KFD2-STC4-EX2
Abstract: kfd2-stc4 abb SMART temperature Transmitter transmitter calibration certificate foxboro fisher-rosemount hazardous area Endress namur NE 21 BY260V
Text: SMART Transmitter Power Supply KFD2-STC4-Ex2 - Input EEx ia IIC ? - DC 24 V power supply Input ΙΙ EEx ia IIC ? J J 2-wire transmitters - EMC per NAMUR NE 21 - LED per NAMUR NE 44 The SMART transmitter power supplies supply a 2-wire SMART transmitter within a
|
Original
|
|
PDF
|
Siemens SN 29500
Abstract: LIMIT SWITCH namur 43 LIMIT SWITCH namur application siemens CIB Namur switching amplifier ATEX* II 3D IEC 60947-5-6 namur NE 43 EXIDA
Text: PI-EX-NAM/RNO-NE Ex-i NAMUR Isolation Amplifier INTERFACE Data Sheet 102883_04_en 1 PHOENIX CONTACT - 02/2008 Description The PI-EX-NAM/RNO-NE is a 3-way isolation amplifier. It is designed to operate proximity switches according to EN 60947-5-6 as well as switch contacts with open circuit
|
Original
|
|
PDF
|
28353
Abstract: EN61508
Text: Extract from the online catalog PI-EX-NAM/RNO-NE Order No.: 2835341 Ex-i binary input: NAMUR isolation amplifiers. For operating proximity sensors and switches in Ex areas. The binary signals are transmitted
|
Original
|
IF-2009)
us35/7
28353
EN61508
|
PDF
|
kfd2-sr-ex1
Abstract: KFD2-SR2-EX1.W k-system namur NE 21 VDE 0812 PTB Switch Mode dc to ac Supply circuit DIN19234 EX-94
Text: Transformer Isolated Barrier KF -SR2-Ex1.W Output: Relay - Control circuit EEx ia IIC Class I, Div 1, Groups A-G Switch S3 in position I 1+ - Reversible mode of operation 3- - 1 Signal output with 1 alternator - EMC per NAMUR NE 21 1+ Switch S3 in position I
|
Original
|
|
PDF
|
kfd2-sr-ex2
Abstract: KFA6-SR2-EX2.W kfd2 EX-94 KFD2-SR2-Ex2.W
Text: Transformer Isolated Barrier KF Input ΙΙ - Control circuit EEx ia IIC Class I, Div 1, Groups A-G Switch S3 in position Ι - Reversible mode of operation 1+ 3- 4+ 6- - 1 Signal output with 1 alternator Switch S3 in position Ι - EMC per NAMUR NE 21 10 kΩ
|
Original
|
|
PDF
|
kfd2-stc1-ex1
Abstract: kfd2 fisher-rosemount Ex-94 namur NE 93 namur NE 21 STT01 ST-T01 bailey transmitter abb SMART temperature Transmitter
Text: SMART Transmitter Power Supplies Hazardous area KFD2-ST*1-Ex1* Input EEx ia IIC SMART transmitter SMART communicator 1-channel Input EEx ia IIC; U0 = 28V 24 V DC nominal supply voltage SMART capable up to 12 kHz -1 dB EMC acc. to NAMUR NE 21 1+ 3- 1+ + -
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Data Sheet FieldIT PF 900-NR Power Feed Module Features and Benefits • 24 V DC supply voltage ■ Supply current ≤ 4 A ■ Bus access via terminals ■ Redundant supply ■ Fault signal output with adjustable mode of operation ■ EMC acc. to NAMUR NE 21
|
Original
|
900-NR
3BDD011868R101
|
PDF
|
kfd2-stc4
Abstract: BAS 99 ATEX 7060 kfd2-stc4-ex1 bas99 EN50-020 atex 7060 kfd2-eb2 61508 UPR-03 EN 50014 to 50020
Text: KFD2-STC4-Ex1 SMART transmitter power supply Connection • 1-channel • Device installation permissible in zone 2 • Input EEx ia IIC; Uo = 25.4 V • Galvanically isolated output • 24 V DC supply voltage • SMART capable up to 7.5 kHz -3 dB • EMC acc. to NAMUR NE 21
|
Original
|
PR-03
UPR-03
kfd2-stc4
BAS 99 ATEX 7060
kfd2-stc4-ex1
bas99
EN50-020
atex 7060
kfd2-eb2
61508
EN 50014 to 50020
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Extract from the online catalog PI-EX-NAM/RNO-NE Order No.: 2835341 Ex-i binary input: NAMUR isolation amplifiers. For operating proximity sensors and switches in Ex areas. The binary signals are transmitted to a safe area. Relay output N/O contact , line fault detection.
