and 37 kw motor yd 803 J7KN110 3 phase, 415v and 270 kw motor EM- 546 motor wiring diagram 3 phase dol compressor Starting Current 7.5KW Motor 440v PDF

    gv3-me80

    Abstract: GV3ME80 220v motor overload protection 690V electric motor 380V 415v motor EGV2-RS16 11-1JA1 egv3 21-1EA1 11-1DA1
    Text: Motor Control Device 5-1 Motor protection circuit breaker E3VU series circuit breakers Application E3VU series circuit breakers are applicable for the circuit of AC 50/60Hz, rated insulation voltage 750V, rated operating voltage up to 660V, rated operation current from 0.1A to 63A. They are used for protecting motors against overload, short-circuit and phase-failure. They


    Original
    50/60Hz, A-63A. 50/60Hz E3VU13-XB00 E3RV10 21-4CA1 21-4DA1 AC50Hz, E3RV10-11 gv3-me80 GV3ME80 220v motor overload protection 690V electric motor 380V 415v motor EGV2-RS16 11-1JA1 egv3 21-1EA1 11-1DA1 PDF