Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    BIMETAL 16A Search Results

    BIMETAL 16A Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    BCR16FM-12LB#BG0 Renesas Electronics Corporation 600V - 16A - Triac Medium Power Use Visit Renesas Electronics Corporation
    BCR16CM-16LH#BH0 Renesas Electronics Corporation 800V - 16A - Triac Medium Power Use Visit Renesas Electronics Corporation
    BCR16CM-16LB#BH0 Renesas Electronics Corporation 800V - 16A - Triac Medium Power Use Visit Renesas Electronics Corporation
    BCR16CS-16LBA1#BH0 Renesas Electronics Corporation 800V-16A-Triac Medium Power Use Visit Renesas Electronics Corporation
    BCR16RM-12LB#B00 Renesas Electronics Corporation 600V - 16A - Triac Medium Power Use Visit Renesas Electronics Corporation

    BIMETAL 16A Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    Untitled

    Abstract: No abstract text available
    Text: CIRCUIT BREAKERS FOR EQUIPMENT Product description The TS-line consists of a series of low cost thermally operated CBEs available in three frame sizes for rated currents up to 40 A. They are intended to provide protection against sustained overloads. All CBEs of the TS-line use a thermo-bimetal to simulate the thermal


    Original
    TS-701 TS-701 PDF

    Untitled

    Abstract: No abstract text available
    Text: CIRCUIT BREAKERS FOR EQUIPMENT Product description The TS-line consists of a series of low cost thermally operated CBEs available in three frame sizes for rated currents up to 40 A. They are intended to provide protection against sustained overloads. All CBEs of the TS-line use a thermo-bimetal to simulate the thermal


    Original
    TS-709 PDF

    Untitled

    Abstract: No abstract text available
    Text: CIRCUIT BREAKERS FOR EQUIPMENT Product description The TS-line consists of a series of low cost thermally operated CBEs available in three frame sizes for rated currents up to 40 A. They are intended to provide protection against sustained overloads. All CBEs of the TS-line use a thermo-bimetal to simulate the thermal


    Original
    TS-701 TS-701 PDF

    ts 709

    Abstract: No abstract text available
    Text: CIRCUIT BREAKERS FOR EQUIPMENT Product description The TS-line consists of a series of low cost thermally operated CBEs available in three frame sizes for rated currents up to 40 A. They are intended to provide protection against sustained overloads. All CBEs of the TS-line use a thermo-bimetal to simulate the thermal


    Original
    TS-709 ts 709 PDF

    klixon

    Abstract: klixon thermal thermostat klixon klixon Thermostat 75 motor protector klixon klixon 7am klixon motor protector 7AM033 klixon Thermostat 029 klixon
    Text: FEATURES • Miniature size • Current rating up to 22 Amps • Individually temperature calibrated and checked • Positive make and break with Klixon snap-action disc • Reliable temperature performance over life of protector • Gasketed steel case suitable


    Original
    UL3173) klixon klixon thermal thermostat klixon klixon Thermostat 75 motor protector klixon klixon 7am klixon motor protector 7AM033 klixon Thermostat 029 klixon PDF

    Untitled

    Abstract: No abstract text available
    Text: 2 CIRCUIT BREAKERS FOR EQUIPMENT TS-710 Series • Thermal release • Cycling trip-free • Fitting into the mounting cut out of some miniature fuse holders The TS-line consists of a series of low cost thermally operated CBEs available in three frame sizes for rated currents up to 40 A.


    Original
    TS-710 TS-710 PDF

    Untitled

    Abstract: No abstract text available
    Text: 2 CIRCUIT BREAKERS FOR EQUIPMENT TS-709 • Thermal release • Cycling trip-free • Low cost The TS-line consists of a series of low cost thermally operated CBEs available in three frame sizes for rated currents up to 40 A. They are intended to provide protection against sustained overloads.


