Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MOVING COIL VOLTMETER Search Results

    MOVING COIL VOLTMETER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DFE2016CKA-1R0M=P2 Murata Manufacturing Co Ltd Fixed IND 1uH 1800mA NONAUTO Visit Murata Manufacturing Co Ltd
    LQW18CN55NJ0HD Murata Manufacturing Co Ltd Fixed IND 55nH 1500mA POWRTRN Visit Murata Manufacturing Co Ltd
    LQW18CNR56J0HD Murata Manufacturing Co Ltd Fixed IND 560nH 450mA POWRTRN Visit Murata Manufacturing Co Ltd
    DFE322520F-2R2M=P2 Murata Manufacturing Co Ltd Fixed IND 2.2uH 4400mA NONAUTO Visit Murata Manufacturing Co Ltd
    LQW18CN4N9D0HD Murata Manufacturing Co Ltd Fixed IND 4.9nH 2600mA POWRTRN Visit Murata Manufacturing Co Ltd

    MOVING COIL VOLTMETER Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    voltmeters panel SD-38 class 2.0

    Abstract: "moving coil" CLASS 2.0 SD-38
    Text: Panel Meters Moving Coil Meters Specifications: Movement : Moving coil type. Measuring range : 90°. Pointer : 0.4m/m. Pointer colour : Red/Black. Pointer position : Left zero hand. Scale : Aluminum. Coil resistance :1500Ω ±10%. Current sensitivity : DC 100uA ±2.5%.


    Original
    100uA voltmeters panel SD-38 class 2.0 "moving coil" CLASS 2.0 SD-38 PDF

    voltmeters panel SD-38 class 2.0

    Abstract: CLASS 2.0 SD-38 "moving coil"
    Text: Panel Meters Moving Coil Meters Specifications: Movement : Moving coil type. Measuring range : 90°. Pointer : 0.4m/m. Pointer colour : Red/Black. Pointer position : Left zero hand. Scale : Aluminum. Coil resistance :1500Ω ±10%. Current sensitivity : DC 100uA ±2.5%.


    Original
    100uA voltmeters panel SD-38 class 2.0 CLASS 2.0 SD-38 "moving coil" PDF

    product catalogue

    Abstract: eltime.co Schrack RA 450 024 FE96MCA BS7626 FE72MIA
    Text: >> moving iron >> rectified moving coil >> frequency meters >> phase sequence indicators >> null voltmeters >> wattmeters Product Catalogue >> varmeteers >> power factor meters Global Suppliers of Measurement and Protection Equipment for Industry >> electromechanical hourmeters


    Original
    PDF

    AC ammeter and ct diagram

    Abstract: hobut 240V A.C. to 30V D.C. transformer bs89 digital wattmeter circuit ammeters with burden moving coil ammeter D96SD d72mc AC digital voltmeter and ammeter
    Text: DIN RANGE PANEL METERS DESCRIPTION Available with moving iron or moving coil movements for a.c. or d.c. use, these DIN panel meters have been supplied worldwide and are recognised for their quality and value. Standard scales or customised dials can be offered.


    Original
    IEC51 DIN72 DIN96 AC ammeter and ct diagram hobut 240V A.C. to 30V D.C. transformer bs89 digital wattmeter circuit ammeters with burden moving coil ammeter D96SD d72mc AC digital voltmeter and ammeter PDF

    bs89

    Abstract: MOVING IRON PANEL METER analog voltmeter "moving coil" MOVING MOVING IRON METER transformer 1mA moving coil panel
    Text: Indirect reading ammeters and voltmeters X AC moving iron DC moving coil DIN standard instruments in 48, 72 and 96mm square cases. Conforming to BS89, IEC 51, VDE 0410 and DIN 43700, 43701 • 72 and 96 sizes supplied without scale ■ For shunt, current transformer or analogue


    Original
    RU487296 000/Volt bs89 MOVING IRON PANEL METER analog voltmeter "moving coil" MOVING MOVING IRON METER transformer 1mA moving coil panel PDF

