Text: Phoenix Contact offers a full family of modular components covering virtually all of your industrial electrical and electronic needs as well as a broad range of value-added services. CLIPLINE • DIN rail-mount terminal blocks • Marking materials and printers
|
Original
|
|
PDF
|
Airpax
Abstract: Airpax motor ATR30
Text: ATR30 Series Ignition Protected Thermal Circuit Protector FEATURES • Ignition protection compliant as per UL1500 • 5 to 35 amperes, 120/250 VAC 50/60 Hz, 50 VDC • Single pole, manual push-to-reset thermal mechanism • Reliable trip-free design • Snap-action cantilevered bimetal disc profile, with
|
Original
|
ATR30
UL1500
Airpax
Airpax motor
|
PDF
|
S072
Abstract: LR27156 LR13089
Text: Series 07 Switchable Double-Contact Break for Enhanced Interrupt Protection MP Series 07, including Models 752, 762, and 772 switchable circuit breakers, offers the advantage of a dual-function, manual/automatic disconnect with many other advanced features. The unique, saddle-shaped bimetallic mechanism provides circuit interruption
|
Original
|
UL-48
S07-8
S072
LR27156
LR13089
|
PDF
|
T1307
Abstract: No abstract text available
Text: TBHA 80-100 Bimetal Thermometer for isolated pipes Main Features For clamp-on mounting on isolated pipes Pipe diameter ¾" to 2" Class 1 according to EN 13190 Immersion tube brass Applications Water & Waste water Energy Machinery
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: TB 80-100-160 Bimetal Thermometer Main Features Multi-purpose standard thermometer Class 1 and 2 according to EN 13190 Immersion tube brass option stainless steel Immersion length 100 – 1000 mm Applications Water & Waste water Energy
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: TBX - TBW Bimetal Thermometer with conical immersion tube Main Features Conical immersion tube Class 1 according to EN 13190 Immersion tube brass Installed length 62 mm Applications Water & Waste water Energy Machinery
|
Original
|
30ges,
|
PDF
|
Untitled
Abstract: No abstract text available
Text: TBH 80-100 Bimetal Thermometer with short immersion tube Main Features For isolated pipes with max 2" diameter Class 1 according to EN 13190 Immersion tube brass option stainless steel Installed length 48, 68 or 88 mm Applications Water & Waste water
|
Original
|
|
PDF
|
CH-152-35
Abstract: cs-7s CS-7 R54 CH-152-35 Microtherm E50367 CH-15 bimetal temperature control CH15235 marking code y6
Text: caps R BIMETAL CUTOUTS Cap in standard execution, material aluminium code D R53 R54 R55 Cap for fixed mounting stainless steel (code F) Exposed bimetal cap (code FX) • Deviations from standard controls (caps, terminals, fixings) on request. • Especially for electronic applications with voltage 6…120 Vac / 6…30 Vdc and current 10…100 mA, gold crossbar contacts are available.
|
Original
|
R100U
CS710025Y
2010/March
CH-152-35
cs-7s
CS-7
R54 CH-152-35
Microtherm
E50367
CH-15
bimetal temperature control
CH15235
marking code y6
|
PDF
|
MARKING AX
Abstract: No abstract text available
Text: TK771XXA LDO, IO=150mA, BiMOS, Soft-start LDOレギュレータ、IO=150mA、BiMOS、ソフトスタート Feature Soft-start Function; ソフトスタート機能 突入電流ゼロ can be adjust the inrush current to almost zero. Fast Transient Response
|
Original
|
TK771XXA
150mA,
150mABiMOS
150mA
HSON1414-6
550mV
MARKING AX
|
PDF
|
TK772
Abstract: No abstract text available
Text: LDO, IO=300mA, BiMOS, Soft-start LDOレギュレータ、IO=300mA、BiMOS、ソフトスタート Feature Soft-start Function; ソフトスタート機能 突入電流ゼロ can be adjust the inrush current to almost zero. Fast Transient Response
|
Original
|
300mA,
300mABiMOS
300mA
HSON1820A-6
TK772XXA
500mV
-56dB
TK772
|
PDF
|
SON3024-8
Abstract: TK775XXA
Text: TK775XXA LDO, IO=500mA, BiMOS, Soft-start LDOレギュレータ、IO=500mA、BiMOS、ソフトスタート Feature Soft-start Function; ソフトスタート機能 突入電流ゼロ can be adjust the inrush current to almost zero. Fast Transient Response
|
Original
|
TK775XXA
500mA,
500mABiMOS
500mA
SON3024-8
500mV
SON3024-8
TK775XXA
|
PDF
|
TK774
Abstract: TK774XXA
Text: LDO, IO=300mA, BiMOS, Soft-start LDOレギュレータ、IO=300mA、BiMOS、ソフトスタート Feature Soft-start Function; ソフトスタート機能 突入電流ゼロ can be adjust the inrush current to almost zero. Fast Transient Response
|
Original
|
300mA,
300mABiMOS
300mA
HSON1820A-6
TK774XXA
600mV
-49dB
TK774
TK774XXA
|
PDF
|
HSOP8
Abstract: TK773 SON3024-8 HSOP8 Package TK77 HSOP-8
Text: TK773XXA LDO, IO=500mA, BiMOS, Soft-start LDOレギュレータ、IO=500mA、BiMOS、ソフトスタート Feature Soft-start Function; ソフトスタート機能 突入電流ゼロ can be adjust the inrush current to almost zero. Fast Transient Response
|
Original
|
TK773XXA
500mA,
500mABiMOS
500mA
SON3024-8
500mV
HSOP8
TK773
SON3024-8
HSOP8 Package
TK77
HSOP-8
|
PDF
|
CH-152-35
Abstract: cs-7s CS-7 cs-7 b2 bimetal cs7 E50367 R54 CH-152-35 CH15235 cs7s Ch-15
Text: caps R BIMETAL CUTOUTS Cap in standard execution, material aluminium code D R53 R54 R55 Cap for fixed mounting stainless steel (code F) Exposed bimetal cap (code FX) • Deviations from standard controls (caps, terminals, fixings) on request. • Especially for electronic applications with voltage 6…120 Vac / 6…30 Vdc and current 10…100 mA, gold crossbar contacts are available.
