Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ASEA EG 10 Search Results

    ASEA EG 10 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    fan motor winding formula

    Abstract: Brown Boveri induction Motor frame IEC-34-1 IEC 34-1 IM3011 m2va IM3001 asea EH 9-10 IM3601 IM1001
    Text: M2000 Aluminium Motors ABB LV Motors M2000 Range ABB Automation Making you more competitive ABB LV Motors knows about customer needs. For over 100 years we have been designing motors for every need and application. With a reputation for quality that is second to none,


    Original
    PDF M2000 24-hour M2000 fan motor winding formula Brown Boveri induction Motor frame IEC-34-1 IEC 34-1 IM3011 m2va IM3001 asea EH 9-10 IM3601 IM1001

    ASEA generator manual

    Abstract: ASEA 34-1 M 160 M 4 asea RK 316 A56A hydropower hydropower plants asea relay RI asea ri relay ASEA E 535 RK 732 - 228
    Text: ASEA IriiO'Mu. RK 549-300 E ' • IINFORMATION R eg. FromrfQato Relay Division . T1TR, September 1977 Edition 1 Paga 5626 1 File RK 00“90 1 Section 5 Frequency relay type TFF 60 o Ability to supervise up to seven frequency levels o Dnder- or overfrequency design


    OCR Scan
    PDF

    asea directional relay

    Abstract: current time tripping curves 60306e directional relay
    Text: ASEA In fo rm a tio n DESCRIPTION OF RELAY PROTECTION R eplaces inform ation 7436 061 E 1 " RFR, Nov., 1965 RK 60-312 E Encl. ; *?435 057-060 52831Y4, 5383 35^ RKL 014 R eg. 7435 1 U nder-im pedance p ro tectio n with d irec tio n a l co m p ariso n p ilo t


    OCR Scan
    PDF 52S3174, asea directional relay current time tripping curves 60306e directional relay

    brown boveri overcurrent relay

    Abstract: RXTUG21H RXVE ASEA overload relay type pt abb combiflex 220V 17A Relay RXTUG 2H B03-9301 BROWN BOVERI thermal overload relay BROWN BOVERI relay
    Text: ASEA BROWN BOVERI v INFORMATION RKU 292 E R eg. 5627 3une IS Edition ABB Relays T herm al o v e rc u rre n t relay type RXVE k fo r filte r re a c to rs o For p ro te c tio n of re a c to rs in SV C -equipm ents o With built in com pensation filte r and rm s-m easu rem en t of


    OCR Scan
    PDF 137i318 95x80 RXTUG21H 093-CA 26-CA 126-CAAil brown boveri overcurrent relay RXVE ASEA overload relay type pt abb combiflex 220V 17A Relay RXTUG 2H B03-9301 BROWN BOVERI thermal overload relay BROWN BOVERI relay

    RK 92-1 E

    Abstract: rK-11 ASEA rrm ASEA I960 asea RRM17
    Text: w rw M ASEA INFORMATION R K 7 0 -3 0 3 E S o lid -state o v e r-c u rre n t re la y type RRTEC 1 R eg. 5623 RELAY DESCRIPTION * e x tre m e ly low o perating power, 20 /iiW • continous setting of operatin g value 0 .5 -2 mA SALIENT F F A lilR ] * b u ilt-u p from so lid -sta te com ponents


    OCR Scan
    PDF

    RK 723 007

    Abstract: DIODE RK 306 SELECTOR SWITCH ASEA ABG RK 795 001-aa RK741 RK717 CATALOGUE SK 63-1 E ASEA ABG 10 RK795 RK70-10E
    Text: C a ta lo g u e R K 70- 10E Edition 1 5930-09 Su persecTes calatog ues R K 7 M O E RK 74-1OE and R K 7 8 -2 E Relay accessories Pushbuttons Component blocks ASEA T h e re lay accesso ries a re used to provide a relay, protective relay or other equip m en t, with


