Untitled
Abstract: No abstract text available
Text: AC Current transducer AT-B10 AC Current transducer AT-B10 Split-corefor transducer for the electronic measurement AC waveform Split-core transducer the electronic measurement of ACofwaveform withisolation galvanic isolation between primarycircuit circuit power
|
Original
|
AT-B10
0-10Vvoltage
|
PDF
|
AT-B420L
Abstract: at150b420l 100B420L
Text: AC Current transducer AT-B420L AC Current transducer AT-B420L Split-core transducer the electronic measurement of ACofwaveform Split-core for transducer for the electronic measurement AC waveform currents, withcurrents, galvanic between thethe primary power
|
Original
|
AT-B420L
4-20mA
24VDC
AT-B420L
at150b420l
100B420L
|
PDF
|
ATB10
Abstract: at20b10
Text: AC Current transducer AT-B10 AC Current transducer AT-B10 Split-corefor transducer for the electronic measurement AC waveform Split-core transducer the electronic measurement of ACofwaveform withisolation galvanic isolation between primarycircuit circuit power
|
Original
|
AT-B10
0-10Vvoltage
ATB10
at20b10
|
PDF
|
Untitled
Abstract: No abstract text available
Text: AC Current transducer AT-B420L AC Current transducer AT-B420L Split-core transducer the electronic measurement of ACofwaveform Split-core for transducer for the electronic measurement AC waveform currents, withcurrents, galvanic between thethe primary power
|
Original
|
AT-B420L
4-20mA
24VDC
|
PDF
|
Untitled
Abstract: No abstract text available
Text: AC Current transducer AT-B5 AC Current transducer AT-B5 Split-core transducer for the electronic measurement of ACofwaveform Split-core transducer for the electronic measurement AC waveform currents, with galvanic isolation between thethe primary circuit power
|
Original
|
|
PDF
|
LEM sensor CURRENT
Abstract: 40P-40P schematic diagram mini UPS SP600
Text: Current transducer FHS 40-P/SP600 I PM = 0 - 100 A Minisens FHS 40-P/SP600 transducer The Minisens transducer is an ultra flat SMD open loop integrated circuit current transducer based on the Hall effect principle. It is suitable for the electronic measurement of currents: DC, AC, pulsed, mixed. It has no insertion loss and
|
Original
|
40-P/SP600
40-P/SP600
J-STD-020
LEM sensor CURRENT
40P-40P
schematic diagram mini UPS
SP600
|
PDF
|
fhs 40-p
Abstract: sp600 electronic circuit diagram UPS fhs 40 p fhs 40 p sp600 lem smd
Text: Current transducer FHS 40-P/SP600 I PM = 0 - 100 A Minisens FHS 40-P/SP600 transducer The Minisens transducer is an ultra flat SMD open loop integrated circuit current transducer based on the Hall effect principle. It is suitable for the electronic measurement of currents: DC, AC, pulsed, mixed. It has no insertion loss and
|
Original
|
40-P/SP600
40-P/SP600
fhs 40-p
sp600
electronic circuit diagram UPS
fhs 40 p
fhs 40 p sp600
lem smd
|
PDF
|
CTSR 0.3-P
Abstract: No abstract text available
Text: Current Transducer CTSR 0.3-P/SP1 IPRN = 300 mA For the electronic measurement of current: DC, AC, pulsed., with galvanic isolation between the primary and the secondary circuit. Applications Features Closed loop compensated current transducer Residual current measurement
|
Original
|
94-V0
3November2011/version
CTSR 0.3-P
|
PDF
|
B420
Abstract: dk300b420
Text: DC Current transducer DK-B020/420 A split core transducer for the electronic measurement DC current, with galvanic isolation between the primary High power and the secondary circuits (Electronic circuit) with current output. Electrical data Primary Nominal Current
|
Original
|
DK-B020/420
4-20mA
12-22AWG
B420
dk300b420
|
PDF
|
Untitled
Abstract: No abstract text available
Text: DC current transducer DK-B020 Split core transducer for the electronic measurement of DC current, with galvanic isolation between the primary circuit high power and the secondary circuit (electronic). 0-20 mA output current proportional to measured current.
|
Original
|
DK-B020
|
PDF
|
Untitled
Abstract: No abstract text available
Text: DC current transducer DK-B420 U Split core transducer for the electronic measurement of DC current, with galvanic isolation between the primary circuit and the secondary circuit. 4-20 mA unipolar output current proportional to measured current. Features Electrical data
|
Original
|
DK-B420
24May2012/version
|
PDF
|
Untitled
Abstract: No abstract text available
Text: DC current transducer DK-C5 U Solid core transducer for the electronic unidirectional measurement of DC current, with galvanic isolation between the primary circuit high power and the secondary circuit (electronic). 0-5 V DC output current proportional to measured current.
