Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    3 PHASE, 415V AND 22 KW MOTOR Search Results

    3 PHASE, 415V AND 22 KW MOTOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TB67B001BFTG Toshiba Electronic Devices & Storage Corporation Brushless Motor Driver/3 Phases Driver/Vout(V)=25/Iout(A)=3/Square Wave Visit Toshiba Electronic Devices & Storage Corporation
    TC78B011FTG Toshiba Electronic Devices & Storage Corporation Brushless Motor Driver/3 Phases Driver/Vout(V)=30/Square, Sine Wave Visit Toshiba Electronic Devices & Storage Corporation
    TB67S141AFTG Toshiba Electronic Devices & Storage Corporation Stepping Motor Driver/Unipolar Type/Vout(V)=84/Iout(A)=3/Phase Interface Visit Toshiba Electronic Devices & Storage Corporation
    TB67B001AFTG Toshiba Electronic Devices & Storage Corporation Brushless Motor Driver/3 Phases Driver/Vout(V)=25/Iout(A)=3/Square Wave Visit Toshiba Electronic Devices & Storage Corporation
    TB67H480FNG Toshiba Electronic Devices & Storage Corporation Stepping Motor Driver/Unipolar Type/Vout(V)=50/Iout(A)=2.5/ PHASE input type Visit Toshiba Electronic Devices & Storage Corporation

    3 PHASE, 415V AND 22 KW MOTOR Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    LC1-D09

    Abstract: Schneider contactor catalogue 3 phase, 415v and 37 kw motor LC1D09 schneider LC1-D18 LC1-D32 schneider LC1-D09 schneider LC1-D80 LC1-D12 schneider LC1-D25
    Text: Star / Delta selections for 415v 3 phase motors Motor F.L.C. against power at 415v based on average typical motors Star / delta components for customer assembly Note: Star / delta kit includes timer, power connections and mechanical interlock Complete starters


    Original
    PDF LC3D09A LC1D09 LAD91217 LRD14 LC3D12A LC1D18 LC1D12 LC1-D09 Schneider contactor catalogue 3 phase, 415v and 37 kw motor LC1D09 schneider LC1-D18 LC1-D32 schneider LC1-D09 schneider LC1-D80 LC1-D12 schneider LC1-D25

    rf9.2v3

    Abstract: BF50-BF110 G361 RF95 RFN420 BG12 RFA95 RF38 0160 RF200 1000v contactor
    Text: 04_Capitolo_04_GB.qxd 3-03-2009 10:59 Pagina 1 4 MOTOR PAGE 4-4 PAGE 4-6 FOR BG SERIES MINI-CONTACTORS FOR BF SERIES CONTACTORS FOR B SERIES CONTACTORS • Type RF9, phase failure sensitive, manual resetting • Type RFA9, phase failure sensitive, automatic resetting


    Original
    PDF RFN38, RFA95, RFN95, 250VAC 50x106 2x105 CE106 rf9.2v3 BF50-BF110 G361 RF95 RFN420 BG12 RFA95 RF38 0160 RF200 1000v contactor

    star delta FORWARD REVERSE STARTER

    Abstract: BS88-6 gec switchgear 100AXTN2 automatic star delta starter using timer BS5419 100KXTNC2F IEC 60269 SIBA wiring diagram for single phase dol motor starter HRC fuse gg GEC
    Text: MEMா Enclosed Switchgear and Motor Control • Fuse-switch-disconnectors & switch disconnectors • Enclosed busbar chambers • HRC distribution fuseboards & fuses Designed with the needs of the installer and building owner in mind • Load break switches


    Original
    PDF PG01900001U star delta FORWARD REVERSE STARTER BS88-6 gec switchgear 100AXTN2 automatic star delta starter using timer BS5419 100KXTNC2F IEC 60269 SIBA wiring diagram for single phase dol motor starter HRC fuse gg GEC

    EATON

    Abstract: 21MSULK star delta motor starter 404RDMP 22MSUL 21MSU2SK 28ARD1X 428ALCFP 22MSU 21MSUL
    Text: ADS8 Wall Chart 22/11/06 5:54 pm Page 1 ADS8 Motor starters and overload relays 9kW DOL starter without switch disconnect 25kW Star Delta starter without switch disconnect • IP 54 metalclad surface mounting enclosure, less overload relay • IP 65 moulded surface mounting enclosure, less overload relay


