Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    FUSE ABB Search Results

    FUSE ABB Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCKE800NA Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE800NL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE812NA Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE812NL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, Fixed Over Voltage Clamp, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE712BNL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 13.2 V, 3.65 A, Latch, Adjustable Over Voltage Protection, WSON10 Visit Toshiba Electronic Devices & Storage Corporation

    FUSE ABB Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    Untitled

    Abstract: No abstract text available
    Text: Technical Datasheet 1SNK162045D0201 Catalogue Page 1SNK162022S0201 ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator - Protect your circuits with 5x20 fuse terminal blocks compliant with IEC 60947-7-3 standard fuse not supplied


    Original
    1SNK162045D0201 1SNK162022S0201 1SNK162091V0014 1SNK500181F0000 1SNC500511 F0000 F-69685 1SNK162045D0201 PDF

    D0201

    Abstract: A1101 C1002 S0201
    Text: Technical Datasheet 1SNK 161 037 D0201 10/12/09 Catalogue Page 1SNK 161 037 S0201 ZS4-SF-R Screw Clamp Terminal Block Fuse -P  rotect your circuits with 5x20 fuse terminal blocks compliant with IEC 60947-7-3 standard fuse not supplied with the terminal blocks ,


    Original
    D0201 S0201 F-69685 1SNK161037D0201 D0201 A1101 C1002 S0201 PDF

    IEC 60947-7-1 COLOR

    Abstract: A1101 C1002 S0201 Terminal Blocks 60947-7-1 ABB/IEC 60947-7-1
    Text: Technical Datasheet 1SNK 161 005 D0201 21/01/10 Catalogue Page 1SNK 161 005 S0201 ZS4-SF Screw Clamp Terminal Block Fuse -P  rotect your circuits with 5x20 fuse terminal blocks compliant with IEC 60947-7-3 standard fuse not supplied with the terminal blocks ,


    Original
    D0201 S0201 R0000 F-69685 1SNK161005D0201 IEC 60947-7-1 COLOR A1101 C1002 S0201 Terminal Blocks 60947-7-1 ABB/IEC 60947-7-1 PDF

    IEC 60947-1

    Abstract: A1101 C1002 S0201
    Text: Technical Datasheet 1SNK 161 038 D0201 21/01/10 Catalogue Page 1SNK 161 038 S0201 ZS4-SF-T Screw Clamp Terminal Block Fuse -P  rotect your circuits with 5x20 Fuse terminal blocks compliant with IEC 60947-7-3 standard fuse not supplied with the terminal blocks ,


    Original
    D0201 S0201 F-69685 1SNK161038D0201 IEC 60947-1 A1101 C1002 S0201 PDF

    A1101

    Abstract: C1002 S0201 D0201
    Text: Technical Datasheet 1SNK 161 006 D0201 21/01/10 Catalogue Page 1SNK 161 006 S0201 ZS4-SF-R Screw Clamp Terminal Block Fuse -P  rotect your circuits with 5x20 fuse terminal blocks compliant with IEC 60947-7-3 standard fuse not supplied with the terminal blocks ,


    Original
    D0201 S0201 F-69685 1SNK161006D0201 A1101 C1002 S0201 D0201 PDF

    2CSM200923R1801

    Abstract: 2CSM204753R1801 IEC 60947-3 ac-22b 2CSM204733R1801 2CSM200983R1801 2CSM204713R1801 2CSM200883R1801 2CSM204703R1801 IEC 60947-3 AC-22B IP20 2CSM202483R1801
    Text: t duc Pro ilable m ava ng fro ti star 2009 System Selection tables pro M compact Protection devices E 90 fuse-disconnectors E 90 E 90 fuse-disconnectors 2CSC400696F0201 E 90 series fuse-disconnectors are designed for connecting and disconnecting circuits under load, providing


    Original
    2CSC400696F0201 2CSM200923R1801 2CSM204753R1801 IEC 60947-3 ac-22b 2CSM204733R1801 2CSM200983R1801 2CSM204713R1801 2CSM200883R1801 2CSM204703R1801 IEC 60947-3 AC-22B IP20 2CSM202483R1801 PDF

