    Part ECAD Model Manufacturer Description Download Buy
    DRV3946QPWPRQ1 Texas Instruments Automotive 12-V contactor driver with current sensing and regulation 28-HTSSOP -40 to 125 Visit Texas Instruments

    D50 CONTACTORS Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    dr5te4u

    Abstract: DR5TE4U contactor coil rectifier LC1-F115 LC1-D40 LX1D6M5 LC1 F150 LC1-D115 LC1 F115 LC1 Schneider lx1d6f7
    Text: Repair Parts D- and F-Line AC Coils www.SquareD.com FOR CURRENT INFORMATION For LC1 D40, D50, D65, D80 Rated voltage nominal voltage V 24 32 42 48 110 120 127 208 220 230 240 256 277 380 400 415 440 480 500 575 600 660 Specification Average consumption - inrush inductance .75


    Original
    PDF 8502CT9901R2/01 dr5te4u DR5TE4U contactor coil rectifier LC1-F115 LC1-D40 LX1D6M5 LC1 F150 LC1-D115 LC1 F115 LC1 Schneider lx1d6f7

    lc1d12008

    Abstract: LC1D40008 lc1-d25008 LC1D12004 LC1-D1810 lp1d1210 telemecanique LC1-d18 LC2D0901 LA1-DN22 telemecanique contactor LC1D80
    Text: Contactors d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. Dimensions, mounting : pages 1/44 to 1/48 References Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 θ ≤ 55 °C 1 Rated operational


    Original
    PDF LC1-D0900ii LC1-D0910ii LC1-D0901ii LC1-D1200ii LC1-D1210ii LC1-D1201ii LC1-D1800ii LC1-D1810ii LC1-D1801ii LC1-D2500ii lc1d12008 LC1D40008 lc1-d25008 LC1D12004 LC1-D1810 lp1d1210 telemecanique LC1-d18 LC2D0901 LA1-DN22 telemecanique contactor LC1D80

    LC1-D25 wiring

    Abstract: LRD32 LA7D3064 LRD-4365 LC1-D25 LRD33 LRD-05 LAD-7305 LRD-04 LA7-D1064
    Text: Overload Relays D-Line Bimetallic www.SquareD.com FOR CURRENT INFORMATION Ambient Bi-metallic overload relays LRD overload relays are designed for direct mounting to D-line contactors. To mount these overloads separately, select separate mount kits from the


    Original
    PDF D09--D32 LRD01 LRD02 LRD03 LRD04 LRD05 LC1-D25 wiring LRD32 LA7D3064 LRD-4365 LC1-D25 LRD33 LRD-05 LAD-7305 LRD-04 LA7-D1064

    transformer 18-0-18

    Abstract: 9070T1500D1 9070T500D50 9070T1000D1 9070T750D1 9070T5000D1 9070T3000D1 9070T100D50 transformer 3000va LR37055
    Text: Industrial Control Transformers Class 9070 Catalog August 05 CONTENTS Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3


    Original
    PDF 1-888-Square 9070CT9901R8/05 9070CT9901 transformer 18-0-18 9070T1500D1 9070T500D50 9070T1000D1 9070T750D1 9070T5000D1 9070T3000D1 9070T100D50 transformer 3000va LR37055

    LC1-D09 installation manual

    Abstract: 3TB44 3UA50 3TF42 3UA52 3TF52 3TB50 LR2-D13 3TB54 overload contactor LR2-D13
    Text: Motor control device 1-1 Termal overload relay JRS3 3RU series thermal relay Applications JRS3(3RU)series thermal relays are suitable for using in the power system with AC 50/60Hz, rated operaton voltage up to 690-1000V, rated operation current from 0.1A to 100A.They are used to protect AC 3 phase


    Original
    PDF 50/60Hz, 90-1000V, IEC60947-4-1 JRS3-12 LC1-D09 installation manual 3TB44 3UA50 3TF42 3UA52 3TF52 3TB50 LR2-D13 3TB54 overload contactor LR2-D13

