Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LOCK SOLENOID Search Results

    LOCK SOLENOID Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    LM567H/B Rochester Electronics LLC LM567 - Phase-Locked Loop Visit Rochester Electronics LLC Buy
    UC2633N-G Rochester Electronics LLC UC2633 - Phase Locked Frequency Controller Visit Rochester Electronics LLC Buy
    LMX2305WG/B Rochester Electronics LLC LMX2305 - Frequency Synthesizer, PLL, 500 MHZ Visit Rochester Electronics LLC Buy
    LMX2325TMX Rochester Electronics LLC LMX2325 - PLL Frequency Synthesizer Visit Rochester Electronics LLC Buy
    UC1635J Rochester Electronics LLC UC1635 - PLL Frequency Synthesizer, BIPolar, CDIP16 Visit Rochester Electronics LLC Buy

    LOCK SOLENOID Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    circuit diagram of door lock system

    Abstract: VDE0660 IEC 947-5-1 pilot lamp UL2464-style IEC 947 EN60947 g9s OMRON D4D-j520 LC1-D mechanical interlock E76675 EN60947-5-1
    Text: R Safety-door Lock Switch D4BL Protective Doors Are Locked Until Machine Completely Stops Operation H Select mechanical lock/solenoid release or solenoid lock/mechanical release models H Dedicated release lock ensures both easy maintenance and door-unlock at


    Original
    EN60529, IEC529) EN60947-5-1 R9451050 IEC947-5-1, VDE0660 UL508 E76675 LR45746 1-800-55-OMRON circuit diagram of door lock system IEC 947-5-1 pilot lamp UL2464-style IEC 947 EN60947 g9s OMRON D4D-j520 LC1-D mechanical interlock E76675 EN60947-5-1 PDF

    lock solenoid

    Abstract: circuit diagram of door lock system solenoid lock contactor Ui 250 VAC Ithe 10A E6191 LC1D contactor wiring diagram A22E omron door lock relay solenoid lock timer D4DL-2CFA-B
    Text: D4DL Locking Safety-Door Switch Compact, Locking Safety Door Switch with Dual Key Entry H Two types in the series: Mechanical-lock H H H H H models that lock automatically when the Operation Key is inserted, and solenoid-lock models that lock when voltage


    Original
    PDF

    contactor Ui 250 VAC Ithe 10A

    Abstract: ABS-08Pg13 interlock solenoid LC1 contactor lock solenoid E76675 EN1088 EN60947-5-1 IEC529 ABS-08
    Text: Guard Lock Safety-door Switch D4BL Protective Doors Are Locked Until Machines Completely Stop Operating Two types: • Mechanical lock/Solenoid release • Solenoid lock/Mechanical release Operation Keys: • Horizontal mounting • Vertical mounting • Vertical mounting horizontal adjustable


    Original
    EN60529, IEC529) C100-E1-2A contactor Ui 250 VAC Ithe 10A ABS-08Pg13 interlock solenoid LC1 contactor lock solenoid E76675 EN1088 EN60947-5-1 IEC529 ABS-08 PDF

    circuit diagram of door lock system

    Abstract: lock solenoid OA-W1611 zb omron C300 DC-13 E76675 EN1088 EN60204-1 EN60947-5-1
    Text: Guard Lock Safety-door Switch D4GL CSM_D4GL_DS_E_3_1 Vertically Mounting Guard Lock Safety-door Switch Ideal for Limited Installation Space • Selectable Operation Key insertion direction. • Slim safety-door switch with an electromagnetic lock or unlock


    Original
    PDF

    lock solenoid

    Abstract: D4BL-2CRA EN1088 EN60947-5-1
    Text: Guard Lock Safety-door Switch D4BL Protective Doors Are Locked Until Machines Completely Stop Operating • A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety is achieved using a mechanism where the lock is only


