WATER LEVEL CONTROLLER
Abstract: water level alarm using timer 555 applications Optocoupler with triac circuits ic 555 timer gate drive scr triac scr ntc three phase heater control schematic 3 kw triac UAA2016 infrared based security system using 555 ic water detector using timer 555 sd622 triac static switch
Text: Teccor brand Thyristors Thyristors Used as AC Static Switches and Relays Introduction Since the SCR and the Triac are bistable devices, one of their broad areas of application is in the realm of signal and power switching. This application note describes
|
Original
|
1N4002
Q2008L4
SD622
AN1007
WATER LEVEL CONTROLLER
water level alarm using timer 555 applications
Optocoupler with triac circuits
ic 555 timer gate drive scr
triac scr ntc three phase heater control schematic
3 kw triac UAA2016
infrared based security system using 555 ic
water detector using timer 555
sd622
triac static switch
|
PDF
|
Handling Precautions for Schottky Barrier Mixer and Detector Diodes
Abstract: HIGH VOLTAGE DIODE for microwave ovens induction heater circuit testing of diode METAL DETECTOR circuit for make Microwave detector diodes Microwave Diode burnout RF power
Text: aPPLICATION NOTE Handling Precautions for Schottky Barrier Mixer and Detector Diodes Damage by Burnout from Static Electricity Source of Static Electricity Precautions Operator discharging charge on self through diode Use metal or conductive plastic bench tops and chair seats. Ground operator with
|
Original
|
|
PDF
|
IRF544
Abstract: high side MOSFET driver with charge pump mosfet driver inductive loads Light-Dependent Resistor Light-Dependent charge pump mosfet driver irf5304 4N35 application note mosfet ac switch IRF530
Text: Application Note 1 Micrel Application Note 1 MIC5011 Design Techniques by Mitchell Lee Introduction Power MOSFETs are often preferred over bipolar transistors as high current switches. In static switching applications the MOSFET takes no drive power, where a bipolar transistor
|
Original
|
MIC5011
MIC5011
INPUT100V
74C04
IRF544
high side MOSFET driver with charge pump
mosfet driver inductive loads
Light-Dependent Resistor
Light-Dependent
charge pump mosfet driver
irf5304
4N35 application note
mosfet ac switch
IRF530
|
PDF
|
DT 8211
Abstract: No abstract text available
Text: IPT1206-xxF IP Semiconductor Co., Ltd. High current density due to double mesa technology; SIPOS and Glass Passivation. IPT1206-xx series are suitable for general purpose AC Switching. They can be used as an ON/OFF function In application such as static relays,
|
Original
|
IPT1206-xxF
IPT1206-xx
IPT1206-xxF
DT 8211
|
PDF
|
IPT4006-50H
Abstract: 156 D
Text: IPT4006-xxH IP Semiconductor Co., Ltd. High current density due to double mesa technology; SIPOS and Glass Passivation. IPT4006-50H is suitable for general purpose AC Switching. They can be used as an ON/OFF function In application such as static relays, heating regulation, Induction
|
Original
|
IPT4006-xxH
IPT4006-50H
IPT4006-50H
156 D
|
PDF
|
2839
Abstract: ipt20q06
Text: IPT20Q06-xxB IP Semiconductor Co., Ltd. High current density due to double mesa technology; SIPOS and Glass Passivation. IPT20Q06-xx series are suitable for general purpose AC Switching. They can be used as an ON/OFF function In application such as static relays, heating regulation, Induction
|
Original
|
IPT20Q06-xxB
IPT20Q06-xx
O-220B
2839
ipt20q06
|
PDF
|
2839
Abstract: static relays
Text: IP Semiconductor Co., Ltd. IPT12Q06-xxB High current density due to double mesa technology; SIPOS and Glass Passivation. IPT12Q06-xx series are suitable for general purpose AC Switching. They can be used as an ON/OFF function In application such as static relays, heating regulation, Induction
|
Original
|
IPT12Q06-xxB
IPT12Q06-xx
O-220B
2839
static relays
|
PDF
|
EN60747-5-2
Abstract: motor operated valve KMOC3042
Text: KMOC3042 High Reliability Photocoupler UL 1577 File No.E169586 VDE EN60747-5-2 / EN60950 / EN60065 (File No.40009235) For 115/240 Vac (rms) Application: Outside Dimension:Unit (mm) 1. Solenoid/Valve Controls. 2. Lighting Controls. 3. Static Power Switches.