    Original
    PDF 28ADSM1X 50Hz1 48ADSM1X 28SDA2X18 2812004VCOA 4812004VCOA 2825004VCOA 4825004VCOA EATON 21MSULK star delta motor starter 404RDMP 22MSUL 21MSU2SK 28ARD1X 428ALCFP 22MSU 21MSUL

    3phase winding data 3.7 kw to 110 kw

    Abstract: J73KN-b-01 ICE 947 EN 60947 3 phase, 415v and 37 kw motor yd 803 J7KN110 3 phase, 415v and 270 kw motor EM- 546 motor wiring diagram 3 phase dol compressor Starting Current 7.5KW Motor 440v
    Text: Motor Contactor J7KN Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 45 kW • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof ( VBG 4) Accessories • front mounted single pole additional auxiliary contacts


    Original
    PDF 380/415V) J7KN-10-01 J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 3phase winding data 3.7 kw to 110 kw J73KN-b-01 ICE 947 EN 60947 3 phase, 415v and 37 kw motor yd 803 J7KN110 3 phase, 415v and 270 kw motor EM- 546 motor wiring diagram 3 phase dol compressor Starting Current 7.5KW Motor 440v

    140M-C-AFA11

    Abstract: 100-K05ZJ10 140M-C-PEK12 140M-C2E-C10 140M-C2E-B10 140M-C2E-C25 Allen-Bradley 100-k12 100-k05 140M-C-W454 140M-C2E-B16
    Text: MCS MINIATURE CONTACTORS SELECTION GUIDE THE MINIATURE MODULAR CONTROL SYSTEM SMALL IN DIMENSIONS - BIG IN PERFORMANCE DOL-Starter Overload Protection Short Circuit Protection DOL-Starter Overload Protection PROTECTION FOR AC AND DC MOTORS • The Bulletin 193-K thermal


    Original
    PDF 193-K 100-K 140-M MCS-SG001A-EN-P 140M-C-AFA11 100-K05ZJ10 140M-C-PEK12 140M-C2E-C10 140M-C2E-B10 140M-C2E-C25 Allen-Bradley 100-k12 100-k05 140M-C-W454 140M-C2E-B16

    3phase winding data 3.7 kw to 110 kw

    Abstract: 1000v contactor J7KN-22-01 j7kn-32 J73KN-b-01 KNC 201 15 yd 803 knc 201 39 wiring diagram to hold contactor with NO, NC controls for 22kw motor
    Text: Motor Contactor Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 45 kW W • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof ( VBG 4) Accessoires • front mounted d single pole additional auxiliary contacts


    Original
    PDF 380/415V) Conta7KN-10-01 J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 3phase winding data 3.7 kw to 110 kw 1000v contactor J7KN-22-01 j7kn-32 J73KN-b-01 KNC 201 15 yd 803 knc 201 39 wiring diagram to hold contactor with NO, NC controls for 22kw motor

    telemecanique LR2-D13

    Abstract: LR2-D13 LR2-D13 Telemecanique VDE 0660 - 107 telemecanique lr2d13 overload contactor LR2-D13 IEC 158-1 VDE 0660 LR2D13 telemecanique thermal overload relay trip test solid state timer relays telemecanique
    Text: Issued March 1999 291-9855 Data Pack B Data Sheet The Telemecanique ‘d2’ range of motor control gear The RS ‘d2’ range is a broad and versatile range of motor control gear for the many and varied control applications demanded in a world of increasing


    Original
    PDF 1970s. co237 telemecanique LR2-D13 LR2-D13 LR2-D13 Telemecanique VDE 0660 - 107 telemecanique lr2d13 overload contactor LR2-D13 IEC 158-1 VDE 0660 LR2D13 telemecanique thermal overload relay trip test solid state timer relays telemecanique

    813S

    Abstract: 813S-V3-480V 817S-PTC-48 813S-V3-400V 813S-V3-690V 809S-C1-10A-230 817S-PTC-230 809S-C1-10A-48 813S-V1-500V-48 817S-PTC-115
    Text: SELECTION GUIDE BULLETINS 809S, 813S, 814S, 817S MachineAlert Dedicated Function Motor Protection Relays Bulletin 809S, 813S, 814S, 817S MachineAlert™ Dedicated Function Motor Protection Relays Overview/Catalog Number Explanation The MachineAlert family of dedicated function motor protection relays