    LC1-D09

    Abstract: LC1-D18 LC1-D32 LA6DK10 LC1-D80 dimensions LC1-D2510 LC1-D80 LC1-D40 LC1-D40 DIMENSIONS LC1-D 188
    Text: Contactors and protection relays Contactors, types LC1-D Selection guide : pages 1/12 to 1/43 Characteristics : pages 2/56 to 2/69 References : pages 2/70 to 2/77 Schemes : pages 2/92 and 2/93 Dimensions c 12,5 LA8 c1(LA1) 45 12,5 (LA8) 56 107(3)(DF,DT)


    Original
    PDF D2510 D2501, D2504 LA1-DN10 LC1-D80, LA6-DK10) D2500 LC1-D40, LC1-D2510, LC1-D09 LC1-D18 LC1-D32 LA6DK10 LC1-D80 dimensions LC1-D2510 LC1-D80 LC1-D40 LC1-D40 DIMENSIONS LC1-D 188

    LC1 D32 wiring diagram

    Abstract: schneider overload relay lrd 25 LC1 contactor LA7 D09 54 overload schneider thermal overload relay lrd 32 LC1 d32 contactor diagram schneider electric LC1 D25 LA7 D09 LRD 14 LC1 d150 wiring diagram
    Text: Issued November 2009 DATA SHEET LR-D OVERLOAD RELAYS Based on Schneider MKTED205103EN Catalogue 12493 General 6 12493 Protection components 6 Motor protection Operating conditions There are many possible causes of electric motor failure. One of the most common,


    Original
    PDF MKTED205103EN LC1 D32 wiring diagram schneider overload relay lrd 25 LC1 contactor LA7 D09 54 overload schneider thermal overload relay lrd 32 LC1 d32 contactor diagram schneider electric LC1 D25 LA7 D09 LRD 14 LC1 d150 wiring diagram

    schneider LRD 08

    Abstract: LRD schneider relay LC1-D65 LC1-D50 Schneider Electric LRD 06 LR9-D5369 LC1-D09 schneider overload relay schneider LC1-D09 LRD-21
    Text: 24516 Page 108 Friday, October 26, 2001 9:32 AM Description, characteristics TeSys protection components 3-pole thermal overload relays, model d Description Model d 3-pole thermal overload relays are designed to protect a.c. circuits and motors against overloads, phase failure,


    Original
    PDF LRD-01. LRD-3322. LR9-D67 LR9-D69 schneider LRD 08 LRD schneider relay LC1-D65 LC1-D50 Schneider Electric LRD 06 LR9-D5369 LC1-D09 schneider overload relay schneider LC1-D09 LRD-21

    schneider lc1d

    Abstract: schneider LC1-D LC1-D80 008 lc1-d 173 schneider LC1-D80 Schneider Electric LC1d lc1d contactor coils LP1-D65 tesys d contactors CONTACTOR LC1-D115
    Text: References TeSys contactors a.c. coils for 3-pole contactors LC1-D Control circuit voltage Uc V Average resistance at 20 °C ± 10 % Ω Inductance of closed circuit H Reference 1 Weight kg For 3-pole " contactors LC1-D09.D38 and LC1-DT20…DT60 Specifications


    Original
    PDF LC1-D09. LC1-DT20. LC1-D80 LP1-D80 schneider lc1d schneider LC1-D LC1-D80 008 lc1-d 173 schneider LC1-D80 Schneider Electric LC1d lc1d contactor coils LP1-D65 tesys d contactors CONTACTOR LC1-D115

    LC1-D150

    Abstract: bs 5424 schneider LC1-D09 schneider LC1-D09 LC1-D40 LC1 Schneider VDE 0660 BS 5424 lad6k10 LA4 dfb IEC 60947-5-1
    Text: 24505 Page 62 Thursday, October 25, 2001 5:44 PM Characteristics TeSys contactors Model d Farnell Codes ; 4231855 - 4232148 Type of contactor LC1LC1D09…D18 D25…D38 DT20 & DT25 DT32…DT6 LC1D40 1000 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage Ui


