Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ART2800T Search Results

    ART2800T Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Radiation Assured Devices

    Abstract: No abstract text available
    Text: LAMBDA ADVANCED ANALOG INC. λ ART2800T Series Hybrid - High Reliability Radiation Hardened DC/DC Converter DESCRIPTION FEATURES The ART Series of three output DC/DC converters are designed specifically for use in the hostile radiation environments characteristic of space and


    Original
    PDF ART2800T 150mA MIL-PRF-38534 ISO9001 Radiation Assured Devices

    ART2815

    Abstract: 2815T Lambda Advanced Analog 3E12 ART2800T trifilar neutron detector YJ-41305-TC ADC hard radiation
    Text: LAMBDA ADVANCED ANALOG INC. λ ART2800T Series Hybrid - High Reliability Radiation Hardened DC/DC Converter DESCRIPTION FEATURES The ART Series of three output DC/DC converters are designed specifically for use in the hostile radiation environments characteristic of space and


    Original
    PDF ART2800T MIL-STD-975 MIL-STD-1547 MILPRF-38534, 150mA MIL-PRF-38534 ISO9001 ART2815 2815T Lambda Advanced Analog 3E12 trifilar neutron detector YJ-41305-TC ADC hard radiation

    neutron detector

    Abstract: ART2800T AWG21 bergquist ge
    Text: PD - 94530A ARM28XXT SERIES 28V Input, Three Output ADVANCED ANALOG HYBRID - HIGH RELIABILITY 1 MEGA-RAD HARDENED DC/DC CONVERTER Description The ARM Series of three output DC/DC converters are designed specifically for use in the high-dose radiation environments encountered during deep space planetary missions. The extremely high level of radiation


    Original
    PDF 4530A ARM28XXT neutron detector ART2800T AWG21 bergquist ge

    Untitled

    Abstract: No abstract text available
    Text: PD - 94530B ARM28XXT SERIES 28V Input, Triple Output HYBRID - HIGH RELIABILITY 1 MEGA-RAD HARDENED DC/DC CONVERTER Description The ARM Series of three output DC/DC converters are designed specifically for use in the high-dose radiation environments encountered during deep space planetary


    Original
    PDF 94530B ARM28XXT MIL-PRF-38534.

    IRF LC

    Abstract: smd 2n2907a 2N2222A 15vdc radiation ionizing dose TID detector
    Text: PD - 94530B ARM28XXT SERIES 28V Input, Triple Output HYBRID - HIGH RELIABILITY 1 MEGA-RAD HARDENED DC/DC CONVERTER Description The ARM Series of three output DC/DC converters are designed specifically for use in the high-dose radiation environments encountered during deep space planetary


    Original
    PDF 94530B ARM28XXT MIL-PRF-38534. IRF LC smd 2n2907a 2N2222A 15vdc radiation ionizing dose TID detector

    Lambda Hybrid

    Abstract: neutron detector Lambda Advanced Analog ART2800T LAMBDA linear Voltage Regulator Lambda Pulse Modulator ARM2800T 2N2907A
    Text: LAMBDA ADVANCED ANALOG INC. λ ARM2800T Series Hybrid - High Reliability 1 Mega-Rad Hardened DC/DC Converter DESCRIPTION FEATURES The ARM Series of three output DC/DC converters are intended specifically for use in the high-dose radiation environments encountered during deep


    Original
    PDF ARM2800T 150mA MIL-PRF-38534 ISO9001 Lambda Hybrid neutron detector Lambda Advanced Analog ART2800T LAMBDA linear Voltage Regulator Lambda Pulse Modulator 2N2907A

    radiation ionizing dose TID detector

    Abstract: Lambda POWER Hybrid VOLTAGE REGULATOR
    Text: LAMBDA ADVANCED ANALOG INC. λ PRELIMINARY !"#$%&&' *+,*Hybrid - High Reliability 1 Mega-Rad Hardened DC/DC Converter DESCRIPTION FEATURES The ARM Series of three output DC/DC converters are intended specifically for use in the high-dose radiation environments encountered during deep


    Original
    PDF 150mA MIL-PRF-38534 ISO9001 radiation ionizing dose TID detector Lambda POWER Hybrid VOLTAGE REGULATOR