|
Original
|
KMOC3042
E169586)
EN60747-5-2
EN60950
EN60065
motor operated valve
KMOC3042
|
PDF
|
Untitled
Abstract: No abstract text available
Text: IPT2506-xxA IP Semiconductor Co., Ltd. High current density due to double mesa technology; SIPOS and Glass Passivation. IPT2506-xx series are suitable for general purpose AC Switching. They can be used as an ON/OFF function In application such as static relays, heating regulation, Induction
|
Original
|
IPT2506-xxA
IPT2506-xx
O-220A
|
PDF
|
Untitled
Abstract: No abstract text available
Text: IPT40Q06-xxH IP Semiconductor Co., Ltd. High current density due to double mesa technology; SIPOS and Glass Passivation. IPT40Q06-xx series are suitable for general purpose AC Switching. They can be used as an ON/OFF function In application such as static relays, heating regulation, Induction
|
Original
|
IPT40Q06-xxH
IPT40Q06-xx
IPT25Q06-xxH
|
PDF
|
Untitled
Abstract: No abstract text available
Text: IP Semiconductor Co., Ltd. IPT16Q08-xxB High current density due to double mesa technology; SIPOS and Glass Passivation. IPT16Q08-xx series are suitable for general purpose AC Switching. They can be used as an ON/OFF function In application such as static relays, heating regulation, Induction
|
Original
|
IPT16Q08-xxB
IPT16Q08-xx
O-220B
|
PDF
|
induction heating circuits
Abstract: No abstract text available
Text: IPT2006-xxB IP Semiconductor Co., Ltd. High current density due to double mesa technology; SIPOS and Glass Passivation. IPT2006-xx series are suitable for general purpose AC Switching. They can be used as an ON/OFF function In application such as static relays, heating regulation, Induction
|
Original
|
IPT2006-xxB
IPT2006-xx
IPT2006-xxB
O-220B
induction heating circuits
|
PDF
|
BD269
Abstract: No abstract text available
Text: IPT2008-xxA IP Semiconductor Co., Ltd. High current density due to double mesa technology; SIPOS and Glass Passivation. IPT2008-xx series are suitable for general purpose AC Switching. They can be used as an ON/OFF function In application such as static relays, heating regulation, Induction
|
Original
|
IPT2008-xxA
IPT2008-xx
O-220A
BD269
|
PDF
|
Untitled
Abstract: No abstract text available
Text: IPT1208-xxA IP Semiconductor Co., Ltd. High current density due to double mesa technology; SIPOS and Glass Passivation. IPT1208-xx series are suitable for general purpose AC Switching. They can be used as an ON/OFF function In application such as static relays, heating regulation, Induction
|
Original
|
IPT1208-xxA
IPT1208-xx
IPT1206-xxA
O-220A)
O-220A
|
PDF
|
|
d269
Abstract: No abstract text available
Text: IPT20Q08-xxA IP Semiconductor Co., Ltd. High current density due to double mesa technology; SIPOS and Glass Passivation. IPT20Q08-xx series are suitable for general purpose AC Switching. They can be used as an ON/OFF function In application such as static relays, heating regulation, Induction
|
Original
|
IPT20Q08-xxA
IPT20Q08-xx
IPT20Q08-xxA
O-220A
d269
|
PDF
|
TO-220B
Abstract: static relays
Text: IP Semiconductor Co., Ltd. IPT12Q08-xxB High current density due to double mesa technology; SIPOS and Glass Passivation. IPT12Q08-xx series are suitable for general purpose AC Switching. They can be used as an ON/OFF function In application such as static relays, heating regulation, Induction
|
Original
|
IPT12Q08-xxB
IPT12Q08-xx
O-220B
TO-220B
static relays
|
PDF
|
Untitled
Abstract: No abstract text available
Text: IPT1606-xxA IP Semiconductor Co., Ltd. High current density due to double mesa technology; SIPOS and Glass Passivation. IPT1606-xx series are suitable for general purpose AC Switching. They can be used as an ON/OFF function In application such as static relays, heating regulation, Induction
|
Original
|
IPT1606-xxA
IPT1606-xx
O-220A
|
PDF
|
Untitled
Abstract: No abstract text available
Text: IPT2508-xxA IP Semiconductor Co., Ltd. High current density due to double mesa technology; SIPOS and Glass Passivation. IPT2508-xx series are suitable for general purpose AC Switching. They can be used as an ON/OFF function In application such as static relays, heating regulation, Induction
|
Original
|
IPT2508-xxA
IPT2508-xx
IPT2506-xx
O-220A
|
PDF
|
triac mw 137
Abstract: WPPCT-N546 wppctn546
Text: ISOCOUPLER TM Optoisolators Triac Driver Output 400VPeak , DIP/ SMD/ H WPPCT-N546 Series . USR/CNR Listed (File # 223387) For 115/240 VRMS Application: Outside Dimension: Unit (mm) 1. Solenoid/Valve controls. 2. Lighting controls. 3. Static power switches.
