edison
Abstract: bussmann Fuse base Edison Plug Fuse TLO 61
Text: “T” AND “TL” EDISON BASE PLUG FUSES Catalog Number TL 15 - 30A 125 Volts AC or Less Edison Base Time-Delay Catalog Number T (3/10 - 30A) 125 Volts AC or Less Edison Base Dual-Element, Time-Delay 3/10 4/10 1/2 6/10 8/10 1 AMPERE RATINGS TL (AMP) AMPERE RATINGS
|
Original
|
125VAC
3740-amp
3785-amp
edison
bussmann Fuse base
Edison Plug Fuse
TLO 61
|
PDF
|
Time-Delay
Abstract: fuses TLO 61 Edison Fuse
Text: General Purpose Fuses Plug Fuses 125 VAC • Time-Delay • 1/4 – 30 Amperes Edison-base Plug fuses TOO Fuses are dual-element time-delay Edison-base fuses designed for motor and motor branch circuit protection; also suitable for all general purpose
|
Original
|
|
PDF
|
E12112
Abstract: Edison Fuse SB98107 TL-20 TL-30 bussmann Fuse base
Text: Bussmann Plug Fuses Type TL Time-Delay, Edison Base 125 Volts, 15–30 Amps • Time-Delay Plug Fuse. • Will withstand typical motor starting surges. • Use in residential or light-duty circuits that contain electric motors. • Edison base size. • These fuses thread into fuse receptacles.
|
Original
|
125VAC
E12112)
TL-30
TL-15
TL-20
TL-25
SB98107
E12112
Edison Fuse
SB98107
TL-20
TL-30
bussmann Fuse base
|
PDF
|
TLO 61
Abstract: No abstract text available
Text: Plug Fuses 125 VAC • Fast-Acting or Time-Delay ■ 1/4 – 30 Amperes DESCRIPTION Edison-base plug fuses WOO, TOO, and TLO series have threaded metal shells and contacts similar to incandescent lamp bases. Fuseholders for Edison-base fuses have matching metal threads similar to standard light sockets.
|
Original
|
|
PDF
|
R25060-3CR
Abstract: r25030-2pr r2503 LENRK15 R250302CR R250301CR R25030-1PR IR-200ka R250303CR R250302SR
Text: Edison LENRK Class RK1 250Vac, 0.2 to 60A Dual-Element, Time-Delay Fuses Dimensions inches Catalog Symbol: LENRK Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current (8 seconds for 0-30A sizes) Current-Limiting Volts: 250Vac (or less)
|
Original
|
250Vac,
250Vac
200kA
300kA
E162363,
000AIR)
BU-SB07255
R25060-3CR
r25030-2pr
r2503
LENRK15
R250302CR
R250301CR
R25030-1PR
IR-200ka
R250303CR
R250302SR
|
PDF
|
R60030-1PR
Abstract: R60030-2PR R60060-3PR R60030-2SR R600303CR E162363 R60030-3CR R60030-1SR R60030-2CR R6003
Text: Edison LESRK Class RK1 600Vac, 0.25 to 60A Dual-Element, Time-Delay Fuses Dimensions inches Catalog Symbol: LESRK Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Current-Limiting Volts: 600Vac (or less) Amps: 0.25 to 60A IR: 200kA RMS Sym.
|
Original
|
600Vac,
600Vac
200kA
300kA
E162363,
000AIR)
BU-SB07255
R60030-1PR
R60030-2PR
R60060-3PR
R60030-2SR
R600303CR
E162363
R60030-3CR
R60030-1SR
R60030-2CR
R6003
|
PDF
|
E162363
Abstract: LCL700 51215 LCL1000 LCL1200 Edison Fuse LCL2000 lcl-25 LCL300 LCL500
Text: Edison LCL Class L 600Vac, 300 to 6000A Time-Delay Fuses Dimensions inches Catalog Symbol: LCL Time-Delay – 5 seconds (minimum) at 500% rated current Current-Limiting Volts: 600Vac (or less) Amps: 300 to 6000A IR: 200kA RMS Sym. Mounting: Bolt Mount
|
Original
|
600Vac,
600Vac
200kA
E162363,
BU-SB07255
E162363
LCL700
51215
LCL1000
LCL1200
Edison Fuse
LCL2000
lcl-25
LCL300
LCL500
|
PDF
|
JDL400
Abstract: JDL125 JDL450 JDL110 JDL100 JDL-250 JDL70 E162363 JDL80 JDL90
Text: Edison JDL Class J 600 Volt, 70 to 600A Dual-Element, Time-Delay Fuses Dimensions inches Catalog Symbol: JDL Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Current-Limiting Volts: 600Vac (or less) Amps: 70 to 600A IR: 200kA RMS Sym
|
Original
|
600Vac
200kA
300kA
E162363,
BU-SB07255
JDL400
JDL125
JDL450
JDL110
JDL100
JDL-250
JDL70
E162363
JDL80
JDL90
|
PDF
|
T32 fuse
Abstract: Fuses
Text: Bussmann Plug Fuses Type T Dual-Element, Time-Delay, Edison Base 125 Volts, 1–30 Amps • Heavy Duty Time-Delay Plug Fuse. • Use to protect critical motor circuits or motors that cycle on/off frequently. • An industrial/commerical grade product with exclusive dualelement construction.
