Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    DUAL ELEMENT TIME-DELAY FUSE Search Results

    DUAL ELEMENT TIME-DELAY FUSE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCKE800NA Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE800NL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE812NA Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE812NL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, Fixed Over Voltage Clamp, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE712BNL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 13.2 V, 3.65 A, Latch, Adjustable Over Voltage Protection, WSON10 Visit Toshiba Electronic Devices & Storage Corporation

    DUAL ELEMENT TIME-DELAY FUSE Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: Low Voltage, Branch Circuit Rated Fuses Fusetron Energy Efficient, Dual-element, Time-delay Fuses Time-Current Characteristic Curves—Average Melt FRS-R 600V Class RK5 Specifications Description: Dual-element, time-delay fuse – 10 seconds (minimum) at 500%


    Original
    PDF 600Vac 0-30A 200kA 300Vdc 5-60A 250Vdc E4273, FRS-R-12* FRS-R-10*

    FRSR.250

    Abstract: tube 1A2
    Text: Low Voltage, Branch Circuit Rated Fuses Fusetron dual-element, time-delay fuses Time-Current Characteristic Curves—Average Melt FRS-R 600V Class RK5 Specifications Description: Dual-element, time-delay fuse – 10 seconds (minimum) at 500% rated amps.


    Original
    PDF 600Vac 300Vdc 0-600A E4273, FRS-R-110 FRS-R-12 FRS-R-10 FRSR.250 tube 1A2

    Untitled

    Abstract: No abstract text available
    Text: FUSETRON 600V Class RK5 FRS-R — 600Vac/300Vdc, 65-600A, Dual Element, Time-Delay Fuses Dimensions - in A B Description: Advanced protection, energy efficient Class RK5 dual element, current-limiting, time-delay fuses. Time-delay – 10 seconds minimum at 500% of rated current.


    Original
    PDF 600Vac/300Vdc, 5-600A, 600Vac, 300Vdc 5-600A 200kA E4273 FRS-R-65 FRS-R-70 FRS-R-75

    E56412

    Abstract: TCF15 TCF30 TCF35 TCF50 TCFH100
    Text: Bussmann CUBEFuseTM and Fuseholder TCF & TCFH Finger-Safe Dual-Element Time-Delay Fuses Indicating – 600 Volts or Less Catalog Symbol: TCF Fuse & TCFH (Holder) Dual-Element, Time-Delay Fuse: 10 Seconds Minimum Operating Time at 500% Rated Current Ampere Rating: 1 to 100A


    Original
    PDF 600Vac E56412 E214079 50-1000Vac, TCFH100) 10Hz-60Hz-10Hz SB03305 E56412 TCF15 TCF30 TCF35 TCF50 TCFH100

    15sp

    Abstract: No abstract text available
    Text: Low Voltage, Branch Circuit Rated Fuses Low-Peak dual-element, time-delay fuses LPN-RK_SP 250V Class RK1 LPS-RK_SP (600V) Class RK1 Now Available With Optional Indication Specifications Description: Current-limiting, dual-element, time-delay fuse; 10 seconds


    Original
    PDF 250Vac 125Vdc 250Vdc 0-600A) 600Vac 300Vdc 0-600A 250VFuses 15sp

    CDA7025

    Abstract: TCF40 A0201 E56412 TCF15 TCF30 TCF35 TCF50 thermal fuse symbol motors starters
    Text: Bussmann CUBEFuseTM and Fuseholder TCF & TCFH Finger-Safe Dual-Element Time-Delay Fuses Indicating – 600 Volts or Less Catalog Symbol: TCF Fuse & TCFH (Holder) Dual-Element, Time-Delay Fuse: 10 Seconds Minimum Operating Time at 500% Rated Current Ampere Rating: 1 to 60 Amperes


    Original
    PDF E56412 E214079 CDA7025 10Hz-60Hz-10Hz A02016 CDA7025 TCF40 A0201 E56412 TCF15 TCF30 TCF35 TCF50 thermal fuse symbol motors starters

