Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CELDUC D3 Search Results

    CELDUC D3 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    d41a3

    Abstract: D41A3100
    Text: Pro d i u e G t c u d www.celduc-relais.com celduc MADE IN FRANCE relais 1964-2014 YEARS REED RELAYS AND SWITCHES SOLID STATE RELAYS MAGNETIC SENSORS Dear customers, dear readers, At celducĀ® we are very proud to be celebrating our 50th anniversary in 2014!


    Original
    PDF GUIDUK2014 d41a3 D41A3100

    relais reed celduc

    Abstract: No abstract text available
    Text: Pro d i u e G t c u d www.celduc-relais.com celduc MADE IN FRANCE relais 1964-2014 YEARS REED RELAYS AND SWITCHES SOLID STATE RELAYS MAGNETIC SENSORS Dear customers, dear readers, At celducĀ® we are very proud to be celebrating our 50th anniversary in 2014!


    Original
    PDF GUIDUK2014 relais reed celduc

    D41A3100L

    Abstract: D41A3100 D31A3100L SC868305 SC800030 SEA05022 SL5411 AC05 E69913 SH455100
    Text: NRNT8.E69913 Switches, Industrial Control Certified For Canada - Component Switches, Industrial Control Certified For Canada - Component CELDUC RUE AMPERE BOITE POSTALE 4 42290 SORBIERS, FRANCE E69913 Commercial/Professional grades, miniature , Model AC05.


    Original
    PDF E69913 D31A3100L, -3110L, -3120L, -5100L, -5110L, -5120L, 7100L, -7110L, D41A3100L D41A3100 D31A3100L SC868305 SC800030 SEA05022 SL5411 AC05 E69913 SH455100

    AC05

    Abstract: CM21 SEA05 SC800030 E69913 SC8000 BY306 D31A3100L
    Text: NRNT2.E69913 Switches, Industrial Control - Component Switches, Industrial Control - Component CELDUC RUE AMPERE BOITE POSTALE 4 42290 SORBIERS, FRANCE E69913 Commercial/Professional grades, miniature , Model AC05. Magnetically operated reed switches, Cat. Nos. AI21, CG21, CM21, IA21.


    Original
    PDF E69913 D31A3100L, -3110L, -3120L, -5100L, -5110L, -5120L, 7100L, -7110L, AC05 CM21 SEA05 SC800030 E69913 SC8000 BY306 D31A3100L

    celduc d3

    Abstract: wf210 fly wheel WF070000
    Text: celduc r e l a i S/ACC/ESO02000/B/22/09/08 s PRELIMINARY Page 1/5 UK VOLTAGE PROTECTION FOR DC SOLID-STATE RELAYS ESO02000 u Helps protecting solid-state relays against voltage transient due to the inductive effect of lines and loads. u Clamping function D1 to limit voltage transients across the power


    Original
    PDF S/ACC/ESO02000/B/22/09/08 ESO02000 75VDC UL94V0 IEC60947-1 1L587000 celduc d3 wf210 fly wheel WF070000

    D32A2110

    Abstract: D32A71 relais reed celduc D32A7110 D32A D32A5100 D32A5110 D32-A Celduc Relais d32a D32A2
    Text: D/SEC/D32A*1*0/B/27/12/1999 page 1 / 2 F/GB D32A . 1 . 0 RELAIS REED DUAL IN LINE / deux contacts travail DUAL IN LINE REED RELAY / 2 normally open contacts SCHEMA DE BORNAGE - ENCOMBREMENT / PIN CONFIGURATION - DIMENSIONS 6,6 8 6- 7 1 2+ D 3,3 6,4 9 0,4 19,1


    Original
    PDF D/SEC/D32A 0/B/27/12/1999 D32A2100 D32A2110 D32A5100 D32A5110 D32A7110 100mA D32A2110 D32A71 relais reed celduc D32A7110 D32A D32A5110 D32-A Celduc Relais d32a D32A2

