Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    E58048 Search Results

    E58048 Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    Untitled

    Abstract: No abstract text available
    Text: High Performance Relays and Power Contactors KILOVAC — Protective Relays DIN Rail or Screw Mounted Voltage Sensitive Relays Paralleling Relays Current Sensitive Relays ANSI/IEEE C37.90-1978 UL File No. E58048 CSA File No. LR61158 DIN EN50022-35 Frequency Sensitive Relays


    Original
    E58048 LR61158 EN50022-35 WD2759-XXX WD2759 PDF

    C37-90

    Abstract: No abstract text available
    Text: Frequency Sensitive Relays WILMAR Protective Relays – WOF & WUF Series Function: 81 O/U • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 Application: The output contacts of frequency relays are energized when the frequency exceeds the adjustable set


    Original
    E58048 LR61158 400Hz. 28VDC C37-90 PDF

    d100

    Abstract: No abstract text available
    Text: Voltage Sensitive Relays WILMAR Protective Relays – D100X Series, Close Differential Function: • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 0.5 Close Differential Relays are voltage sensitive. The pick-up and drop-out voltage settings are independently adjustable, which allows precise setting of the


    Original
    D100X E58048 LR61158 D100-3X D100-4X D100-8X D100-5X D100-7X d100 PDF

    380 volt 50 hz

    Abstract: time curves E58048
    Text: Frequency Sensitive Relays WILMAR Protective Relays – WOUF Series, Over/Underfrequency Function: 81 O/U • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 S TRIP AL S EWS N I R M TER 32 SC #6 - 3 The output contacts of frequency relays are energized when the frequency exceeds the adjustable


    Original
    E58048 LR61158 400Hz. WOUF-12-5060-T Hz400-450 380 volt 50 hz time curves E58048 PDF

    LR61158

    Abstract: E58048
    Text: Frequency Sensitive Relays WILMAR Protective Relays – 20-050-19 Series Voltage/Frequency Function: 27/81 • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 #6 - 32 STUDS 6 PLACES 4 1/2 The output contacts of frequency relays are energized when the frequency exceeds the adjustable set


    Original
    E58048 LR61158 400Hz. 20-050-19X LR61158 E58048 PDF

    "reverse Power Relays"

    Abstract: 723 SAMPLE CIRCUITS
    Text: Reverse Power Relays WILMAR Protective Relays – 700 Series Function: 32 • ANSI/IEEE C37.90-1978 TERMINAL STRIPS #6 - 32 SCREWS • UL file No. E58048 • CSA file No. LR61158 Several types of Reverse Power Relays are available including relays sensitive to reverse reactive power


    Original
    E58048 LR61158 "reverse Power Relays" 723 SAMPLE CIRCUITS PDF

    WSYN

    Abstract: phase angle detector paralleling relay preset Potentiometers 24DC 48DC
    Text: Paralleling Relays WILMAR Protective Relays – WSYN Series Function: 25 • ANSI/IEEE C37.90-1978 TERMINAL STRIPS #6 - 32 SCREWS • UL file No. E58048 • CSA file No. LR61158 Operation: A. The output relay will energize when all three of the following conditions are met:


    Original
    E58048 LR61158 WSYN-50-120-12DC-A 120AC 230AC 380AC 125DC 460AC WSYN phase angle detector paralleling relay preset Potentiometers 24DC 48DC PDF

    SINGLE TURN POTENTIOMETERS

    Abstract: No abstract text available
    Text: Voltage Sensitive Relays WILMAR Protective Relays – WUVT/WOVT Series Function: 27/59 • ANSI/IEEE C37.90-1978 TERMINAL STRIPS #6 - 32 SCREWS • UL file No. E58048 • CSA file No. LR61158 Undervoltage Models - The relay is energized at normal voltage, N.C. contacts will open and N.O.


    Original
    E58048 LR61158 SINGLE TURN POTENTIOMETERS PDF

    WUV-1-120

    Abstract: No abstract text available
    Text: Voltage Sensitive Relays WILMAR Protective Relays – WUV/WOV Series Function: 27/59 • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 TERMINAL STRIPS #6 - 32 SCREWS Voltage sensitive relays are available for both AC and DC applications for over/undervoltage protection.


    Original
    E58048 LR61158 125VDC, WUV-1-120 PDF

    phase failure relay

    Abstract: No abstract text available
    Text: Phase Failure Relays WILMAR Protective Relays – 1000 Series Function: 47 • ANSI/IEEE C37.90-1978 TERMINAL STRIPS #6 - 32 SCREWS • UL file No. E58048 • CSA file No. LR61158 Phase failure relays protect motors, equipment and personnel from damage or injury caused by open


    Original
    E58048 LR61158 1004X phase failure relay PDF

    2110-5K

    Abstract: power transformers fault 1260k
    Text: Ground Fault Relays WILMAR Protective Relays – WGD Series – Floating Ground Function: • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 TERMINAL STRIPS #6 - 32 SCREWS 3.0 WILMAR Ground Fault Detectors are used to sense leakage current to ground in power transformers and generators. They are available for both AC and DC systems.