    TCFH60

    Abstract: K30a CSA-22 TCF10 TCF15 TCF30 TCF35 TCF50 dual element Time-Delay fuse
    Text: Bussmann¨ CUBEFuseª and Fuseholder TCF & TCFH Finger-Safe Dual-Element Time-Delay Fuses Indicating Ð 600 Volts or Less Catalog Symbol: TCF Fuse & TCFH (Holder) Dual-Element, Time-Delay Fuse: 10 Seconds Minimum Operating Time at 500% Rated Current Ampere Rating: 1 to 60 Amperes


    Original
    PDF CSA-22 0-1000V 5-1500V 000AIR TCFH60 K30a TCF10 TCF15 TCF30 TCF35 TCF50 dual element Time-Delay fuse

    CSA-22

    Abstract: TCF15 TCF30 TCF35 TCF50 K30A
    Text: Bussmann¨ CUBEFuseª and Fuseholder TCF & TCFH Finger-Safe Dual-Element Time-Delay Fuses Indicating Ð 600 Volts or Less Catalog Symbol: TCF Fuse & TCFH (Holder) Dual-Element, Time-Delay Fuse: 10 Seconds Minimum Operating Time at 500% Rated Current Ampere Rating: 1 to 60 Amperes


    Original
    PDF 5-60A) CSA-22 0-1000V 5-1500V TCF15 TCF30 TCF35 TCF50 K30A

    R25060-3CR

    Abstract: r25030-2pr r2503 LENRK15 R250302CR R250301CR R25030-1PR IR-200ka R250303CR R250302SR
    Text: Edison LENRK Class RK1 250Vac, 0.2 to 60A Dual-Element, Time-Delay Fuses Dimensions inches Catalog Symbol: LENRK Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current (8 seconds for 0-30A sizes) Current-Limiting Volts: 250Vac (or less)


    Original
    PDF 250Vac, 250Vac 200kA 300kA E162363, 000AIR) BU-SB07255 R25060-3CR r25030-2pr r2503 LENRK15 R250302CR R250301CR R25030-1PR IR-200ka R250303CR R250302SR

    DLSR.200

    Abstract: No abstract text available
    Text: Low Voltage, Branch Circuit Rated Fuses Dura-Lag dual-element, time-delay fuses DLS-R 600V Class RK5 Specifications Description: Dual-element, time-delay fuse – 10 seconds (minimum) at 500% rated amps. Dimensions: See page 11 for Class RK5 dimensions.


    Original
    PDF 250Vac E4273, locaR-40 DLS-R-250 DLS-R-45 DLS-R-300 DLS-R-50 DLS-R-350 DLS-R-60 DLS-R-400 DLSR.200

    6-60A

    Abstract: E4273
    Text: Fusetron FRS-R_ID Dual-Element, Time-Delay Fuses with Indication Class RK5 - 600 Volt Now Available With Optional Indication Catalog Symbol: FRS-R_ID Current-Limiting Dual-element, time-delay – 10 seconds minimum at 500% rated current Ratings: Volts – 600Vac (or less)


    Original
    PDF 600Vac 200kA 250Vdc E4273 FRS-R-30ID BU-SB08206 6-60A E4273

    Untitled

    Abstract: No abstract text available
    Text: Low-Peak 250V Class RK1 LPN-RK — 250Vac/dc, 70-600A, Dual Element, Time-Delay Fuses Dimensions - in A B Available with easyID™ open fuse indication Description: Ultimate protection Class RK1 dual element, current-limiting, time-delay fuses available with optional open


    Original
    PDF 250Vac/dc, 0-600A, 250Vac/dc 0-600A 300kA 100kA E4273 LPN-RK-70SP LPN-RK-150SP LPN-RK-350SP

    R60030-1PR

    Abstract: R60030-2PR R60060-3PR R60030-2SR R600303CR E162363 R60030-3CR R60030-1SR R60030-2CR R6003
    Text: Edison LESRK Class RK1 600Vac, 0.25 to 60A Dual-Element, Time-Delay Fuses Dimensions inches Catalog Symbol: LESRK Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Current-Limiting Volts: 600Vac (or less) Amps: 0.25 to 60A IR: 200kA RMS Sym.


