Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LANDIS FR Search Results

    LANDIS FR Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    Untitled

    Abstract: No abstract text available
    Text: Landis+Gyr S650 Smart Grid Terminal A smart grid innovation Landis+Gyr S650 Smart Grid Terminal 2 Landis+Gyr S650 Smart Grid Terminal Emerging challenges in the distribution system. Utilities, both distribution network operators DNOs and distribution system operators (DSOs), are facing growing


    Original
    PDF

    VOC sensor

    Abstract: QPA84 automatic room power controller acetone gas sensor STAEFA "VOC Sensor" Siemens room temperature sensor landis and staefa 1571S02 1571S
    Text: 1 Indoor Air Quality Controller 571 QPA84 With integrated VOC 1 ) sensor, operating voltage AC 230 V, two-position output non-potential-free relay contact) 1) VOC = Volatile Organic Compounds Use In ventilation plant to optimize the indoor air quality and the consumption of energy by


    Original
    QPA84 QAP84 dampe0-2-11 1571G01 CM1N1571E 1571M01 VOC sensor QPA84 automatic room power controller acetone gas sensor STAEFA "VOC Sensor" Siemens room temperature sensor landis and staefa 1571S02 1571S PDF

    QBE620-P10

    Abstract: AQB51 QBE620-P16 Landis QBE620-P40 AQB22 QBE620-P QBE620-P25 QBE620-P5 QBE620-P1
    Text: 1 904 Pressure sensor for liquid and gaseous media QBE620-P. Pressure sensor for the measurement of positive pressure in HVAC applications. • Piezo-resistive system of measurement • DC 0 .10 V output signal • Complete sensor cast in synthetic resin


    Original
    QBE620-P. the/336 EN50081-1, EN50081-2, EN50082-2 CA1N1904E AQB22 QBE620-P10 AQB51 QBE620-P16 Landis QBE620-P40 QBE620-P QBE620-P25 QBE620-P5 QBE620-P1 PDF

    staefa

    Abstract: Landis Siemens room temperature sensor QAA32 NTC Siemens ntc resistor Siemens temperature sensor landis and staefa NTC SIEMENS K 30 landis and staefa temperature
    Text: 1 747 Room Temperature Sensor QAA32 NTC resistor sensing element Use In HVAC plants to acquire the room temperature. Functions 1747D01 Ω 9000 7000 5000 The sensor acquires the room temperature by means of its NTC resistor. The resistance value changes according to the ambient


    Original
    QAA32 1747D01 ARG70 ARG70 0502-G 1747G01 QAA32 CE1N1747en 3001M02 staefa Landis Siemens room temperature sensor NTC Siemens ntc resistor Siemens temperature sensor landis and staefa NTC SIEMENS K 30 landis and staefa temperature PDF

    AlMgSi1

    Abstract: Differential Pressure siemens QBE64-dp4 staefa Landis Landis Staefa QBE siemens air pressure sensors AQB51 EN50081 QBE64
    Text: 1 921 Differential pressure sensor QBE64-DP4 for neutral and mildly corrosive liquids and gases Differential pressure sensor, suitable for gases or liquids, for the measurement of positive or negative pressures and pressure differentials in HVAC systems. • Measuring system based on ceramic lever technology


    Original
    QBE64-DP4 QBE64-DP4 EN50082-2 CA1N1921E AlMgSi1 Differential Pressure siemens staefa Landis Landis Staefa QBE siemens air pressure sensors AQB51 EN50081 QBE64 PDF

    polygyr

    Abstract: QBE61 qbe61.2 Landis PN40 water differential pressure sensor chilled water system landis and staefa Differential Pressure siemens siemens humidity sensor
    Text: 1 Differential Pressure Sensor 915 QBE61.2-dp0,5 This sensor delivering an active measuring signal of DC 0.10 V and works on a AC 24 V operating voltage. Measuring ranges between 0 and 0.5 bar differential pressure. Application Sensing of differential pressure in heating, ventilating and air conditioning plants.