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: DC current transducer DK-B420 Split core transducer for the electronic measurement of DC current, with galvanic isolation between the primary circuit and the secondary circuit. 4-20 mA output current proportional to measured current. IPN = 50 . 200 A Electrical data
|
Original
|
DK-B420
22May2012/version
|
PDF
|
CTSR
Abstract: No abstract text available
Text: Current Transducer CTSR 0.6-TP/SP2 IPRN = 600 mA For the electronic measurement of current: DC, AC, pulsed., with galvanic isolation between the primary and the secondary circuit. Applications Features Closed loop compensated current transducer Voltage output
|
Original
|
94-V0
4November2011/version
CTSR
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: DC current transducer DK-C420 U Solid core transducer for the electronic unidirectional measurement of DC current, with galvanic isolation between the primary circuit high power and the secondary circuit (electronic). 4-20 mA output current proportional to measured current.
|
Original
|
DK-C420
|
PDF
|
B420
Abstract: No abstract text available
Text: DC Current transducer DK-B020/420 A split core transducer for the electronic measurement DC current, with galvanic isolation between the primary High power and the secondary circuits (Electronic circuit) with current output. Electrical data IPN = 50 . 400A
|
Original
|
DK-B020/420
12-22AWG
B420
|
PDF
|
Untitled
Abstract: No abstract text available
Text: DC current transducer DK-C420 B Solid core transducer for the electronic measurement of bidirectional DC current, with galvanic isolation between the primary high power and the secondary circuit (electronic circuit). 4-20 mA output current proportional to measured current.
|
Original
|
DK-C420
|
PDF
|
90980
Abstract: No abstract text available
Text: DC current transducer DK-C10 U Solid core transducer for the electronic unidirectional measurement of DC current, with galvanic isolation between the primary circuit high power and the secondary circuit (electronic). 0-10 V DC output current proportional to measured current.
|
Original
|
DK-C10
90980
|
PDF
|
Untitled
Abstract: No abstract text available
Text: DC Current transducer DK-B5/10 A split core transducer for the electronic measurement DC current, with galvanic isolation between the primary High power and the secondary circuits (Electronic circuit) with voltage output. Electrical data Primary Nominal Current
|
Original
|
DK-B5/10
12-22AWG
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Current Transducer CTSR 0.6-TP/SP2 IPRN = 600 mA For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary circuit and the secondary circuit. Features Applications ●● Closed loop compensated current transducer
|
Original
|
28January2014/version
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Current Transducer CTSR 0.3-TP/SP4 IPRN = 300 mA For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary circuit and the secondary circuit. Features Applications ●● Closed loop compensated current transducer
|
Original
|
28January2014/version
|
PDF
|
Untitled
Abstract: No abstract text available
Text: DC current transducer DK-B10 Split core transducer for the electronic measurement of DC current, with galvanic isolation between the primary circuit and the secondary circuit. 0-10 V DC output voltage proportional to measured current. Features Electrical data
|
Original
|
DK-B10
22May2012/version
|
PDF
|
Untitled
Abstract: No abstract text available
Text: DC Current transducer DK-B3/5/10 A split core transducer for the electronic measurement DC current, with galvanic isolation between the primary High power and the secondary circuits (Electronic circuit) with voltage output. Electrical data Primary Nominal Current
|
Original
|
DK-B3/5/10
12-22AWG
|
PDF
|
Untitled
Abstract: No abstract text available
Text: DC current transducer DK-B420 B IPN = 50 . 200 A Split core transducer for the electronic measurement of bipolar DC current, with galvanic isolation between the primary and the secondary circuit. 4-20 mA output current proportional to measured current. Electrical data
|
Original
|
DK-B420
12-22AWG
22May2012/version
|
PDF
|