23/isolation transformer 50 kVA
Abstract: No abstract text available
Text: Distribution Dry-Type Transformers—Low Voltage 19.0-1 November 2013 Distribution Dry-Type Transformers—Low Voltage Sheet 19 001 Contents Distribution Dry-Type Transformers—Low Voltage Glossary of Transformer Terms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19.0-2
|
Original
|
N48M28F75CUE3.
CA08104001E
23/isolation transformer 50 kVA
|
PDF
|
630 kva transformer
Abstract: cenelec hd 538 abb 1000 kVA transformer EN 50541-1 100 kva transformer 800 kva power transformer transformer 750 kVA 630 kva 22 kv Distribution transformer abb transformer abb ag
Text: Technical data EcoDry dry-type transformers Ultra-efficient dry-type transformers – a safe and economical solution ABB is committed to developing all its products to meet ever-more-demanding environmental and efficiency requirements. Our ultra-efficient dry-type transformers have been greatly improved in
|
Original
|
99Plus
630 kva transformer
cenelec hd 538
abb 1000 kVA transformer
EN 50541-1
100 kva transformer
800 kva power transformer
transformer 750 kVA
630 kva 22 kv
Distribution transformer abb
transformer abb ag
|
PDF
|
XDT3C15X
Abstract: XDT3B15X
Text: PRODUCT UPDATE Eaton’s Crouse-Hinds Business XDT Series Hazardous Location Transformers Resin Encapsulated Dry-Type Applications: Features and Benefits: Eaton’s Crouse-Hinds Hazardous Location Dry-Type Transformers are designed to operate where volatile flammable liquids or
|
Original
|
enclT3E30X
XDT3B45
XDT3B45X
XDT3C45
XDT3C45X
XDT3F45
XDT3F45X
XDT3D45
XDT3D45X
XDT3E45
XDT3C15X
XDT3B15X
|
PDF
|
TV1Y
Abstract: voltage transformer 50 kv 100VA TV1X
Text: Current and Voltage Controls Voltage Transformer Types TV1X, TV1Y • Dry-type voltage transformer • Phase-phase connection TV1X • Phase-neutral connection (TV1Y) Product Description Ordering Key Dry-type voltage transformer to be connected between 2
|
Original
|
|
PDF
|
11 CT lan Transformer
Abstract: No abstract text available
Text: 10/100 Base-T LAN Transformer RoHS ALAN-10ANL-13FA MSL level: 2 This product is packed with dry packaging 13.00 x 7.40 x 4.00mm Compliant | | | | | | | | | | | | | | STANDARD SPECIFICATIONS: Parameters Minimum Typical Maximum Units Operating Temperature
|
Original
|
ALAN-10ANL-13FA
20log
100KHz/0
5MHz-100MHz
5MHz-30MHz
1MHz-60MHz
1MHz-80MHz
ISO9001
11 CT lan Transformer
|
PDF
|
CTR21
Abstract: isolation transformer v.92
Text: ESMIT-3356 Analog Telephony/Modem Couplers FEATURES DESCRIPTION The Sumida ESMIT-3356 is a "Dry" Encapsulated SMT Modem Isolation Transformer suitable for up to V.92 56 kbps analog modem and voice applications requiring SMT and small PCB footprint. ESMIT-3356
|
Original
|
ESMIT-3356
ESMIT-3356
EN60950
CTR21
isolation transformer v.92
|
PDF
|
EMIT-1200L
Abstract: CTR21 emit-1200-l
Text: EMIT-1200L Analog Telephony/Modem Couplers DESCRIPTION FEATURES • Suitable for modem speeds up to V.32bis 14.4 kbps . The Sumida EMIT-1200L is a "Dry" Encapsulated Modem Isolation Transformer suitable for up to V.32bis (14.4 kbps) fax, computer telephony,
|
Original
|
EMIT-1200L
32bis
