Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    GFCI BREAKER Search Results

    GFCI BREAKER Result Highlights (2)

    Part ECAD Model Manufacturer Description Download Buy
    ISL6174IRZ Renesas Electronics Corporation Dual Low Voltage Circuit Breaker Visit Renesas Electronics Corporation
    ISL6174IRZ-T Renesas Electronics Corporation Dual Low Voltage Circuit Breaker Visit Renesas Electronics Corporation

    GFCI BREAKER Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    Untitled

    Abstract: No abstract text available
    Text: TESTER-GFI & CIRCUIT CALIB GFCI and Circuit Tester Cat No: 5708-C UPC No: 783310076407 Description • • • • Allows instant testing of GFCI receptacles or GFCI circuit breaker protected circuits Checks 120VAC grounded outlets for correct/incorrect wiring


    Original
    5708-C 120VAC PDF

    Airpax 3 pole 100 amp ELCI breaker

    Abstract: shunt trip breaker Airpax ground fault circuit interrupter schematic diagram ac circuit breaker Airpax 3 pole 100 amp breaker SAE J1171 LELK1 airpax circuit breaker voltage ratings main circuit breaker GFCI schematic
    Text: PGFM Series GFCI GFCI Ground Fault Protection Sensing Module INTRODUCTION The LineGard PGFM GFCI Sensing Module is a ground fault or equipment leakage sensing device designed and manufactured by North Shore Safety, a leader in innovated safety products. The PGFM


    Original
    240VAC CFR1926 LEL12-1REC5-37583-30-G1-V LELK12-1REC5-37583-50-G1-V LEL12-1REC5-37583-30-G2-V LEL12-1REC5-37583-50-G2-V LEL121-1REC5-37275-30-G1-V LELK121-1REC5-37275-50-G1-V Airpax 3 pole 100 amp ELCI breaker shunt trip breaker Airpax ground fault circuit interrupter schematic diagram ac circuit breaker Airpax 3 pole 100 amp breaker SAE J1171 LELK1 airpax circuit breaker voltage ratings main circuit breaker GFCI schematic PDF

    Airpax

    Abstract: Airpax LEL UL 943 shunt trip breaker GFCI schematic airpax temperature limit switch airpax circuit breaker PGFM-111B CFR1926 shunt trip
    Text: PGFM Series GFCI GFCI Ground Fault Protection Sensing Module INTRODUCTION The LineGard PGFM GFCI Sensing Module is a ground fault or equipment leakage sensing device designed and manufactured by North Shore Safety, a leader in innovated safety products. The PGFM


    Original
    240VAC CFR1926 Airpax Airpax LEL UL 943 shunt trip breaker GFCI schematic airpax temperature limit switch airpax circuit breaker PGFM-111B shunt trip PDF

    Untitled

    Abstract: No abstract text available
    Text: 1113/25 Circuit Breaker GFCI Rocker Actuated Ground Fault Circuit Breaker Environmental Sealing Boot Shown is Carling Technologies PB Circuit Breaker GFCI FEATURES and BENEFITS • Environmentally protects to IP66/68 ingress rating • RUBRGLAS silicone rubber boot prevents


    Original
    IP66/68 MIL-DTL-5423 MIL-DTL-5423 PDF

    Untitled

    Abstract: No abstract text available
    Text: Product Overview NCS37000: Single CT GFCI Signal Processor For complete documentation, see the data sheet Product Description The NCS37000 is a signal processor for GFCI applications. The device integrates a flexible power supply including both shunt and


    Original
    NCS37000: NCS37000 NCS37000MNG NCS37000MNRG QFN-16 QFN-16 PDF

    SCHEMATIC circuit scr oscillator

    Abstract: GFCI schematic
    Text: NCS37000 Product Preview Ground Fault Circuit Interrupter GFCI Description The NCS37000 is a fully UL943 compliant signal processor for GFCI applications. The device integrates a flexible power supply (including both shunt and LDO regulators), differential fault, and


    Original
    NCS37000 UL943 QFN16 TSSOP-20 NCS37000/D SCHEMATIC circuit scr oscillator GFCI schematic PDF

    Untitled

    Abstract: No abstract text available
    Text: NCS37000 Product Preview Ground Fault Circuit Interrupter GFCI Description The NCS37000 is a fully UL943 compliant signal processor for GFCI applications. The device integrates a flexible power supply (including both shunt and LDO regulators), differential fault, and


    Original
    NCS37000 NCS37000 UL943 QFN16 NCS37000/D PDF

    Untitled

    Abstract: No abstract text available
    Text: NCS37010 Self Test With Lockout Ground Fault Circuit Interrupter GFCI The NCS37010 is a fully UL943 compliant signal processor for GFCI applications with self test and lockout. The device integrates a flexible power supply (including both shunt and LDO regulators),


    Original
    NCS37010 NCS37010 UL943 NCS37010/D PDF

    Untitled

    Abstract: No abstract text available
    Text: NCS37010 Self Test With Lockout Ground Fault Circuit Interrupter GFCI The NCS37010 is a fully UL943 compliant signal processor for GFCI applications with self test and lockout. The device integrates a flexible power supply (including both shunt and LDO regulators),


    Original
    NCS37010 UL943 NCS37010/D PDF

    Untitled

    Abstract: No abstract text available
    Text: PowerVerter Plus 3000W Heavy-Duty Inverter with 4 GFCI Outlets MODEL NUMBER: PV3000GFCI Highlights 12V DC input; 120V AC output; 4 outlets GFCI protected NEMA 5-15R 3000 watts continuous output; 6000 watts peak output (instantaneous) Quiet electricity for TVs, DVD