    A1101

    Abstract: C1002 S0201
    Text: Technical Datasheet 1SNK 161 034 D0201 10/12/09 Catalogue Page 1SNK 161 034 S0201 ZS4-SF1-R Screw Clamp Terminal Block Fuse -P  rotect your circuit with 5x25 and 5x20 fuse terminal blocks fuse not supplied with the terminal blocks , - Compliant with IEC 60947-7-3 standard,


    Original
    D0201 S0201 F-69685 1SNK161034D0201 A1101 C1002 S0201 PDF

    ABB 60947-7-1

    Abstract: FUSE 239 IEC 60947-7-1 COLOR A1101 C1002 S0201 C1002-CB
    Text: Technical Datasheet 1SNK 161 036 D0201 10/12/09 Catalogue Page 1SNK 161 036 S0201 ZS4-SF1-T Screw Clamp Terminal Block Fuse -P  rotect your circuit with 5x25 and 5x20 fuse terminal blocks fuse not supplied with the terminal blocks , - Compliant with IEC 60947-7-3 standard,


    Original
    D0201 S0201 R0000 F-69685 1SNK161036D0201 ABB 60947-7-1 FUSE 239 IEC 60947-7-1 COLOR A1101 C1002 S0201 C1002-CB PDF

    IEC 60947-1

    Abstract: D0201 IEC 60947-7-1 IEC/EN 60947 A1101 C1002 S0201 1SNK161011D0201
    Text: Technical Datasheet 1SNK 161 011 D0201 21/01/10 Catalogue Page 1SNK 161 011 S0201 ZS4-SF1 Screw Clamp Terminal Block Fuse -P  rotect your circuit with 5x25 and 5x20 fuse terminal blocks, compliant with IEC 60947-7-3 standard fuse not supplied with the terminal blocks .


    Original
    D0201 S0201 R0000 F-69685 1SNK161011D0201 IEC 60947-1 D0201 IEC 60947-7-1 IEC/EN 60947 A1101 C1002 S0201 PDF

    A1101

    Abstract: C1002 S0201
    Text: Technical Datasheet 1SNK 161 035 D0201 10/12/09 Catalogue Page 1SNK 161 035 S0201 ZS4-SF1-R Screw Clamp Terminal Block Fuse -P  rotect your circuit with 5x25 and 5x20 fuse terminal blocks fuse not supplied with the terminal blocks , - Compliant with IEC 60947-7-3 standard,


    Original
    D0201 S0201 F-69685 1SNK161035D0201 A1101 C1002 S0201 PDF

    HTSS242150

    Abstract: HTSS372125 HTSS242125 Hi-Tech Fuses
    Text: Trans-Guard OS Shorty Fuse C A ⁄4-20 threaded hole 1 ⁄2" deep both ends 1 Dimensional Information NOMINAL FUSE VOLTAGE RATING (KV) 8.3 17.2 15.5 23.0 38.0 CURRENT RATING (AMPS) FUSE CAT. NO. 40 HTSS232040 50 65 80 100 125 150 165 200 30 40 50 65 80


    Original
    HTSS232050 HTSS232065 HTSS232080 HTSS232100 HTSS232125 HTSS232150 HTSS232165 HTSS232200 HTSS240030 HTSS240040 HTSS242150 HTSS372125 HTSS242125 Hi-Tech Fuses PDF

    delta hmi

    Abstract: hmi 1200 power cable fault locator NCS 1704-Y15R ABB EH 250 SUBSTATION CONTROL SYSTEM 60870 RTXP 18
    Text: %UHDNHU SURWHFWLRQ WHUPLQDO ZLWK DXWRPDWLF UHFORVLQJ DQG V\QFKURFKHFN HDWXUHV • Current - Breaker failure protection BFP) • Secondary system supervision - Fuse failure supervision (FUSE) • Control - Synchrocheck (SYN) - Automatic reclosing function (AR)


    Original
    009-BEN 112-BEN SE-721 096-BEN delta hmi hmi 1200 power cable fault locator NCS 1704-Y15R ABB EH 250 SUBSTATION CONTROL SYSTEM 60870 RTXP 18 PDF

    IEC 269-2

    Abstract: abb SACE csa 932 abb ABB SACE S.p.a 930-S 10,3X38 ABB ABB SACE 125 14X51 IEC 947-3 933N
    Text: E 930 fuse holders Customized protection for fuses of all sizes 603052/011 The wide range of ABB SACE System pro M modular devices has been extended with the E 930 series of fuse holders with new enhanced performance levels including operating at up to 690 V a.c.


