    Abstract: 30076 HUB1000-P mov 30076 26108 schottky diode half bridge schematic zcs amps circuit diagram of 12 to 300 vdc boost converter 26108 1.5KE-150CA 1N4691
    Text: 10. High Boost HAM Design Guide & Applications Manual For Maxi, Mini, Micro Family DC-DC Converters and Configurable Power Supplies THE HIGH-BOOST HARMONIC ATTENUATOR MODULE COMPATIBLE WITH V375, VI-26x AND VI-J6x FAMILIES The HAMD version does not contain an internal bridge


    Original
    PDF VI-26x transorb diode equivalent 30076 HUB1000-P mov 30076 26108 schottky diode half bridge schematic zcs amps circuit diagram of 12 to 300 vdc boost converter 26108 1.5KE-150CA 1N4691

    schematic diagram 240 AC to 110 DC converter

    Abstract: transorb diode equivalent 26108 diode transorb failure Variable AC voltage AutoTransformer 440 vac to 190 vdc bridge rectifier circuit dc-dc driver schematic transorb diode 30076 230 vac to 190 vdc bridge rectifier
    Text: 13. AC Input Harmonic Attenuator Module HAM Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies THE HARMONIC ATTENUATOR MODULE COMPATIBLE WITH VI-26x AND VI-J6x FAMILIES The HAMD version does not contain an internal bridge


    Original
    PDF VI-200 VI-J00 VI-26x 435than schematic diagram 240 AC to 110 DC converter transorb diode equivalent 26108 diode transorb failure Variable AC voltage AutoTransformer 440 vac to 190 vdc bridge rectifier circuit dc-dc driver schematic transorb diode 30076 230 vac to 190 vdc bridge rectifier

    transorb diode equivalent

    Abstract: 01000 ycap* vicor 115 vac SINGLE phase bridge rectifier 3AR3
    Text: PRELIMINARY 45 VI-HAM TM High-Boost Harmonic Attenuation Module Features • • • • • • • 675 Watts output power Unity power factor 85-264 Vac universal input Meets EN 61000-3-2 Short circuit protection Input surge limiting High efficiency Actual size:


    Original
    PDF

    07818 filter

    Abstract: 115 vac 3 phase bridge rectifier HUB1000-P 115 vac SINGLE phase bridge rectifier HUB820-P 26108 1N4006 1N4691 1N5817 HUB270-P
    Text: 45 VI-HAM TM High-Boost Harmonic Attenuation Module Features • • • • • • • 675 Watts output power Unity power factor 85-264 Vac universal input Meets EN 61000-3-2 Short circuit protection Input surge limiting High efficiency Actual size: 4.6 x 2.4 x 0.5 in


    Original
    PDF

    07818 filter

    Abstract: HUB1000-P 26108 26108 VICOR
    Text: 45 VI-HAM TM High-Boost Harmonic Attenuation Module Features • • • • • • • 675 Watts output power Unity power factor 85-264 Vac universal input Meets EN 61000-3-2 Short circuit protection Input surge limiting High efficiency Actual size: 4.6 x 2.4 x 0.5 in


    Original
    PDF

    VICOR 26108

    Abstract: No abstract text available
    Text: 45 VI-HAM TM High-Boost Harmonic Attenuation Module Features • • • • • • • 675 Watts output power Unity power factor 85-264 Vac universal input Meets EN 61000-3-2 Short circuit protection Input surge limiting High efficiency Actual size: 4.6 x 2.4 x 0.5 in


    Original
    PDF

    HUB470-P

    Abstract: HUB820-P Vicor V375
    Text: Data Sheet VI-HAM High-Boost Harmonic Attenuation Module Features • • • • • • • TM 675 Watts output power Unity power factor 85 – 264 Vac universal input Meets EN61000-3-2 Short circuit protection Input surge limiting High efficiency Product Overview


    Original
    PDF EN61000-3-2 HUB470-P HUB820-P Vicor V375

    MOV 270

    Abstract: 30234-220 HUB1200-S HUB820-S 26108 HUB2200-S HUB3300-S HUB1800-S converter module 200 density converter V300A15C500BL
    Text: OffLine Power Supply Using the FARM AC Front-End Module By John Harding Senior Applications Engineer Vicor TPB 107 FARM2xxx is rated for 750 W and 1000 W for the low and high input ranges respectively. Either of these modules can serve as the AC front-end for any number and combination of