    Original
    TS-709 PDF

    xapx2

    Abstract: canton AS 65 SC service manual canton AS 50 SC service manual 7AM038 canton AS 105 SC service manual YS11A105B-026 - YS11
    Text: Introduction to Thermtrol Table of Contents www.thermtrol.com E-mail: sales@thermtrol.com Motor Protectors: SH7AM - Self hold motor, transformer, appliance protection 7AM - Motor, lighting, transformer, appliance protection SX8AM - High locked rotor current self hold motor protection


    Original
    TC-100 15AMP xapx2 canton AS 65 SC service manual canton AS 50 SC service manual 7AM038 canton AS 105 SC service manual YS11A105B-026 - YS11 PDF

    2 bimetal thermostat

    Abstract: Thermostat stego VDE THERMOSTAT EN60715 thermostat bimetal 16A stego sensor thermostat storage heaters
    Text: Small, compact Thermostat STO 011 / STS 011 Thumbwheel setting dial Small hysteresis High switching capacity Anti frost assurance Regulating Optimized housing for better air flow The mechanical thermostat is a two state regulator with small hysteresis. The setting wheel has


    Original
    AWG13) 2 bimetal thermostat Thermostat stego VDE THERMOSTAT EN60715 thermostat bimetal 16A stego sensor thermostat storage heaters PDF

    BS3871

    Abstract: BS3871 type 2 B12334 RCBO bimetal
    Text: Issued November 1991 B12334 Residual current circuit breakers with overcurrent protection RCBO Features l l l l l l l l Double pole switching Protects against overcurrent, short-circuit and earth fault currents High shot circuit capacity (3kA) Sensitive to earth fault currents on ac and pulsating


    Original
    B12334 220/240Vac BS3871 BS3871 type 2 B12334 RCBO bimetal PDF

    BS3871

    Abstract: RCBO BS3871 type 2 rcbo type ac Bimetal Circuit breaker MAIN SWITCH BREAKER
    Text: Issued March 1997 232-3513 Data Pack B Data Sheet Residual current circuit breakers with overcurrent protection RCBO Figure 1 Dimensions 17 7.25 10° +- 1° 31.5 - 0.1 20 N 1 N 11.2 + 0.2 18 35 + 0.5 RS stock no. In (A) 6 0.3 490-740 10 0.3 490-756 16 0.3


    Original
    PDF

    BS3871

    Abstract: RCBO bi-metal thermal switch
    Text: Issued November 1991 012-334 Data Pack B Data Sheet Residual current circuit breakers with overcurrent protection RCBO Figure 1 Dimensions 17 7.25 10° +- 1° 31.5 - 0.1 20 N 1 N 11.2 + 0.2 18 35 + 0.5 RS stock no. In (A) 6 0.3 490-740 10 0.3 490-756 16


    Original
    PDF

    BS3871 type 2

    Abstract: BS3871 RCBO bi-metal thermal switch rcbo type ac Bimetal Circuit breaker bs38
    Text: Issued July 1998 291-9883 Data Pack B Residual current circuit breakers with overcurrent protection RCBO Data Sheet Figure 1 Dimensions 36 90 6 90 6 45 44 58 RS stock no. In (A) IÆn (A) 157-9866 6 0.3 157-9872 10 0.3 157-9888 16 0.3 295-4858 20 0.3 157-9894


    Original
    220/240Vac BS3871 type 2 BS3871 RCBO bi-metal thermal switch rcbo type ac Bimetal Circuit breaker bs38 PDF

    Untitled

    Abstract: No abstract text available
    Text: SKS 640F B6HK 430 V16 Electrical Characteristics Symbol Conditions min Electrical Data TAMBIENT = 35°C ; No overload Maximum DC current ID Maximum AC voltage +/-10% VAC DC Bus voltage VBUS PTOTAL Maximum stack power Stack power loss (TAMBIENT = 35°C) PLOSS


    Original
    240VAC 30VDC PDF

    Untitled

    Abstract: No abstract text available
    Text: Extract from the online catalog ELR W1/ 6-24DC Order No.: 2982090 Illustration shows item ELR W1/ 6-24DC Electronic reversing load relay, for driving DC motors, with light indicator and protection circuit, output: 10-30 V DC/6 A


