Untitled
Abstract: No abstract text available
Text: High Performance Relays and Power Contactors KILOVAC — Protective Relays DIN Rail or Screw Mounted Voltage Sensitive Relays Paralleling Relays Current Sensitive Relays ANSI/IEEE C37.90-1978 UL File No. E58048 CSA File No. LR61158 DIN EN50022-35 Frequency Sensitive Relays
|
Original
|
PDF
|
E58048
LR61158
EN50022-35
WD2759-XXX
WD2759
|
PLC Communication cables pin diagram
Abstract: Carlo 9 pin to 15 PIN wiring DIAGRAM 3491 HFBR-4503 HFBR-4513 fibre optic converter 4503 8 PIN fibre optic pin
Text: Du line Optolink Interface Type G 3491 0090 Fieldbus Installationbus • Interface between Optolinks and PC • RS232 to fibre optics converter • Galvanic isolation 4000 VAC • For mounting on DIN-rail EN50022 • LED-indications for supply • AC power supply
|
Original
|
PDF
|
RS232
EN50022)
25-pin
HFBR-4513
HFBR-4503
PLC Communication cables pin diagram
Carlo
9 pin to 15 PIN wiring DIAGRAM
3491
HFBR-4503
HFBR-4513
fibre optic converter
4503 8 PIN
fibre optic pin
|
166 relay
Abstract: en 50022-35 WD2759-002
Text: Voltage Sensitive Relays Kilovac - WD2759-XXX Over/Undervoltage Function: 27/59 • ANSI/IEEE C37.90-1978 • DIN EN50022-35 • UL Recognized Operation: WD2759 Series ac voltage sensing relays provide voltage monitoring and protection in ac systems from 50 to 400 Hz. Sensing voltages, number of
|
Original
|
PDF
|
WD2759-XXX
EN50022-35
WD2759
166 relay
en 50022-35
WD2759-002
|
en50022
Abstract: pa66 fr RAIL en50022 PA66-GF din mount 35mm PA66 06Nm PCB Layout self COM PA66
Text: Socket SRR8 Panel mount or 35mm DIN Rail EN50022) Mounting Dimension PCB Layout Inter Connection Characteristics Ambient temperature Rated voltage Rated current Insulation voltage Protection degree Socket material Contacts spring material Hold down spring
|
Original
|
PDF
|
EN50022
300VAC
15APer
SelfextinguishingPA66
en50022
pa66 fr
RAIL en50022
PA66-GF
din mount 35mm
PA66
06Nm
PCB Layout
self
COM PA66
|
NES30-24
Abstract: EN50022 NES60-24 NES240-24 RAIL en50022 UL508 VDE0160 NES240-48 IEC1000-3-2 NES120
Text: NES-SERIES DIN rail mountable type 30 ~ 240W Ⅵ Model name NES 120-24 Output voltage Series Output power Ⅵ Features ⅷ DIN rail standard mounting: EN50022-35ן7.5 or 35ן15 ⅷ Universal input: 85 ~ 265VAC continuous input voltage ⅷ Harmonic correction: IEC1000-3-2
|
Original
|
PDF
|
EN50022-357
265VAC
IEC1000-3-2
mm2/24
14AWG.