    Original
    PDF 2200F 11--Ripple 12--Converter MOV 270 30234-220 HUB1200-S HUB820-S 26108 HUB2200-S HUB3300-S HUB1800-S converter module 200 density converter V300A15C500BL

    30205

    Abstract: 30076 1N4006 1N4691 1N5817 EN61000-3-3 EN61000-4-11 EN61000-4-5 ce jmk
    Text: Data Sheet VI-HAM , VE-HAM TM TM Harmonic Attenuation Module Compatible with VI-26x and VI-J6x modules Features • Unity power factor • Safety agency approvals: CE marked, cTÜVus, cURus • Meets IEC 6100-3-2 for line Current harmonic content • Reduces peak and RMS line currents


    Original
    PDF VI-26x 30205 30076 1N4006 1N4691 1N5817 EN61000-3-3 EN61000-4-11 EN61000-4-5 ce jmk

    30205

    Abstract: 1.5KE*CA amps circuit diagram of 12 to 300 vdc boost converter 30076 mov 30076 1N4006 1N4691 Vicor 30076 EN61000-3-3 EN61000-4-11
    Text: Data Sheet VI-HAM , VE-HAM TM TM Harmonic Attenuation Module Compatible with VI-26x and VI-J6x modules Features • Unity power factor • Safety agency approvals: CE marked, cTÜVus, cURus • Meets IEC 6100-3-2 for line Current harmonic content • Reduces peak and RMS line currents


    Original
    PDF VI-26x 30205 1.5KE*CA amps circuit diagram of 12 to 300 vdc boost converter 30076 mov 30076 1N4006 1N4691 Vicor 30076 EN61000-3-3 EN61000-4-11

    30076

    Abstract: VI-HAMD 1N4006 1N4691 EN61000-3-3 EN61000-4-11 EN61000-4-5 transorb diode equivalent
    Text: Data Sheet VI-HAM , VE-HAM TM TM High-Boost Harmonic Attenuation Module Features • 675 Watts output power • Unity power factor • 85 – 264 Vac universal input • Meets EN61000-3-2 • Short circuit protection • Input surge limiting • High efficiency


    Original
    PDF EN61000-3-2 VI-26x 30076 VI-HAMD 1N4006 1N4691 EN61000-3-3 EN61000-4-11 EN61000-4-5 transorb diode equivalent

    Vicor V375

    Abstract: 30205 VICOR 26108 Vicor 30076
    Text: VI-HAM , VE-HAM™ VxHAMxL Actual Size: 4.6 x 2.4 x 0.5 in 116,8 x 61,0 x 12,7 mm S C US C NRTL US High-Boost Harmonic Attenuation Module Absolute Maximum Ratings Features • 675 Watts output power • Unity power factor • 85 – 264 Vac universal input


    Original
    PDF EN61000-3-2 VI-26x Vicor V375 30205 VICOR 26108 Vicor 30076

    26108

    Abstract: 26108 diode vicor
    Text: VI-HAM , VE-HAM™ VxHAMxM Compatible with VI-26x and VI-J6x modules Actual Size: 4.6 x 2.4 x 0.5 in (116,8 x 61,0 x 12,7 mm) S C US C NRTL US Harmonic Attenuation Module Features • Unity power factor • Safety agency approvals: CE marked, cTÜVus, cURus


    Original
    PDF VI-26x 26108 26108 diode vicor

    30234-220

    Abstract: HUB1800-S diode 1n4006 HUB1200-S HUB2200-S 26108 30076 1N4006 1N5817 1.5KE*CA
    Text: 9. Modular AC Front-end System ENMod Design Guide & Applications Manual For Maxi, Mini, Micro Family DC-DC Converters and Configurable Power Supplies The ENMod component power front-end system for EN compliance provides an effective solution for an AC front end of a power supply enabled with Vicor DC-DC


    Original
    PDF

    VI-ARMB-C22

    Abstract: 30076 1N5817 ABC-10 V300A48C500BL full bridge schematic zcs 06852 Basic Bridge rectifier
    Text: Power components simplify 1 kw power design By Jeff Ham Sr. Application Engineer, Vicor TPB 102 INTRODUCTION PART 1: STEP-BY-STEP DESIGN EXAMPLE Not long ago, designing a 1,000 W power supply for operation on worldwide AC lines was a task for the most experienced power design engineers. Besides dealing


