Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CBJ12 Search Results

    SF Impression Pixel

    CBJ12 Price and Stock

    Amphenol Aerospace PCBJ-12-10PS

    RECEPT
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey PCBJ-12-10PS Bulk 2
    • 1 -
    • 10 $1085.4
    • 100 $1085.4
    • 1000 $1085.4
    • 10000 $1085.4
    Buy Now

    CBJ12 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: 32 Mini-weco Coax circuit board jacks 1.676 1.550 Ø.437 .375 Ø.0625 Ø.070 TYP ±.002 Ø.347 .140 TYP ±.002 Ø.050 Circuit Board Mounting Mini-WECo Coaxial Patch Jack 75Ω .296 Size .280 ±.002 TYP .140 TYP CBJ12 .295 Ø.129 .200 Ø.347 Ø.060 TYP .549


    Original
    PDF CBJ12 CBBJR12 CBBJR12A 500-28UNEF-2A CBJR12 CBJR12A

    Untitled

    Abstract: No abstract text available
    Text: Data Sheet FlatPAC-ENTM EN Compliant, Autoranging Switcher Features • EN 61000-3-2 harmonic current compliance • Low profile package 1.4"/35,6mm • Output power to 500W (425W for EN compliance) • Up to 4 user specifiable outputs • "Autosense" feature


    Original
    PDF MIL-STD-810E RS-232 3/03/10M

    Untitled

    Abstract: No abstract text available
    Text: FlatPAC-EN Design Guide FlatPAC-EN EN Compliant Autoranging Switcher Design Guide and “Quick Install” Instructions www.vicorpower.com Rev. 12/2007 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474 FlatPAC-EN Design Guide


    Original
    PDF

    ericsson RBS 2964 series document

    Abstract: COAXIAL CABLE ERICSSON TZC 500 97 RBS 6201 ericsson ERICSSON TZC 500 97 Ericsson Installation guide for RBS 2116 Ericsson rbs 2964 manual ERICSSON rbs 2409 Ericsson Installation guide for RBS 6201 ERICSSON rbs 3101 ERICSSON tzc 500 32
    Text: 1 Contents RF Interconnect Products Introduction . 2 Trompeter Quality ISO 9001 Registration . 3 Warranty Information . 3


    Original
    PDF Mil-Std-1553B MIL-C-49142 PL375 PL375C PL380 PL455AC PL803 PL3155 PL3155AC ericsson RBS 2964 series document COAXIAL CABLE ERICSSON TZC 500 97 RBS 6201 ericsson ERICSSON TZC 500 97 Ericsson Installation guide for RBS 2116 Ericsson rbs 2964 manual ERICSSON rbs 2409 Ericsson Installation guide for RBS 6201 ERICSSON rbs 3101 ERICSSON tzc 500 32

    ST 78m05

    Abstract: 78M05 ST vicor 5V 400W 230vac 12vdc transformer EN61000-4-4 EN61000-4-5 230 AC to 12V dc circuit 78M05 application note MegaPAC J2 trim and sense lines 230vac to 12vdc converter
    Text: FlatPAC-EN Design Guide FlatPAC-EN EN Compliant Autoranging Switcher Design Guide and “Quick Install” Instructions www.vicorpower.com Rev. 4/2003 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474 FlatPAC-EN Design Guide


    Original
    PDF

    vicor MegaPAC J2 trim and sense lines

    Abstract: VI-J00 16-02-0097 CSB02 EN61000-4-4 EN61000-4-5
    Text: Data Sheet FlatPAC-ENTM EN Compliant, Autoranging Switcher Features • EN61000-3-2 harmonic current compliance • Low profile package 1.4 in/35,6 mm • Output power to 500 W (425 W for EN compliance) • Up to 4 user specifiable outputs • "Autosense" feature


    Original
    PDF EN61000-3-2 in/35 MIL-STD-810E RS-232 vicor MegaPAC J2 trim and sense lines VI-J00 16-02-0097 CSB02 EN61000-4-4 EN61000-4-5

    cbj20

    Abstract: Trompeter Electronics patch panel cbbj159 CBBJR29 Triax* trompeter CBBJR159 Trompeter Electronics CBJR220 CBBJR229 ucbbjr29
    Text: PCB Design Guide 1 Engineering high frequency applications at the board level using rf connectors Sections: High frequency Effects II: PCB Design Guide: managing high frequency on the printed circuit board [Mechanical and chemical fabrication] III: getting the high frequency


    Original
    PDF CBBJR29 cbj20 Trompeter Electronics patch panel cbbj159 Triax* trompeter CBBJR159 Trompeter Electronics CBJR220 CBBJR229 ucbbjr29

    EN61000-4-4

    Abstract: EN61000-4-5 78M05 application note 190VA 205Vdc-390Vdc microcontroller relay change fuse CBJ1-10 M21011
    Text: FlatPAC-EN/EN MI Design Guide FlatPAC-EN and FlatPAC-EN MI EN Compliant Autoranging Switchers Design Guide and “Quick Install” Instructions www.vicorpower.com Rev. 4/2010 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474


    Original
    PDF

    EN61000-3-3

    Abstract: VI-J00
    Text: Data Sheet FlatPAC-EN MITM Rugged COTS Autoranging Switcher Features • EN61000-3-2 harmonic current compliance • Low profile package 1.4 in/35,6 mm • Output power to 500 W (425 W for EN compliance) • Up to 4 user specifiable outputs • "Autosense" feature


    Original
    PDF EN61000-3-2 in/35 MIL-STD-810 RS-232 EN61000-3-3 VI-J00

    linak

    Abstract: linak TR-EM-208-H linak TR-EM-288-H linak TR-EM-273-H linak TR-EM-288-r
    Text: USER MANUAL LI N E AR A C T U AT OR S A N D ELE C T RO N I C S To learn more about LINAK, please visit: www.linak.com Page 1 of 108 Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4


    Original
    PDF MA-M9-02-196-O linak linak TR-EM-208-H linak TR-EM-288-H linak TR-EM-273-H linak TR-EM-288-r

    500w power amplifier circuit diagram

    Abstract: bridge rectifier for 100amps power supply bridge rectifier for 12vdc 100amps CBJ1-12 vicor 400w vicor 5V 400W 230vAC to 24vDC converters circuit 230vac 12vdc transformer T 105 M1 LED EN61000-4-4
    Text: FlatPAC-EN Design Guide FlatPAC-EN EN Compliant Autoranging Switcher Design Guide and “Quick Install” Instructions www.vicorpower.com Rev. 3/2009 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474 FlatPAC-EN Design Guide


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: FlatPAC-EN/EN MI Design Guide FlatPAC-EN and FlatPAC-EN MI EN Compliant Autoranging Switchers Design Guide and “Quick Install” Instructions www.vicorpower.com 03-000050 rev A Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474


    Original
    PDF