    IEC51

    Abstract: 96X96mm IP52
    Text: 240° DIN RANGE PANEL METERS DESCRIPTION 96 X 96mm and 72 X 72mm DIN panel meters employing moving coil movements, with 240° scales. All products are supplied with terminal covers and are manufactured to IEC51. APPLICATION Used widely in the panel building industry


    Original
    IEC51. 45/65Hz, 220/240V 300mA IEC51 96X96mm IP52 PDF

    d72mc

    Abstract: D48MC D96MC DIN43700 ammeters DIN-48 DIN48 m4 screw moving coil panel d96m
    Text: MOVING COIL Types: D48MC, D72MC, D96MC. Accuracy: Class 1.5. DC Ratings: 100µA to 50A direct connected D48MC - 40A max 4-20mA, 1mA or 20mA transducer operated. 50mV to 600V direct connected. 50mV to 300mV shunt operated. AC Ratings: Rectifier types available for a.c. use (mean


    Original
    D48MC, D72MC, D96MC. D48MC 4-20mA, 300mV 150mV 1000/V) DIN72, DIN48. d72mc D96MC DIN43700 ammeters DIN-48 DIN48 m4 screw moving coil panel d96m PDF

    PST2430B

    Abstract: No abstract text available
    Text: POWER SUPPLIES Flex 6005A 1 Phase Flex 6012A (1 Phase) Flex 17048A (1 Phase) Flex 28048A (1 Phase) Flex 17012A (1 Phase) Flex 50048A (1 Phase) Flex 28012A (1 Phase) Flex 9024B (2 Phase) Flex 6024A (1 Phase) Flex 17024B (2 Phase) Flex 28024B (2 Phase) Flex 17024A


    Original
    7048A 8048A 7012A 0048A 8012A 9024B 17024B 28024B 7024A 50024B PST2430B PDF

    Omron TV5

    Abstract: jis C5003 MBB relay omron relay electromechanical humidity C4530 C5003 relay contact wear failure analysis 78A5A
    Text: General-purpose Relay Glossary This section defines the terms that are used in catalogs. • General Relay Terms ■ Contacting section Relay Contact configuration A device designed to cause a sudden, predicted change in a single or multiple electrical output circuits when certain conditions are


    Original
    PDF

    3 phase 3 wire ammeter wiring

    Abstract: crompton ammeter Analogue DC Ammeter circuit ANSI C39.1 frequency meter crompton dc ammeter electronic watt-meter circuit diagrams MOVING IRON METER transformer 3-phase 220 volts to 380v 244-14L
    Text: 240 Series DIN Panel Meters An extensive range of 48, 72, 96 and 144mm DIN style panel meters offering measurement of all electrical and electronic parameters. Meters are shock resistant and vibration proof and supplied with terminal covers. A selection of slide in dials


    Original
    144mm 3 phase 3 wire ammeter wiring crompton ammeter Analogue DC Ammeter circuit ANSI C39.1 frequency meter crompton dc ammeter electronic watt-meter circuit diagrams MOVING IRON METER transformer 3-phase 220 volts to 380v 244-14L PDF

    digital 3 phase voltmeter and ammeter

    Abstract: AC digital voltmeter and ammeter 3 phase analog voltmeter and ammeter AC digital voltmeter digital 3 phase voltmeter WATT and ammeter analog panel meter digital phase voltmeter and ammeter GR72-3DV digital Ammeter circuit VAR meter
    Text: com.greegoo.www Greegoo Elextric Co.,Ltd. 2007 Panel Meters Introduction Panel Meters and Accessories 1- Digital Panel Meter Specification: HCD19 - □ □- □ X □ The instruments comply with IEC51 Over load 1. Product code 2. Input Signal Mode 4-AC signal input 5-DC signal


    Original
    HCD19 IEC51 4--48X48 5--96X48 7--72X72 9--96X96 GR96-3PF3 GR96-3PF1 96x96 digital 3 phase voltmeter and ammeter AC digital voltmeter and ammeter 3 phase analog voltmeter and ammeter AC digital voltmeter digital 3 phase voltmeter WATT and ammeter analog panel meter digital phase voltmeter and ammeter GR72-3DV digital Ammeter circuit VAR meter PDF

    h48 diode zener

    Abstract: Zener diode H48 DPM970 D225 Diode zener OEM24L MB111 SAE TRANSFORMER CT 1A lcd voltmeters M850-MP1 hobut
    Text: 2279 Technical portal and online community for Design Engineers - www.element-14.com Panel Meters Page 4 to 20mA Process Indicators . . . . . . . . . . . . . . . Ammeter Shunts . . . . . . . . . . . . . . . . . . . . . . . . . . . Current Transformers CT’s . . . . . . . . . . . . . . . .