    Original
    14x51 22x58 930-S IEC 269-2 abb SACE csa 932 abb ABB SACE S.p.a 10,3X38 ABB ABB SACE 125 IEC 947-3 933N PDF

    Fuse failure relay

    Abstract: 1MRK 514 001-BEN Rectification Failure Relay 019-BEN 4 change over relays phase failure relay 001-BEN combiflex relays 896-AA combiflex
    Text: Fuse supervisory relays RXBA and RXETB 1MRK 508 019-BEN Page 1 Issued June 2002 Changed since June 1999 Data subject to change without notice RXBA 4 Features SE 94 07 28 RXBA 4 • Detects single-, two- or three-phase fuse failures in less than 8 ms • Is used to block high-speed distance protection relay tripping in case of fuse failure


    Original
    019-BEN 004-AA 896-AA S-721 001-BEN Fuse failure relay 1MRK 514 001-BEN Rectification Failure Relay 019-BEN 4 change over relays phase failure relay 001-BEN combiflex relays 896-AA combiflex PDF

    NCS 1704-Y15R

    Abstract: SUBSTATION CONTROL SYSTEM 1704-Y15R microscada abb
    Text: $XWRPDWLF 5HFORVLQJ 7HPLQDO ZLWK 6\QFKURFKHFN 5 % &  1MRK 505 095-BEN Page 1 Revision: Issued: March 2003 Data subject to change without notice HDWXUHV • Secondary system supervision - Fuse failure supervision (FUSE) • Control - Synchrocheck (SYN)


    Original
    095-BEN 019-UEN 089-UEN 009-BEN 112-BEN SE-721 NCS 1704-Y15R SUBSTATION CONTROL SYSTEM 1704-Y15R microscada abb PDF

    ABB EH 1200

    Abstract: abb EH 150 stereo socket jack 3.5 4 pole ABB EH 250 2.1 mm female jack socket dc 283-1510 EH-1200 3.5 mm stereo jack plug 283-1175 EH-1175
    Text: Alectron Adapters, and Audio, Power, and MIC Connectors, and Cable Assemblies Cigarette Lighter Adapter Plug and Receptacles Plugs into automobile cigarette lighter socket for use with appliances. Includes LED indicator and a fuse holder. 3AG, 4 A-250 V fuse included. 12 VDC output.


    Original
    300-volt 5000-volt EH-1175. EH-1173. EH-1200 ZC-2630 EH-1174. EH-2177 JR-2731-3P. ABB EH 1200 abb EH 150 stereo socket jack 3.5 4 pole ABB EH 250 2.1 mm female jack socket dc 283-1510 3.5 mm stereo jack plug 283-1175 EH-1175 PDF

    Ferraz Shawmut

    Abstract: No abstract text available
    Text: Electrical Protection Helpfu l Tips ON . u Com Complying with OSHA IC Requirement for Fuses pliance s u Maintenanc e u Fuse OSHA Regulation OSHA implemented their “Final Rule” for electrical workplace safety outlines the latest requirements for fuse replacement. Specifically, The Final Rule Preamble Section V C Table 1 says that any


    Original
    PDF

    oesa 630

    Abstract: 1SCA022716R0180 1SCA022052R3900 OETLZW12 1SCA022071R3010 1SCA022439R4050 1SCA022078R1600 1SCA022714R8810 OETLZW16 OETLZT80L
    Text: Switch fuses OS 20.63 Technical dataselection overview Accessories, OS20.OS40 OS mini 4 3 1 3 5 6 4 N I 14 13 22 21 O Test N 2 4 I 9 O OFF 7 NO 1 Switch fuse 2 Extended shaft 3 Mounting frame for auxiliary contact 4 Auxiliary contact 5 Fuse monitor 6 Neutral link


