home ups wiring diagram
Abstract: LAYOUT PCB UPS 12V wiring diagram of ups 9 pin to 15 PIN wiring DIAGRAM 12v 60A diagram double coil latching relays pcb Magnetic latching relay
Text: Magnetic Latching Relay INDUSTRIAL RELAYS RJC1B SERIES DIMENSIONS Unit: mm FEATURES • • • • • High contact load. Low consumption. Pulse driven operation. Strong resistance ability to shock and vibration. High reliability. Long Service life. Optionally single coil, as well as double coil.
|
Original
|
|
PDF
|
tyco 3sbm relay
Abstract: 3SBM6131N2R 3sbm 3SBM6131N2 37Ohms Mil-R-39016
Text: tqca Code Location Guide €11 Electronics 150 Grid-space Relays Magnetic- latching Type 3SBM 4PDT Other Specifications Contact Arrangement: Operate Time: Features 4-pole double-throw (4C) 4 ms max. • Low profile.only 0.32 inch high • Internal diode for coil transient
|
OCR Scan
|
MIL-R-39016/31
150-grid
tyco 3sbm relay
3SBM6131N2R
3sbm
3SBM6131N2
37Ohms
Mil-R-39016
|
PDF
|
double coil latching relays
Abstract: double coil latching relays pcb V23201
Text: PCB Relays Single Relays Catalog 1308019-2 Revision 10-06 Power Relay PK2 – Monostable and Latching Description Features - 60% volume reduced Power K at increased performance - PCB area requirements minimized by 50% to only 293 mm 2 - Size optimized to L x W x H in mm
|
Original
|
V23201-*
19/Reset
double coil latching relays
double coil latching relays pcb
V23201
|
PDF
|
Suitable for 4 and 5 pin standard relays
Abstract: V23201 V23201-C1001-A502 hpa 0806
Text: PCB Relays Single Relays Catalog 1308019-2 Revision 08-06 Power Relay PK2 – Monostable and Latching Description Features - 60% volume reduced Power K at increased performance - PCB area requirements minimized by 50% to only 293 mm 2 - Size optimized to L x W x H in mm
|
Original
|
V23201-*
19/Reset
Suitable for 4 and 5 pin standard relays
V23201
V23201-C1001-A502
hpa 0806
|
PDF
|
G6CU-2117P-VD
Abstract: G6CU-2117P 1117c g6cu-2114p G6CK-2114C G6C-2117P-US 5VDC g6ck2114p Relays OMRON g6c1114pus
Text: 5/10/07 15:39 Page 106 Text Power Relay – G6C PCB Text Power Relay – G5CA PCB Precautions • Precautions for Correct Use Installation Make sure that sufficient space is provided between relays when installing two or more relays side by side to facilitate heat
|
Original
|
P6C-06P
P6C-08P
K018-E2-05A-X
G6CU-2117P-VD
G6CU-2117P
1117c
g6cu-2114p
G6CK-2114C
G6C-2117P-US 5VDC
g6ck2114p
Relays OMRON
g6c1114pus
|
PDF
|
G2R-24
Abstract: G2R-2A4 CSA22 CTI250 E41643 EN60335-1 EN61810-1 G2R-14 LR31928 latching relay G2R
Text: 5/10/07 15:39 Page 116 Text Power Relay – G2R PCB Text Power Relay – G2R PCB A Power Relay for a Variety of Purposes with Various Models Model Number Legend G2R • Conforms to EN 61810-1, UL508, CSA22.2, SEV, SEMKO. ■ Meets EN60335-1 requirements for household
|
Original
|
UL508,
CSA22
EN60335-1
K013-E2-12A-X
G2R-24
G2R-2A4
CTI250
E41643
EN61810-1
G2R-14
LR31928
latching relay G2R
|
PDF
|
Untitled
Abstract: No abstract text available
Text: PCB Power Relay G5RL -U/-K 16 A High Switching Current, Generalpurpose Latching Relay • Availalbe with Single coil or Dual coil latching versions. • Creepage distance 8 mm between coil and contacts. • 10 kV Impulse withstand voltage. • Ambient Operating Temperature, 85°C
|
Original
|
K265-E-02
|
PDF
|
Untitled
Abstract: No abstract text available
Text: G5RL-U/-K PCB Power Relay 16 A High Switching Current, General-purpose Latching Relay • Creepage distance 8 mm between coil and contacts. • 10 kV Impulse withstand voltage. • Ambient Operating Temperature 85°C • Suitable for TV-8 rating. SPST-NO (1a
|
Original
|
K265-E1-03
|
PDF
|
Untitled
Abstract: No abstract text available
Text: G5RL-U/-K PCB Power Relay 16 A High Switching Current, General-purpose Latching Relay • Creepage distance 8 mm between coil and contacts. • 10 kV Impulse withstand voltage. • Ambient Operating Temperature 85°C • Suitable for TV-8 rating. SPST-NO (1a
|
Original
|
K265-E1-04
|
PDF
|
Omron
Abstract: G8QE-1A 12 VDC G2R1
Text: G2R PCB Power Relay The Best Seller G2R • 1General purpose power Relays of single-pole10 A and double-pole 5 A. • Safety-oriented design with dielectric strength of 5,000 V between coil and contacts, and surge resistance of 10,000 V. • AC and DC types are both available for operational coils.
