Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    DESIGO Search Results

    DESIGO Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    CA2A3810

    Abstract: CA2N3804 RXT10 CM110669
    Text: 3 s 840 Desigo RXC Room controller, basic module RXC30.1/ RXC30.5 for chilled ceiling/radiator control and for control of lighting, with LONMARK -compatible bus communications The RXC30 controller is used for the control of temperature and lighting in


    Original
    PDF RXC30 STP73 RXC30 CA2N3840en 3840M02 3840M01 CA2A3810 CA2N3804 RXT10 CM110669

    CA110300

    Abstract: No abstract text available
    Text: s 3 856 Desigo RXC Room controller RXC39.5 Communicating room controller for fan-coil applications The RXC39.5 room controller is used for temperature control in individual rooms. • For fan-coil systems with ECM fan · PI / PID control depending on application


    Original
    PDF RXC39 RXT10 CM2N3856en 3876M01 3876M02 CA110300

    Siemens Ni1000 temperature sensor

    Abstract: n531 QAC22 N9292 LG-Ni1000 QFM3100 triac BT 317 DATASHEET
    Text: System Catalog 2014 The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract.


    Original
    PDF

    QXA2602

    Abstract: CM1Y9777 TRIAC ACS 12 QXA2604 cm1y9775 X2M ST
    Text: s Room thermostats with KNX communications 3 191 RDG100KN RDG160KN – For fan coil unit applications – For universal applications – For use with compressor in DX type equipment • • • • • • • • • • • • • • • • KNX bus communication S-mode and LTE mode


    Original
    PDF RDG100KN RDG160KN RDG100KN, RDG160KN CE1N3191en QXA2602 CM1Y9777 TRIAC ACS 12 QXA2604 cm1y9775 X2M ST

    polygyr

    Abstract: QAA24 polygyr RWF 32 polygyr rwf siemens RWF qaa25 RKN8 siemens air temperature sensors QAA24 rwi65.01 RWF 32
    Text: 1 . . . . . . . . . 1721P020 1721P010 721 QAA24 QAA25QAA27 Room Temperature Sensors QAA24.27 with and without setpoint adjuster Use In heating, ventilating and air conditioning plants, especially where a high level of comfort is required. Major field of application:


    Original
    PDF 1721P020 1721P010 QAA24 QAA25. QAA27 QAA24. QAA25 QAA26 polygyr QAA24 polygyr RWF 32 polygyr rwf siemens RWF qaa25 RKN8 siemens air temperature sensors QAA24 rwi65.01 RWF 32

    VOC sensor

    Abstract: polygyr SIEMENS gas QPA63.1 ARG64 QPA63.1 co2 sensor QPA63 Siemens duct temperature sensor RWI65 Siemens duct temperature controller
    Text: 1 QPA63.1 . . . . . . . . 1958P03 1958P02 1958P01 958 QPA63.2 QPA63.1/AUS QPA63. CO2 /VOC Sensors Sensors designed for acquiring indoor air quality in rooms or air ducts. Microprocessor-based units consisting of a selective photo-acoustic CO2 sensor and a VOC1 sensor with a heated stannic dioxide semiconductor.


    Original
    PDF QPA63 1958P03 1958P02 1958P01 QPA63. CM1N1958E VOC sensor polygyr SIEMENS gas QPA63.1 ARG64 QPA63.1 co2 sensor Siemens duct temperature sensor RWI65 Siemens duct temperature controller

    Siemens Ni1000 temperature sensor

    Abstract: landis staefa QAM22 staefa t1 sensor ni1000 Ni1000 temperature sensor Siemens QAM22 qam22 AQA61 EN50022-35 siemens qaa
    Text: 5 Signal transducer T1 for Ni1000 temperature sensor 142 AQA61.20 Signal transducer allowing the use of Ni1000 sensors for controllers with a T1 sensor input.  Converts an Ni1000 sensor signal into a T1-type output signal  Transducer supply from connected controller


    Original
    PDF Ni1000 AQA61 QAM22 AQA61. IEC529 Siemens Ni1000 temperature sensor landis staefa QAM22 staefa t1 sensor Ni1000 temperature sensor Siemens QAM22 EN50022-35 siemens qaa

    CA2N3804

    Abstract: No abstract text available
    Text: s 3 878 RXL RXL24.1 Room controller Communicating controller for chilled ceiling and radiator applications CC-02 The RXL24.1 room controller is used for temperature control in individual rooms. • For chilled ceiling and radiator systems  PI control  Proprietary bus communication


    Original
    PDF RXL24 CC-02 CM2N3878en 3873M14 3877M15 CA2N3804

    TNY 176 PN EQUIVALENT

    Abstract: AY-5-8100 TFK 7 segment displays AY5-8100 7-segment display tfk FTC S211 TNY 177 PN EQUIVALENT saa1130 TNY 176 PN AY-3-8500
    Text: 1977 DATA CATALOG f m ELECTRONICS G E N E R A L I N S T R U M E N T C O R P O R A T I O N » M IC R O E L E C T R O N I C S r I' i i INDEX/GENERAL INFORMATION. CALCULATORS. CLOCKS.


    OCR Scan