    OCR Scan
    PDF RK70-10E 74-1OE RK78-2E S-721 i960-Â RK 723 007 DIODE RK 306 SELECTOR SWITCH ASEA ABG RK 795 001-aa RK741 RK717 CATALOGUE SK 63-1 E ASEA ABG 10 RK795

    hk relay 12 v

    Abstract: frequency relay frequency relay circuit diagram asea EH HB relay 002-AA EK 110 001-AA rta2
    Text: [nfD-N-D. ASEA TWDRWTTOn F-rom-'DBta HK 545^300 E Ran. IíITi, Maj 1376 Edition 1 5626 Png« 1 File HK 0ÍK90 E Section 5 Frequency relay type KX-b'iil 4 "Will "be replaced "by Catalogue HK 54-10 E , Available in both under— and over-frequency design o


    OCR Scan
    PDF 0CK90 001-AA 002-AA 6O-67 hk relay 12 v frequency relay frequency relay circuit diagram asea EH HB relay EK 110 rta2

    static relays

    Abstract: static overcurrent relays RK736 RK 92-1 E
    Text: j- I ïiîq-Nq. RK 70-304 E m ASEA INFORMATION From /D ste Rçg, RFR, March 1972 Edition 3 Relay Division 5653 Pege 1 Supply devices RRTUB 2 and RRTWC Static relays normally require to be supplied with d-cauxiliary voltage. When connection can not be carried out to


    OCR Scan
    PDF

    RAZOG

    Abstract: Asea low voltage protection relay RXMS about the dc relay DIODE in 5060 RXIH 2 ASEA relay
    Text: Info-N o. ASEA INFORMATION RK 413-300 E From /D ate Reg. Relay Division RFR, April 1970 Edition 1 5623 Page 1 Over-current relay type RXIH 2 Over-current relay RXIH 2 OUTSTANDING FEATURES • is built-up of static components • has out-put matched for a separate output relay


    OCR Scan
    PDF S-721 RAZOG Asea low voltage protection relay RXMS about the dc relay DIODE in 5060 RXIH 2 ASEA relay

    ASEA EG 80

    Abstract: dc tachometer asea over current relay rk 427 ASEA EG 20 relay asea flying shears ASEA over current relay "rk 427" RK 92-1 E
    Text: A S E A IN F O R M A T IO N C 0|M|B i RK 40-313 E If O ilf Integrating device type RREDL 2 with adjustable reference For control of working procedures or processes often methods for integration of measured quantities are applied. A quantity which is the function of a varing measuring signal and time may


    OCR Scan
    PDF

    Relay cf 318 9.0

    Abstract: Relay cf 318 ez 741 DM 311 BG 215CN DM 311 BG 35 AB 314a 741 CN 211-DA msta
    Text: ASEA Catalogue RK 74-10 E E d itio n 1 February 1£¡73 F ija R, P art 1 Component block type RTXE [c|ô|mTbI with diodes, thermistors or resistors • * * * * Requires no extra space To be mounted at the rear o f the relay terminal base The encapsulated block hermetically


    OCR Scan
    PDF

    ASEA over current relay

    Abstract: asea 225 s ASEA relay - RX ASEA relay - RXZ synchronizer 001-AA AN 5891 Data
    Text: A S E A In fo r m a tio n From/Date Relay Division R K 861- 3 0 0 E Reg. RFR Sept. 1973 Edition 2 5891 Page 1 SYNCHRO NIZER TYPE RASA • The permissible frequency difference for synchronizing pulse is settable between 0.2 and 0.4 Hz • The synchronizing pulse is given somewhat prior to exact inphase condition


    OCR Scan
    PDF

    3721 aseg

    Abstract: No abstract text available
    Text: ASEA IKTOHMrlOlíI Fronto'Date REE, Fell. 1574 Edition 1 Relay Division EK 751-500 E Rea. f’íioe 5 É 53 1 Pile EK 00-30 E Section 7 Transient filter type BXT2B 2 Type EXTZB 2 is a LC-filtes that prevents voltage transients to reach electronic circuits when supplied


