Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    INTRINSICALLY SAFE PLC Search Results

    INTRINSICALLY SAFE PLC Result Highlights (1)

    Part ECAD Model Manufacturer Description Download Buy
    Safety-Light-Curtain Renesas Electronics Corporation Safety Light Curtain Reference Design Visit Renesas Electronics Corporation

    INTRINSICALLY SAFE PLC Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    PT500 temperature sensor

    Abstract: PT500 IEC 751 W5Re-W26Re IEC 751 PT500 SENSOR MoRe5-MoRe41 Phoenix Ni1000 2-wire Pt1000 transmitter 4.20 mA PT500 PT1000 thermocouple
    Text: Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer MCR-FL-T-LP-I-Ex 1. Brief Description – For resistance thermometers, thermocouples, and resistance and voltage sensors – Can be mounted on symmetrical EN 50 022 DIN rails Temperature


    Original
    PDF eebt02 PT500 temperature sensor PT500 IEC 751 W5Re-W26Re IEC 751 PT500 SENSOR MoRe5-MoRe41 Phoenix Ni1000 2-wire Pt1000 transmitter 4.20 mA PT500 PT1000 thermocouple

    Untitled

    Abstract: No abstract text available
    Text: Low Power HART Modem AD5700/AD5700-1 Data Sheet FEATURES GENERAL DESCRIPTION HART-compliant fully integrated FSK modem 1200 Hz and 2200 Hz sinusoidal shift frequencies 115 A maximum supply current in receive mode Suitable for intrinsically safe applications


    Original
    PDF AD5700/AD5700-1 AD5700-1only) 24-Lead CP-24-10

    ad5421

    Abstract: ad5755 MO-220-WGGD-8 ad5700 FSK modulator ad5700
    Text: Low Power HART Modem AD5700/AD5700-1 Data Sheet FEATURES GENERAL DESCRIPTION HART-compliant fully integrated FSK modem 1200 Hz and 2200 Hz sinusoidal shift frequencies 115 µA maximum supply current in receive mode Suitable for intrinsically safe applications


    Original
    PDF AD5700-1 AD5700/AD5700-1 AD5700/AD5700-ernal 6-11-2012-A 24-Lead ad5421 ad5755 MO-220-WGGD-8 ad5700 FSK modulator ad5700

    AD5421

    Abstract: AD5700BCPZ DN25 BSP129 pt100 sensor interface WITH ADC INTRINSICALLY SAFE PLC ad5755 ABLS-3-6864MHZ-L4Q-T LFCSP-WQ ad5700
    Text: Low Power HART Modem AD5700/AD5700-1 Data Sheet FEATURES GENERAL DESCRIPTION HART-compliant fully integrated FSK modem 1200 Hz and 2200 Hz sinusoidal shift frequencies 115 A maximum supply current in receive mode Suitable for intrinsically safe applications


    Original
    PDF AD5700-1 AD5700/AD5700-1 AD5700/AD5700-1 72809A 24-Lead AD5421 AD5700BCPZ DN25 BSP129 pt100 sensor interface WITH ADC INTRINSICALLY SAFE PLC ad5755 ABLS-3-6864MHZ-L4Q-T LFCSP-WQ ad5700

    Resistance characteristic Pt1000

    Abstract: PT100 SENSOR rtd sensor pt100 temperature transmitter pt100 4-20ma atex Resistance characteristic Ni1000 PT1000 PT500 PT1000 thermocouple PT500 IEC 751 PT500 temperature sensor
    Text: Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer MCR-FL-HT-T-I-Ex 1. Brief Description – For resistance thermometers, thermocouples, and resistance and voltage sensors – For installation in Form B connection head POWER FL I


    Original
    PDF

    ad5700

    Abstract: ad5421 ad5755 pt100 sensor interface with microcontroller
    Text: Low Power HART Modem AD5700/AD5700-1 Data Sheet FEATURES GENERAL DESCRIPTION HART-compliant fully integrated FSK modem 1200 Hz and 2200 Hz sinusoidal shift frequencies 115 A maximum supply current in receive mode Suitable for intrinsically safe applications


    Original
    PDF AD5700-1 AD5700/AD5700-1 AD5700/AD5700-1 72809A 24-Lead ad5700 ad5421 ad5755 pt100 sensor interface with microcontroller

    Untitled

    Abstract: No abstract text available
    Text: Low Power HART Modem AD5700/AD5700-1 Data Sheet FEATURES GENERAL DESCRIPTION HART-compliant fully integrated FSK modem 1200 Hz and 2200 Hz sinusoidal shift frequencies 115 A maximum supply current in receive mode Suitable for intrinsically safe applications


    Original
    PDF AD5700-1only) AD5700/AD5700-1 AD5700/AD5700-1 6-11-2012-A 24-Lead

    hart protocol

    Abstract: Resistance characteristic Pt1000 Pt1000 RTD Sensor Resistance characteristic Ni1000 ni1000 DIN 43760 Pt100 transmitter 4.20 mA Resistance thermometer mw Thermocouple Type K linearization PT1000 PT500
    Text: Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HARTProtocol MCR-FL-HT-TS-I-Ex 1. Description – For resistance thermometers, thermocouples, and resistance and voltage sensors POWER FL I Dimensional drawing for MCR-FL-HT-TS-I-Ex