    Original
    S02099A 1SCC311006C0201 1SCA022173R2780 1SCA022173R2940 1SCA022173R3320 1SCA022173R3590 1SCA022181R8070 S00039A 220VDC S00377A oesa 630 1SCA022716R0180 1SCA022052R3900 OETLZW12 1SCA022071R3010 1SCA022439R4050 1SCA022078R1600 1SCA022714R8810 OETLZW16 OETLZT80L PDF

    SA301B

    Abstract: SA-301B BAA1000 302B DC250V DS-401A SA-302B marking ac2
    Text: 警報用ヒューズ・ホルダ Fuseholders P•PL ヒューズホルダ Fuseholder P3受口はP3形ヒューズ用 P4受口はP4形ヒューズ用 P3 fuse holders are for type-P3 fuses. P4 fuse holders are for type-P4 fuses. •パネル取付タイプ Panel mounting type


    Original
    PDF

    2CSM204703R1801

    Abstract: No abstract text available
    Text: 8/26/13 ABB 2CSM204703R1801 Print View. ABB contact for United Print to Pdf. Kingdom E 92/32 PV General Information Extended Product Type: E 92/32 PV Product ID: 2CSM204703R1801 EAN: 8012542047032 Catalog Description: E 92/32 PV Fuse holder Long Description:


    Original
    2CSM204703R1801 2002/95/EC com/productdetails/2CSM204703R1801 ITSCE174E90FD 2CSM204703R1801 PDF

    7012540

    Abstract: SIBA 7012540 E180276 7012540.1.6 v650 7012540.16
    Text: G-Sicherungseinsätze / Miniature Fuse-Links Type 7012540 E180276 Zeit / Strom-Kennlinien 70 125 40 Time / current-characteristics Aufbau / Construction Zeit/Strom-Kennlinien Time-Current Characteristics 10 4 Type 7012540 t sec. 160mA - 800mA 1A - 5A 10 3


    Original
    E180276 160mA 800mA 7012540 SIBA 7012540 E180276 7012540.1.6 v650 7012540.16 PDF

    Fuse failure relay

    Abstract: 003-AA BROWN BOVERI DISTANCE RELAYS Rectification Failure Relay 003AA Rectification Failure Relay application brown boveri distance ASEA B03-8310E
    Text: ik II11 — ASEA BROWN BOVERI ABBRe,ays Type RXBA 4 £03-8310E Fuse failure relay# Abstract Application Changed since May 1983 Data subject to change without notic • Detects single-, two- or three-phase fuse


    OCR Scan
    003-AA B03-9301E B03-9382E S-72171 Fuse failure relay BROWN BOVERI DISTANCE RELAYS Rectification Failure Relay 003AA Rectification Failure Relay application brown boveri distance ASEA B03-8310E PDF

    Fuse failure relay

    Abstract: mercury wetted contact relay BROWN BOVERI connection diagram BROWN BOVERI generator connection diagram B03-9382E Mercury Relay Wetted relay mercury wetted "rk 427"
    Text: fM P IP ASEA BROWN BOVERI ABB Relays Abstract Type RXETA 1 B03-8311E Page 1 January 1985 Data subject to change without notice Fuse failure relay for threephase systems Operates at one- or two-phase fuse failures Two mercurywetted transfer contacts Not phase-sequence dependent


    OCR Scan
    B03-8311E 010-BN B03-9301E B03-9382E Fuse failure relay mercury wetted contact relay BROWN BOVERI connection diagram BROWN BOVERI generator connection diagram Mercury Relay Wetted relay mercury wetted "rk 427" PDF

    1MDB14003-EN

    Abstract: Fuse failure relay Rectification Failure Relay "rk 427" 004-AA abb combiflex
    Text: Types RXBA a n d RXETA im dbosoo 9 - en P age 1 Fuse supervision relays 990 Data subject to c hange without notice aovÊRi ABB Network Control & Protection RXBA 4 Features <90646 RXBA 4 • Detects s in g le -, tw o - or th ree-ph ase fuse failures in less than 8 ms


    OCR Scan
    30VERI 1MDB08009-EN 004-AA 011-BN 1MDB14003-EN Fuse failure relay Rectification Failure Relay "rk 427" 004-AA abb combiflex PDF