Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    AIR CONDITION Search Results

    AIR CONDITION Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    D1U54T-M-2500-12-HB4C Murata Manufacturing Co Ltd 2.5KW 54MM AC/DC 12V WITH 12VDC STBY BACK TO FRONT AIR Visit Murata Manufacturing Co Ltd
    148-13 Coilcraft Inc Variable Inductor, Air-Core, 7528 Visit Coilcraft Inc Buy
    148-11 Coilcraft Inc Variable Inductor, Air-Core, 7528 Visit Coilcraft Inc Buy
    142-08 Coilcraft Inc General Purpose Inductor, 0.357uH, Air-Core, 3838, Visit Coilcraft Inc Buy
    143-10 Coilcraft Inc General Purpose Inductor, 0.438uH, Air-Core, 3838 Visit Coilcraft Inc Buy

    AIR CONDITION Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    SA6453

    Abstract: hoffman enclosures
    Text: Thermal Management: Air Conditioners Air Conditioners Spec-00181 EPH 763 422-2211 FX 422-2600 Air (763) Conditioners Thermal Management Air Conditioners Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. Application Outdoor Air Conditioners provide high-efficiency positive cooling


    Original
    PDF Spec-00181 SA6453 hoffman enclosures

    Siemens PT100 temperature sensor

    Abstract: Siemens PT1000 temperature sensor PT1000 temperature sensor QAM100.3 Siemens PT1000 QAM170.3.50 Siemens duct temperature sensor Resistance characteristic Pt1000 PT100 IEC 751 siemens air temperature sensors
    Text: 1 773 Duct temperature sensors QAM1. Use The sensors are used for acquiring the air temperature in heating, ventilation and air conditioning plants e.g. in supply air, extract air or mixed air ducts . They are designed for use in connection with automation equipment, display and


    Original
    PDF Pt100 QAM100 QAM160 QAM170 CM1N1773en Whe10 1773M01 Siemens PT100 temperature sensor Siemens PT1000 temperature sensor PT1000 temperature sensor QAM100.3 Siemens PT1000 QAM170.3.50 Siemens duct temperature sensor Resistance characteristic Pt1000 PT100 IEC 751 siemens air temperature sensors

    car impact sensor

    Abstract: solar sensor Solar sun sensor sensors used in automobiles bumper solar sensors co2 sensor circuit CO2 SENSOR SUN SENSOR solar photodiodes
    Text: Application Note Sensors for Air-conditioning in Automobiles www.epcos.com Notes Application Note Sensors for air-conditioning in automobiles Contents Sensors for air-conditioning in


    Original
    PDF

    delphi sensor

    Abstract: weight sensor design evaporator color sensor signal conditioning
    Text: SENSORS Delphi Evaporator Air Temperature Sensor Description The Delphi Evaporator Air Temperature EVAP Sensor is a continuous function device that changes resistance inversely to temperature. It measures the air temperature at the heating, ventilation and air conditioning (HVAC) evaporator


    Original
    PDF

    QBM81-3

    Abstract: QBM81-10 Siemens QBM81 QBM81-5 CA1N1589E Differential Pressure siemens 604.15011 siemens QBM81-3 pg11 cable gland IEC529
    Text: 1 Differential Pressure Detector 552 QBM81-. for monitoring of air pressure Differential pressure detector for ventilation and air conditioning systems • For monitoring of air filters, air flow, fan belts • For monitoring of pressure in clean rooms, kitchens etc.


    Original
    PDF QBM81-. CA1N1552E QBM81-3 QBM81-10 Siemens QBM81 QBM81-5 CA1N1589E Differential Pressure siemens 604.15011 siemens QBM81-3 pg11 cable gland IEC529

    AIR FLOW DETECTOR

    Abstract: air flow detector sensor NRP-345 wind velocity sensor
    Text: Air Flow Detector D6A-N Air Flow detector specifically to detect clogged conditions in air filters on servers and other types of computer equipment • Detects the clogged conditions of air filters more efficiently than a conventional time totalling meter


    Original
    PDF NRP-345 AIR FLOW DETECTOR air flow detector sensor wind velocity sensor

    power 220

    Abstract: PTC 100 thermistors ptc heaters
    Text: PTC Thermistors PTC Heaters for Hot Wind Air PTC Heaters for Hot Wind Air ARH Type: This heater used as heat source for hot air heaters and driers can easily make air hot just by passing air. Furthermore, as the calorific power is automatically controlled in accordance with inflow temperature,