|
Original
|
400VPeak)
WPPCT-N546
DC500V
r031704
triac mw 137
wppctn546
|
PDF
|
triac mw 137
Abstract: n566 Optoisolators with Triac Driver Output smd TRIAC 137 triac catalog WPPCT-N566 smd triac
Text: ISOCOUPLER TM Optoisolators Triac Driver Output 600VPeak , DIP/ SMD/ H WPPCT-N566 Series . USR/CNR Listed (File # 223387) For 115/240 VRMS Application: Outside Dimension: Unit (mm) 1. Solenoid/Valve controls. 2. Lighting controls. 3. Static power switches.
|
Original
|
600VPeak)
WPPCT-N566
DC500V
r031704
triac mw 137
n566
Optoisolators with Triac Driver Output smd
TRIAC 137
triac catalog
smd triac
|
PDF
|
triac mw 137
Abstract: mw 137 WPPCT-N1046
Text: ISOCOUPLER TM Optoisolators Triac Driver Output 400VPeak , DIP/ SMD /H WPPCT-N1046 Series . USR/CNR Listed (File # 223387) For 115/240 VRMS Application: Outside Dimension: Unit (mm) 1. Solenoid/Valve controls. 2. Lighting controls. 3. Static power switches.
|
Original
|
400VPeak)
WPPCT-N1046
r031704
triac mw 137
mw 137
|
PDF
|
triac mw 137
Abstract: 6v 100ohm relay driver mw 137 WPPCT-N1546
Text: ISOCOUPLER TM Optoisolators Triac Drivers Output 400VPeak , DIP/ SMD/ H WPPCT-N1546 Series . USR/CNR Listed (File # 223387) For 115/240 VRMS Application: Outside Dimension: Unit (mm) 1. Solenoid/Valve controls. 2. Lighting controls. 3. Static power switches.
|
Original
|
400VPeak)
WPPCT-N1546
DC500V
r031704
triac mw 137
6v 100ohm relay driver
mw 137
|
PDF
|
excitation system
Abstract: turbo generator transformer 2513 300E J1270 abb generator excitation system generator ragra
Text: ÂSS ASEA BROWN BOVERI ABB Relays Abstract Application Type RAGRA Rotor ground-fault relay for excitation voltages up to 1800 V de • Monitors the ground insulation of rotating or static excitation systems for synchron ous machines • Provides selective ac and dc ground fault
|
OCR Scan
|
80VERI
B03-4014E
514-ABA
B03-1215E
B03-1003E
B03-9510E
B03-9301E
B03-9382E
S-721
excitation system
turbo generator
transformer 2513
300E
J1270
abb generator excitation system generator
ragra
|
PDF
|
cosmo 3022
Abstract: ac Solenoid Driver COSMO ELECTRONICS 3022
Text: PRODUCT SPECIFICATION cosmo Photocoupler ELECTRONICS CO.,LTD. SHEET 1 OF 2 KMOC3022 Optoisolators Triac Driver Output 400V Volts Peak For 115/240 Vac(rms) Application: Solenoid/Valve Controls Lighting Controls Static Power Switches AC Motor Drives Temperature Controls
|
OCR Scan
|
KMOC3022
100mA
DC500V
cosmo 3022
ac Solenoid Driver
COSMO ELECTRONICS 3022
|
PDF
|