    Original
    QBE61 1915G01 CM1N1915E 1901M02E 1915M01 CM1N3463E polygyr qbe61.2 Landis PN40 water differential pressure sensor chilled water system landis and staefa Differential Pressure siemens siemens humidity sensor PDF

    IEC62053

    Abstract: IEC62053-21 ACCURACY CLASS
    Text: Electricity Meters IEC/MID Elektrizitätszähler Industrie und Gewerbe Residential Single Phase BS Standard Credit Meter 5235 Technical data The 5235 is a whole current static electricity meter capable of measuring kWh in single and two rate variants. Date: 05/12/08


    Original
    IB058 20-240V, 50/60Hz IEC-Specif6-21 BS5685 IEC62053 IEC62053-21 ACCURACY CLASS PDF

    ptc 1713 siemens

    Abstract: FR-T1K staefa t1 sensor staefa T1 Sensor element Sunlight sensor siemens Landis FR Siemens room temperature sensor 1713 siemens Landis
    Text: 1 735 FR-T1K Room temperature sensor Compact room sensor for measurement of the air temperature in conjunction with HVAC systems • • • • T1 measuring element Suitable for wall-mounting Ideal where space is limited Discreet appearance FR-T1K Technical data


    Original
    VDI/VDE3522 IEC529 CA1N1735E ptc 1713 siemens FR-T1K staefa t1 sensor staefa T1 Sensor element Sunlight sensor siemens Landis FR Siemens room temperature sensor 1713 siemens Landis PDF

    Siemens Ni1000 temperature sensor

    Abstract: landis staefa QAM22 staefa t1 sensor ni1000 Ni1000 temperature sensor Siemens QAM22 qam22 AQA61 EN50022-35 siemens qaa
    Text: 5 Signal transducer T1 for Ni1000 temperature sensor 142 AQA61.20 Signal transducer allowing the use of Ni1000 sensors for controllers with a T1 sensor input.  Converts an Ni1000 sensor signal into a T1-type output signal  Transducer supply from connected controller


    Original
    Ni1000 AQA61 QAM22 AQA61. IEC529 Siemens Ni1000 temperature sensor landis staefa QAM22 staefa t1 sensor Ni1000 temperature sensor Siemens QAM22 EN50022-35 siemens qaa PDF

    siemens air pressure sensors

    Abstract: QBE63-DP1 QBE63-DP01 landis and staefa Landis staefa Differential Pressure siemens QBE63-DP05 dp01 QBE63-DP02
    Text: 1 920 Differential pressure sensor QBE63-DP. for neutral and mildly corrosive liquids and gases Differential pressure sensor, suitable for gases and liquids, for the measurement of positive and negative pressures and pressure differentials in HVAC systems.


    Original
    QBE63-DP. EG89/336 EN50081-1, EN50081-2, EN50082-2 CA1N1920E siemens air pressure sensors QBE63-DP1 QBE63-DP01 landis and staefa Landis staefa Differential Pressure siemens QBE63-DP05 dp01 QBE63-DP02 PDF

    QVM62.1

    Abstract: QVM62 "Velocity Sensor" velocity sensor Siemens duct temperature sensor staefa Immersion sensors class 1K3 STAEFA "Air velocity Sensor" weight transducer for 10 kg
    Text: 1 1932P01 932 Air velocity sensor QVM62.1 Use This sensor is used to control the air velocity to a constant value, or to balance out pressure fluctuations supply or extract air control , or to monitor the flow in air ducts. It primarily is used for modulating fan control in primary plants to set the basic volume


    Original
    1932P01 QVM62 1932G01 1932M01 CM1N1932en QVM62.1 "Velocity Sensor" velocity sensor Siemens duct temperature sensor staefa Immersion sensors class 1K3 STAEFA "Air velocity Sensor" weight transducer for 10 kg PDF

    Siemens FR-T1/A temperature sensor

    Abstract: IEC721-3-3 staefa t1 sensor ptc 1713 siemens T1 Sensor element IEC721-3-2 Sunlight sensor siemens FR-T1 Sensor element staefa siemens fr-t1
    Text: 1 736 FR-T1/A Room temperature sensor Room sensor for HVAC systems for measurement of the air temperature • T1 measuring element • Suitable for wall mounting on all standard flush-mounting boxes FR-T1/A Technical data Application range 0 . 50 °C Measuring element


    Original
    IEC529 CA1N1736E Siemens FR-T1/A temperature sensor IEC721-3-3 staefa t1 sensor ptc 1713 siemens T1 Sensor element IEC721-3-2 Sunlight sensor siemens FR-T1 Sensor element staefa siemens fr-t1 PDF

    LG-Ni1000

    Abstract: Siemens Ni1000 temperature sensor Ni1000 temperature sensor Resistance characteristic Ni1000 ni1000 LG-Ni1000 connection QAD26 landis staefa 1802M01 1802G01
    Text: 1 Clamp-on Temperature Sensor 802 QAD26.220 Use Heating, ventilation, air conditioning and refrigeration plant. Acquisition of the medium temperature in pipes from −35 to +90 °C to provide measurement, limitation, compensation, or control. Ordering and