EN60950/UL1950/CAS950/UL508
100VAC/200VAC
100VAC/200VAC,
EN55022-3515
NES30-24
EN50022
NES60-24
NES240-24
RAIL en50022
UL508
VDE0160
NES240-48
IEC1000-3-2
NES120
|
Untitled
Abstract: No abstract text available
Text: Dupline Field- and Installationbus RS 232 to Optolink Interface Type G 3491 0090 • Interface between Optolinks and PC • RS232 to fibre optics converter • Galvanic isolation 4000 VAC • For mounting on DIN-rail EN50022 • LED-indications for supply
|
Original
|
PDF
|
RS232
EN50022)
25-pin
HFBR-4513
HFBR-4503
|
EN50022
Abstract: pa66-gf 30 EN-50-022 PA66 GF 25 PA66 GF 30 RAIL en50022 PA66-GF SRN4 pa66 fr PA66-GF 25
Text: SRH2-C Panel mount or 35mm Din Rail EN50022 Characteristics Ambient temperature Rated voltage Rated current Insulation voltage Protection degree Socket material Contacts spring material Hold down spring Stew Torque Wire Strip length -40 to 70˚C 300VAC 15A (Per pole)
|
Original
|
PDF
|
EN50022)
300VAC
Self-extinguishing-PA66
32max
SRR11
SRR11/07/08
EN50022
pa66-gf 30
EN-50-022
PA66 GF 25
PA66 GF 30
RAIL en50022
PA66-GF
SRN4
pa66 fr
PA66-GF 25
|
4 change over relays
Abstract: over current relay en 50022-35 overcurrent relay din WD5051-3-XXX WD5051-3-002 CII Technologies relay
Text: Current Sensitive Relays Kilovac - WD5051-3-XXX Over Current Din Rail Mounting Function: 5051 • ANSI/IEEE C37.90-1978 • DIN EN50022-35 • UL Recognized Operation: WD5051-3 Series ac current sensing relays provide current monitoring and protection in ac systems
|
Original
|
PDF
|
WD5051-3-XXX
EN50022-35
WD5051-3
WD5051
4 change over relays
over current relay
en 50022-35
overcurrent relay din
WD5051-3-002
CII Technologies relay
|
en 50022-35
Abstract: CII Technologies relay time delay relay WD81OU-002 CII time delay relay sensitive relay EN50022-35 en50022 DIN Mounting Rail Time Delay
Text: Frequency Sensitive Relay Kilovac - WD81OU-XXX Over/Under Frequency Din Rail Mounting Function: 81 OU • ANSI/IEEE C37.90-1978 • DIN EN50022-35 • UL Recognized Operation: Wilmar WD81OU frequency relays are used to provide frequency monitoring and protection to
|
Original
|
PDF
|
WD81OU-XXX
EN50022-35
WD81OU
en 50022-35
CII Technologies relay
time delay relay
WD81OU-002
CII time delay relay
sensitive relay
EN50022-35
en50022 DIN Mounting Rail
Time Delay
|
en50022
Abstract: pa66 fr PA66 RAIL en50022 PA66-GF din mount 35mm EN-50-022 PCB Layout strip socket SRR11
Text: Socket SRR11 Panel mount or 35mm DIN Rail EN50022) Mounting Dimension PCB Layout Inter Connection Characteristics Ambient temperature Rated voltage Rated current Insulation voltage Protection degree Socket material Contacts spring material Hold down spring
|
Original
|
PDF
|
SRR11
EN50022
300VAC
15APer
SelfextinguishingPA66
en50022
pa66 fr
PA66
RAIL en50022
PA66-GF
din mount 35mm
EN-50-022
PCB Layout
strip socket
SRR11
|
100-FSC280
Abstract: 100-SA10 allen bradley IEC 60947-5-1 TAG 8922 100-FSV136 100-FSV55 VDE 0660 iec 158-1 100-SB10 700S-CF440ZJC 700S-CF440DC
Text: Contactors & Control Relays Safety Control Relays 700S-CF Specifications Conformity to Standards IEC 60947-5-1 IEC 60947-5-1 Annex L — Special Requirements for Mechanically Linked Contact Elements EN50011, EN50005, EN50022 UL 508 VDE 0660 Description Bulletin 700S-CF Safety Control Relays provide mechanically linked,
|
Original
|
PDF
|
700S-CF
EN50011,
EN50005,
EN50022
700S-CF
co180
100S-D210-EI.
100S-D420-EI
100S-D630-EI.
