Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    BLOWN Search Results

    SF Impression Pixel

    BLOWN Price and Stock

    Eaton Cutler-Hammer BLOWNF0001R (ALTERNATE: BLOWNF0001R)

    BLOWN FUSE KIT, 800-4000A | Eaton - Cutler Hammer BLOWNF0001R
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    RS BLOWNF0001R (ALTERNATE: BLOWNF0001R) Bulk 5 Weeks 1
    • 1 $1477.98
    • 10 $1477.98
    • 100 $1477.98
    • 1000 $1477.98
    • 10000 $1477.98
    Get Quote

    Eaton Cutler-Hammer BLOWNF0001R

    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Onlinecomponents.com BLOWNF0001R
    • 1 $1254.19
    • 10 $1168.17
    • 100 $1168.17
    • 1000 $1168.17
    • 10000 $1168.17
    Buy Now

    Littelfuse Inc 03440125H

    Fuse Holder 100-125V 3AG ACS 100-125V
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 03440125H Kit 1,487 1
    • 1 $22.29
    • 10 $20.62
    • 100 $13.67
    • 1000 $13.01
    • 10000 $13.01
    Buy Now
    03440125H Kit 135 1
    • 1 $18.46
    • 10 $17.75
    • 100 $17.06
    • 1000 $16.4
    • 10000 $16.4
    Buy Now

    Littelfuse Inc 03480870Z

    Fuse Holder Black Body Assembly
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 03480870Z Bulk 230 10
    • 1 -
    • 10 $2.95
    • 100 $2.95
    • 1000 $2.95
    • 10000 $2.95
    Buy Now

    Littelfuse Inc 03440250H

    Fuse Holder BLOWN FUSE INDICATING 3AG/3AB
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 03440250H Kit 155 5
    • 1 -
    • 10 $21.17
    • 100 $13.04
    • 1000 $12.41
    • 10000 $12.41
    Buy Now

    BLOWN Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    125OC

    Abstract: UL-94V0 thermal Fuse 2 amp Fuse 2A 94vo Fuse holder littelfuse UL94V0
    Text: Special Application Fuses 481 Series Alarm Indicating Fuse 481 Series Alarm Indicating Fuse Description 481 Series alarm indicating fuses are designed to reduce down time by immediately pinpointing the blown open circuit while triggering an LED or audio alarm. This item


    Original
    PDF E71611 com/series/481 125OC UL-94V0 thermal Fuse 2 amp Fuse 2A 94vo Fuse holder littelfuse UL94V0

    GOA94004C

    Abstract: GOA95004C fan capacitor
    Text: Phone: +39-010-659 1869 Fax: +39-010-659 1870 Web: www.gpsemi.it E-mail: info@gpsemi.it Green Power Solutions srl Via Greto di Cornigliano 6R - 16152 Genova , Italy GOA9xx04C THREE PHASE AC-SWITCH Fuse protection Blown fuse indicators with microswitch Over temperature switches


    Original
    PDF GOA9xx04C GOA94004C GOA95004C GOA9xx04CT002 GOA95004C fan capacitor

    GOG94006C

    Abstract: GOG95006C
    Text: Phone: +39-010-659 1869 Fax: +39-010-659 1870 Web: www.gpsemi.it E-mail: info@gpsemi.it Green Power Solutions srl Via Greto di Cornigliano 6R - 16152 Genova , Italy GOG9xx06C THREE PHASE AC-DC BRIDGE Fuse protection Blown fuse indicators with microswitch Over temperature switches


    Original
    PDF GOG9xx06C GOG94006C GOG95006C GOG9xx06CT002 GOG95006C

    ROUND fuse

    Abstract: No abstract text available
    Text: FUSEHOLDERS FOR 3AG FUSES Blown-Fuse Indicating Panel Mount Type APPROVALS: Recognized under the Components Program of Underwriters Laboratories and Certified by CSA. SPECIFICATIONS: Electrical: Rated at 20 amperes at lamp voltage shown below. Dielectric withstanding voltage exceeds 1500 volts.