    Original
    PDF 809S-SG002A-EN-P 809S-SG002A-EN-P 813S 813S-V3-480V 817S-PTC-48 813S-V3-400V 813S-V3-690V 809S-C1-10A-230 817S-PTC-230 809S-C1-10A-48 813S-V1-500V-48 817S-PTC-115

    Allen-Bradley 100-M09

    Abstract: 100-C09D10 KRY 112 71/2 193-EF1A Allen-Bradley 100-c09*10 193-EF2A 193-EF 140M-C2E-C10 Allen-Bradley 100-c09D10 140M-C-AFA11
    Text: Bulletin 100 Line IEC Contactors, Starters, and Overload Relays Section Overview Motor Protection Circuit Breakers • Bulletin 140M Motor Protection Circuit Breakers Page 5 • Bulletin 140M Motor Circuit Protectors Page 7 • Bulletin 140M Accessories


    Original
    PDF 100/104-M 100/104-C 100/104-D 100-G 100S/104S TZ734 TZ747 TZ779 TZ780 TZS734 Allen-Bradley 100-M09 100-C09D10 KRY 112 71/2 193-EF1A Allen-Bradley 100-c09*10 193-EF2A 193-EF 140M-C2E-C10 Allen-Bradley 100-c09D10 140M-C-AFA11

    FDN36MC100GD

    Abstract: magnetic Contactor wiring diagrams and float switch CL03A FDN36MC080GD star delta FORWARD REVERSE STARTER GPF10C02 GPS1bsah LG0006P1B0 CL07A CL03A-CL04A
    Text: 39584 GE Consumer & Industrial Power Protection GE Consumer & Industrial Power Protection formerly GE Power Controls , a division of GE Consumer & Industrial, is a first class European supplier of low-voltage products including wiring devices, residential and industrial electrical


    Original
    PDF H-1340 B-9000 C/4601/E/EX FDN36MC100GD magnetic Contactor wiring diagrams and float switch CL03A FDN36MC080GD star delta FORWARD REVERSE STARTER GPF10C02 GPS1bsah LG0006P1B0 CL07A CL03A-CL04A

    LC1-D09

    Abstract: dimension LC1-D09 LC1-D25 LC1-D09 installation manual LC1-D25 wiring LC1-D2500 LP1-D09 380V 415v motor LC1 D25008 LP1-D25
    Text: Motor Control Device 1-1 Magnetic latching contactors GCR1-F series magnetic latching contactors Magnetic latching contactors of both block and bar mounted types are fitted with a special electromagnet which enables them to remain in the "On" position when the coil is no longer energised.


    Original
    PDF GLE1-D09 GLE1-D018 GLE1-D25 GLE1-D32 GLE1-D40 GLE1-D95 LC1-D09 dimension LC1-D09 LC1-D25 LC1-D09 installation manual LC1-D25 wiring LC1-D2500 LP1-D09 380V 415v motor LC1 D25008 LP1-D25

    230V 5A OMRON Auxiliary RELAY

    Abstract: star delta wiring diagram with pneumatic timer 220-240v varistor 230V 5A OMRON RELAY NC Contacts J73KN-b-01 transformer winding formula 220v Ac to 110v Ac 3phase winding data 3.7 kw to 110 kw J7KN-14-10 AC415-440V timer omron J74KN-LG-9030
    Text: Motor Contactor J7KN Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 37 kW • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof (BGV A2) • System contactors for Fuseless Load Feeders with integrated


    Original
    PDF 380/415V) omron247 J06E-EN-01A 230V 5A OMRON Auxiliary RELAY star delta wiring diagram with pneumatic timer 220-240v varistor 230V 5A OMRON RELAY NC Contacts J73KN-b-01 transformer winding formula 220v Ac to 110v Ac 3phase winding data 3.7 kw to 110 kw J7KN-14-10 AC415-440V timer omron J74KN-LG-9030

    telemecanique LR2-D13

    Abstract: VDE 0660 iec 158-1 LR2-D13 Telemecanique Contactor JEM AC3 telemecanique IEC 158-1 IEC 158-1 VDE 0660 overload contactor LR2-D13 lr2d13 OVERLOAD lr2-d13 VDE 0660 BS 5424
    Text: Issued November 1991 B12564 The Telemecanique Ôd2Õ range of motor control gear The RS Ôd2Õ range is a broad and versatile range of motor control gear for the many and varied control applications demanded in a world of increasing automation complexity and improvements in reliability. Ôd2Õ is the first complete range to have been