    Original
    PDF LC1LC1D09. LC1D40 LC1D50. LC1-D115 LC1-D150 LC1-D09. LC1-D80 LC1-D40. LC1-D150 bs 5424 schneider LC1-D09 schneider LC1-D09 LC1-D40 LC1 Schneider VDE 0660 BS 5424 lad6k10 LA4 dfb IEC 60947-5-1

    LC1-D123

    Abstract: LC1-D093 LC1-D323 LC1-D183 LA6-DK20 LC1-D253 LAD6K10 LC1-D150 LAD-4RC LA6DK10
    Text: Characteristics TeSys contactors 5 Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32 & DT40 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage Ui 2 Rated impulse withstand voltage (Uimp) Conforming to IEC EN 947-4-1,


    Original
    PDF LC1LC1LC1D09. LC1D50. LC1-D115 LC1-D150 LC1-D09. LC1-D80 LC1-D40. LC1-D123 LC1-D093 LC1-D323 LC1-D183 LA6-DK20 LC1-D253 LAD6K10 LC1-D150 LAD-4RC LA6DK10

    LC1-D09

    Abstract: LC1-D150 lad6k10 schneider LC1-D09 bs 5424 schneider schneider LC1-D LC1 Schneider LC1-D115 LC1-D09 diagram LA6DK10
    Text: Characteristics TeSys contactors Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32…DT60 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage Ui Rated impulse withstand voltage (Uimp) 2 Conforming to EN 60947-4-1,


    Original
    PDF LC1LC1LC1D09. LC1D50. LC1-D115 LC1-D150 LC1-D09. LC1-D80 LC1-D40. LC1-D09 LC1-D150 lad6k10 schneider LC1-D09 bs 5424 schneider schneider LC1-D LC1 Schneider LC1-D115 LC1-D09 diagram LA6DK10

    LC1-D09

    Abstract: dimension LC1-D09 LC1-D25 LC1-D09 installation manual LC1-D25 wiring LC1-D2500 LP1-D09 380V 415v motor LC1 D25008 LP1-D25
    Text: Motor Control Device 1-1 Magnetic latching contactors GCR1-F series magnetic latching contactors Magnetic latching contactors of both block and bar mounted types are fitted with a special electromagnet which enables them to remain in the "On" position when the coil is no longer energised.


    Original
    PDF GLE1-D09 GLE1-D018 GLE1-D25 GLE1-D32 GLE1-D40 GLE1-D95 LC1-D09 dimension LC1-D09 LC1-D25 LC1-D09 installation manual LC1-D25 wiring LC1-D2500 LP1-D09 380V 415v motor LC1 D25008 LP1-D25

    LC1-D50A

    Abstract: LC1D40A schneider LC1-D09 LC1-DWK12 LC1D65A LC1-D09 LAD4TBDL LC1-D18 LC1-D09 installation manual LC1-D12
    Text: Motor control 1 TeSys range provide you more simplicity, compactness, openness and flexibility . so many evolutions and new items to aid your productivity. 2 Accurate and reliable control of motors 3 4 5 6 7 Increase your productivity, adopt our solutions which help to simplify


    Original
    PDF LC1-F630, F6304 LC1-F500 F5004 LC1-F400 F4004 LC1-D50A LC1D40A schneider LC1-D09 LC1-DWK12 LC1D65A LC1-D09 LAD4TBDL LC1-D18 LC1-D09 installation manual LC1-D12

    LC1 D38

    Abstract: lc1 f265 LC1 F400 LC1-k16 LP1 K12 contactor LC1-D25 Lc1 f630 LP1 K09 LC1-D09 LC1-D18
    Text: Selection 5 TeSys contactors 5 For utilisation category AC-3 Operational current and power conforming to IEC θ y 60 °C 1 Contactor size Maximum operational current in AC-3 Rated operational power P (standard motor power ratings) 2 3 y 440 V A LC1/ LP1