|
Original
|
SB98107
T32 fuse
Fuses
|
PDF
|
bussmann
Abstract: HCTR0.3 HCTR10 HCTR25 HCTR12 HCTR1.6 HCTR2.5 HCTR1.25 HCTR2.25 BC6031S
Text: Edison HCTR Class CC 600Vac, 0.25 to 30A Time-Delay Fuses Dimensions inches Catalog Symbol: HCTR Time-Delay Volts: 600Vac (or less) Amps: 0.25 to 30A IR: 200kA RMS Sym. 10kAIC (12-30A) Agency Information: CE, UL Listed, Std. 248-4, Class CC, Guide JDDZ, File E162363, CSA Certified, Class CC CSA,
|
Original
|
600Vac,
600Vac
200kA
10kAIC
2-30A)
E162363,
HCTR10
HCTR12
HCTR15
HCTR20
bussmann
HCTR0.3
HCTR10
HCTR25
HCTR12
HCTR1.6
HCTR2.5
HCTR1.25
HCTR2.25
BC6031S
|
PDF
|
SA-1 FUSE
Abstract: No abstract text available
Text: Low Voltage, Branch Circuit Rated Fuses Plug fuses S and T Series Fustat Fuse Adapters Specifications Description: Dual-element, time-delay plug fuse. Dimensions: S — Rejection base T — Edison base Construction: S — Ceramic base with rejection threads
|
Original
|
125Vac
0-30A
E56412
E12112;
SA-10
SA-15
SA-30
SA-20
SA-1 FUSE
|
PDF
|
R602003CR
Abstract: R60200-3CR R602001CR LESRK300 LESRK225 R60100-3CR LESRK400 R606003CR R60200-1CR LESRK200
Text: Edison LESRK Class RK1 600Vac, 70 to 600A Dual-Element, Time-Delay Fuses Dimensions inches Catalog Symbol: LESRK Volts: 600Vac (or less) Amps: 70 to 600A IR: 200kA RMS Sym. (300kA self certified) 50kAIC Agency Information: UL Listed – Class R, Guide JDDZ, File
|
Original
|
600Vac,
600Vac
200kA
300kA
50kAIC
E162363,
BU-SB07255
R602003CR
R60200-3CR
R602001CR
LESRK300
LESRK225
R60100-3CR
LESRK400
R606003CR
R60200-1CR
LESRK200
|
PDF
|
BU 3150
Abstract: E162363 LENRK150 60 amp fuse Edison Fuse LENRK175 R25200-1CR 2664-R R252003CR LENRK500
Text: Edison LENRK Class RK1 250Vac, 70 to 600A Dual-Element Time-Delay Fuses Dimensions inches Catalog Symbol: LENRK Volts: 250Vac/125Vdc (or less) Amps: 70 to 600A IR: 200kA RMS Sym. 300kA RMS Sym. (self certified) Agency Information: CE, UL Listed – Class R, Guide
|
Original
|
250Vac,
250Vac/125Vdc
200kA
300kA
E162363,
BU-SB091106
BU 3150
E162363
LENRK150
60 amp fuse
Edison Fuse
LENRK175
R25200-1CR
2664-R
R252003CR
LENRK500
|
PDF
|
W-10
Abstract: W-12 W-15 W-20 W-25 W-30
Text: Bussmann Plug Fuses Type W Fast-Acting 125 Volts, 1/2–12 Amps • Fast-Acting Plug Fuse. • For lighting, heating or other circuits that do not contain electric motors. • Edison base size. • These fuses thread into fuse receptacles. • The General Purpose W fuse has no time-delay feature
|
Original
|
125Vac
E12112)
SB03177
W-10
W-12
W-15
W-20
W-25
W-30
|
PDF
|
|
E19180
Abstract: UL 248-14 e19180 ul E19180 buss agx 10 JDYX2 mda bussmann
Text: SMALL DIMENSION ELECTRONIC FUSES 1/4” x 1-1/4” Time-Delay Fuses 1/4” x 1” Fast-Acting Fuses MDL Time-Delay MDA Time-Delay AGX Fast-Acting Physical Size: Physical Size: 1/4” x 1-1/4” (6.3mm x 32mm) Construction: Ceramic Tube Nickel-plated Brass End Caps
|
Original
|
1/16-8A
E19180)
0000A
E19180
UL 248-14 e19180
ul E19180
buss agx 10
JDYX2
mda bussmann
|
PDF
|
AN 15525
Abstract: FR15 Edison 15525 Edison Fuse gsl15 GW25 TD15 thermal fuse GW20 Ferraz Shawmut
Text: PLUG FUSES SPECIAL PURPOSE PLUG fuses: G/GP/TD/GW/GTL/GT/GSL Ferraz Shawmut Plug Fuses are for industrial and residential applications. Standard non-time delay fuses are for receptacle and lighting circuits. Standard time delay fuses are for motor loads. For Canadian requirements, a type “P” fuse is used
|
Original
|
GTL15
GTL20
GTL25
GTL30
GSL15
GSL20
GSL25
GSL30
SAG3-2/10
SAG15
AN 15525
FR15 Edison
15525
Edison Fuse
gsl15
GW25
TD15
thermal fuse
GW20
Ferraz Shawmut
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Special Purpose Fuses Special Purpose Fuses American Fuses Plug Fuses PLUG FUSES: G/GP/TD/GW /GTL/GT/GSL Ferraz Shawmut Plug Fuses are for industrial and residential applications. Standard non-time delay fuses are for receptacle and lighting circuits. Standard time delay fuses are for motor loads.