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Low Power HART Modem AD5700/AD5700-1 Data Sheet FEATURES GENERAL DESCRIPTION HART-compliant fully integrated FSK modem 1200 Hz and 2200 Hz sinusoidal shift frequencies 115 µA maximum supply current in receive mode Suitable for intrinsically safe applications


    Original
    PDF AD5700/AD5700-1 AD5700-1 24-Lead CP-24-10

    PT100 Emerson

    Abstract: Pt 1000 sensor connection SN29500 Siemens PT100 temperature sensor RTD PT100 B DIN 43729 Wiring Diagram pt-100 siemens Siemens PT100 temperature sensor ex Siemens PT100 temperature sensor 2 wire Pt 1000 sensor siemens W5Re-W26Re
    Text: MCR-FL-HT-TS-I-EX Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer for Connection Head With HART Protocol INTERFACE Data Sheet Temperature 1 PHOENIX CONTACT - 08/2006 Description Customer-specific measuring range settings, linearization,


    Original
    PDF

    ad5421

    Abstract: ad5755 DSA006979 hart modem ad5700 sensor PT100
    Text: Low Power HART Modem AD5700/AD5700-1 Preliminary Technical Data FEATURES GENERAL DESCRIPTION HART-compliant fully integrated FSK modem 1200 Hz and 2200 Hz sinusoidal shift frequencies 115 A maximum supply current in receive mode Suitable for intrinsically safe applications


    Original
    PDF AD5700-1 AD5700/AD5700-1 72809A 24-Lead AD5700 ad5421 ad5755 DSA006979 hart modem sensor PT100

    EMERSON PT 100 RESISTANCE THERMOMETER

    Abstract: Pt 100 RTD Siemens Siemens PT100 temperature sensor RTD tmt 112 Wiring Diagram pt-100 siemens Siemens PT100 temperature sensor din iec 60751 DXR275 Endress siemens pt100 RTD PT-100
    Text: MCR-FL-TS-LP-I-EX SIL IEC 61 508 Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol INTERFACE Data Sheet Temperature 1 PHOENIX CONTACT - 08/2006 Description Customer-specific measuring range settings, linearization,


    Original
    PDF

    pt100 ADC

    Abstract: temperature sensor pt100 pt100 interface WITH ADC CD-06 sensor AD5700-1 ad5421 D1043 ABLS-3-6864MHZ-L4Q-T ad5700 MO-220-WGGD-8
    Text: Low Power HART Modem AD5700/AD5700-1 Data Sheet FEATURES GENERAL DESCRIPTION HART-compliant fully integrated FSK modem 1200 Hz and 2200 Hz sinusoidal shift frequencies 115 A maximum supply current in receive mode Suitable for intrinsically safe applications


    Original
    PDF AD5700-1 AD5700/AD5700-1 AD5700/AD5700-1 6-11-2012-A 24-Lead pt100 ADC temperature sensor pt100 pt100 interface WITH ADC CD-06 sensor ad5421 D1043 ABLS-3-6864MHZ-L4Q-T ad5700 MO-220-WGGD-8

    Bendix PT1H-10-6P

    Abstract: Dynisco PT1H-10-6P pressure sensor sp 20 pressure sensor sp 13 INTRINSICALLY SAFE PLC intrinsically safe Bolt Torque
    Text: SPX2241 Features • • • • • • HARTTM digital communication Better than +/- 1.0% combined error 4 - 20 mA loop-powered output 0 - 250 to 0 - 1,000 psi Explosion Proof, Intrinsically Safe/ATEX approved Meets PED and CE requirements Benefits • •


    Original
    PDF SPX2241 SPX2241 SPX2241E 1-800-Dynisco Bendix PT1H-10-6P Dynisco PT1H-10-6P pressure sensor sp 20 pressure sensor sp 13 INTRINSICALLY SAFE PLC intrinsically safe Bolt Torque

    level transmitter for diesel tank

    Abstract: ultrasonic level transmitter LU20-5001 diesel tank level sensor LB10-1001 Digital Panel Meter up 413 LM50 ultrasonic interface ultrasonic range meter tank DIESEL level sensor
    Text: Echotouch Echotouch 0504 DS3_1 TM Ultrasonic Level Transmitter Description Offered in CSA and Cenelec approved intrinsically safe or general purpose configurations, the two-wire ultrasonic transmitter provides noncontact level measurement up to 18’ or 5.4m, and is ideally suited for


    Original
    PDF

    SD150X

    Abstract: SD275X SD32T3 SD32R SD32X BRI7000 BIL7000 ISP7000 DX070 TAG57
    Text: SD Series Ultra-slim user-friendly devices for protecting electronic equipment and systems against surges on signal and I/O cabling ● Range of ATEX Certified intrinsically safe surge protectors ● Ultra-slim space-saving design; easy installation ● Multistage hybrid protection circuitry – 10kA


