Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ABL SURSUM 240 Search Results

    ABL SURSUM 240 Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    nec a1600

    Abstract: ABL SURSUM mccb circuit breaker FI440 FI22.03Y 220-240V
    Text: Altech Corp. Circuit Protection Devices MA Three Phase Adjustable Circuit Breakers Ñ 35 mm DIN Rail Mount The Altech/ABL SURSUM MA holds through starting and inrush currents of three phase transformers, lighting, power supplies and motors including the new high efficiency motors yet


    Original
    CAN/CSA-C22 calibrate25 nec a1600 ABL SURSUM mccb circuit breaker FI440 FI22.03Y 220-240V PDF

    NEC A1600

    Abstract: a1600 NEC a 4504 mccb circuit breaker ABL SURSUM VDE 0106 PART 100 MA1.6U FI22.03Y mccb DATASHEET RK512
    Text: Altech Corp. Circuit Protection Devices MA Three Phase Adjustable Circuit Breakers — 35 mm DIN Rail Mount The Altech/ABL SURSUM MA holds through starting and inrush currents of three phase transformers, lighting, power supplies and motors including the new high efficiency motors yet


    Original
    CAN/CSA-C22 thermal929 NEC A1600 a1600 NEC a 4504 mccb circuit breaker ABL SURSUM VDE 0106 PART 100 MA1.6U FI22.03Y mccb DATASHEET RK512 PDF

    Untitled

    Abstract: No abstract text available
    Text: PIN & SLEEVE DEVICES line of industrial plugs and sockets are manufactured by ABL Sursum, a company well known in Europe for its quality electrical products. This major manufacturer combines the elements of good design, high quality, safety, ease of installation and competitive


    Original
    F51S25A F51S35A F51S55A F51S75A F32S15A F32S25A F32S55A F32S75A F42S05A F42S25A PDF

    ABL SURSUM

    Abstract: MA4.0U NFPA70 MA32U sursum MS063 MA6.3U FI22.03Y FI44.30 Cat fi22.03
    Text: Circuit Protection Devices MA Three Phase Adjustable Circuit Breakers — 35 mm DIN Rail Mount The Altech/ABL SURSUM MA holds through starting and inrush currents of three phase transformers, lighting, power supplies and motors including the new high efficiency motors yet provides tight overload protection, fast half-cycle short-circuit protection, and current/energy let-through protection.


    Original
    CAN/CSA-C22 TR-11CX634A TR-11CX635A TR-11CX636A TR-11CX636 TR-11CX637A TR-11CX638A TR-11CX639A TR-11CX6310A TR-11CX6312A ABL SURSUM MA4.0U NFPA70 MA32U sursum MS063 MA6.3U FI22.03Y FI44.30 Cat fi22.03 PDF

    3C25UL

    Abstract: MS063 43032 3D15UL MA40UM MS025 MA2.5U
    Text: 1307-2012.qxp:QuarkCatalogTempNew 8/31/12 10:41 AM Page 1307 14 Circuit Protection Devices RoHS C UL US LISTED R TEST & MEASUREMENT UL Series UL489 Listed Branch Circuit Breakers INTERCONNECT One Pole Two Pole Three Pole ᭤ Dual Voltage Rating in One Device : 0.3–63 A/240 VAC,


    Original
    UL489 Y/277 MS016 MS025 MS063 3C25UL 43032 3D15UL MA40UM MA2.5U PDF

    Untitled

    Abstract: No abstract text available
    Text: MA- Series Three Phase Adjustable Trip Miniature Circuit Breakers/ Manual Motor Controllers UL508 listed E137938 CAN/CSA-C22.2 No.14 certified The MA was designed to handle the high inrush loads of 3 phase transformers, power supplies, motors, etc. The MA


    Original
    UL508 E137938 CAN/CSA-C22 480Y/277V PDF

    rc 3866

    Abstract: abl sursum mcb type b 160A mccb curve 2CU8 2DNU6 3C63 zytel fr 72 3E63 ABL SURSUM 24V 0.5A ROYAL FUSE
    Text: MINIATURE CIRCUIT BREAKERS MCBs UL Recognized Supplementar y Pr otectors vs. UL Listed Manual Motor Contr ollers D4A D 16A I 277V AC 277V AC 10000 1D4.0 1DU16 I 10kA LISTED 4C87 UL Recognized UL Listed UL Recognized one pole supplementary protector UL Listed one pole manual motor controller


    Original
    1DU16 3P18U3H/6 3P18U3H/9 3P18U3H/12 3P18U3H/18 3P25U3H/6 3P25U3H/9 3P25U3H/12 3P25U3H/18 3P18U3H/24 rc 3866 abl sursum mcb type b 160A mccb curve 2CU8 2DNU6 3C63 zytel fr 72 3E63 ABL SURSUM 24V 0.5A ROYAL FUSE PDF

    shunt trip mccb

    Abstract: 24V 0.5A ROYAL FUSE mccb tripping curve UL508A 28.1 3hp DC motor 220v HP 450 motor 2CU8 ul508a 160A mccb curve iec 947-4-1 400v
    Text: Power Circuit of a UL508A Panel Typical UL508 Application Altech UL508 Disclaimer: This an application example. Installation should be done by a qualified electrician under the guidance of UL/NEC specifications. Altech's V-EA UL508 Manual Motor Controllers


    Original
    UL508A UL508 UL508 E137938 LR104391 480Y/277V 50/60Hz shunt trip mccb 24V 0.5A ROYAL FUSE mccb tripping curve UL508A 28.1 3hp DC motor 220v HP 450 motor 2CU8 160A mccb curve iec 947-4-1 400v PDF

    mcb tripping curves

    Abstract: 60947-2 MAX EARTH LOOP IMPEDANCE US 603U shunt trip mccb VDE0660 2CU8 230v ac to 12v dc without transformer circuit IEC 60947-2 IEC 947 EN60947 48V dc supply FROM 415VAC
    Text: Altech UL1077 Altech UL508 Altech UL489 2 Altech Corp. Expands Itʼs Circuit Breaker line! Altech Corporation, the US market leader in UL508 listed Manual Motor Controllers/Miniature Circuit Breakers, has expanded its circuit protection product line. Altechʼs established line of UL508 listed devices is now being complimented by UL1077


    Original
    UL1077 UL508 UL489 UL508 UL489 UL1077 3A/480Y/277V mcb tripping curves 60947-2 MAX EARTH LOOP IMPEDANCE US 603U shunt trip mccb VDE0660 2CU8 230v ac to 12v dc without transformer circuit IEC 60947-2 IEC 947 EN60947 48V dc supply FROM 415VAC PDF

    Altech v-ea 52

    Abstract: No abstract text available
    Text: V-EA Series UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” • • • • • • DIN Rail Mounted 17.5mm width per pole Thermal Magnetic Current Limiting 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short Circuit Withstand Capacity • Applications Include:


    Original
    UL508 480Y/277V 50/60Hz E137938 LR104391 E983419 N63UM, Altech v-ea 52 PDF