Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    IEC 947 Search Results

    IEC 947 Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TPD4E05U06DQAR Texas Instruments 4-Channel Ultra-Low-Capacitance IEC ESD Protection Diode 10-USON -40 to 125 Visit Texas Instruments Buy
    TPD1E05U06DPYR Texas Instruments 1-channel ultra-low-capacitance IEC ESD protection diode 2-X1SON -40 to 125 Visit Texas Instruments Buy
    V62/15608-01XE Texas Instruments 3.3-V Supply RS-485 With IEC ESD Protection 8-SON -55 to 125 Visit Texas Instruments Buy
    THVD2450DR Texas Instruments ±70-V fault-protected 3.3-V to 5-V RS-485 transceiver with IEC ESD Visit Texas Instruments Buy
    TPD1E05U06DPYT Texas Instruments 1-channel ultra-low-capacitance IEC ESD protection diode 2-X1SON -40 to 125 Visit Texas Instruments Buy
    SF Impression Pixel

    IEC 947 Price and Stock

    WAGO Innovative Connections IEC947-7-2

    TERMINAL BLOCKS 16MM 2 T20414
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Quest Components IEC947-7-2 62
    • 1 $6.69
    • 10 $3.345
    • 100 $3.122
    • 1000 $3.122
    • 10000 $3.122
    Buy Now

    CONTA-CLIP Inc IEC947-7-2

    TERMINAL BLOCKS 16MM 2 T20414
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Quest Components IEC947-7-2 22
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Buy Now

    IEC 947 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    XTRE10B31

    Abstract: XTMC9A10 380v type 2 coordination chart XTMC9A01 XTREC10B31 VDE 0660 iec 337 pt XTREC10B40 capacitor K1M 103 IEC EN 60947- 3 VDE 0660 107 Pub51210
    Text: IEC Contactors and Starters IEC Contactors and Starters 1.1 XT IEC Power Control Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    PDF C440/XT CA08100006Eâ V5-T1-253 XTRE10B31 XTMC9A10 380v type 2 coordination chart XTMC9A01 XTREC10B31 VDE 0660 iec 337 pt XTREC10B40 capacitor K1M 103 IEC EN 60947- 3 VDE 0660 107 Pub51210

    low voltage Contactor iec 947-4-1

    Abstract: IEC 60947-4-1 for ABB Contactor iec 947-4-1 motor starter HKF-11 1SCA 022 615 R 3860 OXS5X130 abb motor driver abb SK1-02 UA1-400
    Text: Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International and European Standards IEC 60 947-4-1 / IEC 60 947-2 EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates Rated insulation voltage Ui Acc. to IEC 158-1, IEC 60 947-4-1,


    Original
    PDF D-69006 D0201 low voltage Contactor iec 947-4-1 IEC 60947-4-1 for ABB Contactor iec 947-4-1 motor starter HKF-11 1SCA 022 615 R 3860 OXS5X130 abb motor driver abb SK1-02 UA1-400

    Allen-Bradley 100-D110

    Abstract: 100-D180 CONTACTOR 3phase winding data 3.7 kw to 110 kw Allen-Bradley 100-D630 100-D95 100-D630 100-d110 100-D180 Allen-Bradley contactor 100 100-DS1-11
    Text: Complete IEC Motor Control & Protection Solutions • IEC Contactors 100-D 50…500 kW · IEC Safety Contactors 100S-D 50…500 kW Bulletins 100/104-D, 100S-D IEC Contactors Overview/Product Selection Bulletin 100-D IEC Contactors Table of Contents • •


    Original
    PDF 100-D 100S-D 100/104-D, 100-D D-74834 100D-SG001B-EN-P Allen-Bradley 100-D110 100-D180 CONTACTOR 3phase winding data 3.7 kw to 110 kw Allen-Bradley 100-D630 100-D95 100-D630 100-d110 100-D180 Allen-Bradley contactor 100 100-DS1-11

    Untitled

    Abstract: No abstract text available
    Text: 22mm Specifications Electrical and Mechanical Characteristics Standard conformity: Approvals: Degree of protection: Temperature Range: IEC 60947-5-1 VDE0660 CSA - C22.2 No. 14-95 UL508 IEC 947 - 5 1 1990, IS 13947 ASTA UK certified as per IEC 947 - 5 - (1) 1990


    Original
    PDF VDE0660 UL508 UL508:

    IEC/EN60947-4-1

    Abstract: contactor coils 220v timer contactor contactor coils 24v contactor coils 415v a1218 380Vac A1725 P1016 contactor coils 415v Ac
    Text: Introducing P&B PBC series IEC-Type Contactors and Accessories P&B PBC Series IEC-Type Contactors and Accessories KEY FEATURES DESCRIPTION Contactors offer three pole Compact AC coil contactors in three frame widths offer ratings from 9 amps to 80 amps AC-3 per IEC 947-4 .


