Tyco faston insulated crimp
Abstract: 3-520133-2 3-521191-2 4-520448-2 520447 e907 faston connectors ul 310
Text: FASTON Terminals Insulated and Uninsulated Ultra-Fast Fully Insulated FASTON Receptacles and Tabs Product Facts • One-piece Fully Insulated Premier Line FASTON Receptacle crimp helps prevent shock and short hazards ■ Designed for correct lead-in of tab
|
Original
|
|
PDF
|
faston connectors ul 310
Abstract: No abstract text available
Text: FASTON Terminals Insulated and Uninsulated Page Head_12 Ultra-Fast FullyHel. Insulated Con. Bold FASTON (Continued)_9pt Receptacles Helvetica and Lt Condensed Tabs Product Facts n One-piece Fully Insulated Premier Line FASTON Receptacle crimp helps prevent shock and short
|
Original
|
|
PDF
|
File No. E-66717
Abstract: Faston E66717 UL-310
Text: FASTON Terminals Insulated and Uninsulated Ultra-Fast Fully Insulated FASTON Receptacles and Tabs Product Facts • One-piece Fully Insulated Premier Line FASTON Receptacle crimp helps prevent shock and short hazards ■ Designed for correct lead-in of tab
|
Original
|
|
PDF
|
UL-310
Abstract: E9071003 187 series faston tab 521087-1 2-520183-2 2-520080-2
Text: FASTON Terminals Insulated and Uninsulated Ultra-Fast Fully Insulated FASTON Receptacles and Tabs Product Facts • One-piece Fully Insulated Premier Line FASTON Receptacle crimp helps prevent shock and short hazards ■ Designed for correct lead-in of tab
|
Original
|
|
PDF
|
E9071003
Abstract: UL-310 696369-1 calibration of crimping tool 3-520132-2 calibration for 565435-5 LR-7189
Text: FASTON Terminals Insulated and Uninsulated Ultra-Fast Fully Insulated FASTON Receptacles and Tabs Product Facts • One-piece Fully Insulated Premier Line FASTON Receptacle crimp helps prevent shock and short hazards ■ Designed for correct lead-in of tab
|
Original
|
|
PDF
|
114-2079
Abstract: faston flag receptacles crimp height 2082 tyco 408-9640 565435-5 114-2036 408-7424 49710 Tyco faston 567768
Text: Application Specification 114-2079 FASTON* Flag Receptacles with F" -Crimp Feature NOTE i 27 OCT 08 Rev E All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|
faston flag receptacles crimp height
Abstract: DC21982 1725950-3 408-7424 faston crimp height 458000 2082 tyco faston 250 crimp height 49710 Tyco 114-2078
Text: Application Specification FASTON* F-" Crimp Center-Strip Flag Receptacles NOTE i 114-2126 05 NOV 08 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|
faston flag receptacles crimp height
Abstract: 466502-2 AMPOMATOR CLS IV 408-7424 408-9640 7432 90165-1 49710 PIGGYBACK 408-8040
Text: Application Specification 114-2082 FASTON* Piggyback Receptacles NOTE i 28 MAR 08 Rev F All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|
114-2036
Abstract: faston flag receptacles crimp height UL-310 114-2079 408-7424 408-7432 7432 6.35x0.8 Application# 687892-3 B amp cls iiiG
Text: Application Specification 114-2036 FASTON* Straight Receptacles with F-" Crimp Feature NOTE i 06 AUG 08 Rev D All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|
tyco crimp height chart
Abstract: 408-7424 59824-1 solder crimp height faston crimp height general maintenance for applicators 58433-3 408-9640 59824-1 Tyco Amp 7432 Tyco 408-7424
Text: Application Specification 114-13076 PIDG* FASTON* Tabs and Fully-Insulated Receptacles NOTE 09 JAN 08 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and _ inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|
Tyco 408-5842
Abstract: 408-9640 DC2-1982 LR7189 faston flag receptacles Tyco faston insulated crimp faston flag receptacles crimp height 4-0827 635X0
Text: Application Specification Ultra-Pod FASTON* 114-2124 Fully Insulated Receptacles and Tabs NOTE i 17 DEC 08 Rev N All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|
408-7424
Abstract: UL-310 pull force requirements 408-7432 instructions 8082 Tyco 408-7424 faston crimp height tensile strength crimping pull test 567200-2 8082 codes ELT 406
Text: Application Specification 114- 13047 Budget FASTON* Receptacle Contacts 24 NOV 09 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
|
Original
|
|
PDF
|
466779
Abstract: 408-6976 Tyco AMP document 408-6976 58080-3 Tyco faston insulated proper hand crimping procedure 408-9902 B 722 P UL-310 Tyco (AMP) document 408-6976 AMP crimper 69710-1 408-2095
Text: Application Specification Ultra- Fast Series 110, 125, 187, 205, and 250 Fully- Insulated FASTON* Terminals NOTE i 114- 2123 02 OCT 09 Rev F All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and