|
Original
|
IF-2009)
|
PDF
|
KFA6-SR2-Ex2.W
Abstract: IEC 60947-5-6 KFD2-SR2-Ex2.W KFa5-SR2-Ex2.W kfd2-sr-ex2 atex transformer E 106378 60947-5-6 namur standard kfa5-sr2
Text: Transformer Isolated Barriers Input I EEx ia IIC Input II EEx ia IIC 1+ 3- 4+ 3- 4+ 3- 4+ 3- 4+ Switch S3 in position I 2-channel Control circuit EEx ia IIC Reversible mode of operation 1 signal output with 1 changeover contact per channel • EMC acc. to NAMUR NE 21
|
Original
|
|
PDF
|
EX-94
Abstract: kha6-sr2-ex KHA6 namur NE 21 KHA6-SR2-Ex1.W KHA5-S kfd2-sr-ex1 KFD2-SR2-EX1.W DIN19234 KFA5
Text: P R O Z E S S A U T O M A T I O N Trennschaltverstärker K -SR2-Ex1.W Ausgang: Relais Eingang EEx ia IIC - 1-kanalig - Steuerstromkreis EEx ia IIC 1+ 3- - 1 Signalausgang mit 1 Wechsler - EMV gemäß NAMUR NE 21 Schalter S3 in Pos. I 10 kΩ 1+ 3- KFD2-SR2-Ex1.W
|
Original
|
Signalgebe50
EX-94
kha6-sr2-ex
KHA6
namur NE 21
KHA6-SR2-Ex1.W
KHA5-S
kfd2-sr-ex1
KFD2-SR2-EX1.W
DIN19234
KFA5
|
PDF
|
kha6-sr2-ex
Abstract: namur NE 21 KFD2-SR2-Ex2.W KFA6-SR2-EX2.W kfd2-sr-ex2 Ex-94 VDE 0812 PTB VDE 0812 S KHA5-S lb 7610
Text: P R O Z E S S A U T O M A T I O N Trennschaltverstärker K - 2-kanalig Eingang Ι EEx ia IIC -SR2-Ex2.W Ausgang: Relais Eingang ΙΙ EEx ia IIC - Steuerstromkreis EEx ia IIC - 1 Signalausgang mit 1 Wechsler je Kanal 1+ 3- 4+ 6Schalter S3 in Pos. Ι - EMV gemäß NAMUR NE 21
|
Original
|
|
PDF
|
DW-AD-403-04
Abstract: DW-AD-401-04 detecteur de proximite inductif DW-AD-404-04 DW-AD-402-04 DW-AS-401-04 DW-AS-402-04 DW-AS-404-04 Contrinex namur DW-AS-405-04
Text: data sheet Induktiver Näherungsschalter Détecteur de proximité inductif Inductive Proximity Switch DW - A - 40 - 04 Durchmesser Diamètre Diameter 4 mm Miniaturausführung Durchmesser 4 mm glatt Appareil miniature Boîtier lisse de 4 mm de diamètre Wichtigste Eigenschaften:
|
Original
|
|
PDF
|
DIN19240
Abstract: zener diode 5.6 V
Text: Module no:2940799 LabelId:2940799 Operator:Phoenix 18:15:56, Donnerstag, 28. Juni 2001 EIK 1-SVN. for inductive proximity sensors 1 in accordance with NAMUR Terminal width 6.2 Enclosed housing “.6” M3 8 IEC) rigid flexible 2 [mm ] solid stranded AWG
|
Original
|
801-2/EN
DIN19240
zener diode 5.6 V
|
PDF
|
|
KFD2-SR2-Ex2.W
Abstract: IEC 60947-5-6 NE44 kfd2-eb2 60947-5-6 kfd2 atex transformer Pepperl Fuchs kfd2 Ignition Transformer namur standard
