Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    NH2 FUSE Search Results

    NH2 FUSE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCKE800NA Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE800NL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE812NA Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE812NL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, Fixed Over Voltage Clamp, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE712BNL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 13.2 V, 3.65 A, Latch, Adjustable Over Voltage Protection, WSON10 Visit Toshiba Electronic Devices & Storage Corporation

    NH2 FUSE Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    nh2 fuse siemens

    Abstract: HRC Fuse BASE FUSE base NH2 fuse-link nh2
    Text: Product data sheet 3NX3107 MOULDED PLASTIC PUSH-ON COVERS FOR LV HRC FUSE BASE,SIZE 2 Similar to image Technical data: Installation size of fuse-link NH2 Accessories LV HRC contact cover Further information: Information- and Downloadcenter Catalogs, Brochures,…


    Original
    3NX3107 com/WW/view/en/3NX3107/all nh2 fuse siemens HRC Fuse BASE FUSE base NH2 fuse-link nh2 PDF

    NH2 GL-GG

    Abstract: NH00CG10
    Text: NH Fuse Links Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation lines from overload and short circuits. The aM characteristic


    Original
    NH00C NH1CG25 NHB00B NHB00C 90V/160A 90V/250A 90V/400A 90V/630A NHFSC00B NH2 GL-GG NH00CG10 PDF

    nh00 160A fuse

    Abstract: NH3 GL-GG NH00 160A 690V AC 100 A Fuse NH3 fuse aM NH3 630A 160A Fuse nh00 fuse NH2 GL-GG A 7800 nh fuse
    Text: NH Fuse Links Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation lines from overload and short circuits. The aM characteristic


    Original
    NH00C NH1CG25 Volt70 NHB00B NHB00C 90V/160A 90V/250A 90V/400A 90V/630A nh00 160A fuse NH3 GL-GG NH00 160A 690V AC 100 A Fuse NH3 fuse aM NH3 630A 160A Fuse nh00 fuse NH2 GL-GG A 7800 nh fuse PDF

    NH3 GL-GG

    Abstract: NH3 630A nh00 160A fuse 120KA NH2 GL-GG nh00 fuse nh00 fuse 125A size 00 fuse links FUSE 315A NH2 NH3 fuse aM
    Text: International Products NH Fuse Links 500 Volts • 2 – 630 Amperes Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation


    Original
    NH00C NH1CG25 NHB00B NHB00C 90V/160A 90V/250A 90V/400A 90V/630A NHFSC00B NH3 GL-GG NH3 630A nh00 160A fuse 120KA NH2 GL-GG nh00 fuse nh00 fuse 125A size 00 fuse links FUSE 315A NH2 NH3 fuse aM PDF

    NH00CG10

    Abstract: No abstract text available
    Text: NH Fuse Links Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation lines from overload and short circuits. The aM characteristic


    Original
    NH00C NH1CG25 NHB00B NHB00C 90V/160A 90V/250A 90V/400A 90V/630A NHFC00B NH00CG10 PDF

    NH3 fuse aM

    Abstract: NH00C NH2 GL-GG a 7800 NH fuse 500 A NH2M224 NH2CG40 NH2G400 NH00CG10
    Text: International Products NH Fuse links 500 Volts • 2-630 Amperes Specifications Voltage Rating: 500 VAC 440 VDC Ampere Range: 2-630 A Interrupting Rating: 120 kA AC 25 kA DC Standards: DIN 43.620, IEC 60269-2-1 Approvals: VDE gL – gG only Example part number: NH1CG25 (size, characteristic and amperage)


    Original
    NH1CG25 NHB00B NHB00C NHFSC00B NH3 fuse aM NH00C NH2 GL-GG a 7800 NH fuse 500 A NH2M224 NH2CG40 NH2G400 NH00CG10 PDF

    NH00CG10

    Abstract: No abstract text available
    Text: International Products NH FUSE LINKS 500฀Volts฀•฀2-630฀Amperes Specifications 500 VAC 440 VDC Ampere Range: 2-630 A Interrupting Rating: 120 kA AC 25 kA DC Standards: DIN 43.620, IEC 60269-2-1 Approvals: VDE gL – gG only Example part number: NH1CG25 (size, characteristic and amperage)


    Original
    NH1CG25 NHB00B NHB00C NHFSC00B NH00CG10 PDF

    NH3 fuse aM

    Abstract: NH fuse 500 A FUSE base NH2 690 V AC 315 A Fuse NH2 fuse aM a 7800 NH3 GL-GG IEC 269-2-1 NH3 fuse size 00 fuse links
    Text: POWR-GARD Fuse Datasheet NH Fuse links 500 Volts • 2-630 A Specifications Voltage Rating 500 VAC 440 VDC Ampere Range 2-630 A Interrupting Rating 120 kA AC 25 kA DC Standards DIN 43.620, IEC 269-2-1 Approvals VDE Example part number NH1CG25 size, characteristic and amperage