|
Original
|
R100U
CS710025Y
2010/Sep
CH-152-35
cs-7s
CS-7
cs-7 b2
bimetal cs7
E50367
R54 CH-152-35
CH15235
cs7s
Ch-15
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Magnetic field sensor magnet-inductive proximity sensor BIM-EM12E-Y1X • ATEX category II 1 G, Ex zone 0 ■ ATEX category II 1 D, Ex zone 20 ■ SIL2 as per IEC 61508 ■ Threaded barrel, M12 x 1 ■ Stainless steel, 1.4301 ■ ■ ■ ■ Rated operating distance 90 mm with
|
Original
|
BIM-EM12E-Y1X
DMR31-15-5
DMR31-15-5
2013-07-13T04
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: TBL 100 Bimetal Thermometer for air ducts Main Features Thermometer for direct mounting on air ducts in ventilation systems Class 1 according to EN 13190 Immersion tube brass Immersion length 165 mm Applications Energy Machinery
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Magnetic field sensor magnet-inductive proximity sensor BIM-EG08-Y1X • ATEX category II 1 G, Ex zone 0 ■ ATEX category II 1 D, Ex zone 20 ■ SIL2 as per IEC 61508 ■ Threaded barrel, M8 x 1 ■ Stainless steel, 1.4301 ■ ■ ■ ■ Rated operating distance 78 mm with
|
Original
|
BIM-EG08-Y1X
DMR31-15-5
DMR31-15-5
2013-07-13T04
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Magnetic field sensor magnet-inductive proximity sensor BIM-M12E-Y1X-H1141 • ATEX category II 1 G, Ex zone 0 ■ ATEX category II 1 D, Ex zone 20 ■ SIL2 as per IEC 61508 ■ Threaded barrel, M12 x 1 ■ Chrome-plated brass ■ ■ ■ ■ Rated operating distance 90 mm with
|
Original
|
BIM-M12E-Y1X-H1141
DMR31-15-5
DMR31-15-5
2013-07-13T04
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Magnetic field sensor magnet-inductive proximity sensor BIM-M12E-Y1X • ATEX category II 1 G, Ex zone 0 ■ ATEX category II 1 D, Ex zone 20 ■ SIL2 as per IEC 61508 ■ Threaded barrel, M12 x 1 ■ Chrome-plated brass ■ ■ ■ ■ Rated operating distance 90 mm with
|
Original
|
BIM-M12E-Y1X
DMR31-15-5
DMR31-15-5
2013-07-13T04
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Magnetic field sensor magnet-inductive proximity sensor BIM-EG08-Y1X-H1341 • ATEX category II 1 G, Ex zone 0 ■ ATEX category II 1 D, Ex zone 20 ■ SIL2 as per IEC 61508 ■ Threaded barrel, M8 x 1 ■ Stainless steel, 1.4301 ■ ■ ■ ■ Rated operating distance 78 mm with
|
Original
|
BIM-EG08-Y1X-H1341
DMR31-15-5
DMR31-15-5
2013-07-13T04
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: TB 40-63 Bimetal Thermometer Main Features Multi-purpose standard thermometer Class 1 and 2 according to EN 13190 Immersion tube stainless steel Immersion length 100 – 400 mm Applications Food & Beverage Chemical Water & Waste water
|
Original
|
|
PDF
|
MT4C1024
Abstract: micron MT4C
Text: MICRON SEMICONDUCTOR INC b3E S • hlllSMR G007544 Ô3Ô B U R N MT4C1024 L 1 MEG X 1 DRAM |U|C=RON DRAM 1 MEG x 1 DRAM FEATURES PIN ASSIGNMENT (Top View) OPTIONS MARKING • Timing 60ns access 70ns access 80ns access -6 -7 -8 • Packages Plastic DIP (300 mil)
|
OCR Scan
|
G007544
MT4C1024
512-cycle
MT4C1024)
175mW
G7555
micron MT4C
|
PDF
|
4C4001DJ
Abstract: MT16D232M
Text: MI CR ON T E C H N O L O G Y INC Q Q Q 2 UQS S biliar 3 ñE » .Jlk . 72-P ln SIM M 1-6 MT16D232M/G o to 1 37 72 72-P in Z IP (J-5) MT16D232Z MARKING • Timing 70ns access 80ns access 100ns access Packages Leadless 72 -pin SIMM Leadless72-pin SIMM (Gold)
|
OCR Scan
|
72-pin
3600mW
024-cycle
MT16D232M/G
MT16D232Z
70nsCYCLE
4C4001DJ
MT16D232M
|
PDF
|
DI 762
Abstract: No abstract text available
Text: Double-Contact Break for Enhanced Interrupt Protection MP Series 07, including M odels 752, 762, and 772 switchable circuit breakers, offers the advantage of a dual-function, manual/autom atic disconnect with many other advanced features. The unique, saddle-shaped bimetallic m echanism provides cir
|
OCR Scan
|
277VAC
/s-27
I20VAC
DI 762
|
PDF
|