    OCR Scan
    PDF IKPC53MA 004-AA h--115 3721 aseg

    rpdb

    Abstract: 5624
    Text: A S E A Infor mation R E L A Y DESCRIPTION R F R , Sept. , 1965 RK 5 0 -3 0 0 E R e p la c e s inform ation 5624 006 E a E n c l. R eg . 5624 J 5231 556 j 1 R e ve rs e -po we r relay type R P D B 11 Edition 1 R P D B 11 is a tim e -la g p o w er-d irectio n re la y m ainly intended fo r


    OCR Scan
    PDF

    asea over current relay rk 427

    Abstract: asea over current relay Rxotf rk73-13e asea EG 160 RK 211 037 600020 4S12C asea relay RK732
    Text: Catalogue RK 43-11 E ASEA Edition 1 Three-phase overvoltage and undervoltage relay Type RXOTF 4 Operates both as an overvoltage and an undervoltage relay for single, two and three-phase voltage variations in three-phase networks up to 380 V. Infinitely variable operating values:


    OCR Scan
    PDF 037-AD 301-AD. RK73-13E S-721 asea over current relay rk 427 asea over current relay Rxotf asea EG 160 RK 211 037 600020 4S12C asea relay RK732

    RXSL 1

    Abstract: rk 03 u at timy 13
    Text: ASEA Signal relay type RXSL1 Catalogue RK 27-11 E Ed'Tion 2 N o v e m b e r 1&7J F ile Fr. P a rt 1 cIoTm IZLL 'F iL • r o b u s t e lc c t r a m e c h a n re a l c o n s t r u c tio n - c e s ig n e d fo r d .c . s u p p l y • s h o r t o p e r a t i n g l im e


    OCR Scan
    PDF HB-55V S20-JHJV 92-lOfc. RXSL 1 rk 03 u at timy 13

    transistor LT 5210

    Abstract: RQMB040 PAA 752
    Text: in iC -to. A S t A IHFÖHMAEIÖN Fronu/Date HFE, Nov. 1373 E d itio n 1 Fte!ay Division RK 752-502 E fleg. Pa^a 4S33 1 V oltage s t a b i l i s i n g u n it s ty p e s KQjMB 040 and RQJMB 041 EQMB 040 and RQT5B 041 a re two v o lta g e s t a b i l i s i n g p lu g -in


    OCR Scan
    PDF 221-Lk transistor LT 5210 RQMB040 PAA 752

    BROWN BOVERI Typ STf

    Abstract: BROWN BOVERI relay stf RXDHL BROWN BOVERI stf RADHL BROWN BOVERI relay st rxdhl 4 BROWN BOVERI relay type STF BROWN BOVERI relay differential Brown Boveri SERIES 212
    Text: ABB # * ü l» 1nfO‘Wü. ILK612-301 INFORMATION FiontfDitB Reg. E P4£6 ASEft B R O W N BOVÊRI RFR, January 1978 Edition 1 Relay Division 7434 1 Pile RK 00-90 E Section 6 Pilot-vire differential relay type RADHL for cables and overhead lines _


    OCR Scan
    PDF 00-S0 S-721 BROWN BOVERI Typ STf BROWN BOVERI relay stf RXDHL BROWN BOVERI stf RADHL BROWN BOVERI relay st rxdhl 4 BROWN BOVERI relay type STF BROWN BOVERI relay differential Brown Boveri SERIES 212

    ABB NI 41 Relay settings

    Abstract: asea relay RI RXIC 1 asea rvab ABB NI 40 Relay settings asea rvaa overcurrent relay ASEA RXIL RK 412 RXIL 2 RK426
    Text: JL' |fc I t 1 B RK 487-300 E Pago 1 5627 INFORMATION A S ea b r o w n B o v tR i F fo n V D a te .n n „ , A B B Relays RFR, March 1373 Edition 1 Reg, •Thermal overload relay type RVAB To avoid overloading of a machine, transformer or cattle, a thermal over-current relay can te used to initiate