    Original
    NH1CG25 NH00C NHB00B NHB00C NHFSC00B NH3 fuse aM NH fuse 500 A FUSE base NH2 690 V AC 315 A Fuse NH2 fuse aM a 7800 NH3 GL-GG IEC 269-2-1 NH3 fuse size 00 fuse links PDF

    Fuses A

    Abstract: fuse base IEC 269
    Text: NH KNIFE BLADE NH fuses are typically used for power distribution applications and to protect large electrical devices such as motors, drives, etc. They are available in seven sizes with a current range of 2 to 1600 Amps. NH fuses have knife blades at both ends,


    Original
    NHC00 2/660V 4/660V 6/660V 10/660V 16/660V 20/660V 25/660V 32/660V 35/660V Fuses A fuse base IEC 269 PDF

    SIEMENS NH00 160 A FUSE

    Abstract: vde 0636 iec 269 NHC00 vde 0636 IEC 269 SIEMENS NH FUSE NH3 GL-GG Protistor fuse base IEC 269 Neozed
    Text: NEXT FIND IT TABLE OF CONTENTS MINIATURE DIAZED Mini fuses in five sizes to 20 Amps. • Slow Blow • Medium Blow Click for PDF file • Fast Blow • Super Fast Blow NEOZED CYLINDER NH "Bottle" fuses in five sizes to 200 Compact fuses in three sizes to Standard cylinder fuses are


    Original
    6/660V 10/660V 16/660V 20/660V 25/660V 32/660V 35/660V 40/660V 50/660V 63/660V SIEMENS NH00 160 A FUSE vde 0636 iec 269 NHC00 vde 0636 IEC 269 SIEMENS NH FUSE NH3 GL-GG Protistor fuse base IEC 269 Neozed PDF

    ABB CONVERTER E4

    Abstract: Siba nh fuse Siba 20 209 20 SIBA 20 189 04 NH000 43620 ABB NH000 NH00 NH000-20 IEC 60269-2
    Text: Sicherungen für den Halbleiter- und Leitungsschutz gRL Fuse links for semiconductor and line protection gRL NH 000 NH 00 NN 1 NH 2 NH 3 x x x x x Sicherungen mit Schraubkontakten fuses with screwcontacts DIN 43653 AC 690 V AC 690 V AC 690 V AC 690 V AC 690 V


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Technical Data 720133 Effective April 2014 Supersedes January 2014 Bussmann NH Photovoltaic fuse links Product description Bussmann’s range of NH size photovoltaic fuse links is specifically designed to protect and isolate photovoltaic array combiners and disconnects.


    Original
    PDF

    EATON

    Abstract: PV-355ANH3
    Text: Technical Data 720133 Effective April 2014 Supersedes January 2014 Bussmann NH Photovoltaic fuse links Product description Bussmann’s range of NH size photovoltaic fuse links is specifically designed to protect and isolate photovoltaic array combiners and disconnects.


    Original
    PDF

    PV-355ANH3

    Abstract: No abstract text available
    Text: Technical Data 720133 Effective June 2014 Supersedes April 2014 Bussmann NH Photovoltaic fuse links Product description Bussmann’s range of NH size photovoltaic fuse links is specifically designed to protect and isolate photovoltaic array combiners and disconnects.


    Original
    PDF

    FR14GG

    Abstract: NH00GG FR22GG 10x38 gg 500 1000 v FR22UD 8-10/100T
    Text: Special Purpose Fuses Special Purpose Fuses European Fuses Surge Suppression Fuses Isolating fuse list Imax kA one pulse Designation Reference Number Voltage rating (V) Current rating (A) Breaking capacity 1 1 2.5 2.5 3 4.5 4.5 5 5 6.5 6.5 8-10 8-10 8-10


    Original
    10x38 14x51 14x51-63A 22x58-80 90V-200kA 00V-100kA FR14GG NH00GG FR22GG 10x38 gg 500 1000 v FR22UD 8-10/100T PDF

    Accessories

    Abstract: Fuses A
    Text: DIAZED AND NEOZED ACCESSORIES SCREW CAP The Screw Cap types offered fit the various fuse and Fuse Base sizes. They hold the fuses in place and connect the head of the fuse with the load side of the Fuse Holder. The colored blown fuse indicator on the head of the fuse is


    Original
    5/250V NHTC00 NHB00-1-3 Accessories Fuses A PDF

    22x58 CP GRC

    Abstract: FR10GG FR14GC FR14GG FR10GG50V20 FR10GG50V25 FR22GG 690V80kA FR22GC69V80T FR14G
    Text: Special Purpose Fuses Special Purpose Fuses European Fuses Surge Suppression Fuses PROTECTION AGAINST LOW VOLTAGE ARRESTER FAILURE When an arrester fails it can no longer contain overvoltage and thus short circuits , a fuse is needed to prevent its explosion. If the fuse is equipped with a trip-indicator, the user will be aware that the arrester


