Metal-Core Conduit Systems
Abstract: ASTM-A-753
Text: SERIES 75 SERIES 75 Metal-Core Conduit Systems Metal-Core Conduit Systems Hermetically sealed, flexible metal-core conduit for interconnect applications Choice of three materials: Brass, Stainless Steel, and Nickel Iron Alloy Conduit Material Choices, Material Properties, and Military Specifications
|
Original
|
|
PDF
|
Metal and Polymer Core Conduit Systems
Abstract: No abstract text available
Text: SERIES 72, 74, AND 75 Metal and Polymer Core Conduit Product Families Metal and Polymer Core Conduit Systems The flexible, lightweight alternative to standard jacketed cables Series 72 Annular Polymer Core Conduit Systems Series 74 Helical Polymer Core Conduit Systems
|
Original
|
MIL-PRF-24758/Special-Purpose
Metal and Polymer Core Conduit Systems
|
PDF
|
Introduction and Quick Selection Guide
Abstract: MIL-C-13909
Text: Series 75 Metal-Core Conduit Series 75 Flexible Metal-Core Conduit System Introduction and Quick Selection Guide The Ultimate in Highly Flexible, Crush-Proof EMI/RFI Protection Glenair Series 75 Metal-Core Conduit is a helically wound, continuous solder metal conduit, delivering the highest
|
Original
|
MIL-C-13909/A-A-52240,
MIL712-845
MIL-C-24758
Introduction and Quick Selection Guide
MIL-C-13909
|
PDF
|
Conduit Material Properties
Abstract: ASTM-A-753
Text: Series 75 Metal-Core Conduit Series 75 Flexible Metal-Core EMI/RFI Conduit Conduit Material Properties Conduit Material Choices, Material Properties, and Military Specifications Glenair Code Material Properties Applicable Military Specifications IAW A-A-52440 Covering shielded, electrical, flexible, metal
|
Original
|
|
PDF
|
series 72 annular polymer core
Abstract: No abstract text available
Text: Conduit Introduction T he first choice in the design of a flexible conduit assembly is the selection of core tubing material—whether to choose lightweight polymer convoluted tubing, or flexible metal-core conduit. Glenair Series 72 Economical annular and Series 74 High Performance helical convoluted conduit; and Series 75 Metal Core conduit all have
|
Original
|
|
PDF
|
Braided Shield and Jacket Options and Material Properties
Abstract: No abstract text available
Text: Series 75 Metal-Core Conduit Series 75 Flexible Metal-Core EMI/RFI Conduit Braided Shield and Jacket Options and Material Properties EMI/RFI Braided Shielding and Non-Metallic Fabric Overbraids D B Bronze Heavy-gauge braided bronze wire for pull (tensile) strength in metal-core conduit
|
Original
|
1930s.
