Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    EN50022 Search Results

    EN50022 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: High Performance Relays and Power Contactors KILOVAC — Protective Relays DIN Rail or Screw Mounted Voltage Sensitive Relays Paralleling Relays Current Sensitive Relays ANSI/IEEE C37.90-1978 UL File No. E58048 CSA File No. LR61158 DIN EN50022-35 Frequency Sensitive Relays


    Original
    PDF E58048 LR61158 EN50022-35 WD2759-XXX WD2759

    PLC Communication cables pin diagram

    Abstract: Carlo 9 pin to 15 PIN wiring DIAGRAM 3491 HFBR-4503 HFBR-4513 fibre optic converter 4503 8 PIN fibre optic pin
    Text: Du line Optolink Interface Type G 3491 0090 Fieldbus Installationbus • Interface between Optolinks and PC • RS232 to fibre optics converter • Galvanic isolation 4000 VAC • For mounting on DIN-rail EN50022 • LED-indications for supply • AC power supply


    Original
    PDF RS232 EN50022) 25-pin HFBR-4513 HFBR-4503 PLC Communication cables pin diagram Carlo 9 pin to 15 PIN wiring DIAGRAM 3491 HFBR-4503 HFBR-4513 fibre optic converter 4503 8 PIN fibre optic pin

    166 relay

    Abstract: en 50022-35 WD2759-002
    Text: Voltage Sensitive Relays Kilovac - WD2759-XXX Over/Undervoltage Function: 27/59 • ANSI/IEEE C37.90-1978 • DIN EN50022-35 • UL Recognized Operation: WD2759 Series ac voltage sensing relays provide voltage monitoring and protection in ac systems from 50 to 400 Hz. Sensing voltages, number of


    Original
    PDF WD2759-XXX EN50022-35 WD2759 166 relay en 50022-35 WD2759-002

    en50022

    Abstract: pa66 fr RAIL en50022 PA66-GF din mount 35mm PA66 06Nm PCB Layout self COM PA66
    Text: Socket SRR8 Panel mount or 35mm DIN Rail EN50022) Mounting Dimension PCB Layout Inter Connection Characteristics Ambient temperature Rated voltage Rated current Insulation voltage Protection degree Socket material Contacts spring material Hold down spring


    Original
    PDF EN50022 300VAC 15APer SelfextinguishingPA66 en50022 pa66 fr RAIL en50022 PA66-GF din mount 35mm PA66 06Nm PCB Layout self COM PA66

    NES30-24

    Abstract: EN50022 NES60-24 NES240-24 RAIL en50022 UL508 VDE0160 NES240-48 IEC1000-3-2 NES120
    Text: NES-SERIES DIN rail mountable type 30 ~ 240W Ⅵ Model name NES 120-24 Output voltage Series Output power Ⅵ Features ⅷ DIN rail standard mounting: EN50022-35‫ן‬7.5 or 35‫ן‬15 ⅷ Universal input: 85 ~ 265VAC continuous input voltage ⅷ Harmonic correction: IEC1000-3-2


    Original
    PDF EN50022-357 265VAC IEC1000-3-2 mm2/24 14AWG. EN60950/UL1950/CAS950/UL508 100VAC/200VAC 100VAC/200VAC, EN55022-3515 NES30-24 EN50022 NES60-24 NES240-24 RAIL en50022 UL508 VDE0160 NES240-48 IEC1000-3-2 NES120

    Untitled

    Abstract: No abstract text available
    Text: Dupline Field- and Installationbus RS 232 to Optolink Interface Type G 3491 0090 • Interface between Optolinks and PC • RS232 to fibre optics converter • Galvanic isolation 4000 VAC • For mounting on DIN-rail EN50022 • LED-indications for supply


    Original
    PDF RS232 EN50022) 25-pin HFBR-4513 HFBR-4503

    EN50022

    Abstract: pa66-gf 30 EN-50-022 PA66 GF 25 PA66 GF 30 RAIL en50022 PA66-GF SRN4 pa66 fr PA66-GF 25
    Text: SRH2-C Panel mount or 35mm Din Rail EN50022 Characteristics Ambient temperature Rated voltage Rated current Insulation voltage Protection degree Socket material Contacts spring material Hold down spring Stew Torque Wire Strip length -40 to 70˚C 300VAC 15A (Per pole)


