connector SB50 anderson
Abstract: anderson SB50 SB50 anderson SB50 cms 25 11 114332S1
Text: 8 5 6 7 1 APPLICATION D 17.6 .69 MINI-VERTICAL POWERCLAW CONTACTS 35.4 1.40 C GUIDE HOUSING 1 REV. C 2 SB50 CONNECTOR 38.5 1.52 ECRN 14249: ADDED MATING LENGTH DATE DESCRIPTION OF CHANGES BY: D CMS 3/26/08 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF
|
Original
|
PDF
|
WIT02
UL94V-0,
CADFILES/01686
114332S4
connector SB50 anderson
anderson SB50
SB50 anderson
SB50
cms 25 11
114332S1
|
anderson SB50
Abstract: No abstract text available
Text: Anderson Power Products ® General Installation Instructions for the Vertical & Horizontal Powerclaw with Guide Housing See reverse side for mounting location/dimensions 1. By applying slight pressure, insert the Vertical Powerclaw contact(s) through the
|
Original
|
PDF
|
1S6401
REV02
anderson SB50
|
SB50-HDL-RED
Abstract: anderson sbs50 SBS50 SBS75X anderson sbs75X anderson SB50 connector SB50 anderson self tapping screws sb50 SB50 anderson
Text: 8 6 7 5 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ANDERSON POWER PRODUCTS. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF ANDERSON POWER PRODUCTS IS PROHIBITED. D 2 SELF-TAPPING SCREWS 3 4 2 1 ANDERSON POWER PRODUCTS RESERVES THE RIGHT TO ALTER PRODUCT TYPES,
|
Original
|
PDF
|
SBS50,
SBS75X)
SBS75X
SB50-HDL-RED)
113923S1
SB50-HDL-RED
anderson sbs50
SBS50
anderson sbs75X
anderson SB50
connector SB50 anderson
self tapping screws
sb50
SB50 anderson
|
Untitled
Abstract: No abstract text available
Text: SB 50 Connectors - up to 120 amps Based off the design pioneered by Anderson in 1953, APP®’s two pole SB® connectors set the standard for DC power distribution and battery connections. SB®50 connectors feature a one piece plastic housing using stainless steel springs to hold low resistance contacts in
|
Original
|
PDF
|
SB175
1303G13
1304G32
1387G1
1387G2
1388G3
1389G3
|
PC5930S
Abstract: MIL-STD-1344, Method 3001 PC5930T PC5930 PC5933S PC5933T PC5934S PC5934T cork material connector SB50 anderson
Text: Powerclaw Anderson Power Products 55 amp PCB Connector ® The innovative design of our Powerclaw family of connectors for the power electronics market makes connecting and disconnecting a snap, enabling safe and convenient "hot swapping*" during equipment maintenance
|
Original
|
PDF
|
LR25154
E26226
REV02
PC5930S
MIL-STD-1344, Method 3001
PC5930T
PC5930
PC5933S
PC5933T
PC5934S
PC5934T
cork material
connector SB50 anderson
|
SB50
Abstract: DS-SB50
Text: SB 50 Connectors - up to 120 amps Based off the design pioneered by Anderson in 1953, APP®’s two pole SB® connectors set the standard for DC power distribution and battery connections. SB®50 connectors feature a one piece plastic housing using stainless steel springs to hold low resistance contacts in
|
Original
|
PDF
|
1388G7
SB120
1319G4
1388G3
1319G6
1323G1
1387G1
1388G4
SB175
300mcm
SB50
DS-SB50
|
SB175 anderson
Abstract: connector SB50 anderson UL-746C united chemical P913 P949 sb175 SB-175 ANDERSON POWER PRODUCTS SB175
Text: Chemical Resistant Anderson Power Products SB Connectors ® The new Chemical Resistant CR SB line of connectors were developed for customers whose applications require robust connector solutions that provide improved resistance to environmental factors that commonly
|
Original
|
PDF
|
g2-3700
SB175 anderson
connector SB50 anderson
UL-746C
united chemical
P913
P949
sb175
SB-175
ANDERSON POWER PRODUCTS SB175
|
UL 486A pull test
Abstract: UL486E table 14.1 UL486e UL 486A pull out test UL486B 1387G1 UL486 1388G4 1388g6 1388G5
Text: CRIMPING INSTRUCTIONS FOR CATALOG # 1387G1 PNEUMATIC CRIMP TOOL The 1387G1 is a heavy-duty pneumatic tool which crimps Anderson contacts with a wire range from #10/12 AWG to 4/0 cable. This tool is either bench mountable or portable and operates off of standard shop air pressure 90 to 125 psi . Interchangeable dies
|
Original
|
PDF
|
1387G1
1387G1
SB50/PP75
PP120
SB175/PP180
SB350
1388G6
UL 486A pull test
UL486E table 14.1
UL486e
UL 486A pull out test
UL486B
UL486
1388G4
1388g6
1388G5
|
1387G1
Abstract: crimping tool by manufacturer THHN WIRE 1S1030 connector SB50 anderson SB175 SB350 981G1 E26226 anderson SB50
Text: SB Connector Assembly Sheet For all models: 50, 120, 175 and 350 amps Two Pole Connectors with Single Piece Housings ASSEMBLY INSTRUCTIONS For installation by a qualified electrician in accordance with national and local electrical codes and the following instruction. The suitability of this type of termination must be
|
Original
|
PDF
|
E26226.