    Original
    PDF

    Honeywell Yamatake Sa 90

    Abstract: Yamatake honeywell lg tv repair manual yamatake limit switch catalogue fuses manual Honeywell 38240 diagram LG TV circuits 5866A2 NFPA79 LG contactors
    Text: FF-SRST Emergency Stop Module with Timer FEATURES • Complies with the Machinery Directive for 98/37/EC, IEC 204, EN 60204, DIN VDE 0113 and UL 508 • Dual channel input • Safety outputs: two direct NO contacts, one direct NC contact, two NO delayed contacts and one NC delayed contact


    Original
    PDF 98/37/EC, 107058-13-EN Honeywell Yamatake Sa 90 Yamatake honeywell lg tv repair manual yamatake limit switch catalogue fuses manual Honeywell 38240 diagram LG TV circuits 5866A2 NFPA79 LG contactors

    FX3U-48M

    Abstract: FX3U-32M a6tbxy36 FX3U-64M FX2N 64mr manual FX3U-80M pid temprature controller FX2N-16EX JY997D16901 FX3U-128M
    Text: MITSUBISHI ELECTRIC MELSEC FX Series Programmable Logic Controllers User's Manual Hardware FX3U Base Units and Extension Blocks Art. no: 168590 01062007 Version E MITSUBISHI ELECTRIC INDUSTRIAL AUTOMATION Safety Precautions (Read these precautions before use.)


    Original
    PDF D-40880 168590-E FX3U-48M FX3U-32M a6tbxy36 FX3U-64M FX2N 64mr manual FX3U-80M pid temprature controller FX2N-16EX JY997D16901 FX3U-128M

    kss 152a laser

    Abstract: ILP toroidal transformer Diode BFK 66A BA911 KBP 2060 LRD20 wiring diagram STAR DELTA motor sequential starter fire alarm using IC 555 and thermistor 6Kv marking 5d capacitor b1250 15000
    Text: Index Motor control and protection Motor protection circuit breakers 1 Contactors 2 Motor protection relays 3 Electromechanical starters 4 Soft starters 5 AC motor drives Control and signalling 6 RUN MON STOP ENT Pushbuttons and selector switches 7 Signal towers and beacons


    Original
    PDF EXP10 RS232/TTL kss 152a laser ILP toroidal transformer Diode BFK 66A BA911 KBP 2060 LRD20 wiring diagram STAR DELTA motor sequential starter fire alarm using IC 555 and thermistor 6Kv marking 5d capacitor b1250 15000

    schneider LC1-D09 wiring diagram

    Abstract: LC1-D09 installation manual ATV312HU22N4 ATV312HU40N4 ATV312H075M2 312HU15N4 312HU55N4 312HU75N4 ATV312HU15N4 wiring diagram altivar 31
    Text: Variable speed drives Altivar 312 Catalogue April 2009 General contents Variable speed drives Altivar 312 b Brochure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2 b Catalogue. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11


    Original
    PDF DIA2ED2090404EN schneider LC1-D09 wiring diagram LC1-D09 installation manual ATV312HU22N4 ATV312HU40N4 ATV312H075M2 312HU15N4 312HU55N4 312HU75N4 ATV312HU15N4 wiring diagram altivar 31

    schneider LC1-D09 wiring diagram

    Abstract: LC1-D38 LC1-D18 LT6P0M005FM LC2K06 LC1-D09 installation manual LC1K0910BD 8502CT9901 LC1K0910P7 LC1-D12
    Text: Motor control Accurate and reliable control of motors Te Sys range provide you more simplicity, compactness, openness and flexibility . so man y evolutions and new items to aid your productivity. Search By Part Number TeSys For a new start! A range of simple,


    Original
    PDF 9422CLA50 9422CLA51 9422CLA10 9422CLA11 9422CSF30 9422CSF50 9422CSF70 9422CSF10 9422CSF304 9422CSF504 schneider LC1-D09 wiring diagram LC1-D38 LC1-D18 LT6P0M005FM LC2K06 LC1-D09 installation manual LC1K0910BD 8502CT9901 LC1K0910P7 LC1-D12