    Original
    PDF EN50022) 300VAC Self-extinguishing-PA66 32max SRR11 SRR11/07/08 EN50022 pa66-gf 30 EN-50-022 PA66 GF 25 PA66 GF 30 RAIL en50022 PA66-GF SRN4 pa66 fr PA66-GF 25

    4 change over relays

    Abstract: over current relay en 50022-35 overcurrent relay din WD5051-3-XXX WD5051-3-002 CII Technologies relay
    Text: Current Sensitive Relays Kilovac - WD5051-3-XXX Over Current Din Rail Mounting Function: 5051 • ANSI/IEEE C37.90-1978 • DIN EN50022-35 • UL Recognized Operation: WD5051-3 Series ac current sensing relays provide current monitoring and protection in ac systems


    Original
    PDF WD5051-3-XXX EN50022-35 WD5051-3 WD5051 4 change over relays over current relay en 50022-35 overcurrent relay din WD5051-3-002 CII Technologies relay

    en 50022-35

    Abstract: CII Technologies relay time delay relay WD81OU-002 CII time delay relay sensitive relay EN50022-35 en50022 DIN Mounting Rail Time Delay
    Text: Frequency Sensitive Relay Kilovac - WD81OU-XXX Over/Under Frequency Din Rail Mounting Function: 81 OU • ANSI/IEEE C37.90-1978 • DIN EN50022-35 • UL Recognized Operation: Wilmar WD81OU frequency relays are used to provide frequency monitoring and protection to


    Original
    PDF WD81OU-XXX EN50022-35 WD81OU en 50022-35 CII Technologies relay time delay relay WD81OU-002 CII time delay relay sensitive relay EN50022-35 en50022 DIN Mounting Rail Time Delay

    en50022

    Abstract: pa66 fr PA66 RAIL en50022 PA66-GF din mount 35mm EN-50-022 PCB Layout strip socket SRR11
    Text: Socket SRR11 Panel mount or 35mm DIN Rail EN50022) Mounting Dimension PCB Layout Inter Connection Characteristics Ambient temperature Rated voltage Rated current Insulation voltage Protection degree Socket material Contacts spring material Hold down spring


    Original
    PDF SRR11 EN50022 300VAC 15APer SelfextinguishingPA66 en50022 pa66 fr PA66 RAIL en50022 PA66-GF din mount 35mm EN-50-022 PCB Layout strip socket SRR11

    100-FSC280

    Abstract: 100-SA10 allen bradley IEC 60947-5-1 TAG 8922 100-FSV136 100-FSV55 VDE 0660 iec 158-1 100-SB10 700S-CF440ZJC 700S-CF440DC
    Text: Contactors & Control Relays Safety Control Relays 700S-CF Specifications Conformity to Standards IEC 60947-5-1 IEC 60947-5-1 Annex L — Special Requirements for Mechanically Linked Contact Elements EN50011, EN50005, EN50022 UL 508 VDE 0660 Description Bulletin 700S-CF Safety Control Relays provide mechanically linked,


    Original
    PDF 700S-CF EN50011, EN50005, EN50022 700S-CF co180 100S-D210-EI. 100S-D420-EI 100S-D630-EI. 100S-D860-EI 100-FSC280 100-SA10 allen bradley IEC 60947-5-1 TAG 8922 100-FSV136 100-FSV55 VDE 0660 iec 158-1 100-SB10 700S-CF440ZJC 700S-CF440DC

    CII Technologies relay

    Abstract: en 50022-35 4422 datasheet relay phase control 3 phase voltage relay
    Text: Phase Sequence Relays Kilovac - WD47-XXX Phase Sequence Relay Din Rail Mounting Function: 47 • ANSI/IEEE C37.90-1978 • UL file No. E58048 • DIN EN50022-35 Operation: WD47 Series phase sequence relays are designed to monitor the correct phase rotation and loss of