LR25154.
1S1030A
REV15
1387G1
crimping tool by manufacturer
THHN WIRE
1S1030
connector SB50 anderson
SB175
SB350
981G1
E26226
anderson SB50
|
6331G3
Abstract: 6319G1 6331G7 6331G1 6331G2 6331G4 6331G5 6331G6 6331G8 6331G9
Text: SB 50 Anderson Power Products Connector ® The innovative SB® connectors provide costeffective reliability, design flexibility and safety for your products' manufacture, installation and maintenance. APP's 2 pole connector is available with a 50 amp rating, 600 Volts continuous AC or DC
|
Original
|
PDF
|
1309G4
1387G1
1388G6
1388G7
1389G6
1389G7
260G16
284G1
250G5
E26226
6331G3
6319G1
6331G7
6331G1
6331G2
6331G4
6331G5
6331G6
6331G8
6331G9
|
connector SB50 anderson
Abstract: 1309G4 anderson SB50
Text: SB 50 Anderson Power Products Connector ® The innovative SB® connectors provide cost-effective reliability, design flexibility and safety for your products' manufacture, installation and maintenance. APP's 2 pole connector is available with a 50 amp rating, 600 Volts continuous AC or DC
|
Original
|
PDF
|
DS-SB50
REV03
connector SB50 anderson
1309G4
anderson SB50
|
SBE160
Abstract: SB175 6170G1 ANDERSON POWER PRODUCTS SB175 PP180 anderson SB350 anderson 114204S1 anderson SB50 CMS223 SB50 anderson
Text: 8 6 7 4 5 ECRN 14255: update talbe 4/18/08 AMS 10/01/07 CMS ECRN 14192: CORRECT METRIC TABLE CONVERSIONS 8/2/02 11/21/02 CMS CMS ECRN 13507 ECRN 13533 BY: DATE CMS 2/23/01 DJD 3/1/01 CONTACT BUSHING 1 2 3 4 5 6 6 1 D CABLE CATALOG NUMBER CONNECTOR SERIES FOR USE
|
Original
|
PDF
|
PP75/SB50
PP120/SB120
PP180/SB175
SBE160/SBX175
SBE160
SB175
6170G1
ANDERSON POWER PRODUCTS SB175
PP180 anderson
SB350 anderson
114204S1
anderson SB50
CMS223
SB50 anderson
|
D1024
Abstract: connector SB50 anderson copper bus bar torque SB175 anderson 1 pp75 75BBS SB175 992G5 350BB
Text: Bus Bar Connector APP’s rugged Bus Bar Contacts are designed to attach directly to a copper bus, while offering a quick disconnect design that minimizes the expense of system assembly, replacement or repair. The contacts will handle 75 amps up to 350 amps and are
|
Original
|
PDF
|
mai2-3700
D1024
connector SB50 anderson
copper bus bar torque
SB175 anderson
1 pp75
75BBS
SB175
992G5
350BB
|
134G1
Abstract: SB175 SB350A connector SB350 anderson cad SB350 anderson SB50 114209S1 connector SB50 anderson
Text: 8 6 7 4 5 3 2 1 DATE BY: D CMS 7/10/08 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ANDERSON POWER PRODUCTS. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF ANDERSON POWER PRODUCTS IS PROHIBITED. A D ECRN 14286: 1.10 WAS 2.28
|
Original
|
PDF
|
134G1
134G2
134G3
SB175
SB350
CADFILES/01136
114209S1
134G1
SB175
SB350A
connector SB350 anderson cad
SB350
anderson SB50
114209S1
connector SB50 anderson
|
|
6331g8
Abstract: 1309G4 992 connector SB50 anderson 6331G5 6319G1 1388g6 6331G3 6331G1 6331G2 6331G4
Text: SB 50 Connector The innovative SB® connectors provide cost-effective reliability, design flexibility and safety for your products' manufacture, installation and maintenance. APP's 2 pole connector is available with a 50 amp rating, 600 Volts continuous AC or DC
|
Original
|
PDF
|
unitized2-3700
6331g8
1309G4 992
connector SB50 anderson
6331G5
6319G1
1388g6
6331G3
6331G1
6331G2
6331G4
|
SB175
Abstract: SB350 SB50 1S6498 SB120 PP180 PP180 anderson bbar
