Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    NAMUR FLOAT Search Results

    NAMUR FLOAT Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TMPM4GQF15FG Toshiba Electronic Devices & Storage Corporation Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP144-2020-0.50-002 Visit Toshiba Electronic Devices & Storage Corporation
    TMPM4GRF20FG Toshiba Electronic Devices & Storage Corporation Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP176-2020-0.40-002 Visit Toshiba Electronic Devices & Storage Corporation
    TMPM4KMFWAFG Toshiba Electronic Devices & Storage Corporation Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP80-1212-0.50-003 Visit Toshiba Electronic Devices & Storage Corporation
    TMPM4MMFWAFG Toshiba Electronic Devices & Storage Corporation Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP80-1212-0.50-003 Visit Toshiba Electronic Devices & Storage Corporation
    TMPM4NQF10FG Toshiba Electronic Devices & Storage Corporation Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP144-2020-0.50-002 Visit Toshiba Electronic Devices & Storage Corporation

    NAMUR FLOAT Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: Extract from the online catalog MINI MCR-SL-NAM-2RNO-SP Order No.: 2810269 Configurable NAMUR switching amplifier for proximity sensors, floating switching contacts and switching contacts with resistance circuit. On


    Original
    PDF IF-2009)

    IEC 60947-5-6

    Abstract: namur standard LFL-Z231 60947-5-6 LFL-Z131 float switch LIMIT SWITCH namur application 68307 Pepperl Fuchs kfd2 LFL-Z32
    Text: Pepperl+Fuchs offers a wide range of float switches: Application - suitable for use up to Ex-area zone 1 - mercury-free switching element - nominal voltage, 8 V per EN 60947-5-6 NAMUR - connected through a transformer isolated barrier (i.e. KFD2-SR.) - mercury-free switching element


    Original
    PDF

    60947-5-6

    Abstract: No abstract text available
    Text: Extract from the online catalog PI-EX-NAM/RNC-NE Order No.: 2835367 Ex-i binary input: NAMUR isolation amplifiers. For operating proximity sensors and switches in Ex areas. The binary signals are transmitted


    Original
    PDF IF-2002) 60947-5-6

    IEC 60947-5-6

    Abstract: LIMIT SWITCH namur application DN100 PN16 KEMA Flow switch CA3 DN40 EN 10204 3.1 DN100-PN40 DN80-PN40 10204 3.1b material certificate namur float
    Text: Vibration limit switch Dimensions Ø85 max. 76 L ~25 max. 140 Vibracon LVL-M with plastic housing and process connection Goo 17.5 max. 65 Ø80 max. 60 Vibracon LVL-M NAMUR max. 40.7 max. 173 Vibracon LVL-M with aluminium housing and process connection with flange


    Original
    PDF 4435/316L 4435/316L, mm/115 IEC 60947-5-6 LIMIT SWITCH namur application DN100 PN16 KEMA Flow switch CA3 DN40 EN 10204 3.1 DN100-PN40 DN80-PN40 10204 3.1b material certificate namur float

    Catalog Sensors for Process Applications

    Abstract: NCB1.5-8GM25-N0 5M
    Text: FACTORY AUTOMATION CATALOG SENSORS FOR PROCESS APPLICATIONS 1FQQFSM 'VDIT°6OCFBUBCMFGPSRVBMJUZBOEDIPJDF 8F BSF B MFBEJOH NBOVGBDUVSFS PG JOEVTUSJBM TFOTPST BOE TFOTPS TZTUFNT 


    Original
    PDF 199003130E Catalog Sensors for Process Applications NCB1.5-8GM25-N0 5M

    Galvanic

    Abstract: Isolation Amplifiers "Isolation Amplifiers" Namur isolating switching amplifier
    Text: Extract from the online catalog UM122-FLK16/EX-MB/8 Order No.: 2968467 Ex-module carrier, intrinsically safe, for accommodating 8 Process Interface modules PI-Ex. . Commercial data


    Original
    PDF UM122-FLK16/EX-MB/8 IF-2009) UM122-FLK16/EX-MB/8 Galvanic Isolation Amplifiers "Isolation Amplifiers" Namur isolating switching amplifier

    namur ne43

    Abstract: Ni100 sensor Pt100 transmitter 4.20 mA PR 5131A IEC584 pTC-10 ohm PT100 3 wire connected diagram namur NE 43 pt100 atex NE43
    Text: PRetrans 5131 2-WIRE PROGRAMMABLE TRANSMITTER Input for RTD, TC, mV, linear resistance, mA, and V 3.75 kVAC galvanic isolation 4.20 mA loop output 1- and 2-channel versions ATEX Ex version DIN rail mounting Application: Electronic temperature measurement with resistance