    Original
    QAD26 LG-Ni1000 Ni1000 LG-Ni1000 1802G01 1802M01 CM1N1802E Siemens Ni1000 temperature sensor Ni1000 temperature sensor Resistance characteristic Ni1000 ni1000 LG-Ni1000 connection landis staefa 1802M01 1802G01 PDF

    Application Papers

    Abstract: No abstract text available
    Text: Databook.fxp 1/13/99 2:10 PM Page H-13 H-13 01/99 Titles of Device Application Papers Abstracts and complete text available from InterFET upon request JFET for Completely Depleted High Resistivity Silicon V. Radeka, P. Rehak, S. Rescia Brookhaven National


    Original
    PDF

    QFA81

    Abstract: staefa SIEMENS HYGROSTAT Landis landis and staefa relative humidity sensor circuit diagram "Humidity Sensor" siemens humidity sensor
    Text: 1 Room Hygrostats 513 QFA81. for relative humidity QFA81.1 QFA81 On / off hygrostat with microswitch, with humidity sensor, with plastic texture sensing strip good linearity, wide measuring range , for the control of humidification equipment, for the control of dehumidification equipment,


    Original
    QFA81. QFA81 QFA81 CM1N1513E 1513G01 1513M01 staefa SIEMENS HYGROSTAT Landis landis and staefa relative humidity sensor circuit diagram "Humidity Sensor" siemens humidity sensor PDF

    Siemens QFM65

    Abstract: QFM65 temperature sensor Landis Ni 1000 staefa qfm65 Siemens duct temperature controller staefa t1 sensor QFM65-1 siemens hvac qfm65 STAEFA Building Management System
    Text: 1 1860P01 860 QFM65.1 Duct sensor for relative humidity and temperature Operating voltage AC 24 V Signal output DC 0.10 V for relative humidity Signal output L&S Ni 1000 passive for temperature Measurement accuracy ± 3 % r. h. within the comfort range


    Original
    1860P01 QFM65 1860M01 1860M02 CM1N1860en Siemens QFM65 temperature sensor Landis Ni 1000 staefa qfm65 Siemens duct temperature controller staefa t1 sensor QFM65-1 siemens hvac qfm65 STAEFA Building Management System PDF

    qbe*61.1

    Abstract: QBE61 landis qbe61.1-p20 polygyr QBE61.1 pressure sensor landis qbe61,1 p20 staefa Landis siemens r134a QBE61 p2
    Text: 1 Pressure Detectors 901 QBE61.1. Active pressure detector delivering a DC 0.10 V measuring signal and operating on AC 24 V. There are five different versions available, with measuring ranges between 0 and 40 bar. Application Measuring and sensing of overpressure in heating, ventilating and air conditioning


    Original
    QBE61 CM1N1901E 1901G01 1901M03E 1901M02E 1901M01 CM1N3461E qbe*61.1 landis qbe61.1-p20 polygyr QBE61.1 pressure sensor landis qbe61,1 p20 staefa Landis siemens r134a QBE61 p2 PDF

    FK-T1K1 siemens

    Abstract: Siemens temperature sensor fk-t1k2 staefa t1 sensor fk-t1k1 ptc siemens fk-t1k2 landis staefa fk t1K1 T1 Sensor element FKT1-K1 fk-t1k2 ptc 1713 siemens
    Text: 1 775 FK-T1K. Duct temperature sensor Sensor for measurement of duct air temperature in HVAC systems • T1 measuring element • Sensor probe easy to remove without dismantling sensor housing or disconnecting wiring • Fast response time • Plastic pipe between housing and


    Original
    VDI/VDE3522 M20x1 50433B CA1N1775E FK-T1K1 siemens Siemens temperature sensor fk-t1k2 staefa t1 sensor fk-t1k1 ptc siemens fk-t1k2 landis staefa fk t1K1 T1 Sensor element FKT1-K1 fk-t1k2 ptc 1713 siemens PDF

    zs1 staefa

    Abstract: siemens zs1 Siemens room temperature sensor zs1 pronto staefa pronto bus STAEFA pronto ptc 1713 siemens staefa IEC721-3-3 staefa t1 sensor
    Text: 1 656 PB-T1 Room temperature sensor Room sensor for HVAC systems, for measurement of the air temperature • T1 measuring element • Suitable for wall mounting on all standard flush-mounting boxes • Socket for the PRONTO IRC ZS1 service terminal • Trimming potentiometer for