EMIT-1200L
IEC60950
EMIT1200L
CTR21
1250L
emit-1200-l
|
PDF
|
Sumida
Abstract: EMIT-1250L 813 tube CTR21 EMIT-1200L Sumida Corporation
Text: EMIT-1250L Analog Telephony/Modem Couplers DESCRIPTION FEATURES • Suitable for modem speeds up to V.32bis 14.4 kbps . The Sumida EMIT-1250L is a "Dry" Encapsulated Modem Isolation Transformer suitable for up to V.32bis (14.4 kbps) fax, computer telephony,
|
Original
|
EMIT-1250L
32bis
EMIT-1250L
IEC60950
EMIT1250L
CTR21
1250L
Sumida
813 tube
EMIT-1200L
Sumida Corporation
|
PDF
|
EMIT-1200L
Abstract: CTR21 EMIT-1200 sumida khz
Text: EMIT-1200L Analog Telephony/Modem Couplers DESCRIPTION FEATURES • Suitable for modem speeds up to V.32bis 14.4 kbps . The Sumida EMIT-1200L is a "Dry" Encapsulated Modem Isolation Transformer suitable for up to V.32bis (14.4 kbps) fax, computer telephony,
|
Original
|
EMIT-1200L
32bis
EMIT-1200L
IEC60950
EMIT1200L
CTR21
1250L
EMIT-1200
sumida khz
|
PDF
|
es5h50s
Abstract: ET2H30 ET2H15S ET5H75 ET2H45S ET79H45S at 5588 E25872 ET79H75S distribution transformers
Text: 5 Ventilated Distribution Transformers General Purpose Energy efficient dry-type transformers 600 Volt Class, isolation type, single and three phase, 15 kVA through 500 kVA. Indoor and outdoor models available. Accessories and Optional Design Styles • Electrostatic shield for quality power
|
Original
|
|
PDF
|
CTR21
Abstract: isolation transformer v.92 ANALOG DEVICES COUNTRY OF ORIGIN
Text: ESMIT-3300 Analog Telephony/Modem Couplers FEATURES DESCRIPTION The Sumida ESMIT-3300 is a "Dry" encapsulated Modem Isolation Transformer suitable for up to V.92 56 kbps analog modem and voice applications requiring SMT and small PCB footprint. ESMIT-3300
|
Original
|
ESMIT-3300
ESMIT-3300
EN60950
profi-20
CTR21
isolation transformer v.92
ANALOG DEVICES COUNTRY OF ORIGIN
|
PDF
|
EMIT-2001L
Abstract: schematic sumida EMIT-2001 CTR21
Text: EMIT-2001L Analog Telephony/Modem Couplers DESCRIPTION FEATURES • Suitable for modem speeds up to V.34 33.6 kbps . The Sumida EMIT -2001L is a "Dry" Encapsulated Modem Isolation Transformer suitable for up to V.34 (33.6 kbps) consumer and internet analog
|
Original
|
EMIT-2001L
-2001L
EMIT-2001L
EMIT-2001
IEC60950
CTR21
schematic sumida
|
PDF
|
EMIT-4033L
Abstract: EMIT4033L CTR21 EMIT-4035L EMIT-5035L isolation transformer v.92 isolation transformer v.90 4033l
Text: EMIT-4033L Analog Telephony/Modem Couplers FEATURES DESCRIPTION • Suitable for modem speeds up to V.92 56 kbps . The Sumida EMIT-4033L is a "Dry" Encapsulated Modem Isolation Transformer suitable for up to V.92 (56 kbps) modem applications compliant with International
|
Original
|
EMIT-4033L
EMIT-4033L
600Hz,
IEC60950
EMIT-4035L
EMIT-5035L
4033L
EMIT4033L
CTR21
EMIT-5035L
isolation transformer v.92
isolation transformer v.90
4033l
|
PDF
|
SMIT-2412
Abstract: 30089
Text: SMIT-2412 Analog Telephony/Modem Couplers DESCRIPTION FEATURES The Sumida SMIT-2412 is a "Dry" SMT Modem Isolation Transformer suitable for up to V.34 33.6 kbps analog modem applications requiring exceptionally small size and thin profile compliant with Domestic safety norms.