    Original
    PDF 5131B namur ne43 Ni100 sensor Pt100 transmitter 4.20 mA PR 5131A IEC584 pTC-10 ohm PT100 3 wire connected diagram namur NE 43 pt100 atex NE43

    namur ne43

    Abstract: Ni100 sensor LIMIT SWITCH namur application 5114B1 LIMIT SWITCH namur 43 pTC-10 ohm cable NICR-NI thermocouple NE43 Pt100 transmitter 4.20 mA 5114A
    Text: PRetrans 5114 PROGRAMMABLE TRANSMITTER Input for RTD, TC, mV, linear resistance, mA, and V 3-port 3.75 kVAC galvanic isolation Current and voltage output Universal voltage supply 1- and 2-channel versions Loop supply > 18 V in Ex zone 0 Application: Electronic temperature measurement with resistance sensor


    Original
    PDF 5114B namur ne43 Ni100 sensor LIMIT SWITCH namur application 5114B1 LIMIT SWITCH namur 43 pTC-10 ohm cable NICR-NI thermocouple NE43 Pt100 transmitter 4.20 mA 5114A

    Untitled

    Abstract: No abstract text available
    Text: Frequency transducer - MINI MCR-SL-F-UI-SP-NC - 2902833 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid


    Original
    PDF com/us/products/2902833

    PTB Ex 80 1092

    Abstract: No abstract text available
    Text: Level measurement Magnetic float switch For horizontal installation Model HLS WIKA data sheet LM 30.02 Applications •■ Level measurement for almost all liquid media ■■ Pump and level control ■■ Chemical, petrochemical, natural gas, offshore, shipbuilding, machine building, power generating


    Original
    PDF

    V11518

    Abstract: PT-100 RTD 4 wire sensor - rosemount rosemount pt 100 rtd PT-100 RTD 3 wire sensor - rosemount PT100 rosemount pt100 rtd rosemount rosemount PT-1000 sensor PT-100 RTD 3 wire sensor rosemount Rosemount RTD tH02
    Text: FieldIT Data Sheet 10/11 8.19 EN Temperature Transmitter, head mounted TH02/TH02-Ex HART programmable, Pt 100 RTD , thermocouples, electrical isolation Level 0: Information • Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)


    Original
    PDF TH02/TH02-Ex V11518 PT-100 RTD 4 wire sensor - rosemount rosemount pt 100 rtd PT-100 RTD 3 wire sensor - rosemount PT100 rosemount pt100 rtd rosemount rosemount PT-1000 sensor PT-100 RTD 3 wire sensor rosemount Rosemount RTD tH02

    rosemount 1144

    Abstract: rosemount pt 100 rtd V11523 pt100 rtd rosemount PT100 rosemount EC certificate PTB ATEX 1144 X Thermocouple Type L namur NE 43 rosemount PT 441 rosemount PT-1000 sensor
    Text: FieldIT Data Sheet 10/11 8.64 EN Temperature Transmitter, field mounted TH202/TH202-Ex HART programmable, Pt 100 RTD , thermocouples, electrical isolation Level 0: Information • Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)


    Original
    PDF TH202/TH202-Ex rosemount 1144 rosemount pt 100 rtd V11523 pt100 rtd rosemount PT100 rosemount EC certificate PTB ATEX 1144 X Thermocouple Type L namur NE 43 rosemount PT 441 rosemount PT-1000 sensor

    IEC-60751

    Abstract: IEC60751 DIN 43710 namur NE 43 DK-8410 e988 60584 namur NE 21 Pt100 transmitter 4.20 mA Pt100 transmitter
    Text: PReasy 4114 UNIVERSAL TRANSMITTER 5 Input for RTD, TC, Ohm, potentiometer, mA and V 2-wire supply > 16 V FM-approved for installation in Div. 2 Output for current and voltage Universal AC or DC supply Advanced features: • Programmable by way of detachable display front


    Original
    PDF 2004/108/EC 2006/95/EC 4114Y103-UK IEC-60751 IEC60751 DIN 43710 namur NE 43 DK-8410 e988 60584 namur NE 21 Pt100 transmitter 4.20 mA Pt100 transmitter

    Untitled

    Abstract: No abstract text available
    Text: measuring Micro Flow Switch • monitoring with Factory Set Switch Point • analyzing KSR / SVN •• Flow Switch for Low Volumes of Water or Air •• Reed Contact or Proximity Switch •• Vertical Connections for In-line Mounting •• Switching Ranges: 0.03.4.0 GPH Water