100S-D860-EI
100-FSC280
100-SA10
allen bradley IEC 60947-5-1
TAG 8922
100-FSV136
100-FSV55
VDE 0660 iec 158-1
100-SB10
700S-CF440ZJC
700S-CF440DC
|
CII Technologies relay
Abstract: en 50022-35 4422 datasheet relay phase control 3 phase voltage relay
Text: Phase Sequence Relays Kilovac - WD47-XXX Phase Sequence Relay Din Rail Mounting Function: 47 • ANSI/IEEE C37.90-1978 • UL file No. E58048 • DIN EN50022-35 Operation: WD47 Series phase sequence relays are designed to monitor the correct phase rotation and loss of
|
Original
|
PDF
|
WD47-XXX
E58048
EN50022-35
CII Technologies relay
en 50022-35
4422 datasheet
relay phase control
3 phase voltage relay
|
working of 8 pin relay
Abstract: working of 5 pin relay CS083 CS083N CS113 CS113N relay 8 pin 5 pin relay EN50022 din rail clip
Text: BATTERIES FUSES & FUSEHOLDERS PCB TERMINAL BLOCKS 86 SECTION 9 RELAY BASES Compact 8-11 Pin Commercial Relay Bases Features • Din rail EN50022 or chassis mount ■ Screw driver din release clip ■ Captive washers for ease of wire insertion ■ Accepts fork, ferule and ring terminals (ring for non IP20 only)
|
Original
|
PDF
|
EN50022)
CS083
CS083N
CS113
CS083/N
working of 8 pin relay
working of 5 pin relay
CS083
CS083N
CS113
CS113N
relay 8 pin
5 pin relay
EN50022
din rail clip
|
paralleling relay
Abstract: en 50022-35 dead bus RELAY kilovac 4422 datasheet CII Technologies relay
Text: Paralleling Relays Kilovac - WD25-XXX Paralleling Relay Din Rail Mounting Function: 25 • ANSI/IEEE C37.90-1978 • DIN EN50022-35 • UL Recognized Operation: WD25 paralleling relays are used to ensure that two ac circuits are synchronized. When voltage, phase
|
Original
|
PDF
|
WD25-XXX
EN50022-35
paralleling relay
en 50022-35
dead bus RELAY
kilovac
4422 datasheet
CII Technologies relay
|
|
EN50035
Abstract: 1810-10-XX 1810-15-XX 1811-10-XX 1820-10-XX 1821-10-XX RS-423 TS-35 en50022 DIN Mounting Rail
Text: Features • ■ ■ Low peak clamping voltage even during severe current surges Ability to repeatedly protect against surge currents in excess of 10,000 amperes Convenient mounting and grounding to any flat surface or to Din 1 TS-32 or DIN-3 (TS-35) rail
|
Original
|
PDF
|
TS-32)
TS-35)
8-32UNF-2A
G0303
EN50035
1810-10-XX
1810-15-XX
1811-10-XX
1820-10-XX
1821-10-XX
RS-423
TS-35
en50022 DIN Mounting Rail
|
KL1904
Abstract: til 431 KL6904-FB
Text: Driftsvejledning til KL1904 TwinSAFE indgangsklemme med 4 fejlsikre indgange Version: 1.2.3 Dato: 04.12.2006 Indholdsfortegnelse Indholdsfortegnelse 1 Forord 3 1.1 Oplysninger til manualen 3 1.1.1 Ansvarsbetingelser 3 1.1.2 Leveringsbetingelser 3 1.1.3 Copyright
|
Original
|
PDF
|
KL1904
KL1904
til 431
KL6904-FB
|
bk5120
Abstract: KL6904 BK51 KL91 en iec 60721-3-3
Text: Handleiding voor KL6904 TwinSAFE-Logic-klem met 4 fail-safe uitgangen Versie : 1.1.4 Datum: 04.12.2006 Inhoudsopgave Inhoudsopgave 1 Voorwoord 3 1.1 Aanwijzingen betreffende het handboek 3 1.1.1 Aansprakelijkheidsvoorwaarden 3 1.1.2 Leveringsvoorwaarden 3
|
Original
|
PDF
|
KL6904
bk5120
KL6904
BK51
KL91
en iec 60721-3-3
|
BK3120
Abstract: SENSORES DE PRESION MECANICOS sensores sensor inductivo MANUAL DE COMPONENTES ELECTRONICOS LEUZE asi lumiflex bk31 simbolos de contactos normalmente abiertos ethercat wenglor