|
Original
|
|
PDF
|
din 42802
Abstract: iec 60794 CRIMPING TOOL FOR 170324-2 59824-1 Tyco Amp raychem catalog termination kit and splicing kit 42770-2 AMP multifitting MKII Machine IEC 62056-21 RAST-5-Standard maintenance manual 565435-5
Text: FASTON Terminals Insulated and Uninsulated FASTON Terminals Insulated and Uninsulated Tyco Electronics Corporation Harrisburg, Pennsylvania www.tycoelectronics.com 82004 Revised 07-2006 5M SK FP RoHS Ready FASTON Terminals (Insulated and Uninsulated Page Head_12
|
Original
|
|
PDF
|
|
bellmouth standard
Abstract: 408-9640 bellmouth faston crimp height crimp quality monitor faston 250 crimp height
Text: Application Specification 114-2070 AMPLIVAR* FASTON* Tab Contacts NOTE i 08 DEC 08 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|
AMP Faston flag connector
Abstract: faston flag receptacles with tab-lok crimp 114-2079 LR49710 114-2078 2082 tyco 408-7424 FASTON connector faston flag receptacles crimp height 1725950-3
Text: Application Specification 114-2032 FASTON* Reversible Flag Receptacles 30 JUL 08 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|
354500-1
Abstract: 408-7432 tyco pull force chart tyco crimp height chart 114-2025 Tyco faston LR7189 408-7424 46633 faston 250 crimp height
Text: Application Specification 114- 2025 FASTIN- FASTON* Tabs, Receptacles, and Housings NOTE i 13 AUG 09 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
|
Original
|
|
PDF
|
567200-3
Abstract: applicator 567200-3 696363-1
Text: FASTON Terminals Insulated and Uninsulated Page Head_12 Ultra-Pod FullyHel. Insulated Con. Bold FASTON (Continued)_9pt Receptacles Helvetica and Lt Tabs Condensed Ultra-Pod Fully Insulated FASTON Receptacles and Tabs Product Facts n Reduced insertion force
|
Original
|
|
PDF
|
AMPOMATOR CLS IV
Abstract: faston flag receptacles crimp height 59824-1 Tyco Amp hand tool faston flag receptacles crimp height smema AMP UK 45 faston 110 board mount tabs Crimping micro applicator crimp force smema control
Text: FASTON Terminals Insulated and Uninsulated Page Head_12 Application Tooling Hel. Con. Bold (Continued)_9pt Helvetica Lt Condensed AMP-O-LECTRIC Model “G” Termination Machines A totally new design of our most popular machine for bench-top operation. It features a quiet and
|
Original
|
|
PDF
|
PIDG Faston 6,3 x 0,8
Abstract: DIN 46249, crimping E9071003 cei 760 114-2002 DIN 46249 TERMINALS 108-20019 626064-0 DIN 46346 TYCO 539743-2 CRIMP TOOL
Text: Products for Industrial Applications Search By TYCO Part Number Pages 1964-2005 AMP FASTON Terminals Insulated and Uninsulated Catalogue 1654741 FASTON Terminals (Insulated and Uninsulated) Revised 7-07 FASTON Receptacles FASTON Receptacles Product Facts
|
Original
|
|
PDF
|
567200-2
Abstract: 59824-1 59828-1 applicator 567200-3 567200-3 59824-1 Tyco Amp 640911-1 E66717 LR7189 MIL-T-10727
Text: FASTON Terminals Insulated and Uninsulated PIDG FASTON Receptacles and Tabs Product Facts • Pre-insulated terminal designed for complete and uniformed reliability in the most difficult circuit environment ■ Consists of an unplated or tin plated brass body or a
|
Original
|
|
PDF
|
565435-5
Abstract: No abstract text available
Text: FASTON Terminals Insulated and Uninsulated PIDG FASTON Receptacles and Tabs Product Facts • Pre-insulated terminal designed for complete and uniform reliability in the most difficult circuit environment ■ Consists of an unplated or tin plated brass body or a
|
Original
|
perf00
565435-5
|
PDF
|
Tyco 114-2078
Abstract: faston flag receptacles crimp height tyco crimp height specification faston flag receptacles with tab-lok crimp AMPOMATOR CLS IV 47417 TE 250 for crimping 114-2078 LR7189 bellmouth standard
Text: Application Specification 114-2078 FASTON* Flag Receptacles with Tab-Lok Feature NOTE i 06 AUG 08 Rev M All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|
amp 408-1559
Abstract: 59824-1 Tyco Amp 818380-1 59824-1, 408-7424 59824-1 solder crimp height 567200-2 187 series faston tab bellmouth 408-7278 E-66717
Text: ti/ca/Electronics * A p p lica tio n S p e cification Pre-Insulated Diamond Grip PIDG* FASTON* Receptacle Contacts 114-1002 02 a u g 02 Rev c A ll numericai values are in metric units [with U.S. customary units in brackets]. Dimensions are in mliiimeters [and
|
OCR Scan
|
|
PDF
|