    Original
    PDF SVN-1200 SVN-1200. KSR-1200. KSR-1201. SVN-1201. 00V/0

    MTL5513

    Abstract: MTL4513 proximity detectors proximity detector sensor to35Vdc hazardous area EN60947-5-6
    Text: MTL4513 MTL5513 SWITCH/ PROXIMITY DETECTOR INTERFACE MTL4513 Hazardous area To earth-leakage detector * 680W + 6 22kW 2-channel, line fault detection, phase reversal Safe area 12 11 10 5 – 4 The MTLx513 enables two solid-state outputs in the safe area to


    Original
    PDF MTL4513 MTL5513 MTLx513 EPSx513 MTL5513 MTL4513 proximity detectors proximity detector sensor to35Vdc hazardous area EN60947-5-6

    DK-8410

    Abstract: loop powered galvanic isolator
    Text: PRetrans 6185 LOOP-POWERED ISOLATOR 1-, 2- and 4-channel galvanic isolation Slimline channel width of less than 6 mm No separate supply necessary Low response time High noise suppression Application: • Galvanic separation of analogue current signals. • Elimination of ground loops and measurement


    Original
    PDF 6185Y100-UK DK-8410 loop powered galvanic isolator

    block diagram of tachometer

    Abstract: optocoupler with encoder Tachometer
    Text: TA 134 COUNTERS CONTROLLERS ENCODERS Electronic Tachometer with Two Limits Characteristics of device µP - device Tachometer with two limits and scaling Batch counter with scaling factor to be programmed from 0.0001 bis 9999.99 Interface RS485 Technology Functions


    Original
    PDF RS485 block diagram of tachometer optocoupler with encoder Tachometer

    Untitled

    Abstract: No abstract text available
    Text: FB-PS-25/0.36A Isolated Foundation Fieldbus Power Supply/Conditioner INTERFACE Data Sheet 2359_en_A PHOENIX CONTACT - 04/2007 Features – – – – – – – – Isolated power supply for fieldbus segments according to IEC 61158-2 Certified to FF-831 specification


    Original
    PDF FB-PS-25/0 FF-831

    Untitled

    Abstract: No abstract text available
    Text: Isolated DIN Rail Repeater DRSL-DC1 U Isolation and 1:1 Conversion of Current Signals U 1 Current Input— 1 Current Output U Slimline Housing— Only 6 mm 0.24" Wide U Fast Response Time <7 ms U High Accuracy, <0.05% of Span U Easy-to-Use—No Setup Needed


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolated DIN Rail Repeater/Splitter for Current Signals DRSL-SP1 U Isolation and Conversion of Current Signals U Splitter Function: 1 Current Input—2 Current Outputs U Slimline Housing—Only 6 mm 0.24" Wide U Fast Response Time <7 ms U High Accuracy, <0.05% of Span


    Original
    PDF

    optocoupler with encoder

    Abstract: batch counter
    Text: BE 134 COUNTERS CONTROLLERS ENCODERS Electronic Time Meter with Two Presets Characteristics of device Technology Functions Mechanical data Ambient conditions Ambient temperature Storage temperature Relative humidity Protection Operational requirements Classification


    Original
    PDF RS485 optocoupler with encoder batch counter

    membrane key

    Abstract: No abstract text available
    Text: N 214 COUNTERS CONTROLLERS ENCODERS Totalizer and Position Display Features Models Totalizer Position Display Start count can be programmed Scaling factor can be programmed 0.0001.9999.99 Interface RS485, RS422, RS232 Output contact at start count or zero


    Original
    PDF RS485, RS422, RS232 RS485 RS422 membrane key

    Untitled

    Abstract: No abstract text available
    Text: Isolated DIN Rail Signal Conditioner DRSL-DC3 U Isolation and Conversion of Process Voltage or Current Signals U Slimline Housing— Only 6 mm 0.24" Wide U Multiple Signal Ranges (DIP-Switch Selectable) U High Accuracy, <0.2% of Span U Fast Response Time <7 ms


    Original
    PDF

    phoenixcontact

    Abstract: block diagram of multimeter U100k of potentiometer 100k
    Text: 4 t RS 204-5140 P H O E N IX CO NTACT m Phoenix-Contact ! MCR-f/l-100K/V-E Analoge Signalverarbeitung H J| Modulare I I 1 I l i r f Converter für die I V I V ^ I 1 Regelungstechnik 1 RS 204-5134 Phoenix-Contact MCR-f/U-100K/V-E Universal Frequenz-Umsetzer


    OCR Scan
    PDF MCR-f/l-100K/V-E MCR-f/U-100K/V-E phoenixcontact block diagram of multimeter U100k of potentiometer 100k