    Original
    6-24DC IF-2009) 6-24DC PDF

    soft starter diagram

    Abstract: POLARITY REVERSING RELAY
    Text: Extract from the online catalog ELR W1/ 6-24DC Order No.: 2982090 Illustration shows item ELR W1/ 6-24DC Electronic reversing load relay, for driving DC motors, with light indicator and protection circuit, output: 10-30 V DC/6 A


    Original
    6-24DC IF-2009) 6-24DC soft starter diagram POLARITY REVERSING RELAY PDF

    Untitled

    Abstract: No abstract text available
    Text: Extract from the online catalog ELR W3/ 9-500 Order No.: 2964186 The illustration shows the version ELR W 3/9-400 Electronic reversing load relay, for direct driving of equipment in the


    Original
    IF-2009) PDF

    Untitled

    Abstract: No abstract text available
    Text: SKS 660F B6U 440 V16 Electrical Characteristics Symbol Conditions min Electrical Data TAMBIENT = 35°C ; No overload Maximum DC current ID Maximum AC voltage +/-10% VAC DC Bus voltage VBUS PTOTAL Maximum stack power Stack power loss (TAMBIENT = 35°C) PLOSS


    Original
    240VAC 30VDC PDF

    Untitled

    Abstract: No abstract text available
    Text: SKS 970F B6C 650 V16 Electrical Characteristics Symbol Conditions min Electrical Data TAMBIENT = 35°C ; No overload Maximum DC current ID Maximum AC voltage +/-10% VAC DC Bus voltage VBUS PTOTAL Maximum stack power Stack power loss (TAMBIENT = 35°C) PLOSS


    Original
    240VAC 30VDC PDF

    Untitled

    Abstract: No abstract text available
    Text: SKS 970F B6HK 650 V16 Electrical Characteristics Symbol Conditions min Electrical Data TAMBIENT = 35°C ; No overload Maximum DC current ID Maximum AC voltage +/-10% VAC DC Bus voltage VBUS PTOTAL Maximum stack power Stack power loss (TAMBIENT = 35°C) PLOSS


    Original
    240VAC 30VDC PDF

    SALZER S225 35 AMP 600 VAC ROTARY CAM SWITCH

    Abstract: salzer s220 salzer RELAY c316fna3 CE15FNS3 salzer T220 salzer T225 Salzer S225 CE15DNS3 CE15ENS3
    Text: ELECTRICAL COMPONENTS Magnetic Starters • Cutler-Hammer quality • Highest HP rating in a compact space saving design • Long-life twin break, silver cadmium oxide contacts provide superior resistance to welding and arc erosion • Din rail mounting Part No.


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: SKS 1220F B6U 820 V16 Electrical Characteristics Symbol Conditions min Electrical Data TAMBIENT = 35°C ; No overload Maximum DC current ID Maximum AC voltage +/-10% VAC DC Bus voltage VBUS PTOTAL Maximum stack power Stack power loss (TAMBIENT = 35°C) PLOSS


    Original
    1220F 240VAC 30VDC PDF

    Untitled

    Abstract: No abstract text available
    Text: SKS 640F B6C 430 V16 Electrical Characteristics Symbol Conditions min Electrical Data TAMBIENT = 35°C ; No overload Maximum DC current ID Maximum AC voltage +/-10% VAC DC Bus voltage VBUS PTOTAL Maximum stack power Stack power loss (TAMBIENT = 35°C) PLOSS


    Original
    240VAC 30VDC PDF

    EN 60730-1

    Abstract: E43273 UL 60730-1 lr67165 bimetal 16A LR67166 bimetal thermostat SF15DUZ-H1-4 15A AC240V
    Text: l/2// Disc Type Thermostat M ÈT Type Automatic Reset Structure Materials of parts M. arm Aluminum Copper Stainless steel Phenolic resin Beryllium Copper alloy Terminals Brass Bracket Contacts Stainless steel Silver-Nickel alloy Case P in Recognized Bimetal


    OCR Scan
    AC120V/15A AC240V/10A AC125V/15A AC250V/8A AC250V/16A EN 60730-1 E43273 UL 60730-1 lr67165 bimetal 16A LR67166 bimetal thermostat SF15DUZ-H1-4 15A AC240V PDF