Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ESSEX SS9 5LS Search Results

    ESSEX SS9 5LS Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    full load current of a 11Kw motor

    Abstract: DuoSoft.N15 MTE power control relay ac power control applications 400v 16a DuoSoft dc motor soft start AC Motor soft start 3 ph AC Motor speed and soft start mte overload AC Motor speed and soft start
    Text: Technical Specification I 2 DuoSoft.N7 DuoSoft.N11 DuoSoft.N15 Three-phase Soft Starters DuoSoft.N7 DuoSoft.N11 & DuoSoft.N15 are compact low cost soft starters for three-phase motors up to 7.5, 11 & 15 kW respectively. They overcome the disadvantages of the usual DOL direct-on-line


    Original
    PDF 012132/2E/1098 full load current of a 11Kw motor DuoSoft.N15 MTE power control relay ac power control applications 400v 16a DuoSoft dc motor soft start AC Motor soft start 3 ph AC Motor speed and soft start mte overload AC Motor speed and soft start

    wiring 3 phase dol starter with emergency stop

    Abstract: wiring diagram dol motor starter 55Kw motor wiring diagram dol starter mte powerbrake 5.5KW motor wiring diagram 37Kw motor 15KW motor wiring diagram 110v dc motor control circuit 400v 3KW motor circuit
    Text: Technical Specification English Issue 4 Panel hardware: Fault indicator lamp amber START button (I) STOP/RESET button (O) (overload reset) Powerbrake PBPS Range DC Injection Production Brakes Powerbrake PBPS is a range of self-contained D.C. Injection


    Original
    PDF 012262/4E/502 wiring 3 phase dol starter with emergency stop wiring diagram dol motor starter 55Kw motor wiring diagram dol starter mte powerbrake 5.5KW motor wiring diagram 37Kw motor 15KW motor wiring diagram 110v dc motor control circuit 400v 3KW motor circuit

    5.5KW motor FUSE RATING

    Abstract: wiring diagram dol motor starter 5.5KW motor wiring diagram wiring diagram dol starter 7.5KW motor resistance DOL starter wiring diagram motor DOL wiring diagram motor 37KW motor wiring diagram dol motor starter wiring diagram 55Kw motor
    Text: Technical Specification English Powerbrake Issue 3 PBC Range DC Injection Critical Brakes Panel hardware: Fault indicator lamp amber RESET button Powerbrake PBC is a range of self-contained D.C. Injection Critical


    Original
    PDF 012261/3E/302 5.5KW motor FUSE RATING wiring diagram dol motor starter 5.5KW motor wiring diagram wiring diagram dol starter 7.5KW motor resistance DOL starter wiring diagram motor DOL wiring diagram motor 37KW motor wiring diagram dol motor starter wiring diagram 55Kw motor

    wiring diagram dol motor starter

    Abstract: wiring 3 phase dol starter with overload diagram wiring diagram dol starter DOL wiring diagram motor DOL starter wiring diagram wiring start dol DOL starter wiring diagram motor dol motor starter wiring diagram wiring diagram start dol three-phase 3kw ac motor speed control circuit diagram
    Text: Technical Specification English Powerbrake PBP Range DC Injection Production Brakes for existing DOL Starters Powerbrake PBP is a range of self-contained D.C. Injection Production Brakes for use with an existing DOL Starter. It is suitable for 400V three-phase motors from 3.0 to 75 kW.


    Original
    PDF 012263/3E/302 wiring diagram dol motor starter wiring 3 phase dol starter with overload diagram wiring diagram dol starter DOL wiring diagram motor DOL starter wiring diagram wiring start dol DOL starter wiring diagram motor dol motor starter wiring diagram wiring diagram start dol three-phase 3kw ac motor speed control circuit diagram

    magnetic Contactor wiring diagrams

    Abstract: PLUGGING BRAKING DIAGRAM PLUGGING OF INDUCTION MOTOR automatic brake failure indicator AC drives regenerative braking circuits mte thermal overload relay contactor wiring diagram with timer brake failure indicator 5.5KW induction motor wiring diagram dol motor starter
    Text: Technical Specification English Issue 2 Powerbrake Terminal functions DCB5A D.C. Injection Brake Unit A1 A2 N.B. The DCB5A is fully interchangeable with the former DCB5. The DCB5 was identified by a light grey enclosure with a black lid. The DCB5A is all light grey.


    Original
    PDF

    BS4999

    Abstract: mte overload mte thermal overload relay MTE Entrelec automatic brake failure indicator brake failure indicator CETA164 CETA324 DCPM022 DCPM045
    Text: Technical Specification English } P3 P4 } DCPM heatsink temperature n.c. contact, opening when temperature is high P5 Thyristor fail detect (link to P3 to disable e.g. with old DCPM) P1 P2 Powerbrake DCBUA / DCPM D.C. Injection Brake System Issue 2 Thermistor connections


    Original
    PDF

    BU 448

    Abstract: lexan IR ESSEX ss9 5ls mte overload T30-3-E BU 647 IR Light infrared led T306EQ T30RW3R ss9 5ls
    Text: Photoelectric Sensors T30 series DC operation Excess gain curve: Excess gain in relation to the distance £ o 8 & Í - Retro-reflective £ Si # c <Z j? O with polarising filter 100 6 6 6 6 0.01 m m m m red red red red pnp pnp npn npn cable connector cable