    Original
    D-147 lock solenoid D4BL-2CRA EN1088 EN60947-5-1 PDF

    lc1-d 173

    Abstract: LC1D contactor wiring diagram solenoid lock ry-50 lapp cable current rating C107E12 LC1-D mechanical interlock EN60947-5-1 LAPP ST-PF1/2 LC1 contactor
    Text: Compact Guard-locking Interlock Safety Door Switch Polymer housing, IP65, and slow-action contacts with positive opening → . 2 versions • Mechanical lock/Solenoid release • Solenoid lock/Mechanical release Rotatable operating head provides four possible


    Original
    EN1088, EN60947-5-1 J9650736 AWB20 AWG18 C107-E1-2 1198-1M lc1-d 173 LC1D contactor wiring diagram solenoid lock ry-50 lapp cable current rating C107E12 LC1-D mechanical interlock EN60947-5-1 LAPP ST-PF1/2 LC1 contactor PDF

    D4SL-N

    Abstract: No abstract text available
    Text: Guard Lock Safety-door Switch/D4SL-N-mounting Slide Key D4SL-N / D4SL-NSK10-LK@ World's smallest Class 6-contact Guard Lock Safety-door Switch <Guard Lock Safety-door Switch D4SL-N> • Wiring time is reduced with two types of wiring methods capable of one-touch attachment and


    Original
    D4SL-NSK10-LK@ 2356-81-300/Fax: 510-608-3400/Fax: 6835-3011/Fax: 21-5037-2222/Fax: C146-E1-01 D4SL-N PDF

    Untitled

    Abstract: No abstract text available
    Text: R Locking Safety Door Switch D4DL Compact, Locking Safety Door Switch with Dual Key Entry H Slow-action contacts feature positive opening mechanism H Select mechanical lock/solenoid release or solenoid lock/mechanical release models H Operation indicator shows operation


    Original
    EN60947-5-1 J9650735 EN60947-5-1, GS-ET-19 UL508, E76675 1-800-55-OMRON PDF

    D4NL-4EFG-B

    Abstract: lock solenoid VAC s4 m8 4cfg
    Text: Safety Interlock Switches D4NL D4NL Guard Lock Safety-Door Switch • Best-selling guard lock safety-door switch available in several compact, multi-contact models • Selectable Operation Key insertion direction and adjustable mounting ensure installation flexibility


    Original
    GS-ET-19 D4NL-4EFG-B lock solenoid VAC s4 m8 4cfg PDF

    EN60947-5-1

    Abstract: GB14048 AA-76 gb14048.5 EN1088 aa77 D4BL-1CRA-A 2CRG g1224 AA78
    Text: Guard Lock Safety-door Switch D4BL Safety Interlock Switches Release Protective Cover Locks Using Controller Signals or Pushbutton Switches after the Cutting Tool Stops Moving Due to Inertia D4BL • A mechanical lock is applied automatically when the Operation


    Original
    AA-83 EN60947-5-1 GB14048 AA-76 gb14048.5 EN1088 aa77 D4BL-1CRA-A 2CRG g1224 AA78 PDF

    gb14048.5

    Abstract: D4BL-2CRB EN 60947-5-1 OMRON
    Text: Safety Interlock Switches D4BL D4BL Guard Lock Safety-Door Switch G • Release protective cover locks using controller signals or pushbutton switches after the cutting tool stops moving due to inertia • A mechanical lock is applied automatically when the Operation


    Original
    PDF

    electromagnetic lock

    Abstract: OA-W1611 lock solenoid STPF1 THERMAL Fuse m20 C300 DC-13 E76675 EN1088 EN60204-1
    Text: Guard Lock Safety-door Switch D4GL Environment-friendly Switch with Direct Opening Contacts • Contains no harmful substances, such as lead or cadmium, reducing the burden on the environment. • Slim safety-door switch with an electromagnetic lock or unlock


    Original
    C125-E1-01 75-344-7093/Fax: 1102-3M electromagnetic lock OA-W1611 lock solenoid STPF1 THERMAL Fuse m20 C300 DC-13 E76675 EN1088 EN60204-1 PDF

    circuit diagram of door lock system

    Abstract: 2ffa lock solenoid
    Text: Guard Lock Safety-door Switch D4NL CSM_D4NL_DS_E_3_2 Best-selling Guard Lock Safety-door Switch Available in Several Compact, Multi-contact Models • Selectable Operation Key insertion direction and adjustable mounting ensure installation flexibility. • Built-in switches with multiple-contact construction are