    D31C2140

    Abstract: D31C7100 Celduc Relais RELAIS REED celduc d31c7110 CELDUC GB D31C relais schema d31c5100 D31C5110
    Text: D/SEC/D31C*1*0/B/27/12/1999 page 1 / 2 F/GB D31C . 1 . 0 RELAIS REED DUAL IN LINE / un contact inverseur DUAL IN LINE REED RELAY / 1 contact changeover SCHEMA DE BORNAGE - ENCOMBREMENT / PIN CONFIGURATION - DIMENSIONS 6,6 8 6- 7 1 2+ D 3,3 6,4 E 9 0,4 19,1


    Original
    PDF D/SEC/D31C 0/B/27/12/1999 D31C2100 D31C2140 D31C5100 D31C5110 D31C2140 D31C7100 Celduc Relais RELAIS REED celduc d31c7110 CELDUC GB D31C relais schema

    Celduc D32A2100

    Abstract: D32A2100 d32a5110 Celduc d32a5110 D32A3100-D32A3110 reed relais D32A71 D32A3100 RELAIS REED relais schema
    Text: D/SEC/D32A*1*0/D/30/12/2005 page 1 / 2 F/GB D32A . 1 . 0 RELAIS REED DUAL IN LINE / deux contacts travail DUAL IN LINE REED RELAY / 2 normally open contacts SCHEMA DE BORNAGE - ENCOMBREMENT / PIN CONFIGURATION - DIMENSIONS 6,6 8 6- 7 1 2+ D 3,3 6,4 9 0,4 19,1


    Original
    PDF D/SEC/D32A 0/D/30/12/2005 D32A2100 D32A3100-D32A3110 D32A5100 D32A5110 D32A7110 100mA Celduc D32A2100 d32a5110 Celduc d32a5110 D32A3100-D32A3110 reed relais D32A71 D32A3100 RELAIS REED relais schema

    D31B3140

    Abstract: D31B D31B3100 D31B5100 D31B71 reed relais RELAIS CELDUC D31B3140 D31B3110 D31B5110 D31B7100
    Text: D/SEC/D31B*1*0/B/27/12/1999 page 1 / 2 F/GB D31B . 1 . 0 RELAIS REED DUAL IN LINE / un contact repos DUAL IN LINE REED RELAY / 1 normally closed contact SCHEMA DE BORNAGE - ENCOMBREMENT / PIN CONFIGURATION - DIMENSIONS 6,6 19,1 8 1 2+ D 6- 6,4 E 7 0,4 9 3,3


    Original
    PDF D/SEC/D31B 0/B/27/12/1999 D31B3100 D31B3110 D31B3140 100mA D31B3140 D31B D31B5100 D31B71 reed relais RELAIS CELDUC D31B3140 D31B5110 D31B7100

    D32A2110

    Abstract: D32A2100 SCHEMA D32A5100 D32A5110 D32A7110 D32A21 relais reed celduc D32-A d32a1
    Text: D/SEC/D32A*1*0/C/29/01/2002 page 1 / 2 F/GB D32A . 1 . 0 RELAIS REED DUAL IN LINE / deux contacts travail DUAL IN LINE REED RELAY / 2 normally open contacts SCHEMA DE BORNAGE - ENCOMBREMENT / PIN CONFIGURATION - DIMENSIONS 6,6 8 6- 7 1 2+ D 3,3 6,4 9 0,4 19,1


    Original
    PDF D/SEC/D32A 0/C/29/01/2002 D32A2100 D32A2110 D32A5100 D32A5110 D32A7110 100mA D32A2110 SCHEMA D32A5110 D32A7110 D32A21 relais reed celduc D32-A d32a1

    D31B3100

    Abstract: d31b5100 D31B3110 D31B d31b3140 RELAIS CELDUC D31B3140 D31B51 d31b7100 relais reed D31B5110
    Text: D/SEC/D31B*1*0/C/29/01/2002 page 1 / 2 F/GB D31B . 1 . 0 RELAIS REED DUAL IN LINE / un contact repos DUAL IN LINE REED RELAY / 1 normally closed contact SCHEMA DE BORNAGE - ENCOMBREMENT / PIN CONFIGURATION - DIMENSIONS 6,6 19,1 8 1 2+ D 6- 6,4 E 7 0,4 9 3,3