    Original
    PDF PBT-322 PBT-324 IEC/EN60947-4-1 contactor coils 220v timer contactor contactor coils 24v contactor coils 415v a1218 380Vac A1725 P1016 contactor coils 415v Ac

    IEC-947-5-1 AC15 B300

    Abstract: IEC 947-1 B300 DC-13 R300 kv86
    Text: Control and signalling units Ø 16 General : pages 2 to 5 References : pages 8 to 21 Dimensions : pages 22 to 25 Harmony style 6 Pushbuttons, switches and pilot lights, with double insulated bezel Characteristics Environment Conforming to standards IEC 947-1, IEC 947-5-1, IEC 947-5-4,


    Original
    PDF C22-2 AC-15 DC-13 VA-230 AC-15, IEC-947-5-1 AC15 B300 IEC 947-1 B300 DC-13 R300 kv86

    IEC 947-7-1 terminal block

    Abstract: No abstract text available
    Text: Module no:2771007 LabelId:2771007 Operator:Phoenix 17:43:18, Donnerstag, 28. Juni 2001 UKKB 10/2,5 Bridgeable in both levels Terminal width 10.2 rigid IEC solid 2 [mm ] 1 IEC 947-7-1 ) 0.5-16 2 IEC 947-7-1 ) 0.2-4 flexible stranded AWG I U [A] [V] 0.5-10


    Original
    PDF

    3RV1331-4FC10

    Abstract: 3RV1341-4JC10 3RV1321-4AC10 3RV13 3RV1331-4EC10 3RV1341-4KC10 3RV1321-1FC10 3RV1321-4BC10 3RV1331-4GC10 Contactor iec 947-4-1
    Text: 3RU11 Thermally Delayed Overload Relays up to 100 A • CLASS 10 SIRIUS 3R Technical data according to IEC 60 947-4-1 and IEC 60 947-5-1 Type 3RU11 16-. 3RU11 26-. 3RU11 36-. 3RU11 46-. Size S00 S0 S2 S3 Trip class acc. to IEC 60 947-4-1 CLASS 10


    Original
    PDF 3RU11 EX-97 3RV1331-4FC10 3RV1341-4JC10 3RV1321-4AC10 3RV13 3RV1331-4EC10 3RV1341-4KC10 3RV1321-1FC10 3RV1321-4BC10 3RV1331-4GC10 Contactor iec 947-4-1

    XCM NFC 63-145 y2

    Abstract: XCM-A110 XCM-A102 XCMA102 XCM-A115 XCM-F102 NFC 63-145 Y2 XCM-F110 XES-P2151 XCKJ10511H29
    Text: Limit switches Double insulated, types XCK-P and XCK-T General characteristics Environment Conforming to standards 3 Products IEC 947-5-1, IEC 337-1, EN 60 947-5-1, NF C 63-146, VDE 0660-200, UL 508, CSA C22-2 n° 14 Machine assemblies IEC 204-1, EN 60 204-1, NF C 79-130


    Original
    PDF C22-2 XCR-A12 XCR-A15 XCR-Z12 XCM NFC 63-145 y2 XCM-A110 XCM-A102 XCMA102 XCM-A115 XCM-F102 NFC 63-145 Y2 XCM-F110 XES-P2151 XCKJ10511H29

    Untitled

    Abstract: No abstract text available
    Text: Module no:3001640 LabelId:3001640 Operator:Phoenix 18:40:32, Donnerstag, 28. Juni 2001 ZFKI 2,5 Terminal width 5.2 IEC rigid flexible I U [A] [V] [mm ] solid 1) IEC 947-7-1 0.2-4 0.2-2.5 24-12 32 800 2) IEC 947-7-2 0.2-4 0.2-2.5 24-12 – – 2 CAV stranded AWG