    Original
    PDF

    remote control door lock system

    Abstract: 7 digit lock code V10013 KEYPAD 4 X 4 source code KEYPAD control relays DOOR Remote key relay power door varistor code list TB1 relay RS -24V RELAY
    Text: V10013 Issued 02/2002 Programmable Access Keypad Instruction Leaflet Figures 1 3 Connecting a d.c. electric door lock to the keypad supply Connection terminals and allowed jumper positions This DIODE must be added Keypad Electric door lock 1 Power + Red LED control


    Original
    V10013 12-button 114mm remote control door lock system 7 digit lock code V10013 KEYPAD 4 X 4 source code KEYPAD control relays DOOR Remote key relay power door varistor code list TB1 relay RS -24V RELAY PDF

    VDE0660

    Abstract: IEC 947 EN60947 IEC 947-5-1 VDE0660 E76675 EN60947-5-1 IEC529 IEC947-5-1
    Text:  Safety-door Lock Switch D4BL Protective Doors Are Locked Until Machine Completely Stops Operation  Automatically locks when the operation key is inserted  Dedicated release lock ensures both easy maintenance and door-unlock at power failure  Tough aluminum die-cast unit


    Original
    EN60529, IEC529) EN60947-5-1 R9451050 IEC947-5-1, VDE0660 UL508 E76675 LR45746 GS-ET-19 IEC 947 EN60947 IEC 947-5-1 VDE0660 E76675 EN60947-5-1 IEC529 IEC947-5-1 PDF

    freescale 6812 microcontroller

    Abstract: ABS car MC34922 ABS Wheel Speed Sensor ERCOS ETK ECU MC33989 KIT33887DWBEVB electronic vehicle stability control design of hydraulic power circuit
    Text: Chassis/Safety Anti-Lock Braking Systems Overview Anti-lock braking systems ABS are designed to maintain driver control and stability of the car during emergency braking. Locked wheels slow a car but do not provide steering ability. ABS allows maximum braking to be applied while


    Original
    SG187 SG2006-5 SG2006 June2005 freescale 6812 microcontroller ABS car MC34922 ABS Wheel Speed Sensor ERCOS ETK ECU MC33989 KIT33887DWBEVB electronic vehicle stability control design of hydraulic power circuit PDF

    EN1088

    Abstract: EN60947-5-1 G-192
    Text: F502-EN2-04.book Seite 185 Dienstag, 26. Juli 2005 5:48 17 Guard Lock Safety-door Switch D4BL Protective Doors Are Locked Until Machines Completely Stop Operating • A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety is


    Original
    F502-EN2-04 C100-E2-03A-X G-196 EN1088 EN60947-5-1 G-192 PDF

    Proximity Detectors for metal detector

    Abstract: ASN E0053 83770025 ASN-E0053 83170.4 84717006 V3 Inductive proximity sensor 83161 asne0053 inductive proximity sensor
    Text: SWITCHES AND SENSORS SWITCHES AND SENSORS Safety Security Limit Switches: 838941 Solenoid Operated Metal Key Lock Limit Switches . . . . . . . . . . . . . . . . . . . . 3/64 83893 Hinged Limit Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    PDF

    LS7220

    Abstract: KEYPAD CONTROLLED DIGITAL LOCK circuit diagram LS7220 combination lock circuit ignition timing circuit diagram of sequential LED ignition lock starter solenoid A3800 LS7220-S
    Text: LSI/CSI UL LS7220 LSI Computer Systems, Inc. 1235 Walt Whitman Road, Melville, NY 11747 631 271-0400 FAX (631) 271-0405 A3800 DIGITAL LOCK FOR AUTOMOTIVE IGNITIONS OPERATING DESCRIPTION: (Refer to Figures 2, 3, 4 and 5.) When the Sense input goes high, the LS7220 is enabled. The Lock