    Original
    PDF B12564 24Vdc 400Hz 50/60Hz A-32A 4-48V 0-127V 10-240V 0A-80A telemecanique LR2-D13 VDE 0660 iec 158-1 LR2-D13 Telemecanique Contactor JEM AC3 telemecanique IEC 158-1 IEC 158-1 VDE 0660 overload contactor LR2-D13 lr2d13 OVERLOAD lr2-d13 VDE 0660 BS 5424

    SIEMENS 3TF47 contactor

    Abstract: 3UA50 siemens modules GR 60 48 V 120 A 3TF52 3UA62 SIEMENS 3TF46 contactor siemens mpcb 3TK2827 3tf54 3tf35
    Text: Unmatched safety that meets all your needs LV Switchgear Price List Maximum Retail Price w.e.f. 1st November, 2010 Answers for industry. s Everything Easy SIRIUS SIEMENS – INDUSTRY SECTOR TRAINING CENTER SITRAIN INDIA, KALWA. List of courses at SITRAIN-Kalwa & Authorized Training Centers ATC


    Original
    PDF S7-200 S7-300 S7-400 SGR-01-114-069 SGR-01-114-054 SGR-01-103-051) SIEMENS 3TF47 contactor 3UA50 siemens modules GR 60 48 V 120 A 3TF52 3UA62 SIEMENS 3TF46 contactor siemens mpcb 3TK2827 3tf54 3tf35

    INVERTER invertron GMI

    Abstract: reliance electric invertron INVERTRON GMI Invertron Vti DBU-400 DBU-200 DBU-50 837.02.01 reliance inverter gp2000 dbu-100
    Text: INVERTRON DBU Dynamic Braking Unit Instruction Manual C Manual P/N. UL R 899.05.26 User Manual: 49‘1328e 06 Publication INVDBU-UM006F-EN-P . TABLE OF CONTENTS 1. DESCRIPTION 1-1.1-2 Operation . 1-1


    Original
    PDF 1328e INVDBU-UM006F-EN-P INVERTER invertron GMI reliance electric invertron INVERTRON GMI Invertron Vti DBU-400 DBU-200 DBU-50 837.02.01 reliance inverter gp2000 dbu-100

    700-HT22AU120

    Abstract: 800T-N1 700-HA32A1 800T-N320G 800T-N169 700-HT12AU120 800T-N320R 700-HT12BU120 1494F-P1 800T-N65
    Text: APPLICATIONS APPLICATIONS APPLICATIONS APPLICATIONS APPLICATIONS APPLICATIONS APPLICATIONS CONTINUOUS HEAVY DUTY CYCLING OF MOTORS | MINING | PETROCHEMICAL PULP & PAPER | ROCK CRUSHING | OIL PUMPING | WATER/WASTEWATER TOUGH ENVIRONMENTS. REQUIRE TOUGH PRODUCTS.


    Original
    PDF 500-SG006B-EN-P 500-SG-006A-EN-P 700-HT22AU120 800T-N1 700-HA32A1 800T-N320G 800T-N169 700-HT12AU120 800T-N320R 700-HT12BU120 1494F-P1 800T-N65

    190-CPS40

    Abstract: 380V 415v motor 190-A40 190-MN 190-CPS40D 190-P400R 3 phase, 415v and 45 kw motor 190-P320R 190-P040R contactor 190-a40
    Text: Bulletin 190 — IEC Modular Starter System Table of Contents Selection Guide Description Page Bulletin 190 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    PDF 190-CL1 190-A22C 190-A11/11 190-A11C 190-N3, 190-SG001A-US-P 190-CPS40 380V 415v motor 190-A40 190-MN 190-CPS40D 190-P400R 3 phase, 415v and 45 kw motor 190-P320R 190-P040R contactor 190-a40

    BS3676

    Abstract: Double pole 32A voltage 400- 690V 50HZ 56PBS1 56PA416K 56SW320 56PA516 56PBS2-Stop 56SW316 electrical motor protection catalogue 56SW15
    Text: 56SW Series protected switch Type and meanings 56 SW 58 Pole: "1":1P, "2":2P "1": It denotes self-reset switch for electrical bell "2": It denotes normal double-throw switch Design sequence no. Protected switch Enterprise code 56SW Application Technical specification


