Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    DRY TRANSFORMER Search Results

    DRY TRANSFORMER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    WB1040-SML Coilcraft Inc Transformer Visit Coilcraft Inc
    AS8426-A Coilcraft Inc Telecom Transformer Visit Coilcraft Inc Buy
    B0727-B Coilcraft Inc Telecom Transformer Visit Coilcraft Inc Buy
    AS8954-A Coilcraft Inc Telecom Transformer Visit Coilcraft Inc
    CR7984-CLD Coilcraft Inc Datacom Transformer Visit Coilcraft Inc

    DRY TRANSFORMER Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    23/isolation transformer 50 kVA

    Abstract: No abstract text available
    Text: Distribution Dry-Type Transformers—Low Voltage 19.0-1 November 2013 Distribution Dry-Type Transformers—Low Voltage Sheet 19 001 Contents Distribution Dry-Type Transformers—Low Voltage Glossary of Transformer Terms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19.0-2


    Original
    N48M28F75CUE3. CA08104001E 23/isolation transformer 50 kVA PDF

    630 kva transformer

    Abstract: cenelec hd 538 abb 1000 kVA transformer EN 50541-1 100 kva transformer 800 kva power transformer transformer 750 kVA 630 kva 22 kv Distribution transformer abb transformer abb ag
    Text: Technical data EcoDry dry-type transformers Ultra-efficient dry-type transformers – a safe and economical solution ABB is committed to developing all its products to meet ever-more-demanding environmental and efficiency requirements. Our ultra-efficient dry-type transformers have been greatly improved in


    Original
    99Plus 630 kva transformer cenelec hd 538 abb 1000 kVA transformer EN 50541-1 100 kva transformer 800 kva power transformer transformer 750 kVA 630 kva 22 kv Distribution transformer abb transformer abb ag PDF

    XDT3C15X

    Abstract: XDT3B15X
    Text: PRODUCT UPDATE Eaton’s Crouse-Hinds Business XDT Series Hazardous Location Transformers Resin Encapsulated Dry-Type Applications: Features and Benefits: Eaton’s Crouse-Hinds Hazardous Location Dry-Type Transformers are designed to operate where volatile flammable liquids or


    Original
    enclT3E30X XDT3B45 XDT3B45X XDT3C45 XDT3C45X XDT3F45 XDT3F45X XDT3D45 XDT3D45X XDT3E45 XDT3C15X XDT3B15X PDF

    TV1Y

    Abstract: voltage transformer 50 kv 100VA TV1X
    Text: Current and Voltage Controls Voltage Transformer Types TV1X, TV1Y • Dry-type voltage transformer • Phase-phase connection TV1X • Phase-neutral connection (TV1Y) Product Description Ordering Key Dry-type voltage transformer to be connected between 2


    Original
    PDF

    11 CT lan Transformer

    Abstract: No abstract text available
    Text: 10/100 Base-T LAN Transformer RoHS ALAN-10ANL-13FA MSL level: 2 This product is packed with dry packaging 13.00 x 7.40 x 4.00mm Compliant | | | | | | | | | | | | | | STANDARD SPECIFICATIONS: Parameters Minimum Typical Maximum Units Operating Temperature


    Original
    ALAN-10ANL-13FA 20log 100KHz/0 5MHz-100MHz 5MHz-30MHz 1MHz-60MHz 1MHz-80MHz ISO9001 11 CT lan Transformer PDF

    CTR21

    Abstract: isolation transformer v.92
    Text: ESMIT-3356 Analog Telephony/Modem Couplers FEATURES DESCRIPTION The Sumida ESMIT-3356 is a "Dry" Encapsulated SMT Modem Isolation Transformer suitable for up to V.92 56 kbps analog modem and voice applications requiring SMT and small PCB footprint. ESMIT-3356


    Original
    ESMIT-3356 ESMIT-3356 EN60950 CTR21 isolation transformer v.92 PDF

    EMIT-1200L

    Abstract: CTR21 emit-1200-l
    Text: EMIT-1200L Analog Telephony/Modem Couplers DESCRIPTION FEATURES • Suitable for modem speeds up to V.32bis 14.4 kbps . The Sumida EMIT-1200L is a "Dry" Encapsulated Modem Isolation Transformer suitable for up to V.32bis (14.4 kbps) fax, computer telephony,


    Original
    EMIT-1200L 32bis EMIT-1200L IEC60950 EMIT1200L CTR21 1250L emit-1200-l PDF