    Original
    PDF 600Vac, 600Vac 200kA 300kA E162363, 000AIR) BU-SB07255 R60030-1PR R60030-2PR R60060-3PR R60030-2SR R600303CR E162363 R60030-3CR R60030-1SR R60030-2CR R6003

    R25060-1

    Abstract: ECNR20 ECNR30 E162363 ECNR35 ECNR40 RK5 fuse ECN-R40 ECNR45 ECNR10
    Text: ECNR Class RK5 250Vac, 1 to 60A Dual-Element, Time-Delay Fuses Dimensions inches Catalog Symbol: ECNR Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current (8 seconds for fuses 30A or less) Current-Limiting Volts: 250Vac (or less) 125Vdc (or less)


    Original
    PDF 250Vac, 250Vac 125Vdc 200kA E162363, ECNR17 ECNR20 ECNR25 ECNR10 ECNR30 R25060-1 ECNR20 ECNR30 E162363 ECNR35 ECNR40 RK5 fuse ECN-R40 ECNR45 ECNR10

    FRN-R-50ID

    Abstract: No abstract text available
    Text: Fusetron FRN-R_ID Dual-Element, Time-Delay Fuses with Indication Class RK5 - 250 Volt Catalog Symbol: FRN-R_ID Current-Limiting Dual-element, time-delay – 10 seconds minimum at 500% rated current (8 seconds for 0-30A sizes) Ratings: Volts – 250Vac (or less)


    Original
    PDF 250Vac 200kA 125Vdc E4273 BU-SB09408 FRN-R-50ID

    Untitled

    Abstract: No abstract text available
    Text: Low-Peak 600V Class RK1 LPS-RK — 600Vac/300Vdc, 1⁄10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5.5" ± 0.31 5" (± 0.31) 1/10 to 30A Description: Ultimate protection Class RK1 dual element, current-limiting, time-delay fuses available with optional open


    Original
    PDF 600Vac/300Vdc, 0-60A, 600Vac, 300Vdc 0-60A 300kA 100kA E4273 LPS-RK-11â BU-SB13684

    LPS-RK-30SPI

    Abstract: LPS-RK-15SPI BU 527 6-60A E56412 LPS-RK-35SPI Class R 600V fuses no 1111 LPS-RK-60SP LPSRK50SPI special purpose fuses cooper bussmann
    Text: LOW-PEAK LPS-RK_SPI 6-60A Dual-Element, Time-Delay Fuses w/Permanent Fuse Indication Class RK1 – 600V Dimensional Data 5.5" ± 0.31 5" (± 0.31) .81" (±0.008) 6A to 30A Catalog Symbol: LPS-RK_SPI Dual-Element, Time-Delay – 10 seconds (minimum) at 500%


    Original
    PDF 600Vac 300Vdc E56412 000AIR) BU-SB07268 LPS-RK-30SPI LPS-RK-15SPI BU 527 6-60A E56412 LPS-RK-35SPI Class R 600V fuses no 1111 LPS-RK-60SP LPSRK50SPI special purpose fuses cooper bussmann

    JDL400

    Abstract: JDL125 JDL450 JDL110 JDL100 JDL-250 JDL70 E162363 JDL80 JDL90
    Text: Edison JDL Class J 600 Volt, 70 to 600A Dual-Element, Time-Delay Fuses Dimensions inches Catalog Symbol: JDL Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Current-Limiting Volts: 600Vac (or less) Amps: 70 to 600A IR: 200kA RMS Sym


    Original
    PDF 600Vac 200kA 300kA E162363, BU-SB07255 JDL400 JDL125 JDL450 JDL110 JDL100 JDL-250 JDL70 E162363 JDL80 JDL90

    fusetron

    Abstract: FRSR-400 fusetron dual element Time-Delay fuse FRSR300 FRS-R-175 FRSR125 FRS-R-125 FRSR.250 FRS-R-200 FRSR225
    Text: Bussmann Fusetron® FRS-R Dual-Element, Time-Delay Fuses Class RK5 –– 600 Volt 65-600A Dimensional Data A B Dimensions inches Ampere Ratings 65-100 110-200 225-400 450-600 Catalog Symbol: FRS-R Dual-Element, Time-Delay – 10 seconds (minimum) at 500%