    Mitsubishi th-n20kp

    Abstract: AD16-22DS Kyoritsu 3301 kyoritsu model 1008 terasaki xh100ns KSD 166 16a 250v ksd 302 250v, 10a carlo gavazzi VDE 0660 ksd 250v 10a EEL 22w transformer
    Text: CONTENT KIN AUTOMATI ON SDN. BHD. ANDELI Bus bar Support Power Supply MCB Bar Contactor / Thermal Overload Relay / Auxiliary Contact Terminal Block Din Rail Terminal Block C/W Cover Terminal Block Float Switch Foot Switch Warning Light / Tower Light Hour Run Meter / Time Switch / Weather Proof Isolating Switch


    Original
    PDF 100HP) 125HP) 112KW 150HP) 135KW 180HP) 150KW 200HP) 164KW 220HP) Mitsubishi th-n20kp AD16-22DS Kyoritsu 3301 kyoritsu model 1008 terasaki xh100ns KSD 166 16a 250v ksd 302 250v, 10a carlo gavazzi VDE 0660 ksd 250v 10a EEL 22w transformer

    s41 hall effect sensor s41

    Abstract: sensor sr21 datalogic DATA SENSOR TLU-015 D50NK LASER ILLUMINATOR hall effect sensor s41
    Text: SENSORS, SAFETY & MEASUREMENT Short Form Catalogue 2014 I 2015 www.acdc.co.za PRODUCT PICTURE OUTPUT SPECIFICATIONS PAGE • 3 Wire VDC PNP NO-NC, NPN NO-NC 1 • 2 Wire VDC NO-NC 1 • 2 Wire VAC NO-NC 1 • Terminal Block VDC PNP NO-NC, NPN NO-NC 2 • 2 Wire VAC/VDC NO, NC


    Original
    PDF 4-20mA s41 hall effect sensor s41 sensor sr21 datalogic DATA SENSOR TLU-015 D50NK LASER ILLUMINATOR hall effect sensor s41

    dinverter 768r

    Abstract: G7D-412S Ericsson Installation guide for RBS 6201 OMRON G7d TH3 thermistor 6201 RBS ericsson user manual TMS77C82NL reed relay rs 349-355 i ball 450 watt smps repairing RBS -ericsson 6601
    Text: Discontinued and Superseded Stock Number History. This document contains Discontinued and Superseded Stock Number History. The information is listed in the following format: Stock Number: The original RS Stock Number of the item. Brief Description: The Invoice Description of the item.


    Original
    PDF HEF4527BT HEF4531BT HEF4534BP HEF4534BT MSP-STK430X320 AD9054/PCB AD9054BST-135 IPS521G IPS521S IRL2203S dinverter 768r G7D-412S Ericsson Installation guide for RBS 6201 OMRON G7d TH3 thermistor 6201 RBS ericsson user manual TMS77C82NL reed relay rs 349-355 i ball 450 watt smps repairing RBS -ericsson 6601

    LC1-D0910

    Abstract: LC1-D150 LC1-D6511 LC1-D5011 LC1-D18 LC1-D12 NFC 63-110 LC1D0910 LC1-D09 LC1D1201
    Text: Contactors and protection relays Selection guide pages 1 '12 tu 1/43 References . uages 2/70 to 2''101 Dimensions pages 2/88 to 2*91 2/102 and 2/103 Schemes pages 2/92. 2'93 and 2 /’ 03 Type Contactors, types LC1-D and LP1-D Control circuit: a.c. or d.c.


    OCR Scan
    PDF LC1-D09 LC1-D12 LC1-D18 LC1-D25 LP1-D09 LP1-D12 LP1-D18 LP1-D25 LC1-D40 LC1-D0910 LC1-D150 LC1-D6511 LC1-D5011 NFC 63-110 LC1D0910 LC1D1201