    Original
    PDF EUPARH1111A EUPARH1111B EUPARH1111W EUPARH1111A, EUPARH1111B EUPARH1111A/B/W) EUPARH41L1B EUPARH61L1B power 220 PTC 100 thermistors ptc heaters

    ptc heaters

    Abstract: No abstract text available
    Text: PTC Thermistors PTC Heaters for Hot Wind Air PTC Heaters for Hot Wind Air ARH Type: This heater used as heat source for hot air heaters and driers can easily make air hot just by passing air. Furthermore, as the calorific power is automatically controlled in accordance with inflow temperature,


    Original
    PDF

    ptc heaters

    Abstract: ptc heaters for hot wind air PTC heater A705W ptc application note hot water unit heater ptc 09
    Text: PTC Thermistors PTC Heaters for Hot Wind Air PTC Heaters for Hot Wind Air ARH Type: This heater used as heat source for hot air heaters and driers can easily make air hot just by passing air. Furthermore, as the calorific power is automatically controlled in accordance with inflow temperature,


    Original
    PDF

    MVSS302

    Abstract: ASHRAE fpm 250 airflow 3M Purification MVSS-302 air handling unit automotive air filter D5132-04
    Text: 3M High Air Flow HAF Air Filters The open channel construction of 3M High Air Flow (HAF) Air Filters offers low initial airflow resistance while its unique microstructure and electrostatic charge provide effective particle capture and retention. This may translate to fewer filter changeouts, reduced coil cleaning, and/or reduced maintenance


    Original
    PDF

    MAV03K10

    Abstract: MAV04A20 MAV04E20 MAV02N06 mav03d10 MAV03C16 MAV02F10 MAV03K16 mav03 MAV04A10
    Text: Air Dielectric Trimmer Capacitors Air Dielectric Trimmer Capacitors Series MAV The MAV range of air dielectric trimmers are specifically designed for high frequency applications that demand extreme stability and a high 'Q' under severe environmental conditions in a small physical size.


    Original
    PDF MAV04A10 MAV04A20 MAV04A25 MAV04B10 MAV04B20 MAV04B25 MAV04C10 MAV04C20 MAV04C25 MAV04D10 MAV03K10 MAV04E20 MAV02N06 mav03d10 MAV03C16 MAV02F10 MAV03K16 mav03

    Untitled

    Abstract: No abstract text available
    Text: Data Sheet TMA5 Mini-vane Anemometer The TMA5 is a compact, pocket size tool for indoor air quality and HVAC / R technicians measuring Heat / Ventilation / Air conditioning / Refrigeration wind flow and temperature in residential, commercial and industrial air conditioning systems.


    Original
    PDF CR2032 877-AMPROBE

    Untitled

    Abstract: No abstract text available
    Text: Data Sheet TMA5 Mini-vane Anemometer The TMA5 is a compact, pocket size tool for indoor air quality and HVAC / R technicians measuring Heat / Ventilation / Air conditioning / Refrigeration wind flow and temperature in residential, commercial and industrial air conditioning systems.


    Original
    PDF CR2032 877-AMPROBE

    schematic diagram induction heating

    Abstract: induction furnace circuit diagram igbt based induction furnace circuit diagram induction furnace schematic induction furnace 2x8 segment display IGBT PIC MICROCONTROLLER single phase induction motor speed control schematic diagram "induction heating" of induction heating furnace using IGBT schematic diagram induction furnace
    Text: AN861 Smart Air Handler using ProMPT and the PIC18F2539 Author: Jon Burroughs Microchip Technology Inc. INTRODUCTION In many heating, ventilation, and air conditioning HVAC applications, air handler motors are either off, or on at full speed. However, by adding variable speed


    Original
    PDF AN861 PIC18F2539 D-85737 DS00861A-page schematic diagram induction heating induction furnace circuit diagram igbt based induction furnace circuit diagram induction furnace schematic induction furnace 2x8 segment display IGBT PIC MICROCONTROLLER single phase induction motor speed control schematic diagram "induction heating" of induction heating furnace using IGBT schematic diagram induction furnace