Text: Transformer Isolated Barriers KFD2-SR2-Ex2.W Output: Relay Input I EEx ia IIC Input II EEx ia IIC 1+ 4+ 6- 400 Ω ≤ R ≤ 2 kΩ 10 kΩ 3- Switch S3 in position I 10 kΩ 4+ 6- Switch S3 in position I 24 V DC: without SC • • • • 2-channel Control circuit EEx ia IIC
|
Original
|
|
PDF
|
pbt-gf20 relay
Abstract: PA-GF20 BI50-Q80-ADZ30X2-B1131 Ni10-Q25-AN6X M160160 2-Q12-AN6X Lucas Ni15-Q30-AP6X Ni25-Q20-AP6X2-H1141 4-Q12-AP6X
Text: Selection Guide Housing Styles Pages Q5.5 Style 2-Wire DC 3-Wire DC 7-8 9 - 10 Q06 Style 3-Wire DC 11 - 12 Housing Styles Pages Q11S Style 2-Wire DC 3-Wire DC 2-Wire NAMUR 7-8 23 - 24 45 - 46 25 - 26 37 - 38 Q6.5 and Q9.5 Styles 3-Wire DC 13 - 14 Q12 Style
|
Original
|
B9005
1-800-544-PROX
B0143
pbt-gf20 relay
PA-GF20
BI50-Q80-ADZ30X2-B1131
Ni10-Q25-AN6X
M160160
2-Q12-AN6X
Lucas
Ni15-Q30-AP6X
Ni25-Q20-AP6X2-H1141
4-Q12-AP6X
|
PDF
|
pt100 rtd rosemount
Abstract: pt 100 temperature sensor RTD abb PT-100 RTD 4 wire sensor - rosemount rosemount pt 100 rtd rosemount PT-1000 sensor PT-100 RTD 3 wire sensor - rosemount PT-100 RTD 3 wire sensor rosemount PT100 rosemount PT-100 RTD 4 wire sensor rosemount th102
Text: FieldIT Data Sheet 10/11 8.54 EN Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 RTD , thermocouples, electrical isolation Level 0: Information • Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)
|
Original
|
TH102/TH102-Ex
pt100 rtd rosemount
pt 100 temperature sensor RTD abb
PT-100 RTD 4 wire sensor - rosemount
rosemount pt 100 rtd
rosemount PT-1000 sensor
PT-100 RTD 3 wire sensor - rosemount
PT-100 RTD 3 wire sensor rosemount
PT100 rosemount
PT-100 RTD 4 wire sensor rosemount
th102
|
PDF
|
encodeur incremental
Abstract: TRANSISTOR SUBSTITUTION Convertisseur Tension Frequence MCR-F-UI-DC Conector N macho convertidor de frecuencia transitor engranaje BU 2525 AF analogique
Text: Phoenix Contact GmbH & Co. KG D-32823 Blomberg, Germany Fax +49- 0 5235-341200, Tel. +49-(0)5235-300 www.interface.phoenixcontact.com D GB TNR 9000681-03 / 04.2003 Universal Frequenz-Messumformer Universal Frequency Transducer F Convertisseur de fréquences
|
Original
|
D-32823
CISPR11
encodeur incremental
TRANSISTOR SUBSTITUTION
Convertisseur Tension Frequence
MCR-F-UI-DC
Conector N macho
convertidor de frecuencia
transitor
engranaje
BU 2525 AF
analogique
|
PDF
|
namur standard
Abstract: NCB5-18GM40-N0 60947-5-6 en steel series
Text: NCB5-18GM40-N0 Inductive proximity switches Comfort series 5 mm embeddable 37 40 4 M18x1 24 LED Reduction factor rAl 0.35 Reduction factor rCu 0.3 Nominal voltage Uo Current consumption Measuring plate detected Measuring plate not detected Switching frequency f