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: PRELIMINARY 45 Data Sheet FARM TM Filter/ Autoranging Rectifier Module Up to 1000 Watts Features • • • • • • • • • EMI filtering Choice of 500W or 750W modules 96% Efficiency Autoranging 115/230Vac input Microprocessor controlled Inrush current limiting


    Original
    PDF 115/230Vac 500/750W 750/1000W 04/03/10M

    1000w dc rectifier

    Abstract: No abstract text available
    Text: PRELIMINARY 45 Data Sheet FARM TM Filter/ Autoranging Rectifier Module Up to 1000 Watts Features • • • • • • • • • EMI filtering Choice of 500W or 750W modules 96% Efficiency Autoranging 115/230Vac input Microprocessor controlled Inrush current limiting


    Original
    PDF 115/230Vac 500/750W 750/1000W 05/03/10M 1000w dc rectifier

    HUB820-S

    Abstract: HUB2200-S HUB820 EN61000-4-5 HUB1200-S 3A 300V 500W DIODE HUB3300-S
    Text: PRELIMINARY 45 Data Sheet FARM TM Filter/ Autoranging Rectifier Module Up to 1000 Watts Features • • • • • • • • • EMI filtering Choice of 500W or 750W modules 96% Efficiency Autoranging 115/230Vac input Microprocessor controlled Inrush current limiting


    Original
    PDF 115/230Vac 500/750W 750/1000W 05/03/10M HUB820-S HUB2200-S HUB820 EN61000-4-5 HUB1200-S 3A 300V 500W DIODE HUB3300-S

    thermistor 1kv

    Abstract: EN61000-4-5 HUB2200-S HUB820-S
    Text: PRELIMINARY 45 Data Sheet FARM TM Filter/ Autoranging Rectifier Module Up to 1000 Watts Features • • • • • • • • • EMI filtering Choice of 500W or 750W modules 96% Efficiency Autoranging 115/230Vac input Microprocessor controlled Inrush current limiting


    Original
    PDF 115/230Vac 500/750W 750/1000W 4/03/10M thermistor 1kv EN61000-4-5 HUB2200-S HUB820-S

    HUB1000-P

    Abstract: MOV surge protection circuit diagram schematic diagram induction heating transorb 30076 1N4006 1N4691 1N5817 EN61000-3-3 EN61000-4-11
    Text: Data Sheet VI-HAM , VE-HAM TM TM Harmonic Attenuation Module Compatible with VI-26x and VI-J6x modules Features • Unity power factor • Safety agency approvals: CE marked, cTÜVus, cURus • Meets IEC 6100-3-2 for line Current harmonic content • Reduces peak and RMS line currents


    Original
    PDF VI-26x HUB1000-P MOV surge protection circuit diagram schematic diagram induction heating transorb 30076 1N4006 1N4691 1N5817 EN61000-3-3 EN61000-4-11

    Untitled

    Abstract: No abstract text available
    Text: Data Sheet Factorized Power FARM TM Filter/ Autoranging Rectifier Module Up to 1000 Watts Features • • • • • • • • • EMI filtering Choice of 500 W or 750 W modules 96% Efficiency Autoranging 115/230 Vac input Microprocessor controlled Inrush current limiting


    Original
    PDF 08/04/10M

    Untitled

    Abstract: No abstract text available
    Text: PRELIMINARY 45 Features • Harmonic Current Attenuation to EN61000-3-2 • EMI Filtering to EN55022, Level B • Transient Immunity to EN61000-4-5 • 575W Rated Power Output • Autoranging 115/230Vac Input • Microprocessor Control • Inrush Current Limiting


    Original
    PDF EN61000-3-2 EN55022, EN61000-4-5 115/230Vac 05/03/10M

    Untitled

    Abstract: No abstract text available
    Text: 45 Features • Autoranging input • Microprocessor controlled • VI-ARM-C1 500 Watts @ 90-132Vac 750 Watts @ 180-264Vac • VI-ARM-C2 1000 Watts @ 90-132Vac 1500 Watts @ 180-264Vac • 96-98% Efficiency • 100˚C baseplate no derating • UL, CSA, TÜV, VDE, BABT


    Original
    PDF 90-132Vac 180-264Vac 500nt 10/03/10M

    Untitled

    Abstract: No abstract text available
    Text: Data Sheet FARM Features • • • • • • • • • • RoHS compliant with F or G pin style EMI filtering Choice of 500 W or 750 W modules 96% efficiency Autoranging 115/230 Vac input Microprocessor controlled Inrush current limiting Mini sized package