Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MIDGET FUSE Search Results

    MIDGET FUSE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCKE800NA Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE800NL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE812NA Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE812NL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, Fixed Over Voltage Clamp, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE712BNL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 13.2 V, 3.65 A, Latch, Adjustable Over Voltage Protection, WSON10 Visit Toshiba Electronic Devices & Storage Corporation

    MIDGET FUSE Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    LA60Q fuse

    Abstract: 200 Amp Fuse KLK Fuses E14721 L60030C-1C L60030C-2C LR7316 L60060C-3C KLKD Fuse
    Text: Blocks and Holders Class CC/CD and Midget Fuse Blocks 600 Volt interrupting rating of 200,000 amperes. Midget fuse voltage ratings vary and their interrupting rating may be as low as 10,000 amperes. Note that Class CC fuses may be used in Midget fuse blocks, but Midget


    Original
    L60030 L60060 LA60Q fuse 200 Amp Fuse KLK Fuses E14721 L60030C-1C L60030C-2C LR7316 L60060C-3C KLKD Fuse PDF

    Ferraz Shawmut 30311

    Abstract: Ferraz Shawmut 30312r E52283 30322 30313 30323 30323R 30310 30313R 30321R
    Text: MIDGET & CLASS CC 600 VOLT / FUSE BLOCKS 600 VOLT MIDGET AND CLASS CC FUSE BLOCKS Ferraz Shawmut Midget Fuse Blocks accommodate all 30 ampere 1-1/2” x 13/32” midget fuses. Class CC Fuse Blocks accommodate all 30 ampere Class CC fuses. A choice of box, screw, or pressure-plate


    Original
    600VAC: 200kA 30310R 30311R 30312R 30313R 30314R 30320R 30321R 30322R Ferraz Shawmut 30311 Ferraz Shawmut 30312r E52283 30322 30313 30323 30323R 30310 30313R 30321R PDF

    Untitled

    Abstract: No abstract text available
    Text: AMP-TRAP A25Z-2 1-1/2” X 13/32” A25Z “Type 2” Amp-trap midget fuses are primarily used for semiconductor protection. They have a 300 volt rating and are highly current-limiting fuses, with midget dimensions. Not for Branch Circuit Protection . MIDGET FUSES


    Original
    A25Z-2 300VAC, 100kA A25Z1-2 A25Z2-2 A25Z3-2 A25Z4-2 A25Z5-2 PDF

    Untitled

    Abstract: No abstract text available
    Text: General Purpose US US Fuses General Purpose Fuses Midget Fuses 10x38 US Fast Acting ATM Amp-trap midget fast-acting ATM fuses are rated 600 volts AC, with a 100kA interrupting rating. These ratings give the ATM a wide range of applications not covered by other midget fuses. In


    Original
    10x38 100kA ATM1/10 ATM2/10 ATM10 ATM12 ATM15 ATM20 ATM25 ATM30 PDF

    SOLAR INVERTER 1000 watts circuit diagram

    Abstract: solar power inverter Circuit diagram solar panel wiring diagram solar power circuit diagram solar inverter circuit small solar panel circuit diagram solar cells circuit diagram solar power inverter solar panel circuit diagram dc ac inverter solar
    Text: Your Safest Connection for Solar Power Circuit Protection A B D C Circuit Protection Components for Solar Power A Combiner Box B Inverter 600VDC midget fuses 1000VDC midget fuses 600VDC class CC fuses 600VDC class R fuses UltraSafe class CC & midget fuse holders


    Original
    600VDC 1000VDC 700VDC 600VAC BR-SOLAR-O02 SOLAR INVERTER 1000 watts circuit diagram solar power inverter Circuit diagram solar panel wiring diagram solar power circuit diagram solar inverter circuit small solar panel circuit diagram solar cells circuit diagram solar power inverter solar panel circuit diagram dc ac inverter solar PDF

    Untitled

    Abstract: No abstract text available
    Text: ATM Fast-Acting Midget Fuses Amp-Trap midget fast-acting ATM fuses are rated 600 volts AC and DC, with a 100kA interrupting rating. These ratings give the ATM a wide range of applications not covered by other midget fuses. In addition, ratings of 30/35, 30/40 and 30/50


    Original
    100kA ATM2/10 600VAC E33925 10x38mm) USFM10I PDF

    Z201916

    Abstract: L212691 Y200857 X211137 A217787 ATM20 ATM5 Fuses for Capacitors B222549 fuses
    Text: General Purpose US US Fuses General Purpose Fuses Midget Fuses 10x38 US Fast Acting ATM Amp-trap midget fast-acting ATM fuses are rated 600 volts AC, with a 100kA interrupting rating. These ratings give the ATM a wide range of applications not covered by other midget fuses. In


    Original
    10x38 100kA 600VAC, 600VDC, GPUS69 ATM1/10 ATM2/10 ATM10 ATM12 Z201916 L212691 Y200857 X211137 A217787 ATM20 ATM5 Fuses for Capacitors B222549 fuses PDF