    Original
    PDF WD47-XXX E58048 EN50022-35 CII Technologies relay en 50022-35 4422 datasheet relay phase control 3 phase voltage relay

    working of 8 pin relay

    Abstract: working of 5 pin relay CS083 CS083N CS113 CS113N relay 8 pin 5 pin relay EN50022 din rail clip
    Text: BATTERIES FUSES & FUSEHOLDERS PCB TERMINAL BLOCKS 86 SECTION 9 RELAY BASES Compact 8-11 Pin Commercial Relay Bases Features • Din rail EN50022 or chassis mount ■ Screw driver din release clip ■ Captive washers for ease of wire insertion ■ Accepts fork, ferule and ring terminals (ring for non IP20 only)


    Original
    PDF EN50022) CS083 CS083N CS113 CS083/N working of 8 pin relay working of 5 pin relay CS083 CS083N CS113 CS113N relay 8 pin 5 pin relay EN50022 din rail clip

    paralleling relay

    Abstract: en 50022-35 dead bus RELAY kilovac 4422 datasheet CII Technologies relay
    Text: Paralleling Relays Kilovac - WD25-XXX Paralleling Relay Din Rail Mounting Function: 25 • ANSI/IEEE C37.90-1978 • DIN EN50022-35 • UL Recognized Operation: WD25 paralleling relays are used to ensure that two ac circuits are synchronized. When voltage, phase


    Original
    PDF WD25-XXX EN50022-35 paralleling relay en 50022-35 dead bus RELAY kilovac 4422 datasheet CII Technologies relay

    EN50035

    Abstract: 1810-10-XX 1810-15-XX 1811-10-XX 1820-10-XX 1821-10-XX RS-423 TS-35 en50022 DIN Mounting Rail
    Text: Features • ■ ■ Low peak clamping voltage even during severe current surges Ability to repeatedly protect against surge currents in excess of 10,000 amperes Convenient mounting and grounding to any flat surface or to Din 1 TS-32 or DIN-3 (TS-35) rail


    Original
    PDF TS-32) TS-35) 8-32UNF-2A G0303 EN50035 1810-10-XX 1810-15-XX 1811-10-XX 1820-10-XX 1821-10-XX RS-423 TS-35 en50022 DIN Mounting Rail

    KL1904

    Abstract: til 431 KL6904-FB
    Text: Driftsvejledning til KL1904 TwinSAFE indgangsklemme med 4 fejlsikre indgange Version: 1.2.3 Dato: 04.12.2006 Indholdsfortegnelse Indholdsfortegnelse 1 Forord 3 1.1 Oplysninger til manualen 3 1.1.1 Ansvarsbetingelser 3 1.1.2 Leveringsbetingelser 3 1.1.3 Copyright


    Original
    PDF KL1904 KL1904 til 431 KL6904-FB

    bk5120

    Abstract: KL6904 BK51 KL91 en iec 60721-3-3
    Text: Handleiding voor KL6904 TwinSAFE-Logic-klem met 4 fail-safe uitgangen Versie : 1.1.4 Datum: 04.12.2006 Inhoudsopgave Inhoudsopgave 1 Voorwoord 3 1.1 Aanwijzingen betreffende het handboek 3 1.1.1 Aansprakelijkheidsvoorwaarden 3 1.1.2 Leveringsvoorwaarden 3


    Original
    PDF KL6904 bk5120 KL6904 BK51 KL91 en iec 60721-3-3

    BK3120

    Abstract: SENSORES DE PRESION MECANICOS sensores sensor inductivo MANUAL DE COMPONENTES ELECTRONICOS LEUZE asi lumiflex bk31 simbolos de contactos normalmente abiertos ethercat wenglor
    Text: Manual de instrucciones para KL1904 Terminal de entrada TwinSAFE con 4 entradas a prueba de fallos Versión: 2.1.0 Fecha: 04.02.2009 Índice Índice 1 Prólogo 1.1 1.2 3 Notas sobre el manual 3 1.1.1 Condiciones de responsabilidad 3 1.1.2 Condiciones de entrega