    Original
    PDF D/SEC/D31B 0/C/29/01/2002 D31B3100 D31B3110 D31B3140 100mA d31b5100 D31B d31b3140 RELAIS CELDUC D31B3140 D31B51 d31b7100 relais reed D31B5110

    D31C

    Abstract: d31c7100 D31C2140 celduc d31c7100 D31C7110 celduc d31c7110 D31C5110 D31C5140 D31C6110 d31c2100
    Text: D/SEC/D31C*1*0/C/29/01/2002 page 1 / 2 F/GB D31C . 1 . 0 RELAIS REED DUAL IN LINE / un contact inverseur DUAL IN LINE REED RELAY / 1 contact changeover SCHEMA DE BORNAGE - ENCOMBREMENT / PIN CONFIGURATION - DIMENSIONS 6,6 8 6- 7 1 2+ D 3,3 6,4 E 9 0,4 19,1


    Original
    PDF D/SEC/D31C 0/C/29/01/2002 D31C2100 D31C2140 D31C5100 D31C d31c7100 D31C2140 celduc d31c7100 D31C7110 celduc d31c7110 D31C5110 D31C5140 D31C6110

    Celduc D31A3100

    Abstract: D31A3100 D31A5100 D31A5110 D31A Celduc Relais D31A D31A3110 d31a7100 celduc D31A5100 d31a7110
    Text: D/SEC/D31A*1*0/E/29/01/2002 page 1 / 2 F/GB D31A . 1 . 0 RELAIS REED DUAL IN LINE / un contact travail DUAL IN LINE REED RELAY / 1 normally open contact SCHEMA DE BORNAGE - ENCOMBREMENT / PIN CONFIGURATION - DIMENSIONS 6,6 19,1 8 1 2+ D 6- 6,4 E 7 0,4 9 3,3


    Original
    PDF D/SEC/D31A 0/E/29/01/2002 100mA Celduc D31A3100 D31A3100 D31A5100 D31A5110 D31A Celduc Relais D31A D31A3110 d31a7100 celduc D31A5100 d31a7110

    95A sensor hall

    Abstract: celduc d31c2110 d31c2110 sensor hall 95A HALL 95A D41A3100L 95A magnetic sensor IGBT ac switch in SSR swt kw 11 7 1 16a 250vac ac SYNCHRONOUS MOTOR WIRING
    Text: Selection Guide REED RELAYS AND SWITCHES MAGNETIC SENSORS SOLID STATE RELAYS IV E ED We are pleased to present the third version of our short form catalogue. The last 3 years have seen a dramatic growth in customers in a diverse range of industries, allowing us to demonstrate high quality, innovative design techniques incorporated in many of the new products shown in this catalogue.


    Original
    PDF

    D31A3100

    Abstract: d31a D31A3110 D31A7100 D31A5100 D31A5110 D31A3140 Celduc D31A3100 d31a5140 d31a7110
    Text: D/SEC/D31A*1*0/D/27/12/1999 page 1 / 2 F/GB D31A . 1 . 0 RELAIS REED DUAL IN LINE / un contact travail DUAL IN LINE REED RELAY / 1 normally open contact SCHEMA DE BORNAGE - ENCOMBREMENT / PIN CONFIGURATION - DIMENSIONS 6,6 19,1 8 1 2+ D 6- 6,4 E 7 0,4 9 3,3


    Original
    PDF D/SEC/D31A 0/D/27/12/1999 100mA D31A3100 d31a D31A3110 D31A7100 D31A5100 D31A5110 D31A3140 Celduc D31A3100 d31a5140 d31a7110

    D31A51

    Abstract: Celduc D31A Celduc Relais D31A D31A D31A1
    Text: D/SEC/D31A*1*0/I/08/09/2014 page 1 / 2 F/GB D31A . 1 . 0 RELAIS REED DUAL IN LINE / un contact travail DUAL IN LINE REED RELAY / 1 normally open contact SCHEMA DE BORNAGE - ENCOMBREMENT/ PIN CONFIGURATION - DIMENSIONS 6,6 19,1 9 8 6,4 14 13 1 2 + D 3,3 E 6 - 7


    Original