    Original
    LS7220 A3800 LS7220-S LS7220 KEYPAD CONTROLLED DIGITAL LOCK circuit diagram LS7220 combination lock circuit ignition timing circuit diagram of sequential LED ignition lock starter solenoid A3800 LS7220-S PDF

    KEYPAD CONTROLLED DIGITAL LOCK

    Abstract: circuit diagram LS7220 Digital Keypad Combination lock A3800 LS7220 LS7220-S 3 x 4 keypad combination lock circuit
    Text: LSI/CSI UL LS7220 LSI Computer Systems, Inc. 1235 Walt Whitman Road, Melville, NY 11747 631 271-0400 FAX (631) 271-0405 A3800 DIGITAL LOCK FOR AUTOMOTIVE IGNITIONS OPERATING DESCRIPTION: (Refer to Figures 2, 3, 4 and 5.) When the Sense input goes high, the LS7220 is enabled. The Lock


    Original
    LS7220 A3800 LS7220-S KEYPAD CONTROLLED DIGITAL LOCK circuit diagram LS7220 Digital Keypad Combination lock A3800 LS7220 LS7220-S 3 x 4 keypad combination lock circuit PDF

    Untitled

    Abstract: No abstract text available
    Text: LSI/CSI UL LS7220 LSI Computer Systems, Inc. 1235 Walt Whitman Road, Melville, NY 11747 631 271-0400 FAX (631) 271-0405 A3800 DIGITAL LOCK FOR AUTOMOTIVE IGNITIONS OPERATING DESCRIPTION: (Refer to Figures 2, 3, 4 and 5.) When the Sense input goes high, the LS7220 is enabled. The Lock


    Original
    LS7220 A3800 PDF

    5301-5030

    Abstract: human detection sensors circuit switch juli dc motor C300 E76675 EN1088 EN60204-1 EN60947-5-1 Q300 OA-W1611
    Text: F502-EN2-04.book Seite 171 Dienstag, 26. Juli 2005 5:48 17 Guard Lock Safety-door Switch D4GL Environment-friendly Switch with Direct Opening Contacts • Contains no harmful substances, such as lead or cadmium, reducing the burden on the environment. • Slim safety-door switch with an electromagnetic lock or unlock mechanism.


    Original
    F502-EN2-04 C125-E2-01-X G-184 5301-5030 human detection sensors circuit switch juli dc motor C300 E76675 EN1088 EN60204-1 EN60947-5-1 Q300 OA-W1611 PDF

    acs085s

    Abstract: ACS 085s acs08 5s ACS08 ST 5S acs08-5s ST ACS 085S 0123G acs08 5S Transistor ACS108 Marking STMicroelectronics TO92
    Text: ACS108-5Sx  ASD AC LINE SWITCH MAIN APPLICATIONS AC Line switch for appliance control systems Drive of low power high inductive or resistive loads like: - solenoid, relay, valve, dispenser - micro-motor - door lock - low power lamp bulb - pump - fan


    Original
    ACS108-5Sx ACS108-5SA OT223tab IEC1000-4-5 OT223 acs085s ACS 085s acs08 5s ACS08 ST 5S acs08-5s ST ACS 085S 0123G acs08 5S Transistor ACS108 Marking STMicroelectronics TO92 PDF

    lock solenoid

    Abstract: SI-LS42WM ISO13857 interlock solenoid Z244-1 Push type solenoid switch SC22-3 GSET-19
    Text: SI-LS42 Series Safety Interlock SI-LS42 Series Safety Interlocking Switches Spring Locking and Solenoid Locking Models Features • Positive opening safety contacts IEC 60947-5-1 • Choice of two locking mechanism types: • Spring lock with energized solenoid release


    Original
    SI-LS42 10V/230V lock solenoid SI-LS42WM ISO13857 interlock solenoid Z244-1 Push type solenoid switch SC22-3 GSET-19 PDF