    Original
    PDF SD150X SD275X SD32T3 SD32R SD32X BRI7000 BIL7000 ISP7000 DX070 TAG57

    Untitled

    Abstract: No abstract text available
    Text: Valve control module 4-channel IMB-DO-44Ex-P/24VDC The 4-channel valve control module IMBDO-44Ex-P/24VDC provides current and voltage limited, intrinsically safe output voltage. Loads in the Ex area can thus be triggered directly. The device can be operated with PNP


    Original
    PDF IMB-DO-44Ex-P/24VDC IMBDO-44Ex-P/24VDC 94/9/EG 2013-07-13T20 D-45472

    BENDIX ptih-10-6p

    Abstract: Sensotec wiring diagram Sensotec pressure transmitter MS3102E-14S-2P PT06A-10-6S BENDIX INTRINSICALLY SAFE PLC pt06e-10-6s BENDIX ptih sensotec 1502 Sensotec pressure
    Text: Model 425 Wing Union Pressure Transmitter Order Code BP425 n n n n n n n n Long Life X-750 Material Rugged, Robust Design 1502 2” Wing Union Size RFI/ EMI Protected Intrinsically Safe Quick Delivery Service 0.2% Accuracy Optional On-Board Temperature Sensor


    Original
    PDF BP425 X-750 BENDIX ptih-10-6p Sensotec wiring diagram Sensotec pressure transmitter MS3102E-14S-2P PT06A-10-6S BENDIX INTRINSICALLY SAFE PLC pt06e-10-6s BENDIX ptih sensotec 1502 Sensotec pressure

    1771-IN075

    Abstract: INTRINSICALLY SAFE PLC 1771-IFM ROCKWELL PLC Allen-Bradley 1771 dc output module
    Text: Intrinsically Safe Fast Millivolt Input Module User Manual Catalog Numbers 1771-IFMS Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local


    Original
    PDF 1771-IFMS) PN-40187 1771-IN075 INTRINSICALLY SAFE PLC 1771-IFM ROCKWELL PLC Allen-Bradley 1771 dc output module

    Untitled

    Abstract: No abstract text available
    Text: Valve control module 4-channel IMB-DO-44Ex-N/24VDC The 4-channel valve control module IMBDO-44EX-N/24VDC is current and voltage limited and provides intrinsically safe output voltage. Loads in the Ex area can thus be triggered directly. The device can be operated


    Original
    PDF IMB-DO-44Ex-N/24VDC IMBDO-44EX-N/24VDC 94/9/EG 2013-07-13T20 D-45472

    SYM20C15

    Abstract: 20c15 LSI - 20C15 4608 kHz lsi 20c15 20c15 Hart Modem A5191HRTP hart modem hlx* crystal active bandpass filter khz
    Text: A5191HRT AMIS HART Modem 1.0 Features • Can be used in designs presently using the SYM20C15 • Low power: optimal for intrinsically safe applications • Single-chip, half-duplex 1200 bits per second FSK modem • CMOS compatible • Bell 202 shift frequencies of 1200 Hz and 2200 Hz


    Original
    PDF A5191HRT SYM20C15 28-pin 32-pin TEST12 A5191Htor SYM20C15 20c15 LSI - 20C15 4608 kHz lsi 20c15 20c15 Hart Modem A5191HRTP hart modem hlx* crystal active bandpass filter khz

    lsi 20c15

    Abstract: No abstract text available
    Text: A5191HRT AMIS HART Modem 1.0 Features • Can be used in designs presently using the SYM20C15 • Low power: optimal for intrinsically safe applications • Single-chip, half-duplex 1200 bits per second FSK modem • CMOS compatible • Bell 202 shift frequencies of 1200 Hz and 2200 Hz


    Original
    PDF A5191HRT SYM20C15 28-pin 32-pin TEST12 lsi 20c15

    Untitled

    Abstract: No abstract text available
    Text: DETECTION SAFETY BARRIER RS485 INPUT RS485 OUTPUT HALF-DUPLEX FEATURES l Three-port isolation (input, output and power supply) l High isolation voltage (2500VAC/60S) l High reliability (MTBF>500,000 hours) ——TD100-EX-485-xx Series GENERAL DESCRIPTION


    Original
    PDF RS485 2500VAC/60S) TD100-EX-485-xx TD100-EX-485-xx RS-485

    Untitled

    Abstract: No abstract text available
    Text: Isolated safety barrier TD10x-EX-485-xx FULL-DUPLEX Series FEATURES RS485 INPUT RS485 OUTPUT (FULL-DUPLEX) l TD102-EX-485-xx(RS485 output) TD103-EX-485-xx(RS232 output) l l Input, output and power supply isolated from each other High isolation voltage (2500VAC/60S)


    Original
    PDF TD10x-EX-485-xx RS485 TD102-EX-485-xx TD103-EX-485-xx RS232 2500VAC/60S) TD10x-EX-485-xx RS-485