    Original
    PDF

    PF544

    Abstract: uplink LINK001C LINK001M LINK002C LINK002M LINK003C LINK003M 800-TEC-FUSE
    Text: Up-LINKTM Remote Indicating Fuseholder Up-LINK Class CC and Midget Fuse Holder Product Benefits • Cost effective solution for remote blown fuse indication • Easily integrates with an existing PLC or system • Data is not shared with a 3rd party • Utilizes reliable solid state circuitry


    Original
    PDF 200kA 100kA 94V0ED PF544 800-TEC-FUSE PF544 uplink LINK001C LINK001M LINK002C LINK002M LINK003C LINK003M 800-TEC-FUSE

    D310020

    Abstract: M085203 B0904 N085204 MC 3E 1-5N C090438 L089388 ttf 103 B087332 900VDC
    Text: 750V DC SQUARE-BODY FUSES /SPECIAL PURPOSE SIZE: 120 Features/Benefits Ratings ➤ 50 to 160 Amps ➤ Blown Fuse indicator ➤ 750vdc at 100kA L/R=100mSec ➤ Square ceramic body ➤ 900vdc at 100kA L/R=40mSec ➤ Full range D.C. operation ➤ Bladed and tapped versions


    Original
    PDF 750vdc 100kA 100mSec 900vdc 40mSec 100ms D310020 M085203 B0904 N085204 MC 3E 1-5N C090438 L089388 ttf 103 B087332

    UL-94-V0 wemid

    Abstract: 0430700000 1012300001
    Text: Datasheet W S I F u s e Te r m i n a l s w i t h L o w C u r re n t S t a t u s I n d i c a t i o n Weidmuller offers versions of the WSI fuse terminals with low current blown fuse indication BFI . The BFI circuit is located in parallel with the fuse so that a current goes through the indicator only when


    Original
    PDF 5x20mm 94-V0 10-36VAC/DC 30-70VAC/DC 60-150VAC/DC 250VAC/110VDC 5/10-LIT0914 UL-94-V0 wemid 0430700000 1012300001

    Untitled

    Abstract: No abstract text available
    Text: Special Application Fuses 481 Series Alarm Indicating Fuse 481 Series Alarm Indicating Fuse Description 481 Series alarm indicating fuses are designed to reduce down time by immediately pinpointing the blown open circuit while triggering an LED or audio alarm. This item


    Original
    PDF E71611

    RA75

    Abstract: No abstract text available
    Text: Relocatable Assembler for 75X, 75XL 4 bit device family This version is restricted to simulate application programs of 512 byte code size maximum. The demo version can be installed by running the program SETUP.EXE in the directory DEMO\75XL\RA75. The order code for the full blown version is RAMSD-I3HD-75X.


    Original
    PDF DEMO\75XL\RA75. RAMSD-I3HD-75X. RA75

    SM78K4

    Abstract: DSWIN-I3HD-784XX
    Text: System Simulator for 78K4 16 bit device family This version is restricted to build application programs of 4kB code size maximum. The demo version can be installed by running the program SETUP.EXE from the directory DEMO\K4\SM78K4 on this CD-ROM. The order code for the full blown version is DSWIN-I3HD-784XX.


    Original
    PDF DEMO\K4\SM78K4 DSWIN-I3HD-784XX. SM78K4 DSWIN-I3HD-784XX

    Fuse holder littelfuse UL94V0

    Abstract: No abstract text available
    Text: Blade Terminal & Special Purpose Fuses 481 Series Alarm Indicating Fuse RoHS 481 Series Alarm Indicating Fuse Description 481 series alarm indicating fuses are designed to reduce down time by immediately pinpointing the blown open circuit while triggering an LED or audio alarm. This item


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses Plain Blades aM Plastic body with/without French striker aM 500V Size 4 from 630 to 1250 A • BLADE-STYLE FUSES: WITH BLOWN FUSE INDICATOR OR TRIP-INDICATOR • COMPLYING WITH IEC 269.1 AND 2.1, NF EN 60269.1 & 2 NF C 63210 - 63211 AND DIN 43620


    Original
    PDF 1900g GPEU59

    Y095126

    Abstract: No abstract text available
    Text: General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses Plain Blades aM Plastic body with/without French striker aM 500V Size 0 and 1 from 40 to 315 A • BLADE-STYLE FUSES: WITH BLOWN FUSE INDICATOR • COMPLYING WITH IEC 269.1 and 2.1 NF EN 60269.1 & 2 NF C 63210 AND DIN 43620 STANDARDS