    Sumida

    Abstract: EMIT-1250L 813 tube CTR21 EMIT-1200L Sumida Corporation
    Text: EMIT-1250L Analog Telephony/Modem Couplers DESCRIPTION FEATURES • Suitable for modem speeds up to V.32bis 14.4 kbps . The Sumida EMIT-1250L is a "Dry" Encapsulated Modem Isolation Transformer suitable for up to V.32bis (14.4 kbps) fax, computer telephony,


    Original
    EMIT-1250L 32bis EMIT-1250L IEC60950 EMIT1250L CTR21 1250L Sumida 813 tube EMIT-1200L Sumida Corporation PDF

    EMIT-1200L

    Abstract: CTR21 EMIT-1200 sumida khz
    Text: EMIT-1200L Analog Telephony/Modem Couplers DESCRIPTION FEATURES • Suitable for modem speeds up to V.32bis 14.4 kbps . The Sumida EMIT-1200L is a "Dry" Encapsulated Modem Isolation Transformer suitable for up to V.32bis (14.4 kbps) fax, computer telephony,


    Original
    EMIT-1200L 32bis EMIT-1200L IEC60950 EMIT1200L CTR21 1250L EMIT-1200 sumida khz PDF

    es5h50s

    Abstract: ET2H30 ET2H15S ET5H75 ET2H45S ET79H45S at 5588 E25872 ET79H75S distribution transformers
    Text: 5 Ventilated Distribution Transformers General Purpose Energy efficient dry-type transformers 600 Volt Class, isolation type, single and three phase, 15 kVA through 500 kVA. Indoor and outdoor models available. Accessories and Optional Design Styles • Electrostatic shield for quality power


    Original
    PDF

    CTR21

    Abstract: isolation transformer v.92 ANALOG DEVICES COUNTRY OF ORIGIN
    Text: ESMIT-3300 Analog Telephony/Modem Couplers FEATURES DESCRIPTION The Sumida ESMIT-3300 is a "Dry" encapsulated Modem Isolation Transformer suitable for up to V.92 56 kbps analog modem and voice applications requiring SMT and small PCB footprint. ESMIT-3300


    Original
    ESMIT-3300 ESMIT-3300 EN60950 profi-20 CTR21 isolation transformer v.92 ANALOG DEVICES COUNTRY OF ORIGIN PDF

    EMIT-2001L

    Abstract: schematic sumida EMIT-2001 CTR21
    Text: EMIT-2001L Analog Telephony/Modem Couplers DESCRIPTION FEATURES • Suitable for modem speeds up to V.34 33.6 kbps . The Sumida EMIT -2001L is a "Dry" Encapsulated Modem Isolation Transformer suitable for up to V.34 (33.6 kbps) consumer and internet analog


    Original
    EMIT-2001L -2001L EMIT-2001L EMIT-2001 IEC60950 CTR21 schematic sumida PDF

    EMIT-4033L

    Abstract: EMIT4033L CTR21 EMIT-4035L EMIT-5035L isolation transformer v.92 isolation transformer v.90 4033l
    Text: EMIT-4033L Analog Telephony/Modem Couplers FEATURES DESCRIPTION • Suitable for modem speeds up to V.92 56 kbps . The Sumida EMIT-4033L is a "Dry" Encapsulated Modem Isolation Transformer suitable for up to V.92 (56 kbps) modem applications compliant with International


    Original
    EMIT-4033L EMIT-4033L 600Hz, IEC60950 EMIT-4035L EMIT-5035L 4033L EMIT4033L CTR21 EMIT-5035L isolation transformer v.92 isolation transformer v.90 4033l PDF

    SMIT-2412

    Abstract: 30089
    Text: SMIT-2412 Analog Telephony/Modem Couplers DESCRIPTION FEATURES The Sumida SMIT-2412 is a "Dry" SMT Modem Isolation Transformer suitable for up to V.34 33.6 kbps analog modem applications requiring exceptionally small size and thin profile compliant with Domestic safety norms.


