blown fuse indicator
Abstract: datasheet of blown fuse indicator 0430500000 ask 1 ld 0225760000 failure rate fuse 0222760000 1653350001 0225560000
Text: Circuit Protection Terminals ASK 1 LD ASK 1 Warning: • Install AP partition after last fuse terminal. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which speed identification of fuse failures and reduce costly
|
Original
|
PDF
|
|
0430700000
Abstract: 0430500000 Fuse 0430900000 9503330000 04-3070-0000 043050
Text: Circuit Protection Terminals KDKS 1 with power on indication combi-foot Warning: • Install AP partition after last ASK 1 or KDKS 1. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which speed identification of fuse failures
|
Original
|
PDF
|
|
101130000
Abstract: UL-94-V0 wemid weidmuller fuse DIN 2510 101230000 043060
Text: Datasheet W S I F u s e Te r m i n a l s w i t h L o w Current Status Indication Weidmuller offers versions of the WSI fuse terminals with low current blown fuse indication BFI . The BFI circuit is located in parallel with the fuse so that a current goes through the indicator only when the
|
Original
|
PDF
|
5x20mm
94-V0
101130000
UL-94-V0 wemid
weidmuller fuse
DIN 2510
101230000
043060
|
Untitled
Abstract: No abstract text available
Text: Datasheet W S I F u s e Te r m i n a l s w i t h L o w Current Status Indication Weidmuller offers versions of the WSI fuse terminals with low current blown fuse indication BFI . The BFI circuit is located in parallel with the fuse so that a current goes through the indicator only when the
|
Original
|
PDF
|
5x20mm
|
1050000000
Abstract: WSI-6
Text: Datasheet W S I F u s e Te r m i n a l s w i t h L o w C u r re n t S t a t u s I n d i c a t i o n Weidmuller offers versions of the WSI fuse terminals with low current blown fuse indication BFI . The BFI circuit is located in parallel with the fuse so that a current goes through the indicator only when
|
Original
|
PDF
|
5x20mm
94-V0
60-150VAC/DC
250VAC/110VDC
10-36VAC/DC
30-70VAC/DC
5/09-LIT0914
1050000000
WSI-6
|
UL-94-V0 wemid
Abstract: 0430700000 1012300001
Text: Datasheet W S I F u s e Te r m i n a l s w i t h L o w C u r re n t S t a t u s I n d i c a t i o n Weidmuller offers versions of the WSI fuse terminals with low current blown fuse indication BFI . The BFI circuit is located in parallel with the fuse so that a current goes through the indicator only when
|
Original
|
PDF
|
5x20mm
94-V0
10-36VAC/DC
30-70VAC/DC
60-150VAC/DC
250VAC/110VDC
5/10-LIT0914
UL-94-V0 wemid
0430700000
1012300001
|
weidmuller fuse
Abstract: 043060000
Text: Datasheet Fuse terminal 5 x 20 mm and 1 1/4" x 1/4" with screw connection technology clamping yoke WSI 4, 5 x 20 mm WSI 4/2, 1 1/4" x 1/4" NEW The new WSI 4 and 4/2 fuse terminal series offers you a compact solution for implementing short-circuit and overload protection utilizing
|
Original
|
PDF
|
10-pole
5X100
5M-LIT0607
weidmuller fuse
043060000
|
EW35
Abstract: weidmuller fuse Weidmuller TS35x7.5 02958 CLASS J blown fuse indicator GZ Series TS32x15
Text: Datasheet Fuse terminal 5 x 20 mm and 1 1/4" x 1/4" with screw connection technology clamping yoke WSI 4, 5 x 20 mm WSI 4/2, 1 1/4" x 1/4" The new WSI 4 and 4/2 fuse terminal series offers you a compact solution for implementing short-circuit and overload protection utilizing
|
Original
|
PDF
|
10-pole
5X100
5M-LIT0607
EW35
weidmuller fuse
Weidmuller TS35x7.5
02958
CLASS J blown fuse indicator
GZ Series
TS32x15
|
0225820000
Abstract: G-FUSE
Text: SAKS 1 SAKS 1 Neon Lamp LED Single Level 5 x 20 mm Fuse Single Level 5 x 20 mm Fuse Terminal Block Selection Data Available Options Version Beige Wemid Beige PA KrG 24 VDC 24 VDC Hinge + 24 VDC Hinge – 24 VAC 24 VAC/DC 48 VDC 48 VAC 48 VAC/DC 40-50 VAC 40-50 VDC
|
Original
|
PDF
|
|
Fuse 250V 2A G20
Abstract: weidmuller fuse 1.6A fuse 5AF10
Text: Fuse terminals 10 mm2 KSKM 1 10 mm2 KSKM 2 5 x 20 1 x 1/4 13 x 69 x 63 6.3 / 16 0.33 . 16 13 x 69 x 63 13 / 16 0.33 . 16 TS 32 / PA TS 32 / PA When using ATEX certified components in hazardous area applications the installation instructions and the rated data for
|
Original
|
PDF
|
20/1A/F
20/2A/F
Fuse 250V 2A G20
weidmuller fuse
1.6A fuse
5AF10
|
Weidmuller TS35x7.5
Abstract: Fuse 0430900000 0430700000 04-4630 043050 5AF10
Text: Fuse terminals 10 mm2 KSKM 1 10 mm2 KSKM 2 5 x 20 1 x 1/4 13 x 69 x 63 6.3 / 16 0.33 . 16 13 x 69 x 63 13 / 16 0.33 . 16 TS 35 / PA TS 35 / PA When using ATEX certified components in hazardous area ap- A plications the installation instructions and the rated data for