    KLKD30

    Abstract: KLKD002 KLKD030 LR29862 KLKD Fuse fuse 10x38
    Text: Solar-Rated 10x38 mm Midget Fuse KLKD 10x38 mm Midget Fuse Product Features • UL Listed 600 Vdc maximum • 50,000 Adc interrupting rating • High performance in compact 10x38 mm midget size • Touch-safe DIN-rail mount holder available • PCB leaded version available in select amperages


    Original
    10x38 KLKD002 KLKD030 KLKD030R KLKD002 KLKD030 KLKD30 LR29862 KLKD Fuse fuse 10x38 PDF

    A25Z-2

    Abstract: A25Z10-2 Ferraz ShawmuT AMPTRAP Ferraz Ferraz Shawmut Ferraz shawmut 100kA A25Z A25Z30-2 A25Z15-2 a25z10
    Text: AMP-TRAP A25Z-2 1-1/2” x 13/32” MIDGET FUSES A25Z “Type 2” Amp-trap midget fuses are primarily used for semiconductor protection. They have a 300 volt rating and are highly current-limiting fuses, with midget dimensions. Not for Branch Circuit Protection .


    Original
    A25Z-2 300VAC, 100kA A25Z1-2 A25Z2-2 A25Z3-2 A25Z4-2 A25Z5-2 A25Z-2 A25Z10-2 Ferraz ShawmuT AMPTRAP Ferraz Ferraz Shawmut Ferraz shawmut 100kA A25Z A25Z30-2 A25Z15-2 a25z10 PDF

    ATM Fuses

    Abstract: ATM5 ATM-18 ATM30 ATM1 ATM15 ATM8 ATM20 ATM6 fuse ATM12
    Text: AMP-TRAP ATM 1-1/2” x 13/32” MIDGET FUSES Amp-Trap midget fast-acting ATM fuses are rated 600 volts AC and DC, with a 100kA interrupting rating. These ratings give the ATM a wide range of applications not covered by other midget fuses. In addition, ratings of 30/35, 30/40 and


    Original
    100kA ATM1/10 ATM2/10 ATM10 ATM12 ATM15 ATM20 ATM25 ATM30 ATM30/35* ATM Fuses ATM5 ATM-18 ATM30 ATM1 ATM15 ATM8 ATM20 ATM6 fuse ATM12 PDF

    800-TEC-FUSE

    Abstract: SPF030
    Text: Solar Rated Midget Fuse SPF Series 1000VDC Solar Fuse Product Features • UL Recognized 1000VDC maximum • 13 ampere ratings for flexible design • 20,000 kA interrupting rating • High performance in compact midget size • RoHS compliant and lead free


    Original
    1000VDC E10480 1000VDC SPF002 SPF030 SPF030R 800-TEC-FUSE 800-TEC-FUSE SPF030 PDF

    Untitled

    Abstract: No abstract text available
    Text: Technical Data 1157 Effective April 2014 Supersedes July 2013 Compact Circuit Protector CCP UL Class CC, CF (CUBEFuse ), Midget and IEC 10x38mm DIN-Rail Fused Disconnect Switches Contents Description Page Description Page 1-, 2- and 3-Pole — Class CC, Midget


    Original
    10x38mm BU-SB14181 PDF

    Untitled

    Abstract: No abstract text available
    Text: OTM Fast-Acting Midget Fuses One-time OTM midget fuses provide low-cost protection for 250 volt AC general purpose lighting, heating, control circuits, etc. where time-delay is not required. Not for Branch Circuit Protection . Features/Benefits: Highlights:


    Original
    250VAC 250VAC OTM10 OTM15 OTM20 OTM25 OTM30 PDF

    Untitled

    Abstract: No abstract text available
    Text: POWR-GARD Blocks and Holders Datasheet Class CC and Midget Fuse block Accessories FBDIN1 Rail Adapter Dimensions Inches Features/Benefits • DIN Rail adaptor for 30 A Midget, Class CC and Class G fuse blocks • Patented design with no tools necessary for installation


    Original
    SPL001 L60030C99 L60030M com/spl001 PDF

    A25Z-2

    Abstract: A25Z10-2 ferraz fuses 6.9 G212687 G216252 S214721
    Text: Semiconductor A (AC)fuses Semiconductor fuses American Round Fuses Other American Fuses A25Z-2 Semiconductor Protection Fuses A25Z “Type 2” Amp-trap midget fuses are primarily used for semiconductor protection. They have a 300 volt rating and are highly current-limiting fuses, with midget dimensions.


    Original
    A25Z-2 300VAC, 100kA A25Z1-2 A25Z2-2 A25Z3-2 A25Z4-2 A25Z5-2 A25Z-2 A25Z10-2 ferraz fuses 6.9 G212687 G216252 S214721 PDF

    Untitled

    Abstract: No abstract text available
    Text: GGU Fast-Acting Midget Fuses 125 volt AC rated GGU fuses have midget fuse dimensions 1-1/2” long x 13/32” diameter . 20A-30A ratings have ceramic bodies, allowing use in higher ambient temperature conditions than other similar fuses. (Not for Branch Circuit Protection).