|
Original
|
single-pole10
K013-E1-13
Omron
G8QE-1A 12 VDC
G2R1
|
PDF
|
AMP170330-1
Abstract: G2R-1 OMRON G2R-24 G2R-24 G2R-14 R50030327 G2R-2 AMP172074-6 G2R-1-E200 g2r-14-u
Text: G2R PCB Power Relay The Best Seller G2R • 1General purpose power Relays of single-pole10 A and double-pole 5 A. • Safety-oriented design with dielectric strength of 5,000 V between coil and contacts, and surge resistance of 10,000 V. • AC and DC types are both available for operational coils.
|
Original
|
single-pole10
K013-E1-13
AMP170330-1
G2R-1
OMRON G2R-24
G2R-24
G2R-14
R50030327
G2R-2
AMP172074-6
G2R-1-E200
g2r-14-u
|
PDF
|
relay 48, 1c
Abstract: G8QE-1A 12 VDC
Text: G2R PCB Power Relay The Best Seller G2R • 1General purpose power Relays of single-pole10 A and double-pole 5 A. • Safety-oriented design with dielectric strength of 5,000 V between coil and contacts, and surge resistance of 10,000 V. • AC and DC types are both available for operational coils.
|
Original
|
single-pole10
K013-E1-13
relay 48, 1c
G8QE-1A 12 VDC
|
PDF
|
G6AK-234P-ST-US
Abstract: G6AK-474P-ST40-US G6AU-274P-ST-US relay 4PDT dpdt latching relay omron GG6AK-274P-ST omron g6a-434p
Text: 5/10/07 15:39 Page 248 PCB Text Signal Relay – G5V-2 Text Signal Relay – G6A PCB Dimensions Fully sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment Note: 1. All units are in millimetres unless otherwise indicated. 2. Orientation marks are indicated as follows:
|
Original
|
K020-E2-08A-X
G6AK-234P-ST-US
G6AK-474P-ST40-US
G6AU-274P-ST-US
relay 4PDT
dpdt latching relay omron
GG6AK-274P-ST
omron g6a-434p
|
PDF
|
v23086-r2802-a803
Abstract: v23086-c2001-a403 v23086-c2001 v23086 V23086-C2
Text: Automotive Relays PCB Double Relays Double Micro Relay K THT – THR Q Q Q Q Q Q Q Q Small power relay Limiting continuous current 30A Minimal weight Low noise operation Wave (THT) and reflow (THR/pin-in-paste) solderable versions For single version refer to Single Micro Relay K
|
Original
|
086C/R2
v23086-r2802-a803
v23086-c2001-a403
v23086-c2001
v23086
V23086-C2
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: G5RL-U/-K PCB Power Relay 16 A High Switching Current, General-purpose Latching Relay • Creepage distance 8 mm between coil and contacts. • 10 kV Impulse withstand voltage. • Ambient Operating Temperature 85°C • Suitable for TV-8 rating. SPST-NO (1a
|
Original
|
K265-E1-01
|
PDF
|
latching relay G2R
Abstract: G2R-1AZ4 E41643 G2R-14 G2R-24 LR31928 G2R-1-E dpdt latching relay omron RELAY omron g2r-1 G2R-2
Text: PCB Relay G2R The Redesigned G2R Power Relay Flux protection, pre-tinned terminals now standard. 10% to 20% reduction in temperature rise at the contacts. High-sensitivity 360 mW and high-capacity (16 A) types available. Creepage distance of 8 mm min. between coil and
|
Original
|
G2R-14
G2R-24
latching relay G2R
G2R-1AZ4
E41643
G2R-14
G2R-24
LR31928
G2R-1-E
dpdt latching relay omron
RELAY omron g2r-1
G2R-2
|
PDF
|
G6A-434P-ST-US
Abstract: G6A-234P double coil latching relays pcb relay 4PDT g6ak-234p-st-us dpdt latching relay dpdt relay G6A-434P G6A-474P G6AK-234P
Text: PCB Signal Relay – G6A Fully sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment • ROHS compliant. ■ High sensitivity can be driven by digital circuits. ■ Horizontal design allows use in 1/2-inch PCB racks. ■ Impulse withstand voltage meets FCC Part 68
|
Original
|
G6A-274P-ST-US
G6A-234P-ST-US
G6A-474P-ST-US
G6A-434P-ST-US
G6A-274P-ST40
G6AU-434P-US,
G6AU-474P-ST-US
G6A-434P-ST-US
G6A-234P
double coil latching relays pcb
relay 4PDT
g6ak-234p-st-us
dpdt latching relay
dpdt relay
G6A-434P
G6A-474P
G6AK-234P
|
PDF
|
G2R-1A-T
Abstract: G2R-14 G2R-1A-H omron relay G2r-24 omron G2R2A relay omron G2r-2a G2R-24 OMRON g2r-2a G2R-2A4 CTI250
Text: PCB Relay G2R A Power Relay for a Variety of Purposes with Various Models • ■ ■ ■ ■ ■ Conforms to VDE EN61810-1 , UL508, CSA22.2. Meets EN60335-1 requirements for household products. Clearance and creepage distance: 8 mm/8 m. Models with CTI250 material available.