|
Original
|
SMIT-2412
SMIT-2412
UL1459
30089
|
PDF
|
|
Sumida DATE CODE
Abstract: TA 8264 analog 8264 CTR21 ESMIT-300
Text: ESMIT-300 Analog Telephony/Modem Couplers FEATURES DESCRIPTION The Sumida ESMIT-300 is a "Dry" Encapsulated SMT Modem Isolation Transformer suitable for up to V.34 33.6 kbps analog modem and voice applications requiring SMT and small PCB footprint. ESMIT-300 complies with International
|
Original
|
ESMIT-300
ESMIT-300
IEC60950
no-20
CTR21
Sumida DATE CODE
TA 8264 analog
8264
|
PDF
|
100 kva transformer
Abstract: delta transformer
Text: GENERAL _ _ ACME TRANSFORMER SPECIFICATIONS Specification Guide for Dry Type Distribution Transformers, Including Opti-Miser 30KVA and Larger 1.0 Dry type transform ers: 1.0. 1 Provide dry type, enclosed and ventilated transformers as indi
|
OCR Scan
|
30KVA
100 kva transformer
delta transformer
|
PDF
|
Untitled
Abstract: No abstract text available
Text: GENERAL ACM E TRANSFORM ER SPECIFICATIONS Specification Guide for Dry ly p e Distribution Transformers, Including Opti-Miser 30KVA and Lar •er 1.0 Dry type transformers: 1 .0 . 1 Provide dry type, enclosed and ventilated transformers as indi cated herein. Transformers
|
OCR Scan
|
30KVA
|
PDF
|
SPT-129
Abstract: No abstract text available
Text: Telephony/Audio Prem Magnetics, Inc, Economy Audio Dry No DC Coupling Transformers IMPEDANCE DC RESISTANCE W M EM T SIZE Q DESCRIPTION PRI • Metric size, low cost audio transformers - units on this page imported from offshore - not manufactured by Prem.
|
OCR Scan
|
SPT-203
SPT-201
1000VAC
Ei-14
075WATTS
El-16
100WATTS
El-19
200WATTS
El-24
SPT-129
|
PDF
|
Untitled
Abstract: No abstract text available
Text: DRY-TYPE DISTRIBUTION TRANSFORMERS SECTION I Steps for Selecting the Proper TVansformer SINGLE PHASE LOADS 1 . Determine electrical load 1 To determine KVA when volts and amperes are known: KVA = 1000 A . Voltage required by load. B. Amperes or KVA capacity
|
OCR Scan
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SECTION I DRY-TYPE DISTRIBUTION TRANSFORMERS Steps for Selecting the Proper Transformer 1 To determine KVA when volts and amperes are known: = Volts x Amps 1. Determine electrical load A. Voltage required by load. B. Amperes or KVA capacity required by load.
|
OCR Scan
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: DRY-TYPE DISTRIBUTION TRANSFORMERS SECTION I Selection Charts_ SINGLE PHASE <§ GROUP I 240 X 480 PRIMARY VOLTS — 120/240 SECONDARY VOLTS — FOUR WINDING — 10,60 Hz KVA CATALOG NO. ' .05 T-1- 5 3 0 0 4 APPROX. DIMENSIONS
|
OCR Scan
|
T-1-53005
TE-2-53Q20-3S
TE-1-53022-3S
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Daykin Transformers Daykin Electric Corporation has designed a line of dry type transformers of the highest dependability. Our design engineers specify only quality materials to maximize the best electrical and thermal characteristics for years of reliable service. All Daykin Transformers utilize 100% copper
|
OCR Scan
|
|
PDF
|
8904C-F+delta
Abstract: No abstract text available
Text: DRY-TYPE DISTRIBUTION TRANSFORMERS SECTION I Do You Have a Non-Standard Three Phase Voltage Application?_ M any non-standard voltage correction problems can be solved by using standard off-the-shelf single phase transformers. The following is a list of such voltage
|
OCR Scan
|
208Y/120
Delta/120
416Y/240
3227-A
8904C-F+delta
|
PDF
|
TTC-02
Abstract: No abstract text available
Text: ^7 TELECOMMUNICATION DRY COUPLING TRANSFORMER DESIGNED TO OPERATE AT A MAX LEVEL OF +7dBm AND TO REFLECT A PRIMARY SOURCE IMPEDANCE OF APPROXIMATELY 6000 WITH 6000 LOAD ON SECONDARY TAAM2J3A REV. S tatus 01 L±J m CN O A. Electrical Specifications @ 25° C
|
OCR Scan
|
UL1459
UL1863.
ACAD\TTC\A1105181
TTC-02
|
PDF
|