    NM24A-SR

    Abstract: No abstract text available
    Text: Technical data sheet Damper actuator NM24A Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 2 m2 • Torque 10 Nm • Nominal voltage AC/DC 24 V


    Original
    PDF NM24A NM24A. NM24A-S. NM24AP5. NM230A. NM230A-S. NM24A-SR. NM230A-SR. NM24A-SR

    SM230A

    Abstract: SM24A-S SM24A-V SM24A-SR T2-SM230A
    Text: Technical data sheet Damper actuator SM230A Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 4 m2 • Torque 20 Nm • Nominal voltage AC 100 . 240 V


    Original
    PDF SM230A SM24A. SM24A-S. SM24AP5. SM24A-SR. SM24A-MF. SM230ASR. SM24A-MP. SM24A-V SM230A-S. SM230A SM24A-S SM24A-SR T2-SM230A

    NM24AP5

    Abstract: NM24A-S
    Text: Technical data sheet Damper actuator NM230A Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 2 m2 • Torque 10 Nm • Nominal voltage AC 100 . 240 V


    Original
    PDF NM230A NM24A. NM24A-S. NM24AP5. NM230A. NM230A-S. NM24A-SR. NM230A-SR. NM24AP5 NM24A-S

    SM24A-SR

    Abstract: T2-SM24A-SR SM230A SM24A-V
    Text: Technical data sheet Damper actuator SM24A-SR Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 4 m2 • Torque 20 Nm • Nominal voltage AC/DC 24 V


    Original
    PDF SM24A-SR SM24A. SM24A-S. SM24AP5. SM24A-SR. SM24A-MF. SM230ASR. SM24A-MP. SM24A-V SM230A-S. SM24A-SR T2-SM24A-SR SM230A

    EN 60730-1

    Abstract: No abstract text available
    Text: Technical data sheet GM24A-SR Modulating damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 8 m2 • Torque 40 Nm • Nominal voltage AC/DC 24 V


    Original
    PDF GM24A-SR GM24A. GM230A. GM24A-SR. GM24A-MF. GM24A-MP. GM24A-V SM24A-V GM230A-V EN 60730-1

    LM24A-S

    Abstract: EN 60730-1 LM24A LM24AP5
    Text: Technical data sheet Damper actuator LM24A Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 1 m2 • Torque 5 Nm • Nominal voltage AC/DC 24 V


    Original
    PDF LM24A LM24A. LM24A-S. LM24AP5. LM230A. LM230A-S. LM24A-SR. LM230A-SR. LM24A-S EN 60730-1 LM24A LM24AP5

    EN 60730-1

    Abstract: SM230A SM24A SM24A-SR SM230
    Text: Technical data sheet Damper actuator SM24A Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 4 m2 • Torque 20 Nm • Nominal voltage AC/DC 24 V


    Original
    PDF SM24A SM24A. SM24A-S. SM24AP5. SM230A. SM230A-S. SM24A-SR. SM230A-SR. EN 60730-1 SM230A SM24A SM24A-SR SM230

    LM24A-SR

    Abstract: LM24A-S T2-LM24A-SR ZAD24
    Text: Technical data sheet Damper actuator LM24A-SR Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 1 m2 • Torque 5 Nm • Nominal voltage AC/DC 24 V


    Original
    PDF LM24A-SR LM24A. LM24A-S. LM24AP5. LM230A. LM230A-S. LM24A-SR. LM230A-SR. LM24A-SR LM24A-S T2-LM24A-SR ZAD24

    marconi company

    Abstract: marconi BR 161 BR161
    Text: BR 161/FEB. 1955 Triode Type BR 161 HF AMPLIFIER AND OSCILLATOR General. The BR 161 is a forced-air-cooled transmit­ ting triode fitted with a thoriated tungsten filament. Cooling. The anode requires forced air cooling. The air flow and air cooling characteristics given show air


    OCR Scan
    PDF 161/FEB. 5-37P marconi company marconi BR 161 BR161

    marconi company

    Abstract: 0437D-A br179 marconi
    Text: BR 179/FEB. 1955 aironi Triode Type BR 179 General. The BR 179 is a forced-air-cooled transmit­ ting triode fitted with a thoriated tungsten filament. Cooling. The anode requires forced air cooling. The air cooling and air flow characteristics given show the


    OCR Scan
    PDF 179/FEB. marconi company 0437D-A br179 marconi