    Original
    lV-100kA 00V-100kA 90V-80kA 90V-200kA 22x58 CP GRC FR10GG FR14GC FR14GG FR10GG50V20 FR10GG50V25 FR22GG 690V80kA FR22GC69V80T FR14G PDF

    E218757

    Abstract: F215170 nh4 fuse W213643 F201853 V229121 W229122 S2267 R216192 E211075
    Text: Gears & Fuse Gears Gears & Fuse Gears IEC General Purpose Fuses NH Fuses Plastic Bases 00-EP/TP NH fuse bases are designed for fuse-links with rated voltages up to 690 VAC and 440 VDC. They are in compliance with IEC 60269, DIN VDE 0636, part 21, 201 and DIN 43620 dimensions .


    Original
    00-EP/TP S218240 S229119 G226717 J226719 P226724 Q226725 EP01RIP20 EP03RIP20 PP11RIP20 E218757 F215170 nh4 fuse W213643 F201853 V229121 W229122 S2267 R216192 E211075 PDF

    LMT 324

    Abstract: TAG 034 NHC00G sj31 315MJ31-7 NHC00 pj30 ED355 bottle feeder pj30 cc
    Text: Part Number Carton Quantity Weight per Carton kg Volume per Carton (cc) FEEDER PILLAR MJ25 10 1.55 737 MJ29 5 0.97 737 MJ30 (up to 200a) 10 1.56 1345 MJ31 (up to 200a) 10 2.4 1666 250/315 MJ30 5 1.1 880 250/315 MJ31* 5 1.48 1120 PJ30 5 1.1 880 PJ31 5 1.48


    Original
    315MJ31-7 120x80x100 NHC00G NH00G 120x80x100 125x85x90 29x19x15 33x20x19 35x28x16 LMT 324 TAG 034 NHC00G sj31 NHC00 pj30 ED355 bottle feeder pj30 cc PDF

    CAPACITOR DETUNING REACTORS

    Abstract: EW-22 DETUNING REACTOR thyristor of power TSM-HV200 h/h/TSM-HV200
    Text: Film Capacitors Installation and maintenance instructions for thyristor modules TSM-HV series Series/Type: Ordering code: Thyristor modules TSM-HV B44066T….E690 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the


    Original
    B44066T. CAPACITOR DETUNING REACTORS EW-22 DETUNING REACTOR thyristor of power TSM-HV200 h/h/TSM-HV200 PDF

    lucent gps 2424

    Abstract: Galaxy Power GPS 4812 nh00 fuse holder nh00 fuse Galaxy Power Breakers GALAXY MILLENNIUM LUCENT 4824 NH3 fuse NH00 ac distribution panel connection
    Text: dc Distribution and Battery Connections for GPS 4848, GPS 4812, GPS 4824, and GPS 2424 A variety of dc distribution and battery connection modules are available for use with the GALAXY Power Systems family to meet a wide range of applications. Preconfigured dc Distribution


    Original
    equ189 DS98-259LIN DS97-327LIN) lucent gps 2424 Galaxy Power GPS 4812 nh00 fuse holder nh00 fuse Galaxy Power Breakers GALAXY MILLENNIUM LUCENT 4824 NH3 fuse NH00 ac distribution panel connection PDF

    h/h/TSM-HV200

    Abstract: No abstract text available
    Text: Film Capacitors – Power Factor Correction Thyristor Module Series/Type: Ordering code: TSM-HV200 B44066T0200E690 Date: Version: 2010-04-12 4 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the


    Original
    TSM-HV200 B44066T0200E690 h/h/TSM-HV200 PDF

    single phase kvar circuit diagram

    Abstract: h/h/TSM-HV200
    Text: Film capacitors – Power Factor Correction Key components – Thyristor module TSM-HV Series/Type: Ordering code: TSM-HV200 B44066T0200E690 Date: Version: June 2012 6 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the


    Original
    TSM-HV200 B44066T0200E690 single phase kvar circuit diagram h/h/TSM-HV200 PDF

    D-8503

    Abstract: DB503
    Text: Data Overcurrent Circuit B re a k e r Sheet 410.073.270 Ers f. gl. Nr. v y.C T echnical C Data: Vo ltage r a tin g : AC 250 V; DC 65 V;3AC 415 V C urrent r a tin g range: main c i r c u i t 0 .0 5 . . 16 0 .0 5 . .1 6 A Standard c u rre n t r a tin g range:


    OCR Scan
    0631/DIN DIN57636) AH17909 D-8503 DB503 PDF