    Original
    0A-30A 0-30A 125VAC 125VaSafeâ GGU10 GGU15 GGU20 GGU30 10x38mm) PDF

    FUSE

    Abstract: SPL001
    Text: Class CC and Midget Fuse Block Accessories DIN Rail Adapters and Cover Pullers .750" 1.490" .770" .576" .484" .670" 1.360" DIN Rail Adapter — FBDIN1 FBDIN1 is for use with 30A Midget, Class CC and Class G fuse blocks. The patented design permits snap-mounting of


    Original
    SPL001 L60030C L60030M FUSE SPL001 PDF

    OTM3

    Abstract: OTM2 OTM4 E33925 OTM1 OTM10 OTM25 OTM15 fuse 10KA OTM5
    Text: ONE TIME OTM 1-1/2” x 13/32” MIDGET FUSES One-time OTM midget fuses provide lowcost protection for 250 volt AC general purpose lighting, heating, control circuits, etc. where time delay is not required. Not for Branch Circuit Protection . HIGHLIGHTS:


    Original
    250VAC 250VAC, E33925 OTM10 OTM15 OTM3 OTM2 OTM4 E33925 OTM1 OTM10 OTM25 OTM15 fuse 10KA OTM5 PDF

    Fuse Blocks

    Abstract: No abstract text available
    Text: POWR-GARD Blocks and Holders Datasheet Class CC and Midget Fuse block Accessories FBDIN1 Rail Adapter Dimensions Inches Features/Benefits • DIN Rail adaptor for 30 A Midget, Class CC and Class G fuse blocks • Patented design with no tools necessary for installation


    Original
    SPL001 SPL001 DSPL001 SPL001PCB 0SPL0001T 0SPL0001H DSPL0001Z DSPL0001H Fuse Blocks PDF

    6JX10

    Abstract: ferraz shawmut fuse 10x38 B082686J 6JX30 E082689 6JX2 6JX3 6JX5 F082805J 6jx12
    Text: General Purpose General Purpose US Fuses US Fuses Midget Fuses 10x38 US Fast Acting 6JX 600VAC - 500VDC 100000 A.I.R Current limiting Ferraz Shawmut 6JX Midget Fuses are recommended for applications requiring very precise operating characteristics and where high available fault currents demand high interrupting


    Original
    10x38 600VAC 500VDC C079651J D079652J K079681J L079682J T082334J R083068J Q079686J 6JX10 ferraz shawmut fuse 10x38 B082686J 6JX30 E082689 6JX2 6JX3 6JX5 F082805J 6jx12 PDF

    ATQ Fuses

    Abstract: ATQ Fuses 5 atq20 ATQ8 ATQ15 ATQ1 R213708 ATQ2 E215238 B211141
    Text: General Purpose US US Fuses General Purpose Fuses Midget Fuses 10x38 US Time Delay ATQ 500VAC (TD) Amp-trap ATQ midget time-delay fuses are rated a full 500 volts AC with 42 ampere ratings from 1/10 to 30A. They are an excellent choice for supplemental


    Original
    10x38 500VAC R219872 R219343 F222553 Q218307 X223074 C200861 P216259 ATQ Fuses ATQ Fuses 5 atq20 ATQ8 ATQ15 ATQ1 R213708 ATQ2 E215238 B211141 PDF

    E14721

    Abstract: No abstract text available
    Text: POWR-GARD Blocks and Holders Datasheet LF Series Class cc/cd and midget 10x38 Fuse blocks 600 V Specifications Voltage Rating 600 Vac/dc Ampere Ratings L600M Midget (10x38): 30 A L600C Class CC: 30 A LFC Class CD: 60 A Dielectric strength 1200 V minimum


    Original
    10x38) L600M L600C L600M: E14721) LR7316) L600C: E14721 PDF

    A6Y6 Type 2

    Abstract: A6Y10-2B 1015a
    Text: General Purpose General Purpose US Fuses US Fuses Midget Fuses 10x38 US Fast Acting A6Y-2B A6Y “Type 2B” Amp-trap midget fuses are fast acting on short circuits, yet have sufficient time delay to offer supplemental protection for small motors, transformers, and control circuits.


    Original
    10x38 3-2/10-15A) 500VAC, A6Y6/10-2B A6Y1-6/10-2B A6Y3-2/10-2B A6Y10-2B A6Y12-2B A6Y15-2B Y222546 A6Y6 Type 2 1015a PDF

    Untitled

    Abstract: No abstract text available
    Text: TRM Time-Delay Midget Fuses Tri-Onic TRM time-delay midget fuses are rated 250 volts AC and are offered in ampere ratings from 1/10 to 30A. They have 12 seconds time-delay at 200% rating to provide supplemental protection of small motors, small transformers and other


    Original
    250VAC TRM15 TRM20 TRM3/10 TRM25 TRM4/10 TRM1-4/10 TRM2-8/10 TRM30 10x38mm) PDF