|
Original
|
NCB5-18GM40-N0
M18x1
namur standard
NCB5-18GM40-N0
60947-5-6
en steel series
|
PDF
|
rosemount 1144
Abstract: rosemount pt 100 rtd V11523 pt100 rtd rosemount PT100 rosemount EC certificate PTB ATEX 1144 X Thermocouple Type L namur NE 43 rosemount PT 441 rosemount PT-1000 sensor
Text: FieldIT Data Sheet 10/11 8.64 EN Temperature Transmitter, field mounted TH202/TH202-Ex HART programmable, Pt 100 RTD , thermocouples, electrical isolation Level 0: Information • Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)
|
Original
|
TH202/TH202-Ex
rosemount 1144
rosemount pt 100 rtd
V11523
pt100 rtd rosemount
PT100 rosemount
EC certificate PTB ATEX 1144 X
Thermocouple Type L
namur NE 43
rosemount PT 441
rosemount PT-1000 sensor
|
PDF
|
phoenix contact 24v 8 channel Relay
Abstract: ATEX EN50082-2
Text: Two-Channel Switch Amplifier With Relay Output, 24 V DC Power Supply PI/Ex-ME-2NAM/COC-24 V DC 1. Modular Electronic Interface for Process Technology Process systems are characterized by a large number of signals. A large proportion of these signals are Ex-i signals, which are not always routed. In this
|
Original
|
PI/Ex-ME-2NAM/COC-24
phoenix contact 24v 8 channel Relay
ATEX
EN50082-2
|
PDF
|
mcr 100a
Abstract: ATEX
Text: Two-Channel Switch Amplifier With Relay Output 230 V AC Power Supply PI/Ex-ME-2NAM/COC-230 V AC 1. Modular Electronic Interface for Process Technology Process systems are characterized by a large number of signals. A large proportion of these signals are Ex-i signals, which are not always routed. In this
|
Original
|
PI/Ex-ME-2NAM/COC-230
mcr 100a
ATEX
|
PDF
|
namur NE 21
Abstract: MF740 DIN19234 kfd2-sr-ex2 la 7610
Text: A U T O M A T I O N C Transformer Isolated Barrier KFD2-SR2-Ex2.W _Output: Relay € - Dual Channel Input I EEx ia IIC Input II EEx ia IIG - Hazardous Field Circuit EEx ia MC and Class I, Div 1, Groups A-G - DC 24 V Nominal Power Supply
|
OCR Scan
|
14AWG)
namur NE 21
MF740
DIN19234
kfd2-sr-ex2
la 7610
|
PDF
|
Ex-94
Abstract: kfd2-sr-ex1 KFD2-SR2-EX1.W khd2-sr namur NE 21 DIN19234
Text: C Transformer Isolated Barrier KFD2-SR2-Ex1.W _Output: Relay € - Single Channel Input EEx ia IIC - Hazardous Field Circuit EEx ia IIC and Class I, Div 1,Groups A-G - DC 24 V Nominal Power Supply ra 1+ - Selectable Mode of Operation
|
OCR Scan
|
14AWG)
Ex-94
kfd2-sr-ex1
KFD2-SR2-EX1.W
khd2-sr
namur NE 21
DIN19234
|
PDF
|