|
Original
|
EN61810-1)
UL508,
CSA22
EN60335-1
CTI250
G2R-14
G2R-24
K013-E1-12
G2R-1A-T
G2R-14
G2R-1A-H
omron relay G2r-24
omron G2R2A
relay omron G2r-2a
G2R-24
OMRON g2r-2a
G2R-2A4
|
PDF
|
G5A-234P
Abstract: G5AU-234P
Text: 5/10/07 15:39 Page 240 PCB Text Signal Relay – G5A Text Signal Relay – G5A PCB Sub-miniature Relay 16 x 9.9 x 8.4 mm (L x W x H with DPDT Contact Single/Double–winding Latching Types Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC • ROHS compliant.
|
Original
|
K019-E2-05A-X
G5A-234P
G5AU-234P
|
PDF
|
G6CK-2114P-US
Abstract: G6C-1114P-US G6C-1117P-US G6C-2114P-US G6C-2117P-US g6c-1117p-vd
Text: Power PCB Relay G6C • Subminiature 20.07 L x 14.99 W x 9.91 H mm 0.79 L x 0.59 W x 0.39 H in Low power consumption (200 mW) Semi-sealed and sealed types available Unique moving magnet armature (Moving Loop System) reduces relay size, magnetic interference, and contact bounce time
|
Original
|
G6C-1117P-US-DC6)
G6CK-2114P-US
G6C-1114P-US
G6C-1117P-US
G6C-2114P-US
G6C-2117P-US
g6c-1117p-vd
|
PDF
|
OMRON G2V-2 12V relay
Abstract: spdt 6v 1a relay 5V SPDT relay relay 12V, 70A OMRON G2V-2 6V relay dry contact relay 220V SRD 12VDC SL C MATSUA compressor codes 12V 30A PCB RELAY spdt relays 12v
Text: Relays New products … from the following brands: Automotive Relays PCB Relay Sockets PCB Relays Photomos Relays Plug-in Power Relays Reed Relays Solid State Relays Surface Mount 693 693 674 671 695 670 698 671 24 Top sellers High Sensitivity Relay SPDT 1A
|
Original
|
100mA
OMRON G2V-2 12V relay
spdt 6v 1a relay
5V SPDT relay
relay 12V, 70A
OMRON G2V-2 6V relay
dry contact relay 220V
SRD 12VDC SL C
MATSUA compressor codes
12V 30A PCB RELAY
spdt relays 12v
|
PDF
|
Omron
Abstract: No abstract text available
Text: G6C PCB Power Relay Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A • SPST-NO 10A and SPST-NO + SPST-NC 8A for power switching and output that satisfy the needs for space-saving. • Small High-capacity Relays Compact: 20 x 15 × 10 mm L × W × H .
|
Original
|
K018-E1-07
Omron
|
PDF
|
V23201-L
Abstract: V-2320
Text: PCB Relays Single Relays Datasheet 201-L Revision 4-2007 Power Relay PK2 Latching Description Features - 60 % volume reduced Power K at increased performance - PCB area requirements minimized by 50 % to only 293 mm 2 - Size optimized to L x W x H in mm 18.3 x 16 x 15.9
|
Original
|
V23201-L1004-A502
V23201-*
19/Reset
V23201-L
V-2320
|
PDF
|
UL File No. E41515 CSA C22.2 No. 14
Abstract: omron G6C E41515 EN61810-1 LR31928 48VDC inductive relays g6c1114pus G5CA-1A-E
Text: 5/10/07 15:39 Page 102 PCB Text Power Relay – G5CA Text Power Relay – G5CA PCB Specifications Flat Relays that Switch 10-A/15-A Loads with New Quick-connect Terminals • Coil Ratings Item Standard, high-capacity, or quick-connect terminals ■ ROHS compliant.
|
Original
|
0-A/15-A
17P-US
J151-E2-02A-X
UL File No. E41515 CSA C22.2 No. 14
omron G6C
E41515
EN61810-1
LR31928
48VDC inductive relays
g6c1114pus
G5CA-1A-E
|
PDF
|