    Original
    PV3000GFCI 5-15R) PDF

    Untitled

    Abstract: No abstract text available
    Text: NCS37010 Product Preview Self Test With Lockout Ground Fault Circuit Interrupter GFCI http://onsemi.com The NCS37010 is a fully UL943 compliant signal processor for GFCI applications with self test and lockout. The device integrates a flexible power supply (including both shunt and LDO regulators),


    Original
    NCS37010 NCS37010 UL943 NCS37010/D PDF

    Untitled

    Abstract: No abstract text available
    Text: Power It! Safety Power Strip with 8 Outlets and 12-ft. Cord with GFCI Plug MODEL NUMBER: TLM812GF Highlights 8 outlets including transformer outlets and 4 safety covers 12 ft. cord with GFCI plug Cord wrap with hang holes Rugged metal case Applications Industrial


    Original
    12-ft. TLM812GF TLM812GF 145mm PDF

    Untitled

    Abstract: No abstract text available
    Text: FAN41501 Ground Fault Interrupter Self-Test Digital Controller Features Description • •  Meets 2015 UL943 Self-Test GFCI Requirement  Periodic EOL Testing without Compromising Normal GFCI Protection        Built-in Noise Filters Reduce False EOL Signals


    Original
    FAN41501 UL943 90-Minute com/dwg/MA/MA06A dwg/PKG-MA06A PDF

    Untitled

    Abstract: No abstract text available
    Text: FAN41501 Ground Fault Interrupter Self-Test Digital Controller Features Description • •  Meets 2015 UL943 Self-Test GFCI Requirement  Periodic EOL Testing without Compromising Normal GFCI Protection        Built-in Noise Filters Reduce False EOL Signals


    Original
    FAN41501 UL943 90-Minute com/dwg/MA/MA06A dwg/PKG-MA06A PDF

    Untitled

    Abstract: No abstract text available
    Text: Power It! Safety Power Strip with 8 Outlets and 25-ft. Cord with GFCI Plug MODEL NUMBER: TLM825GF Highlights 8 outlets including transformer outlets and 4 safety covers 25 ft. extra-long cord with GFCI plug Cord wrap with hang holes Rugged metal case Applications


    Original
    25-ft. TLM825GF TLM825GF 145mm PDF

    Untitled

    Abstract: No abstract text available
    Text: Power It! Safety Power Strip with 6 Outlets and 9-ft. Cord with GFCI Plug Highlights 6 outlets including transformer outlets and 4 safety covers MODEL NUMBER: TLM609GF 9 ft. cord with GFCI plug Cord wrap with hang holes Rugged metal case Applications Industrial


    Original
    TLM609GF TLM609GF PDF

    GFCI

    Abstract: No abstract text available
    Text: Ground Fault Circuit Interruptors LineGard 30 Amp Permanent Series Splice-in GFCI • Power and fault status indicators • Industrial design for rough service • Chemical and UV resistant enclosure • cULus Listed as a Class A GFCI per UL 943 and CSA 22.2 No. 144


    Original
    PDF

    Airpax

    Abstract: UL 943 GFCI Airpax ground fault circuit interrupter
    Text: PGFS Series 30 Amp Permanent Series Splice-In GFCI/ELCI INTRODUCTION The LineGard 30 Amp Permanent Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. The unique design offers the flexibility of splicing in protection of a GFCI


    Original
    PDF

    pfgs

    Abstract: Airpax
    Text: PGFS Series 30 Amp Multi-Phase Permanent Series Splice-In GFCI INTRODUCTION The LineGard 30 Amp Permanent Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. The unique design offers the flexibility of splicing in protection of a GFCI


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: PGFS Series 30 Amp Permanent Series Splice-In GFCI/ELCI INTRODUCTION The LineGard 30 Amp Permanent Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. The unique design offers the flexibility of splicing in protection of a GFCI


    Original
    120/24ays PDF

    GFCI BREAKER

    Abstract: klixon
    Text: PGFS Series 30 Amp Multi-Phase Permanent Series Splice-In GFCI INTRODUCTION The LineGard 30 Amp Permanent Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. The unique design offers the flexibility of splicing in protection of a GFCI


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: 8 | PC-Series - Introduction PC-Series Ground Fault Circuit Protection The PC-Series, AC Residual Current Circuit Breaker with Overcurrent Protection RCBO , combines the ground fault protection of a GFCI with the familiar overcurrent tripping characteristics of a normal circuit breaker.


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Protection Relays & Controls Ground-Fault Ground-Continuity Detection SE-502 SERIES Ground-Fault Ground-Continuity Detector Description The SE-502 Ground-Fault Ground-Continuity Detector provides Class-A GFCI trip level and trip times for personnel protection.


    Original
    SE-502 PDF

    Untitled

    Abstract: No abstract text available
    Text: PowerVerter 1250W Utility/Work Truck Inverter/Charger with 2 Outlets MODEL NUMBER: UT1250UL Highlights 12V DC or 120VAC input; 120VAC output; 2 GFCI protected outlets 1250 watts continuous, 1875 watts OverPower and 2500 watts DoubleBoost inverter output


    Original
    UT1250UL 120VAC UT1250UL BP-260 com/sku/UT1250UL. PDF