Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    EPBAP74 Search Results

    SF Impression Pixel

    EPBAP74 Price and Stock

    Marathon Special Products EPBAP74

    Enclosed Power Block; Rated Current:335A; Rated Voltage:600V; No. Of Poles:10 Pole; Line Side Connections Per Pole:1; Line Side Connection Method:Screw; Line Side Wire Size Max:00Awg; Load Side Connection Method:Screw Rohs Compliant: Yes |Marathon Special Products EPBAP74
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Newark EPBAP74 Bulk 12
    • 1 -
    • 10 $190.48
    • 100 $179.35
    • 1000 $179.35
    • 10000 $179.35
    Buy Now
    Onlinecomponents.com EPBAP74 36
    • 1 $226.17
    • 10 $194.13
    • 100 $182.73
    • 1000 $182.73
    • 10000 $182.73
    Buy Now
    Master Electronics EPBAP74 36
    • 1 $226.17
    • 10 $194.13
    • 100 $182.73
    • 1000 $182.73
    • 10000 $182.73
    Buy Now

    Marathon Special Products EPBAP74 (ALTERNATE: 784337 55550)

    Power Terminal Block Panel Mount Thermoplastic Insulator 335A 600V 1 Pole | Marathon Special Products EPBAP74
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    RS EPBAP74 (ALTERNATE: 784337 55550) Bulk 66 26 Weeks 1
    • 1 $198.1
    • 10 $182.25
    • 100 $182.25
    • 1000 $182.25
    • 10000 $182.25
    Buy Now

    EPBAP74 Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    d 2499

    Abstract: E62806 dc plug
    Text: Product Data Sheet EPBAP74 Enclosed Distribution Power Block 335 Amps, 600V UL/CSA 1,000V AC/DC CE IEC 60947-7-1 Wire Range: Line side: (1) 400kcmil - #6 AWG (185 – 16 mm²) and (1) 2/0 - #14 (70 – 2.5 mm²) Load Side: (8) #2 - 16 AWG (35 – 2.5 mm²)


    Original
    EPBAP74 400kcmil IP-20 8367A23 8367A24 8367A26 d 2499 E62806 dc plug PDF

    145X282

    Abstract: No abstract text available
    Text: Power Distribution Blocks with SCCR and Feeder Spacing Short-Circuit Current Ratings and Feeder Spacing SCCR Information: The requirements of the National Electric Code NEC and UL508A now require many electrical panels to carry a Short Circuit Current Rating


    Original
    UL508A 350MCM-6 145X282 PDF

    1443557

    Abstract: JGL36250 JJL36250 1432555 1453586 JLL36250 1453552 1433553 1413400 FPB23570CH
    Text: 13300 Van Camp Road P.O. Box 468 Bowling Green, OH 43402 Standard Power Distribution Blocks With High Short-Circuit Current Ratings Marathon offers 600 Volt Power Distribution Blocks with high SCCR’s in response to new 2005 NEC and UL508A marking requirements


    Original
    UL508A 1443557 JGL36250 JJL36250 1432555 1453586 JLL36250 1453552 1433553 1413400 FPB23570CH PDF