    Original
    element-14 h48 diode zener Zener diode H48 DPM970 D225 Diode zener OEM24L MB111 SAE TRANSFORMER CT 1A lcd voltmeters M850-MP1 hobut PDF

    077-08AA-LSSU-C6

    Abstract: AC digital voltmeter diagram Analogue Meter diagram AC digital voltmeter and ammeter 077-16FU-LS
    Text: 070 Series ANSI Switchboard Meters Approvals UL Approved File No: E87815 This high quality range of Switchboard instruments complies with the American specification ANSI-C39.1 1981 accuracy class 1. Available in two case sizes, their rugged design characteristics


    Original
    E87815 ANSI-C39 LR99712-1 077-DW9 77-14A, 077-14L, 077-14D, 077-14G, 077-14H 077-08AA-LSSU-C6 AC digital voltmeter diagram Analogue Meter diagram AC digital voltmeter and ammeter 077-16FU-LS PDF

    Digital Panel Meter PM 428

    Abstract: transformer 3-phase 220 volts to 380v electronic watt-meter circuit diagrams 0-500V AC voltmeter diagram free digital AC Ammeter CT including digital wattmeter circuit 12 volt dc to 220 volt 3-phase 400 Hz 3000 watts dc voltmeter circuit diagrams 0-300v AC AMMETER METER phase sequence indicator
    Text: 070 Series ANSI Switchboard Meters This high quality range of Switchboard instruments complies with the American specification ANSI-C39.1 1981 accuracy class 1. Available in 41/2" and 83/4" case sizes, their rugged design characteristics suit the most demanding of environmental


    Original
    ANSI-C39 077-DW9 077-DXL 077-DXU 077-DP5 077-DP7 077-DZL 077-DI2, 077-DIA 077-DIB, Digital Panel Meter PM 428 transformer 3-phase 220 volts to 380v electronic watt-meter circuit diagrams 0-500V AC voltmeter diagram free digital AC Ammeter CT including digital wattmeter circuit 12 volt dc to 220 volt 3-phase 400 Hz 3000 watts dc voltmeter circuit diagrams 0-300v AC AMMETER METER phase sequence indicator PDF

    OMRON lzn2

    Abstract: RELAY OMRON LZN2 RELAY OMRON LZN G5Y-154P lzn2 OMRON RELAY LZN omron type LZN eac reed relay omron relay lzn2 Omron LZN
    Text: Omron A5 Catalogue 2007 1-282 11/9/06 10:16 am Page 10 Technical Information – Relays • Relay Classification Model G4W Discrete Enclosure Ratings Features Unsealed Designed for manual soldering G2R Flux protection Design inhibits flux intrusion into the casing fro


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: ANALOGUE INSTRUMENTS nalogue Analogue instruments ANALOGUE INSTRUMENTS ANALOGUE INSTRUMENTS Analogue instruments CONTENTS GENERAL FEATURES . AI-04


    Original
    AI-04 AI-05 AI-60 PDF

    Ansi Switchboard Meters

    Abstract: 077-12PA-P2C6
    Text: Crompton Instruments ANSI Switchboard Meters www.crompton-instruments.com Crompton Instruments ANSI SWITCHBOARD METERS An extensive range of analog and digital/analog meters in the 4½" ANSI case style. Meters utilize a robust pivot and jewel movement design, and provide 1% accuracy for all RMS AC


    Original
    PDF

    lzn2

    Abstract: RELAY OMRON LZN g5y-154p RELAY OMRON LZN2 OMRON lzn2 eac reed relay omron type LZN coil eddy current 220 ac INVERTER without transformer for iron weld Matsua Miniature Relay s4 5v
    Text: Introduction Introduction Back Technical Information Relay Classification Model Mounting Discrete Enclosure Ratings Features Unsealed Designed for manual soldering. G2R Flux protection Designed inhibits flux intrusion into the casing from the terminals during soldering.