|
Original
|
PDF
|
TS35x7
SBL/2489
20/2A/F
20/1A/F
Weidmuller TS35x7.5
Fuse 0430900000
0430700000
04-4630
043050
5AF10
|
10x38
Abstract: S508A 1609820000
Text: I n t ro d u c t i o n — F u s e Te r m i n a l B l o c k s 508A 200kA WSI 25CC WSI 4, 5 x 20 mm WSI 25 10x38 WSI 4/2, 1 1/4" x 1/4" WSI 25CC/LED Fuse terminal 5 x 20 mm and 1 1/4" x 1/4" with screw connection technology clamping yoke WSI 25 10x38/LED
|
Original
|
PDF
|
200kA
10x38
25CC/LED
10x38/LED
10-pole
5X100
S508A
1609820000
|
Untitled
Abstract: No abstract text available
Text: D a t a S h e e t • Te r m i n a l s Fuse terminal 5 x 20 mm with screw connection technology clamping yoke WSI 4 NEW Small and compact! When utilising the WSI 4 measuring just 8 x 50.7 x 39.4 mm the shortc i rc u i t a n d o v e r l o a d p ro t e c t i o n i n
|
Original
|
PDF
|
|
1609900000
Abstract: Fuse 0430900000
Text: D a t a S h e e t • Te r m i n a l s Fuse terminals ZSI 6-2 2 x 2,5 G G ZSI 2.5 2 x 2AN G G NEW 20 25 20 25 Particularly suitable for ship building, u s e s s u r g e p ro o f c a b l e s t o g e t h e r w i t h G 5 x 20 and G 5 x 25 fuses, which a re i n g e n e r a l u s e w o r l d - w i d e , e a c h
|
Original
|
PDF
|
|
|
ask 1 ld
Abstract: No abstract text available
Text: Circuit Protection Terminals ASK 1 LD ASK 1 W arning: • Install AP partition after last fuse terminal. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which speed identification of fuse failures and reduce costly
|
OCR Scan
|
PDF
|
|
9139310000
Abstract: ZBE 1016 9139130000
Text: ACCESSORIES 182 W eidm iiller ! • SIHA fuse holder The SIHA fuse holder turns your disconnect terminal into a fuse terminal within seconds. Just remove the disconnect lever, and plug-in the fuse connector - ready! Terminal markers As one of the leading manufacturers
|
OCR Scan
|
PDF
|
|
Fuse T 2.5
Abstract: No abstract text available
Text: Circuit Protection Terminals KDKS 1/PE with blown fuse indicator BFI and circuit disconnect Warning: • Install AP partition after last ASK 1 or KDKS 1. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which
|
OCR Scan
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Circuit Protection Terminals ZSI 2.5 with blown fuse indicator Warning: for AC or DC voltage • Install ZAP TNHE fuse cover and ZAP end plate after last ZSI 2.5. W . • Disconnect power before replacing the fuse. \ j- Fuse terminals are available it . tsrfefD ISM .
|
OCR Scan
|
PDF
|
|
9802730000
Abstract: No abstract text available
Text: KDKS 1 Circuit Protection Terminals KDKS 1 KDKS 1 PE Combi-foot Warning: • Install AP partition after last or KDKS 1. • Disconnect power before replacing the fuse. . Fuse terminals are available with LED blown fuse indicators, which speed identification of fuse failures
|
OCR Scan
|
PDF
|
|
Fuse 0430900000
Abstract: thermal fuse vdc 0474560000
Text: Circuit Protection Terminals ASK 1 combi-foot with blown fuse indicator BFI Warning: and circuit disconnect • Install AP partition after last ASK 1 or KDKS 1. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which
|
OCR Scan
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Circuit Protection Terminals ZDL 2.5/SI/DU/PE ZTR 2.5/SI ZDL 2.5/SI/DU Warning: 1 •Disconnect power before % ii B replacing the fuse. Fuse terminals are available with LED blown fuse indica • tors, which speed identifica tion of fuse failures and reduce costly down time. The
|
OCR Scan
|
PDF
|
|
2SD28
Abstract: No abstract text available
Text: Circuit Protection Terminals WSI 6 with blown fuse indicator Warning: for AC or DC voltage • Install WAP partition after last WSI 6. • Disconnect power before replacing the fuse. ï Fuse terminals are available with it i n *“ 1,1 ï • r I' LED blown fuse indicators, which
|
OCR Scan
|
PDF
|
|
043060000
Abstract: 0431100000
Text: Circuit Protection Terminals KDKS 1 with power on indication with blown fuse indicator BFI and circuit disconnect Warning: • Install AP partition after last ASK 1 or KDKS 1. • Disconnect power before replacing the fuse. Fuse terminals are available with
|
OCR Scan
|
PDF
|
fu31/2
043060000
0431100000
|
Untitled
Abstract: No abstract text available
Text: SAKS 1 SAKS 1 Neon Lamp LED Single Level 5 x 20 mm Fuse Single Level 5 x 20 mm Fuse Terminal Block Selection Data Available Options Version t_r Cj i_r Beige Wemid Beige PA KrG 24 VDC 0371420000 0225820000 24 VDC Hinge + 24 VDC Hinge 24 VAC 1111320000 24 VAC/DC
|
OCR Scan
|
PDF
|
|