Braided Shield and Jacket Options and Material Properties
|
PDF
|
fittings
Abstract: CONDUIT
Text: Series 75 Metal-Core Conduit User-Installable Fittings for Series 75 Flexible Metal-Core Conduit PRODUCT FEATURES ! Conduit Fittings for Every Interconnect Application Requirement—Connector Fittings, Transition Fittings, Bulkhead Fittings and Splice Kits
|
Original
|
|
PDF
|
103-051
Abstract: No abstract text available
Text: Conduit and Tubing System Accessories Flexible Metal-Core and Helical Polymer-Core Conduit System Accessories Special Jacketing, Braiding, Junction Boxes, Boots, Tools, and More Jacketing, Braiding, Junction Boxes, Bands, Boots and Tools for Conduit Systems
|
Original
|
|
PDF
|
entraco
Abstract: glenair fittings and entraco conduit glenair Glenair 06324 CONDUIT ASTM B 117 entraco conduit Glenair entraco MIL-C-24758 entraco fittings
Text: Conduit Systems Glenair FIRST Fittings and Adapters for Series 75 Metal-Core Conduit 750-145 & 750-147 Testing Test Requirements Test Method Testing Performed By Test Samples Interchangeability Glenair will use the same metal core, braids and jacket as Entraco* to
|
Original
|
|
PDF
|
landing gear
Abstract: tubing Convoluted
Text: Wire Protection Products for Industrial, Shipboard, Rail and Aerospace Applications Glenair Convoluted Tubing, Metal-Core Conduit, Shielding and Sealing Products are Built to Last. C onvoluted tubing and metal-core conduit materials are used in harsh-duty,
|
Original
|
MILC-24758
MIL-PRF24758A
landing gear
tubing
Convoluted
|
PDF
|
445 Glenair
Abstract: uef 160 zn 413
Text: Conduit Systems 712-460 FIRST Swivel Adapter for Glenair Conduit Fittings Mates with Series 75 Metal-Core Conduit 750-145 & 750-147 Conduit shown for reference only. To be ordered separately. 2.500 (63.5) Max 1.750 (44.5) Max Typ A Thread Typ E Conduit I.D. Typ
|
Original
|
500-Hour
445 Glenair
uef 160
zn 413
|
PDF
|
Adapters and Transitions
Abstract: No abstract text available
Text: SERIES 72, 74 & 75 ADAPTERS AND TRANSITIONS FOR METAL-CORE AND POLYMER-CORE CONVOLUTED CONDUIT SYSTEMS G lenair offers a complete wire-routing solution with conduit adapters and multi-branch transitions. Adapt conduit to popular commercial and Mil-spec connector styles like D-Subminiature, MIL-DTL-83513 Micro, and Series 79
|
Original
|
MIL-DTL-83513
MIL-DTL-38999
Adapters and Transitions
|
PDF
|
entraco
Abstract: glenair fittings and entraco conduit Glenair entraco Glenair 06324 MIL-STD-1344 mil-c-81511 Glenair mil-c-26500 MIL-C-28840 MIL-C-83723
Text: Conduit Systems Glenair FIRST Fittings and Adapters for Series 75 Metal-Core Conduit 750-145 & 750-147 General Information Swivel Design, Self-Locking Couplings, Environmental Sealing—Truly the FIRST and Last Conduit System You'll Ever Need PRODUCT FACTS
|
Original
|
717-148-AB
entraco
glenair fittings and entraco conduit
Glenair entraco
Glenair 06324
MIL-STD-1344
mil-c-81511
Glenair
mil-c-26500
MIL-C-28840
MIL-C-83723
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SERIES 72, 74 & 75 CONDUIT SYSTEM ACCESSORIES FOR FLEXIBLE METAL-CORE AND CONVOLUTED POLYMER-CORE CONDUIT G lenair offers a complete conduit system solution for even the most difficult wire routing applications. Our composite boxes and adapters solve wire routing issues in a weight-saving EMI shielded
|
Original
|
|
PDF
|
|
entraco
Abstract: glenair fittings and entraco conduit Glenair entraco entraco fittings CONDUIT
Text: Conduit Systems Glenair FIRST Fittings and Adapters for Series 75 Metal-Core Conduit 750-145 & 750-147 General Information Swivel Design, Self-Locking Couplings, Environmental Sealing—Truly the FIRST and Last Conduit System You'll Ever Need PRODUCT FACTS
|
Original
|
|
PDF
|
straight thread fitting
Abstract: No abstract text available
Text: Conduit Systems 712-461 Glenair FIRST Swivel Pipe Thread Fitting Mates with Series 75 Metal-Core Conduit 750-145 & 750-147 Conduit shown for reference only. To be ordered separately. 1.750 (44.5) Max D D Ref A Thread Typ E Conduit I.D. Typ B Fitting I.D.