    Original
    PDF

    PH ON 4307

    Abstract: 10 amp 12 volt solar charger circuits
    Text: Power Distribution Panels Circuit Breaker Panels Waterproof Switch Panels Instrument Panels Box-Build Assemblies Enclosure Assemblies Mounting Frames Parts & Components Company Information About Paneltronics Family owned and operated since 1979, Paneltronics is an


    Original
    PDF

    westinghouse Kp 241

    Abstract: westinghouse Kx 241 dc ammeter circuit diagrams application of wattmeter ac voltmeter circuit diagrams KX-241 westinghouse KA 241 dc voltmeter circuit diagrams WESTINGHOUSE Switchboard KI-241
    Text: 4 1/2 and 8 3/4-inch Rectangular, Type K-241 and 261, For Commercial and Military Service Application Type K-241 & 261 instruments have been designed to achieve the ultimate in reliability and performance. Instruments of this class are recommended for use on electric utility


    Original
    K-241 K-241 MIL-M-16034A MIL-S-901C) westinghouse Kp 241 westinghouse Kx 241 dc ammeter circuit diagrams application of wattmeter ac voltmeter circuit diagrams KX-241 westinghouse KA 241 dc voltmeter circuit diagrams WESTINGHOUSE Switchboard KI-241 PDF

    linear motion transducer

    Abstract: TRANSDUCER OMEGA pressure
    Text: THE LD100, A FAST LINEAR DISPLACEMENT TRANSDUCER Early in 1983, development of an electrically non-contacting linear displacement transducer LDT for use in reciprocating heater engine research began. LVDT’s in this service were unsatisfactory for several reasons. They frequently


    Original
    LD100, linear motion transducer TRANSDUCER OMEGA pressure PDF

    MOVING IRON PANEL METER

    Abstract: MOVING IRON METER "moving coil" coil dc MOVING IRON
    Text: RANGES AVAILABLE. AMMETERS 1A or 5A CT OPERATED UP TO 40A DIRECT CONNECTED DIRECT CONNECTED AC MOVING IRON AC MOVING IRON AC MOVING IRON DIRECT CONNECTED DIRECT CONNECTED DIRECT CONNECTED DC MOVING COIL DC MOVING COIL DC MOVING COIL UP TO 0/40/80A 0/1 mA 0/20mA


    OCR Scan
    0/40/80A 0/20mA 4/20mA 45/55HZ 45/65HZ MOVING IRON PANEL METER MOVING IRON METER "moving coil" coil dc MOVING IRON PDF

    Kyoritsu KM-66

    Abstract: Kyoritsu KM-86A Kyoritsu KM-48 Kyoritsu KM-66 KM-106 KM-118 km66 AC Transformer 50A 100V KM106
    Text: K M Seríes All models can be supplied with colour plate 6 colour variations available on lower section of front cover. Designed also for behind the panel mounting. Available from this series are model KM -48, KM -66, KM -86A, KM-106 and KM-118. Moving Coil (M.C.) & Moving Iron (M.I.) Types available.


    OCR Scan
    KM-48, KM-66, KM-86A, KM-106 KM-118. KM-86A KM-48 Kyoritsu KM-66 Kyoritsu KM-86A Kyoritsu KM-48 Kyoritsu KM-66 KM-118 km66 AC Transformer 50A 100V KM106 PDF

    EW-40

    Abstract: EW-60 moving coil panel 3q MULTIPLIER EW60 voltmeters panel SD-38 class 2.0
    Text: E W Series Designed to minimize panel space requirements. Model EW -40 and EW -60 are available from this edgewise series. Internal core magnet type movement is not affected be external magnetic fierd and steel. wu/ita Type Ammeters •Voltmeters AC Ammeters ■Voltmeters


    OCR Scan
    EW-40 EW-60 EW-60 EW-40 moving coil panel 3q MULTIPLIER EW60 voltmeters panel SD-38 class 2.0 PDF