    Original
    PDF GPEU55 Y095126

    Untitled

    Abstract: No abstract text available
    Text: General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses Plain Blades aM Plastic body with/without French striker aM 500V Size 00 from 16 to 125 A • BLADE-STYLE FUSES: WITH BLOWN FUSE INDICATOR • COMPLYING WITH IEC 269.1 and 2.1 NF EN 60269.1 & 2 NF C 63210 AND DIN 43620 STANDARDS


    Original
    PDF GPEU53

    Untitled

    Abstract: No abstract text available
    Text: 750V DC Square Body Fuses Size: 122 Features/Benefits: •• Blown-fuse indicator •• Square ceramic body •• Full range D.C. operation •• Bladed and tapped versions standard Catalog Numbers, Ratings Current Size Rating IN A IN(A) Maximum l2t Watts Loss


    Original
    PDF A087331 B087332 W221141 L089388 P220951 25x106* Q220952 B090437 M085249 100kA

    Mc 1-5N

    Abstract: M085203
    Text: 750V DC Square Body Fuses Size: 121 Features/Benefits: •• Blown-fuse indicator •• Square ceramic body •• Full range D.C. operation •• Bladed and tapped versions standard Catalog Numbers, Ratings Size Rating IN A 121 Maximum l2t Interrupting


    Original
    PDF A086710 100kA 100ms M085203 N085250 100kAL/R Q085252 Mc 1-5N M085203

    ask 1 ld

    Abstract: No abstract text available
    Text: Circuit Protection Terminals ASK 1 LD ASK 1 W arning: • Install AP partition after last fuse terminal. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which speed identification of fuse failures and reduce costly


    OCR Scan
    PDF

    Fuse T 2.5

    Abstract: No abstract text available
    Text: Circuit Protection Terminals KDKS 1/PE with blown fuse indicator BFI and circuit disconnect Warning: • Install AP partition after last ASK 1 or KDKS 1. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which


    OCR Scan
    PDF

    Fuse 0430900000

    Abstract: thermal fuse vdc 0474560000
    Text: Circuit Protection Terminals ASK 1 combi-foot with blown fuse indicator BFI Warning: and circuit disconnect • Install AP partition after last ASK 1 or KDKS 1. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which


    OCR Scan
    PDF

    TAM fuse

    Abstract: l4 tam
    Text: WSI 6/2 Circuit Protection Terminals with blown fuse indicator Warning: for AC or DC voltage. • Install WAP partition after last WSI 6/2. • Disconnect power before replacing the fuse. Fuse terminals are available with I LED blown fuse indicators, which


    OCR Scan
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Littelfuse Fuseholders For 3AG Fuses Blown-Fuse Indicating Panel Mount Type APPROVALS: Recognized under the Components Program of Underwriters Laboratories and Certified by CSA. ^ QPL ORDERING INFORMATION: Catalog Number SPECIFICATIONS: Electrical: Rated at 20 amperes at lamp voltage shown below.


    OCR Scan
    PDF

    Untitled

    Abstract: No abstract text available
    Text: TM Littelfuse Blade Terminal & Special Purpose Fuses 1 481 Series .w Alarm Indicating Fuse • Ideal for telecommunications and control panel circuits. • Eliminates down time by immediately pinpointing the blown open circuit while triggering LED or audio alarm, while placed in mating


    OCR Scan
    PDF E71611,

    FUSE COVER

    Abstract: 12AWG
    Text: Tension Clamp 35 mm DIN-Rail Terminals Circuit Protection Fuse, Single Level ZSI 2.5/2 with blown fuse indicator For Circuit Breakers, see for AC or DC vottage page 2/20-26 Warning: •Install ZAP TNHE fuse cover plate after last ZSt 2.5/2. •Disconnect power before replac­


    OCR Scan
    PDF 14VDC/10-24 440VAC For13/32x1 00V/3QA/ FUSE COVER 12AWG

    1653350001

    Abstract: Lb 598 d ask 1 ld 35x75
    Text: Screw Clamp 32/35 mm DIN-Rail Terminals Circuit Protection Single Level Fuse ASK 1 ASK 1 LD ASK 1 LD with blown fuse indicator and circuit disconnect Warning: • Install AP partition after last ASK 1 or KDKS 1. • Disconnect power before replacing the fuse.


    OCR Scan
    PDF