    Original
    PDF 5-600A 600Vac 000AIC 300Vdc) E4273 FRS-R-65 FRS-R-135 FRS-R-325 FRS-R-70 FRS-R-150 fusetron FRSR-400 fusetron dual element Time-Delay fuse FRSR300 FRS-R-175 FRSR125 FRS-R-125 FRSR.250 FRS-R-200 FRSR225

    Untitled

    Abstract: No abstract text available
    Text: 1/4" x 1-1/4" Fuses MDQ Series Dual Element, Time Delay, Glass Fuse Description • Dual element, time delay • 1/4" x 1-1/4" 6.3mm x 32mm physical size • Glass tube, nickel-plated brass endcap construction • UL Listed product meets standard 248-14


    Original
    PDF 1/16A MDQ-1/16 E19180) MDQ-1/100 OC-91

    GLASS Fuse

    Abstract: MDQ30
    Text: 1/4" x 1-1/4" Fuses MDQ Series Dual Element, Time Delay, Glass Fuse Description • Dual element, time delay • 1/4" x 1-1/4" 6.3mm x 32mm physical size • Glass tube, nickel-plated brass endcap construction • UL Listed product meets standard 248-14


    Original
    PDF 1/16A MDQ-1/16 E19180) MDQ-1/100 MDQ-1/10 GLASS Fuse MDQ30

    FRS-R-80

    Abstract: FRSR-400 8002 1018 FRS-R-300 FRSR-80 FRSR-175 frs-r-400 FRS-R-175 FRSR600 FRS-R-200
    Text: Bussmann Fusetron® FRS-R Dual-Element, Time-Delay Fuses Class RK5 –– 600 Volt 65-600A Dimensional Data A B Dimensions inches Ampere Ratings 65-100 110-200 225-400 450-600 Catalog Symbol: FRS-R Dual-Element, Time-Delay – 10 seconds (minimum) at 500%


    Original
    PDF 5-600A 000AIC E4273 FRS-R-65 FRS-R-125 FRS-R-300 FRS-R-70 FRS-R-135 FRS-R-325 FRS-R-75 FRS-R-80 FRSR-400 8002 1018 FRS-R-300 FRSR-80 FRSR-175 frs-r-400 FRS-R-175 FRSR600 FRS-R-200

    JDL20

    Abstract: JDL40 J60060-3CR E162363 JDL2.5 JDL30 JDL6 J60030-3C JDL-20 JDL3
    Text: JDL Class J 600Vac, 1 to 60A Dual-Element, Time-Delay Fuses Dimensions inches Catalog Symbol: JDL Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Current-Limiting Volts: 600Vac (or less) Amps: 1 to 60A IR: 200kA RMS Sym. 300kA RMS Sym. (self certified)


    Original
    PDF 600Vac, 600Vac 200kA 300kA E162363, BU-SB07255 JDL20 JDL40 J60060-3CR E162363 JDL2.5 JDL30 JDL6 J60030-3C JDL-20 JDL3

    r60200-3cr

    Abstract: FRS-R75 BU-SB08062 FRSR-175 FRS-R-100 FRS-R-110 FRS-R-125 FRS-R-70 FRS-R-75 FRS-R-80
    Text: Fusetron FRS-R Dual-Element, Time-Delay Fuses Class RK5 –– 600 Volt 65-600A Dimensions - in A B Amp Ratings 65-100 110-200 225-400 450-600 Catalog Symbol: FRS-R Current-Limiting, dual-element, time-delay – 10 seconds minimum at 500% rated current


    Original
    PDF 5-600A 600Vac 200kA 300Vdc E4273 FRS-R-65 FRS-R-125 FRS-R-350 FRS-R-70 r60200-3cr FRS-R75 BU-SB08062 FRSR-175 FRS-R-100 FRS-R-110 FRS-R-125 FRS-R-70 FRS-R-75 FRS-R-80