    Original
    PDF

    KD 605

    Abstract: G700 100-FLAM5 bs 5424 380V 415v motor 100G1000 100-EF22 100-CP550 TZS734 5A 1 pole relay 220v ac
    Text: Bulletin 100-G — IEC Contactors Table of Contents Selection Guide Description Page Bulletin 100-G IEC Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Bulletin 100-G IEC Contactors 1 Bulletin 100-G Contactors • • • • • • •


    Original
    PDF 100-G 100-G 60V/575V 100-G550/100-G700, 100-G700, -860/100-G1000, -860/100-G700, KD 605 G700 100-FLAM5 bs 5424 380V 415v motor 100G1000 100-EF22 100-CP550 TZS734 5A 1 pole relay 220v ac

    harting cable

    Abstract: Harting M12 EN 50173 M12-RJ45 harax M12
    Text: Adapter M8/M12 Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX® M8-S/M12-S Rated voltage Rated current Conductor cross section Diameter of individual strands Conductor insulation material


    Original
    PDF M8/M12 M8-S/M12-S M12-S: M12-L harting cable Harting M12 EN 50173 M12-RJ45 harax M12

    ir 9027

    Abstract: ir9027 90 KW motor triac ansteuerung dold
    Text: Leistungselektronik / Installationstechnik Sanftanlaufgerät IR 9027 ministart 0214025 • nach IEC/EN 60 947-4-2, IEC/EN 60 947-4-3 · erhöht die Lebensdauer von Asynchronmotoren und mechanischen Antriebskomponenten · einfache nachträgliche Montage auch in bestehende Anlagen


    Original
    PDF D-78114 ir 9027 ir9027 90 KW motor triac ansteuerung dold

    Untitled

    Abstract: No abstract text available
    Text: Bussmann Disconnect Switch BDCF30 Fusible, 30A, 600V Catalog Symbols*: BDCF30J6, BDCF30CC6 Ampere Rating: 30 Amperes Voltage Rating: 600 Volts Agency Approvals: U.L. Listed, Guide WPZX, File E155129 CSA Certified, File 58077M9 IEC 947-1, IEC 947-3 General Information:


    Original
    PDF BDCF30 BDCF30J6, BDCF30CC6 E155129 58077M9 98/CSA BDCF30J6 SB98107

    IEC 337-1

    Abstract: IEC 947-5-1 pilot lamp IEC 60947-5-1 pilot lamp Contact to Push Buttons IEC 60947-5-1 ip 65 NEMA A600 EN50013 A600 Q600 IEC-947-5-1 ip 66
    Text: Control Stations - Plastic Emergency Stop General Characteristics: Products Control stations Reference standard IEC 60947-5-1, EN 60947-5-1, IEC 337-1, UL 508, CSA C-22-2 n° 14 Approval Protection degree IP 65/IP 66 as per IEC , NEMA 4/4X (special version)


    Original
    PDF C-22-2 65/IP 500Hz) IEC 337-1 IEC 947-5-1 pilot lamp IEC 60947-5-1 pilot lamp Contact to Push Buttons IEC 60947-5-1 ip 65 NEMA A600 EN50013 A600 Q600 IEC-947-5-1 ip 66

    dold ik

    Abstract: motors M8155 M8095 M8153 MIT X4
    Text: Leistungselektronik Drehzahlsteller SX 9240 0238773 • nach IEC/EN 60 947-1, IEC/EN 60 947-4-2 · zur Drehzahlverstellung 3-phasiger spannungsregelbarer Drehstrom-Asynchronmotoren · Sollwerteinstellung über frontseitigen Drehschalter Sollwertpoti · zusätzlicher galvanisch vom Netz getrennter Steuereingang für


    Original
    PDF 168use, SX9240 M8153 DC24V/ AC20V M8157 D-78114 dold ik motors M8155 M8095 M8153 MIT X4

    Untitled

    Abstract: No abstract text available
    Text: Module no:3003758 LabelId:3003758 Operator:Phoenix 18:47:00, Donnerstag, 28. Juni 2001 MZFK 1,5 Mini spring cage terminal block, bridgeable Terminal width 5.2 mm AV IEC rigid flexible solid stranded IEC 947-7-1 0.14-2.5 0.14-1.5 2 [mm ] Description I U AWG


    Original
    PDF 10-pos.