|
Original
|
G214389
K215404
K212345
V212860
D213374
X213874
G214895
SAG3-2/10
SAG6-3/10
SAG15
|
PDF
|
spark gap by siemens
Abstract: ScansU9X25
Text: MAZDA 24BI TRIGATRON GENERAL A trlgatron is a spark gap which operates as a switch for discharging the delay line in pulse series modula tion. The instant of breadkown can he accurately con trolled by means of a triggering voltage applied to a third electrode. This triggering voltage distorts the
|
OCR Scan
|
|
PDF
|
DLS-10
Abstract: ediswan 10 DLS10 Edison time delay siemens Company
Text: \o < EDISW AN DLSIO VACUUM THERMAL DELAY SWITCH G ENERAL The D LS1 0 is a Vacuum Therm al Delay Switch w ith an A C switch rating of 6 amps at 250 volts, o r 200 m A at 1,000 volts. It has a heater rating of 1 -5 amps at 4 volts, and switch closure delay times of from 30 to 90 seconds, the switch
|
OCR Scan
|
DLS10
VH300/4
DLS-10
ediswan 10
Edison time delay
siemens Company
|
PDF
|
spark gap by siemens
Abstract: ScansU9X25
Text: MAZDA 2 4 . C .3 COLD CATHODE TRIGATRON GENERAL A trig atro n Is a spark gap which operates as a switch fo r discharging the delay lin e In pulse se rie s modulation. The instant of breakdown can be accurately controlled by means of a triggering voltage applied to a third electrod e. This
|
OCR Scan
|
|
PDF
|
Edison time delay
Abstract: VH238 VH330
Text: EDISWAN DLS23 VACUUM THERMAL DELAY SWITCH GENERAL The DLS23 is a Vacuum Thermal Delay Switch with an A C switch rating of 5 amps at 240 volts, or 100 mA at 1,000 volts. It has a heater rating of 1 amp at 2.5 volts and a switch closure delay time of from 30 to 90 seconds, the switch
|
OCR Scan
|
DLS23
DLS23
VH330/8,
VH238/8,
VH248/8
Edison time delay
VH238
VH330
|
PDF
|
Edison Fuse ECSR
Abstract: ECSR.1 E162363 ECNR.1 LCU1350 edis LESRK ECSR1 ECSR .1-600
Text: Product Catalog UL Fuses: Current Limiting Circuit Protection Table of Contents General Catalog Contents Page UL Fuses: Current Limiting Class RK5 Class RK1 Class RK Class L Class J Class T Class G Class CC Dual-Element, Time-Delay - ECNR/ECSR . . . . . . . . . . . . . . . . . . .1
|
Original
|
|
PDF
|
delay switch
Abstract: dls10 D.L.S. 15
Text: DLSI5 & DLSI6 VACUUM THERMAL DELAY SWITCHES general The DLS.15 and DLS.16 are designed for sim ilar applications as the DLS.10 but are Intended to f i l l the demand for a delay switch of reduced dimensions. RATING DLS.15 DLS.16 Filament Voltage volts Vf
|
OCR Scan
|
|
PDF
|
E162363 fuse
Abstract: E162363 HCTR.25 KLKR 10a ATQR Fuses
Text: HCLR FAST ACTING CLASS CC FUSES HCTR TIME DELAY CLASS CC FUSES Catalog Number HCLR .1 - 30A 600 Volts AC or Less Fast-Acting 0.1 0.125 0.2 0.25 0.3 AMPERE RATINGS 2.5 3 3.5 4 5 0.5 0.75 1 1.5 2 DIMENSIONS Ferrule (in) Amps .1 - 30 13/32 6 7 8 9 10 Catalog Number HCTR (.25 - 10A)
|
Original
|
600VAC
E162363 fuse
E162363
HCTR.25
KLKR 10a
ATQR Fuses
|
PDF
|