    OCR Scan
    PDF 487-30C -/77m 15-2S, ABB NI 41 Relay settings asea relay RI RXIC 1 asea rvab ABB NI 40 Relay settings asea rvaa overcurrent relay ASEA RXIL RK 412 RXIL 2 RK426

    ASEA current transformer imbd

    Abstract: ASEA EG 20 ASEA relay - unbalance relay ASEA imbd ASEA unbalance relay asea transformer current ASEA RI asea ri 5A relay
    Text: ASEA INFORMATION Unbalance Protection Type RYBIA RK 60-337 E Reg. 7456 for Series capacitors • DESCRIPTION 07 RELAY PROTECTION ASEA capacitor units consist of a number of parallel connected GENERAL elements each of them in series with a built-in fuse. If a short


    OCR Scan
    PDF 53-8/ul? 53-10yuF ASEA current transformer imbd ASEA EG 20 ASEA relay - unbalance relay ASEA imbd ASEA unbalance relay asea transformer current ASEA RI asea ri 5A relay

    SLCE16

    Abstract: Transformer differential protection RADSE RK 626-101 E 62610-1 795-50OE M9124 ASEA rk 47 asea RADSE RADSE rk 626-101
    Text: Info-No. INFORMATION KK 795-^00 E F ro n V D e te , • Relay Division Rog. January 1975 Edition 2 n 'BFB.f ra ç e 4765 1 File HE 00-90 E Section 6 Reconnectible Ratio Matching Multi-Tapped Auxiliary Current Transformers Type SLCE 12 for Transformer Differential Relays


    OCR Scan
    PDF if-10 795-5O0 f2\/f\10\9\S SLCE16 Transformer differential protection RADSE RK 626-101 E 62610-1 795-50OE M9124 ASEA rk 47 asea RADSE RADSE rk 626-101

    asea rp1

    Abstract: asea EH relays working ASEA protection relay ASEA EG 20 asea directional relay
    Text: FLjr. J. T ype RP 1 s-ijigk-phnse- p g w fi ic la v , 2É32S In selective p ro tec tio n an d re g u latio n , p ow er relay s a te era ployed fo r m any p u rp o se s an d in each in d iv id u al case s p e d a l re q u ire m e n ts m u st be fulfilled •with regard to th e p ro p ertie s o f th ese


    OCR Scan
    PDF -S06- asea rp1 asea EH relays working ASEA protection relay ASEA EG 20 asea directional relay

    RXCE4 ASEA

    Abstract: RXTNB 2 tap control transformer RAYA tap control transformer On-Load Tap changer RXCE 4 ASEA RELAY RTXP 18 resistor 560 Ohms 137-AA
    Text: Catalogue RK 82-10 E ASEA Edition 2 March 1975 File R, Part 1 Voltage regulating relay type RAYA [cIoImIbTT Inverse or independent time-lag characteristics can be chosen with a change-over switch Undervoltage blocking is adjustable between 70 and 90 % of the rated


    OCR Scan
    PDF S-721 RXCE4 ASEA RXTNB 2 tap control transformer RAYA tap control transformer On-Load Tap changer RXCE 4 ASEA RELAY RTXP 18 resistor 560 Ohms 137-AA

    diode catalogue

    Abstract: UL244A asea racib 216B thl 200 mva 011-AA 01-2BA asea directional relay RXPE auk connectors
    Text: A S E A C atalog u e RK 61 -15 E Edition 1 S eptem ber 1981 File R, Part 1 Feeder protection type RACIB The RACIB feed er protection is intended prim arily fo r use in radial-supplied pow er distribution networks. The pro tection c o n ta in s : • A three-phase tim a^overcurrent relay w ith starting,


    OCR Scan
    PDF 012-BA, 012-EA S-721 diode catalogue UL244A asea racib 216B thl 200 mva 011-AA 01-2BA asea directional relay RXPE auk connectors