    OCR Scan
    PDF T30-SP6-LP T30-SP6-LP-Q T30-SN6-LP T30-SN6-LP-Q FF400 T30-SP6- FF200 FF200-Q BU 448 lexan IR ESSEX ss9 5ls mte overload T30-3-E BU 647 IR Light infrared led T306EQ T30RW3R ss9 5ls

    ESSEX ss9 5ls

    Abstract: CETA
    Text: O&ÜE Installation - CETA auxiliary contacts When fitting to CETA25/32 contactors depress bridge slightly when sliding contact block into position. lock into position. Ratings: auxiliary contacts Maximum number of auxiliary contacts = 4 10A Ith max_


    OCR Scan
    PDF CETA25/32 ESSEX ss9 5ls CETA

    C947

    Abstract: HRC Fuse BASE ESSEX ss9 5ls
    Text: C€ E-Pack Installation Instructions Starters Type EXS2-DI Issue 6 Installation ie c 947 4-1 - Ratings 1. Remove cover from starter by releasing catches with a screwdriver. Direct-On-Line up to 15kW 415V max. 2. Check operating coil voltage and frequency.


    OCR Scan
    PDF

    Overload MTE

    Abstract: mte overload IEC 947-4-1 MAX072
    Text: E-Pack Installation Instructions Starters Type EXS1-D up to 15kW Issue 4 C€ IEC 947-4-1 METAL ENCLOSURE Installation Ratings 1. Remove cover from starter by releasing catches with a screwdriver, i Insert screwdriver into slot to release catch 2. Check operating coil voltage and


    OCR Scan
    PDF 15V/3PH 40V/1PH Overload MTE mte overload IEC 947-4-1 MAX072

    C947

    Abstract: C-947
    Text: C€ E-Pack Installation Instructions Starters Type EXS2-DR Issue 6 Installation - Ratings 1. Remove cover by releasing catches with a screwdriver. 2. Check operating coil voltage and frequency. 3. Remove appropriate top/bottom conduit knockouts. 4. Mount base on a vertical surface using top


    OCR Scan
    PDF 32EXS2-DR C947 C-947

    mte thermal overload relay

    Abstract: mte overload recommended star-delta control circuit Overload MTE mte relay MTE Contactor ESSEX ss9 5ls neutral links mte coil fuse/mte thermal overload relay
    Text: ce E-Pack installation Instructions Starters Type EXS2-S and EXS2-SI Issue 1 Installation ie c 947 4-1 - Ratings 1. Remove cover by releasing catches with a screwdriver. Star-Delta 22kW 415V max. Coil voltages 50Hz 240V 415V Recommended Approximate motor rating max. fuse


    OCR Scan
    PDF

    ESSEX Contactor

    Abstract: 3 phase, 415v and 37 kw motor mte contactor coil 32EXS0-D mte overload MAX072 Overload MTE mte contactor 3 phase, 415v and 55 kw motor 3 phase, 415v and 12 kw motor
    Text: C€ Installation Instructions Starters Type: EXSO-D Issue 10 Im STB W^fPACK I EC 947-4-1 Ratings Full load current min. max. Approximate motor ratir g 415V/3PH 240V/1PH AC3 AC3 kW hp kW hp Recommended max. fuse size for short circuit protection A O rderreferences


    OCR Scan
    PDF 32EXS0-D 15V/3PH 40V/1PH ESSEX Contactor 3 phase, 415v and 37 kw motor mte contactor coil mte overload MAX072 Overload MTE mte contactor 3 phase, 415v and 55 kw motor 3 phase, 415v and 12 kw motor

    ESSEX Contactor

    Abstract: HL25-240D MTE Contactor
    Text: C€ E-Pack Installation Instructions Enclosed Contactors issue 8 Features IEC 947-4-1 Typical Circuit Connections An extensive range of contactors, in ratings up to 200 Am ps, for switching three-phase heating and lighting loads. Available with d.c. coil and rectifier for


    OCR Scan
    PDF 1x10m 1x35m HL100 HL180 HL200 ESSEX Contactor HL25-240D MTE Contactor

    3 phase motor auto starter circuit diagram

    Abstract: wiring diagram single phase dol starter AT66A single phase DOL starter wiring soft starter wiring integral starter is 2000 diagram dol starter 3 phase motor auto DOL starter circuit diagram wiring diagram dol starter
    Text: C€ Technical Specification PAIR Motor Protection Relay Response characteristics Overload trip characteristic PAIR is designed for use with motors which require protection against both overtoad and underload conditions. Pump motors, for example, require normal overload protection, but the pump itself can be damaged


    OCR Scan
    PDF

    wiring diagram slip ring motor resistance starter

    Abstract: fuse 9 BJE 69 testing soft starter 37 MTE powersoft 37 MTE soft starter wiring diagram to hold contactor with NO, NC AC 240V Motor Speed Controller wiring diagram slip ring motor 415V AC slip ring motor characteristics curve 3 phase motor soft starter diagram
    Text: POWERSOFT MN SERIES ELECTRONIC MOTOR CONTROLLERS 4kW to 37kW TECHNICAL MANUAL 1E February 1997 2 Contents 1. Introduction 1. Introduction Page 2 2. T echnical sp ecification Page 3 3. Principles of o peration Page 3 4. Selection guide Page 5 PowerSoft MN Series is a low cost soft starter and controller for 3phase m otors up to 37kW. Each phase of the m otor is fully controlled


    OCR Scan
    PDF