    Original
    PDF 56SW581-1 56SW581-2 56SW582-1 56SW582-2 IP54/IP65) BS3676 Double pole 32A voltage 400- 690V 50HZ 56PBS1 56PA416K 56SW320 56PA516 56PBS2-Stop 56SW316 electrical motor protection catalogue 56SW15

    telemecanique contactor catalogue

    Abstract: Telemecanique LC1D1210 GV3M63 LC1D1210 LC1K09 Telemecanique LC1D4011 LC1D4011 LC1-D4011 lc1k0910 lc1d8011
    Text: Telemecanique LH4 simple soft starting April 99 Why choose a Soft Start? Traditional starting methods, whilst ideal for many Electrical problems, such as current peaks and voltage drop on starting, and the need for overly large power supplies to cater for start


    Original
    PDF

    pkz 2

    Abstract: ZM16 motor starter integral 18 3 phase, 415v and 11 kw motor PKZ2 zm16 3 phase, 415v and 45 kw motor control circuit 3 phase, 415v and 45 kw motor PKZ2 motor 415V
    Text: 8485 Issued November 1989 Motor & System Protection PKZ2 Instruction Leaflet RS stock no. 324-261 Figure 1 Remote operator Protective switch Auxiliary contacts + Contact module General A three pole modular system for motor and system protection up to 40A rated current. The basic unit RS stock number 324261 may be matched with a selection of trip blocks, having


    Original
    PDF

    Allen-Bradley 100-k12

    Abstract: 140M-C-ASA11 140m-c-wte 100-KFSD250 100-K09 140M-C-AFA11 100-KFC22 140M-C-WBE 100-KFSV55 100-K05ZJ10
    Text: SELECTION GUIDE BULLETIN 100-K Miniature Modular Control Sytstem 2 Bulletin 100-K, 700-K, 193-K, 140M, 140F IEC Miniature Contactors Selection Overview IEC Miniature Contactors • Bulletin 100/104-K Miniature Contactors Page 4 IEC Miniature Control Relays


    Original
    PDF 100-K 100-K, 700-K, 193-K, 100/104-K 700-K 193-K 100/104-K 100K-SG001A-EN-P Allen-Bradley 100-k12 140M-C-ASA11 140m-c-wte 100-KFSD250 100-K09 140M-C-AFA11 100-KFC22 140M-C-WBE 100-KFSV55 100-K05ZJ10

    bulletin 2193F

    Abstract: 2100-CA001 Allen-Bradley soft starter smc-3 powerflex 753 powerflex 753 programming manual Allen-Bradley soft starter 2193M LOGIX5561 Cutler-Hammer HMCP 4 POLE 1200 AMPS MANUAL CHANGE OVER SWITCH 600V
    Text: CENTERLINE 2100 Motor Control Centers Selection Guide Industry-Leading Motor Control Centers Delivering Safety, Performance and Reliability CENTERLINE® 2100 Motor Control Centers Selection Guide Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2


    Original
    PDF 2100-SG003A-EN-P bulletin 2193F 2100-CA001 Allen-Bradley soft starter smc-3 powerflex 753 powerflex 753 programming manual Allen-Bradley soft starter 2193M LOGIX5561 Cutler-Hammer HMCP 4 POLE 1200 AMPS MANUAL CHANGE OVER SWITCH 600V

    ESSEX Contactor

    Abstract: 3 phase, 415v and 37 kw motor mte contactor coil 32EXS0-D mte overload MAX072 Overload MTE mte contactor 3 phase, 415v and 55 kw motor 3 phase, 415v and 12 kw motor
    Text: C€ Installation Instructions Starters Type: EXSO-D Issue 10 Im STB W^fPACK I EC 947-4-1 Ratings Full load current min. max. Approximate motor ratir g 415V/3PH 240V/1PH AC3 AC3 kW hp kW hp Recommended max. fuse size for short circuit protection A O rderreferences


    OCR Scan
    PDF 32EXS0-D 15V/3PH 40V/1PH ESSEX Contactor 3 phase, 415v and 37 kw motor mte contactor coil mte overload MAX072 Overload MTE mte contactor 3 phase, 415v and 55 kw motor 3 phase, 415v and 12 kw motor