    Original
    E58048 LR61158 208-120AC 220-120AC 230-120AC 240-120AC 380-120AC 400-120AC 416-120AC 440-120AC 2110-5K power transformers fault 1260k PDF

    CII Technologies relay

    Abstract: en 50022-35 4422 datasheet relay phase control 3 phase voltage relay
    Text: Phase Sequence Relays Kilovac - WD47-XXX Phase Sequence Relay Din Rail Mounting Function: 47 • ANSI/IEEE C37.90-1978 • UL file No. E58048 • DIN EN50022-35 Operation: WD47 Series phase sequence relays are designed to monitor the correct phase rotation and loss of


    Original
    WD47-XXX E58048 EN50022-35 CII Technologies relay en 50022-35 4422 datasheet relay phase control 3 phase voltage relay PDF

    phase failure relay

    Abstract: No abstract text available
    Text: Current Balance Relays WILMAR Protective Relays – WCB Series Function: 60 or 87 • ANSI/IEEE C37.90-1978 TERMINAL STRIPS #6 - 32 SCREWS • UL file No. E58048 • CSA file No. LR61158 Current Balance Relays are designed to sense unbalanced current flow in a three phase system. The


    Original
    E58048 LR61158 phase failure relay PDF

    D101

    Abstract: D101X differential relay D101-6X
    Text: Voltage Sensitive Relays WILMAR Protective Relays – D101X Series, 3 Phase Adjustable, Close Differential Function: • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 #6 - 32 STUDS 10 PLACES Close Differential Relays are voltage sensitive. The


    Original
    D101X E58048 LR61158 D101X D101-6X D101-4X D101-10X D101-7X D101 differential relay D101-6X PDF

    C37-90B

    Abstract: E58048
    Text: Current Sensitive Relays WILMAR Protective Relays – WC1 & WCT1 Series, Overcurrent Function: 50/51 • ANSI/IEEE C37.90-1978 TERMINAL STRIPS #6 - 32 SCREWS • UL file No. E58048 • CSA file No. LR61158 Current sensitive relays are available for single and


    Original
    E58048 LR61158 WCT3-48DC-5A C37-90B E58048 PDF

    "reverse Power Relays"

    Abstract: 700TD 730TD
    Text: Reverse Power Relays WILMAR Protective Relays – 700 Series w/ Adjustable Time Delay Function: 32 • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 TERMINAL STRIPS #6 - 32 SCREWS 3.0 Several types of Reverse Power Relays are available


    Original
    E58048 LR61158 710TD "reverse Power Relays" 700TD 730TD PDF

    500w pioneer power amp circuit diagram

    Abstract: pioneer PAL 010a 500w audio amplifier circuit diagram 500w power amplifier circuit diagram V23148 -B0010-A101 18V circuit diagram electronic ballast for 40W tube 12v 300W AUDIO AMPLIFIER CIRCUIT DIAGRAM ups circuit schematic diagram 1000w PAL 007 pioneer 1000w class d circuit diagram schematics
    Text: Relays, Contactors, Timers, Transformers and Circuit Breakers for General Purpose Industrial & Commercial Applications This technical databook includes specification information for a broad selection of components. Electromechanical relays, contactors, timers, solid state relays, input/output modules, sensors, protective relays,


    Original
    that5-926-55-05 500w pioneer power amp circuit diagram pioneer PAL 010a 500w audio amplifier circuit diagram 500w power amplifier circuit diagram V23148 -B0010-A101 18V circuit diagram electronic ballast for 40W tube 12v 300W AUDIO AMPLIFIER CIRCUIT DIAGRAM ups circuit schematic diagram 1000w PAL 007 pioneer 1000w class d circuit diagram schematics PDF

    500w pioneer power amp circuit diagram

    Abstract: LG color tv Circuit Diagram schematics 500w pioneer power amp circuit diagram schematic schematic DIAGRAM AVR 150 kva GENERATOR Relay schrack RU magnetic Contactor wiring diagrams and float switch schrack V23148 src 06vdc agastat 7022 schematic DIAGRAM AVR 500 kva GENERATOR
    Text: Relays, Contactors, Timers, Transformers and Circuit Breakers For General Purpose Applications TYCO ELECTRONICS CORPORATION WWW.TYCOELECTRONICS.COM Catalog 1308242 Revised 3-03 AGASTAT AXICOM KILOVAC OEG P&B PRODUCTS UNLIMITED SCHRACK Catalog 1308242 Revised 3-03


    Original
    PDF

    Reverse Power Relay

    Abstract: "reverse Power Relays" paralleling relay over current relay relay 112 SPDT DIN rail relay 166 relay 4 change over relays 9 Volt DPDT Relay double change over relay
    Text: Catalog 1308242 Issued 3-03 PDF Rev. 6/07 KILOVAC WD series DIN Rail or Screw Mounted Protective Relays • • • • • • WD25 Paralleling (Synch Check) Relays WD2759 Over/undervoltage Relays WD32 Reverse Power Relays WD47 Phase Sequence Relays WD5051 Single- or Three-Phase Overcurrent Relays


    Original
    WD2759 WD5051 WD81OU E58048 EN50022-35 54VDC 100-200VDC 100-140VAC. Reverse Power Relay "reverse Power Relays" paralleling relay over current relay relay 112 SPDT DIN rail relay 166 relay 4 change over relays 9 Volt DPDT Relay double change over relay PDF

    Untitled

    Abstract: No abstract text available
    Text: ti/ca Voltage Sensitive Relays Electronics W ILMAR Protective Relays - D100X Series, Close Differential Function: ANSI/IEEE C37.90-1978 UL file No. E58048 CSA file No. LR61158 Close Differential Relays are voltage sensitive. The pick-up and drop-out voltage settings are indepen­


    OCR Scan
    D100X E58048 LR61158 200mSec. PDF

    Untitled

    Abstract: No abstract text available
    Text: tijca Paralleling Relays Electronics WILMAR Protective Relays-1 8 00 Series Function: 25 ANSI/IEEE C37.90-1978 UL file No. E58048 CSA file No. LR61158 #6 - 32 STUDS 6 PLACES <§ <£> Application: These relays are designed for automatic paralleling synchronizing of generators. The relays sense the


    OCR Scan
    E58048 LR61158 PDF