    Untitled

    Abstract: No abstract text available
    Text: Module no:1414129 LabelId:1414129 Operator:Phoenix 15:55:25, Donnerstag, 28. Juni 2001 MTTB 1,5 Double level terminal block, bridgeable in both levels Terminal width 4.2 IEC rigid solid 2 [mm ] IEC 947-7-1 flexible stranded AWG 0.14-1.5 0.14-1.5 26-16 I


    Original
    PDF 10-position,

    ZBY-5100

    Abstract: ZB4BZ009 ZBZ-010 XB5-A ZBV-B37 ZB4-BZ009 zbe-701 ZBZ010 ZB4-BZ079 xb5a
    Text: Characteristics, references Installation system Profil front panels for Harmony style 4 and style 5 pushbuttons, switches and pilot lights Characteristics Conforming to standards IEC 947-1, IEC 947-5-1, UL 508, CSA C-22-2 n˚ 14 Product certifications CSA, UL


    Original
    PDF C-22-2 KT12-BHC KT12-F ZBE-70p/ZBV-Bp7 ZBZ-010 ZBZ-006 ZB4-BZ009 ZBY-5100 ZB4BZ009 ZBZ-010 XB5-A ZBV-B37 ZB4-BZ009 zbe-701 ZBZ010 ZB4-BZ079 xb5a

    Untitled

    Abstract: No abstract text available
    Text: Module no:2775456 LabelId:2775456 Operator:Phoenix 17:44:58, Donnerstag, 28. Juni 2001 UDK 3-PE Terminal width 5.2 Current carrying capacity of mounting rails, seeproduct-line info. IEC 2 [mm ] IEC 947-7-2 rigid solid 0.2-4 flexible stranded AWG 0.2-2.5


    Original
    PDF 10-section,

    Untitled

    Abstract: No abstract text available
    Text: Module no:3002584 LabelId:3002584 Operator:Phoenix 18:44:08, Donnerstag, 28. Juni 2001 UK 5-RETURN-PE Terminal width 6.2 IEC rigid [mm ] solid 2 IEC 947-7-2 0.2-6 flexible stranded AWG 0.2-4 24-10 Current carrying capacity of mounting rails, seeproduct-line info.


    Original
    PDF 10-section

    S251-L20

    Abstract: No abstract text available
    Text: . S 2 5 0 & S270 240VAG Class b ^ 5 tJ "L IT E M Approvals: No. of poles: Tripping characteristic: Rated currents: Rated voltage: UL1077 CSA C22.2 VDE 0641 IEC 898 IEC 947 UL1077 CSA C22.2 VDE 0660 IEC 898 IEC 947 1,2,3, 1+N.3+N 1,2,3,4, 1+N,3+N L K 6 to 32A


    OCR Scan
    PDF 240VAG UL1077 UL1077 240VAC 60VDC 110VDC 240/415VAC S251-L20

    IEC 947-5-2

    Abstract: din iec 512 teil 2 34mm2
    Text: ELKE 412 PGü ELKE 412 PG 9 P ELKE 51? PG U ELKE 512 PG H P 933 039-100 933 044-100 933 040-100 933 045-100 100 100 100 100 4 4 5 5 IEC 947-5-2 DIN/VD E 0600 Teil 208 A 2 IEC 947-5-2 DIN/VDE 0600 Teil 208 A 2 IEC 947-5-2 DIN/VDE 0600 Teil 208 A 2 IEC 947-5-2


    OCR Scan
    PDF

    IEC 947-5-2

    Abstract: elwika
    Text: ELWIKA 4012 PG 9 ELWIKA 5012 PG 7 ELWIKA 5012 PG 9 4 5 5 IEC 947-5-2 DIN/VDE 0600 Teil 208 A 2 IEC 947-5-2 DIN/VDE 0600 Teil 208 A 2 IEC 947-5-2 DIN/VDE 0600 Teil 208 A 2 Leitungsdose abgewinkelte Bauform, unmontiert, Leitungsabfangung mittels Klemmkàfig


    OCR Scan
    PDF UC250V IEC 947-5-2 elwika