|
Original
|
500-Hour
straight thread fitting
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Conduit Systems 750-145 Series 75 EMI/RFI Shielded Metal-Core Conduit Black Neoprene Jacketed for FIRST Adapters and Fittings Jacket Tin Copper Outer Shield Bronze Inner Shield Conduit A B Length 750-145-16 Product Series Basic Part No. Dash Number Table I
|
Original
|
0632Fittings
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Conduit Systems 750-147 Series 75 EMI/RFI Shielded Metal-Core Conduit Grey Neoprene Jacketed for FIRST Adapters and Fittings Jacket Tin Copper Outer Shield Bronze Inner Shield Conduit A B Length 750-147-16 Product Series Basic Part No. Dash Number Table I
|
Original
|
063ttings
|
PDF
|
tube conduit
Abstract: CONDUIT UNF 2-12UNF 712-462
Text: Conduit Systems 712-462 Glenair FIRST Swivel Stuffing Tube Fitting Mates with Series 75 Metal-Core Conduit 750-145 & 750-147 Conduit shown for reference only. To be ordered separately. 1.750 (44.5) Max .22 Ref SYMBOL S STRAIGHT E .E Ref A Thread Typ D B Fitting
|
Original
|
Dimen26
500-Hour
tube conduit
CONDUIT UNF
2-12UNF
712-462
|
PDF
|
entraco
Abstract: Glenair entraco glenair fittings and entraco conduit Glenair 06324 cross reference
Text: Conduit Systems Glenair FIRST Fittings and Adapters for Series 75 Metal-Core Conduit 750-145 & 750-147 Entraco Cross Reference Glenair and Entraco* FIRST/SEA FROST Cross Reference (Note: Both systems use the same Dimensions–which is the Key to Interchangability)
|
Original
|
|
PDF
|
EMP Conduit System
Abstract: MIL-C-24758
Text: What Ever Happened to the MIL-C-24758 EMI/EMP Conduit System? Answer: This venerable metal-core conduit wire routing and protection system has been superseded by the new MIL-PRF24578A SH standard. For all new applications, the U.S. Navy requires engineers to specify only MIL-PRF-24578A(SH) conduit, fittings and
|
Original
|
MIL-C-24758
MIL-PRF24578A
MIL-PRF-24578A
MIL-C-24758
M24758/1
M24758/2
M24758/3
M24758/4
M24758/5
EMP Conduit System
|
PDF
|
2A243
Abstract: Z21-24
Text: Conduit Systems 710-498 FIRST Bulkhead Feed-Thru Adapter Mates with Series 75 Metal-Core Conduit 750-145 & 750-147 2.500 (63.5) Max 1.750 (44.5) Max O-Ring Washer B .188 (4.8) Weather Seal C Mounting Hole A Thread Mates with Glenair Fitting Series 712-460
|
Original
|
Z21-24
2A243
Z21-24
|
PDF
|
1-12UNF
Abstract: CONDUIT UNF BD 147 dg 247 bc 147 B transistor bc 147 transistor unf data sheet 2a 13.1 CD11
Text: Conduit Systems 717-148 FIRST Special Purpose Reducer Stuffing Adapter Mates with Series 75 Metal-Core Conduit 750-145 & 750-147 Weather Seal .750 (19.1) B Thread 2.500 (63.5) .030x45° C D A Thread .188 (4.8) E .1.060 (26.9) 1.720 (43.7) 717-148-AB Product Series
|
Original
|
030x45°
717-148-AB
1-12UNF
CONDUIT UNF
BD 147
dg 247
bc 147 B transistor
bc 147 transistor
unf data sheet
2a 13.1
CD11
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MIL-PRF 24758A Glenair BlueJacket Product Line Overview MIL-PRF-24758A SH Qualified Flexible Waterproof Shielded Shipboard Conduit System Product Features Qualified to MIL-PRF-24758A(SH) Brass Metal-Core Conduit with EMI Shielding and Durable Glenair “BlueJacket” Covering
|
Original
|
4758A
MIL-PRF-24758A
MIL-C-24758
|
PDF
|