Text: Manual de instrucciones para KL1904 Terminal de entrada TwinSAFE con 4 entradas a prueba de fallos Versión: 2.1.0 Fecha: 04.02.2009 Índice Índice 1 Prólogo 1.1 1.2 3 Notas sobre el manual 3 1.1.1 Condiciones de responsabilidad 3 1.1.2 Condiciones de entrega
|
Original
|
PDF
|
KL1904
BK3120
SENSORES DE PRESION MECANICOS
sensores
sensor inductivo
MANUAL DE COMPONENTES ELECTRONICOS
LEUZE asi lumiflex
bk31
simbolos de contactos normalmente abiertos
ethercat
wenglor
|
BK3120
Abstract: No abstract text available
Text: Driftsvejledning til KL2904 TwinSAFE udgangsklemme med 4 fejlsikre udgange Version: 1.1.4 Dato: 04.12.2006 Indholdsfortegnelse Indholdsfortegnelse 1 Forord 1.1 1.2 1.3 2 Oplysninger til manualen 3 1.1.1 Ansvarsbetingelser 3 1.1.2 Leveringsbetingelser 3 1.1.3
|
Original
|
PDF
|
KL2904
BK3120
|
BK3120
Abstract: BK3150 KL2408 KL6201 kl1408 BK3520 siemens elektronik LC3100 PLC programmierung beckhoff Applikation Information
Text: Version: 3.5.1 Datum: 2006-02-10 BK3xx0 - Buskoppler für PROFIBUS-DP Inhaltsverzeichnis Inhaltsverzeichnis BK3xx0 - Buskoppler für PROFIBUS-DP 1. Vorwort Hinweise zur Dokumentation 3 Sicherheitshinweise 4 Ausgabestände der Dokumentation 5 2. Produktübersicht
|
Original
|
PDF
|
|
gsm modem
Abstract: gsm modem sim 900 sim 300 gsm modem simcard sim 900 sim gsm modem circuit diagram sim 300 gsm module module sim 300 gsm modem sim 900 gsm module sim 300 gsm modem datasheet
Text: Du line GSM Modem Type GSM8 Fieldbus Installationbus • GSM modem for Master Generator G38900014 version 3.xx • Surveillance of functions from Master Generator • Controlling of functions to Master Generator • Alarms will be sent as SMS to GSM-phones.
|
Original
|
PDF
|
G38900014
EN50022)
G38900014.
gsm modem
gsm modem sim 900
sim 300 gsm modem
simcard
sim 900
sim gsm modem circuit diagram
sim 300 gsm module
module sim 300 gsm modem
sim 900 gsm module
sim 300 gsm modem datasheet
|
dupline 128
Abstract: M 7401 7401 4420 f 7401 EM4DIN EN50081-1 EN50082-1 G4420 counter Carlo gavazzi
Text: Du line Counter Type G4420 7401 Fieldbus Installationbus • 4 individual counter inputs • Selectable operating mode: Impulse Count or ONtime Summarizing. • Reset feature • 32 multiplexing addresses • Memory in case of power failure • For DIN-rail mounting
|
Original
|
PDF
|
G4420
dupline 128
M 7401
7401
4420
f 7401
EM4DIN
EN50081-1
EN50082-1
counter Carlo gavazzi
|
E45329 for pc
Abstract: E45329 12-pol
Text: IDG-B Kleingehäuse für Industrie- und Gebäudeautomation www.erni.com Katalog D 074597 074518 Ausgabe 3, 03/05 07/09 Ausgabe www.erni.com 1 1 www.erni.com Katalog D 074595 07/09 Ausgabe 1 IDG-B Kleingehäuse Inhaltsverzeichnis Allgemein . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
|
Original
|
PDF
|
23230/USA
E45329 for pc
E45329
12-pol
|
din rail en 50022 - 35x7.5
Abstract: en50022 mounting rail 35x7.5 en 50022-35 lambda power supply 24 NES60-24 RAIL en50022 EN-50-022 Densei-Lambda NES120-24
Text: LAMBDA NES-SERIES DIN rail mountable type 30 ~ 240W DENSEI-LAMBDA Model name NES 120-24 Output voltage Series Output power • Features • • • • DIN rail standard mounting; EN50022-35X7.5 or 35x 15 Universal input: 85 ~ 265VAC continuous input voltage
|
OCR Scan
|
PDF
|
EN50022-35X7
35x15
265VAC
IEC1000-3-2
mm2/24
14AWG.
EN60950/UL1950/CAS950/UL508
NES30-24
NES60-24
NES120-24
din rail en 50022 - 35x7.5
en50022
mounting rail 35x7.5
en 50022-35
lambda power supply 24
RAIL en50022
EN-50-022
Densei-Lambda
|