    Original
    SMIT-2412 SMIT-2412 UL1459 30089 PDF

    Sumida DATE CODE

    Abstract: TA 8264 analog 8264 CTR21 ESMIT-300
    Text: ESMIT-300 Analog Telephony/Modem Couplers FEATURES DESCRIPTION The Sumida ESMIT-300 is a "Dry" Encapsulated SMT Modem Isolation Transformer suitable for up to V.34 33.6 kbps analog modem and voice applications requiring SMT and small PCB footprint. ESMIT-300 complies with International


    Original
    ESMIT-300 ESMIT-300 IEC60950 no-20 CTR21 Sumida DATE CODE TA 8264 analog 8264 PDF

    100 kva transformer

    Abstract: delta transformer
    Text: GENERAL _ _ ACME TRANSFORMER SPECIFICATIONS Specification Guide for Dry Type Distribution Transformers, Including Opti-Miser 30KVA and Larger 1.0 Dry type transform ers: 1.0. 1 Provide dry type, enclosed and ventilated transformers as indi­


    OCR Scan
    30KVA 100 kva transformer delta transformer PDF

    Untitled

    Abstract: No abstract text available
    Text: GENERAL ACM E TRANSFORM ER SPECIFICATIONS Specification Guide for Dry ly p e Distribution Transformers, Including Opti-Miser 30KVA and Lar •er 1.0 Dry type transformers: 1 .0 . 1 Provide dry type, enclosed and ventilated transformers as indi­ cated herein. Transformers


    OCR Scan
    30KVA PDF

    SPT-129

    Abstract: No abstract text available
    Text: Telephony/Audio Prem Magnetics, Inc, Economy Audio Dry No DC Coupling Transformers IMPEDANCE DC RESISTANCE W M EM T SIZE Q DESCRIPTION PRI • Metric size, low cost audio transformers - units on this page imported from offshore - not manufactured by Prem.


    OCR Scan
    SPT-203 SPT-201 1000VAC Ei-14 075WATTS El-16 100WATTS El-19 200WATTS El-24 SPT-129 PDF

    Untitled

    Abstract: No abstract text available
    Text: DRY-TYPE DISTRIBUTION TRANSFORMERS SECTION I Steps for Selecting the Proper TVansformer SINGLE PHASE LOADS 1 . Determine electrical load 1 To determine KVA when volts and amperes are known: KVA = 1000 A . Voltage required by load. B. Amperes or KVA capacity


    OCR Scan
    PDF

    Untitled

    Abstract: No abstract text available
    Text: SECTION I DRY-TYPE DISTRIBUTION TRANSFORMERS Steps for Selecting the Proper Transformer 1 To determine KVA when volts and amperes are known: = Volts x Amps 1. Determine electrical load A. Voltage required by load. B. Amperes or KVA capacity required by load.


    OCR Scan
    PDF

    Untitled

    Abstract: No abstract text available
    Text: DRY-TYPE DISTRIBUTION TRANSFORMERS SECTION I Selection Charts_ SINGLE PHASE <§ GROUP I 240 X 480 PRIMARY VOLTS — 120/240 SECONDARY VOLTS — FOUR WINDING — 10,60 Hz KVA CATALOG NO. ' .05 T-1- 5 3 0 0 4 APPROX. DIMENSIONS


    OCR Scan
    T-1-53005 TE-2-53Q20-3S TE-1-53022-3S PDF

    Untitled

    Abstract: No abstract text available
    Text: Daykin Transformers Daykin Electric Corporation has designed a line of dry type transformers of the highest dependability. Our design engineers specify only quality materials to maximize the best electrical and thermal characteristics for years of reliable service. All Daykin Transformers utilize 100% copper


    OCR Scan
    PDF

    8904C-F+delta

    Abstract: No abstract text available
    Text: DRY-TYPE DISTRIBUTION TRANSFORMERS SECTION I Do You Have a Non-Standard Three Phase Voltage Application?_ M any non-standard voltage correction problems can be solved by using standard off-the-shelf single phase transformers. The following is a list of such voltage


    OCR Scan
    208Y/120 Delta/120 416Y/240 3227-A 8904C-F+delta PDF

    TTC-02

    Abstract: No abstract text available
    Text: ^7 TELECOMMUNICATION DRY COUPLING TRANSFORMER DESIGNED TO OPERATE AT A MAX LEVEL OF +7dBm AND TO REFLECT A PRIMARY SOURCE IMPEDANCE OF APPROXIMATELY 6000 WITH 6000 LOAD ON SECONDARY TAAM2J3A REV. S tatus 01 L±J m CN O A. Electrical Specifications @ 25° C


    OCR Scan
    UL1459 UL1863. ACAD\TTC\A1105181 TTC-02 PDF