    Original
    PDF KL1904 BK3120 SENSORES DE PRESION MECANICOS sensores sensor inductivo MANUAL DE COMPONENTES ELECTRONICOS LEUZE asi lumiflex bk31 simbolos de contactos normalmente abiertos ethercat wenglor

    BK3120

    Abstract: No abstract text available
    Text: Driftsvejledning til KL2904 TwinSAFE udgangsklemme med 4 fejlsikre udgange Version: 1.1.4 Dato: 04.12.2006 Indholdsfortegnelse Indholdsfortegnelse 1 Forord 1.1 1.2 1.3 2 Oplysninger til manualen 3 1.1.1 Ansvarsbetingelser 3 1.1.2 Leveringsbetingelser 3 1.1.3


    Original
    PDF KL2904 BK3120

    BK3120

    Abstract: BK3150 KL2408 KL6201 kl1408 BK3520 siemens elektronik LC3100 PLC programmierung beckhoff Applikation Information
    Text: Version: 3.5.1 Datum: 2006-02-10 BK3xx0 - Buskoppler für PROFIBUS-DP Inhaltsverzeichnis Inhaltsverzeichnis BK3xx0 - Buskoppler für PROFIBUS-DP 1. Vorwort Hinweise zur Dokumentation 3 Sicherheitshinweise 4 Ausgabestände der Dokumentation 5 2. Produktübersicht


    Original
    PDF

    gsm modem

    Abstract: gsm modem sim 900 sim 300 gsm modem simcard sim 900 sim gsm modem circuit diagram sim 300 gsm module module sim 300 gsm modem sim 900 gsm module sim 300 gsm modem datasheet
    Text: Du line GSM Modem Type GSM8 Fieldbus Installationbus • GSM modem for Master Generator G38900014 version 3.xx • Surveillance of functions from Master Generator • Controlling of functions to Master Generator • Alarms will be sent as SMS to GSM-phones.


    Original
    PDF G38900014 EN50022) G38900014. gsm modem gsm modem sim 900 sim 300 gsm modem simcard sim 900 sim gsm modem circuit diagram sim 300 gsm module module sim 300 gsm modem sim 900 gsm module sim 300 gsm modem datasheet

    dupline 128

    Abstract: M 7401 7401 4420 f 7401 EM4DIN EN50081-1 EN50082-1 G4420 counter Carlo gavazzi
    Text: Du line Counter Type G4420 7401 Fieldbus Installationbus • 4 individual counter inputs • Selectable operating mode: Impulse Count or ONtime Summarizing. • Reset feature • 32 multiplexing addresses • Memory in case of power failure • For DIN-rail mounting


    Original
    PDF G4420 dupline 128 M 7401 7401 4420 f 7401 EM4DIN EN50081-1 EN50082-1 counter Carlo gavazzi

    E45329 for pc

    Abstract: E45329 12-pol
    Text: IDG-B Kleingehäuse für Industrie- und Gebäudeautomation www.erni.com Katalog D 074597 074518 Ausgabe 3, 03/05 07/09 Ausgabe www.erni.com 1 1 www.erni.com Katalog D 074595 07/09 Ausgabe 1 IDG-B Kleingehäuse Inhaltsverzeichnis Allgemein . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2


    Original
    PDF 23230/USA E45329 for pc E45329 12-pol

    din rail en 50022 - 35x7.5

    Abstract: en50022 mounting rail 35x7.5 en 50022-35 lambda power supply 24 NES60-24 RAIL en50022 EN-50-022 Densei-Lambda NES120-24
    Text: LAMBDA NES-SERIES DIN rail mountable type 30 ~ 240W DENSEI-LAMBDA Model name NES 120-24 Output voltage Series Output power • Features • • • • DIN rail standard mounting; EN50022-35X7.5 or 35x 15 Universal input: 85 ~ 265VAC continuous input voltage


    OCR Scan
    PDF EN50022-35X7 35x15 265VAC IEC1000-3-2 mm2/24 14AWG. EN60950/UL1950/CAS950/UL508 NES30-24 NES60-24 NES120-24 din rail en 50022 - 35x7.5 en50022 mounting rail 35x7.5 en 50022-35 lambda power supply 24 RAIL en50022 EN-50-022 Densei-Lambda