Text: Bus Bar Contact Assembly Instructions Powerpole Bus Bar SB Bus Bar Bus Bar Contact Assembly Instructions 1. Insert the contact into the D-shaped mounting hole in the bus bar. 2. Tighten the lock nut provided until the contact is locked securely in place see table . Do not grip nose of contact
|
Original
|
PDF
|
SB120
PP180*
SB175
SB350
1S6498
SB175
SB350
SB50
1S6498
SB120
PP180
PP180 anderson
bbar
|
Untitled
Abstract: No abstract text available
Text: SB Connectors The Anderson Pow er SB Connector Concept Anderson Power Products® SB® 2 pole connector is available in 50, 175, and 350 amps ratings for use to 600 Volts continuous AC or DC operation. Mechanical keys molded into connectors of the same color
|
OCR Scan
|
PDF
|
MA01564
|
SBX350
Abstract: SB50 anderson
Text: SB Connectors The Anderson Power SB® Connector Concept Anderson Power Products® SB® 2 pole connector is available in 50, 175, and 350 amps ratings for use to 600 Volts continuous AC or DC operation. Mechanical keys molded into connectors of the same color
|
OCR Scan
|
PDF
|
SBX175
SBX350
SBE160
SB50 anderson
|
Untitled
Abstract: No abstract text available
Text: SB Connectors The Anderson Power SB? Connector Concept Anderson Power Products® SB® 2 pole connector is available in 50, 175, and 350 amps ratings for use to 600 Volts continuous AC or DC operation. Mechanical keys molded into connectors of the same color
|
OCR Scan
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: SB Connectors Accessories Handles Polycarbonate handle relieves unnecessary strain on cables when disconnecting. Catalog Number For Use With 995G1 SB175 1 handle & hardware 4 screws 4 lockwashers 4 nuts Gray 995G3 SB175 1 handle & hardware 4 screws 4 lockwashers
|
OCR Scan
|
PDF
|
995G1
SB175
995G3
995G2
SB350
995G4
SB50-HDL
|
Untitled
Abstract: No abstract text available
Text: C rim p T o o lin g Crimp Tooling fo r Anderson Connectors The cross reference tables on the following pages list the recommended crimp tool to use for each of our connectors. They are organized by connector type and divided for Anderson's loose piece con
|
OCR Scan
|
PDF
|
1353G1
250G1/250G2
280G1/280G2
260G1/260G3
260G16
250G5
284G1
260G14
260G15
|
1300G3
Abstract: M542G-A-889G/W
Text: Part Listings HI 110G10 110G11 110G12 110G15 110G16 110G17 110G18 110G19 110G20 110G21 110G9 111038G2 111197 111197G1 113827P1 113828P1 113829P1 113830P1 113831P1 113834P1 113837P1 113838P1 113839P1 113839P2 113839P3 113839P4 113839P5 113845P1 115G1 115G2
|
OCR Scan
|
PDF
|
110G10
110G11
110G12
110G15
110G16
110G17
110G18
110G19
110G20
110G21
1300G3
M542G-A-889G/W
|
Untitled
Abstract: No abstract text available
Text: SBX Connectors Operating Characteristics Ampere/Temperature Curves See Figures 1 through 4 Ampere/Temperature curves help to evaluate and rate SBX connectors in terms of applied current load versus temperature rise. Each graph shows the curves resulting from loading the smallest and largest cables (AWG size) normally
|
OCR Scan
|
PDF
|
SB175
SB350
SBX175
SBX350
SBE160
SBE320
|
Untitled
Abstract: No abstract text available
Text: SBE Connectors Operating Characteristics Ampere/Temperature Curves See Figures 1 through 4 Ampere/Temperature curves help to evaluate and rate SBE® connectors in terms of applied current load versus temperature rise. Each graph shows the curves resulting from loading the smallest and largest cables (AWG size) normally
|
OCR Scan
|
PDF
|
SB175
SB350
SBX175
SBX350
SBE160
SBE32ot
|