    Original
    CA2N1656E zs1 staefa siemens zs1 Siemens room temperature sensor zs1 pronto staefa pronto bus STAEFA pronto ptc 1713 siemens staefa IEC721-3-3 staefa t1 sensor PDF

    Siemens PT100 temperature sensor

    Abstract: PT100 temperature sensor PT100 temperature sensor data sheet pt100 temperature sensor circuit diagram Siemens duct temperature sensor PT100 temperature sensor datasheet DIN43729 PT100 connected diagram sensor PT100 siemens hvac
    Text: 1 Duct temperature sensor 778 FK-TP/200 for HVAC systems Duct temperature sensor for heating, ventilation and air conditioning systems – For use with controllers with Pt100 sensor inputs – In conjunction with MULTIREG and INTEGRAL RS. Use The FK-TP/200 duct temperature sensor can be used in air ducts for heating, ventilation


    Original
    FK-TP/200 Pt100 FK-TP/200 9M426 CA1N1778E Siemens PT100 temperature sensor PT100 temperature sensor PT100 temperature sensor data sheet pt100 temperature sensor circuit diagram Siemens duct temperature sensor PT100 temperature sensor datasheet DIN43729 PT100 connected diagram sensor PT100 siemens hvac PDF

    solar sensor

    Abstract: Solar sun sensor SUN SENSOR staefa t1 sensor Siemens room temperature sensor staefa Landis siemens air temperature sensors Siemens flow sensor solar radiation sensor
    Text: 942 1 FS-T1 Solar Sensor The sensor measures the influence of solar irradiation on the heating of internal rooms. The sensor allows the flow temperature or the supply air temperature to be optimised for different sides of the building in order to reduce energy use and to


    Original
    S1-02 9D728 CA1N1942E solar sensor Solar sun sensor SUN SENSOR staefa t1 sensor Siemens room temperature sensor staefa Landis siemens air temperature sensors Siemens flow sensor solar radiation sensor PDF

    3 wire pt100 sensor

    Abstract: temperature sensor Landis Ni 1000 KTY 81-110 philips phoenix contact MCR R I 4v pt100 sensor interface with microcontroller PT100 connected diagram PT100 3 wire connected diagram cable NICR-NI thermocouple kty PT-100 signal converter pt100
    Text: MCR-T-UI -E . MCR Temperature Measuring Transducer 1. Description A universal temperature measuring transducer for resistance thermometers and thermocouples, with freely selectable temperature range, is available for the MCR-T converters (resistance thermometer: -200°C to


    Original
    PT100: 3 wire pt100 sensor temperature sensor Landis Ni 1000 KTY 81-110 philips phoenix contact MCR R I 4v pt100 sensor interface with microcontroller PT100 connected diagram PT100 3 wire connected diagram cable NICR-NI thermocouple kty PT-100 signal converter pt100 PDF

    varistor 472 SUS

    Abstract: Transient Voltage Suppression Devices, Harris RFP22N10 355a transistor landis rpf22n10 IAS25 AN9321 C150 IAS150
    Text: Harris Semiconductor No. AN9321 Harris Power February 1994 SINGLE PULSE UNCLAMPED INDUCTIVE SWITCHING: A RATING SYSTEM Author: Harold Ronan Unexpected transients in electrical circuits are a fact of life. The most potentially damaging transients enter a circuit on


    Original
    AN9321 SSD-450) varistor 472 SUS Transient Voltage Suppression Devices, Harris RFP22N10 355a transistor landis rpf22n10 IAS25 AN9321 C150 IAS150 PDF

    schematic diagram pulse shaping

    Abstract: CR-110 cremat CR-150-AC-C CR-110 charge sensitive cremat 150 CREMAT CR110 CREMAT cr-160 Landis FR cr series
    Text: CR-200 Gaussian shaping amplifier Rev. 2 : application guide General Description Equivalent circuit diagram The CR-200 is a single channel shaping amplifier, intended to be used to read out the signals from charge sensitive preamplifiers (e.g. Cremat CR-110 or equivalent). Gaussian shaping amplifiers (also known as


    Original
    CR-200 CR-110 NS-29, 200mV CR200 schematic diagram pulse shaping CR-110 cremat CR-150-AC-C CR-110 charge sensitive cremat 150 CREMAT CR110 CREMAT cr-160 Landis FR cr series PDF