Untitled
Abstract: No abstract text available
Text: SERIES 886 SuperFly Cordsets Product Selection Guide Quick Disconnect QDC , SingleEnded and Back-to-Back Threaded Coupling, Single-Ended and Back-to-Back 886-021P 886-017P Single-Ended QDC Cable Plug with Nylon Overbraid Page 4 Page 10 Single-Ended QDC
|
Original
|
PDF
|
886-021P
886-017P
886-024R
880-020R
886-023R
880-019R
886-022P
886-018P
|
Braided Shield and Jacket Options and Material Properties
Abstract: No abstract text available
Text: Series 75 Metal-Core Conduit Series 75 Flexible Metal-Core EMI/RFI Conduit Braided Shield and Jacket Options and Material Properties EMI/RFI Braided Shielding and Non-Metallic Fabric Overbraids D B Bronze Heavy-gauge braided bronze wire for pull (tensile) strength in metal-core conduit
|
Original
|
PDF
|
1930s.
Braided Shield and Jacket Options and Material Properties
|
Braided Shield and Jacket Options and Material Properties
Abstract: No abstract text available
Text: Series 74 Helical Tubing Series 74 High-Performance Helical Polymer-Core Convoluted Tubing Systems Braided Shield and Jacket Options and Material Properties EMI/RFI Braided Shielding and Non-Metallic Fabric Overbraids T Tin/Copper 150°C temperature rating, 125 lbs. tensile strength, 96 hr. salt spray corrosion resistance
|
Original
|
PDF
|
|
MIL-PRF-24758-*
Abstract: No abstract text available
Text: MIL-PRF 24758A MIL-PRF-24758-* EMI/EMP Shielding Conduit with Glenair BlueJacket Basic Number Conduit Size Code Table I High Temp Option (See Note 4) Omit for Standard M24758 - G A H BlueJacket 1 Wire overbraid Core A Minimum bend radius B TABLE I CONDUIT SIZE
|
Original
|
PDF
|
4758A
MIL-PRF-24758-*
M24758
MIL-PRF-24758A
M24758-*
|
Untitled
Abstract: No abstract text available
Text: Hi-Temperature Inconel Overbraided Ceramic Fiber Insulated Thermocouples 1.5m m 3⁄16" 4.5m m ( 3⁄16 ") 6m m ( 1⁄4 ") 10 m ( 3⁄8 m ") Probe Style I ߜ High Temperature Ceramic Insulation with Inconel Overbraid ߜ Flexible, Abrasion Resistant ߜ Withstand Temperatures
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Thermocouple Wire MADE IN USA Available! Duplex Extension Grade JX OMEGA will overbraid any thermocouple wire with Inconel 600, 304 SS or tinned copper overbraiding. Both Inconel 600 and SS add durability and abrasion protection. Consult Sales Department.
|
Original
|
PDF
|
EXGG-J-16
EXTT-J-16
EXTT-J-20
EXTT-J-24
EXPP-J-14
EXTT-K-20
480/ft
20/ft.
|
Untitled
Abstract: No abstract text available
Text: Silicone Rubber Insulated High Temperature Heater Hook-Up Wire MADE IN USA HTRG Series ߜ 200°C 392°F Temperature Rating ߜ UL & CSA Certified* ߜ Silicone Rubber Insulated with Treated Glass Overbraid ߜ Tinned Copper Conductor H Discount Schedule 50 to 99 ft. ……………………20%
|
Original
|
PDF
|
HTRG-1CU-612SBK
HTRG-1CU-610SW
HTRG-1CU-610SBK
HTRG-1CU-618SW,
|
Untitled
Abstract: No abstract text available
Text: Thermocouple Wire Duplex Extension Grade BX Available! MADE IN OMEGA will overbraid any thermocouple wire with Inconel 600, 304 SS or tinned copper overbraiding. Both Inconel 600 and SS add durability and abrasion protection. Consult Sales Department. USA
|
Original
|
PDF
|
kg/300m
EXGG-B-20
EXTT-B-26S
EXPP-B-24
EXPP-B-24S
EXFF-B-26S
EXGG-G-24
EXGG-G-24-50,
|
Untitled
Abstract: No abstract text available
Text: Teflon Glass Insulated High Temperature Heater Hook-Up Wire MADE IN USA ® HTTG Series ߜ 250°C 482°F Temperature Rating ߜ UL & CSA Certified* ߜ Single Stranded 7% Nickel-Plated Copper Conductor ߜ Teflon® Tape & Glass Insulation with Teflon® Treated Glass Overbraid
|
Original
|
PDF
|
HTTG-1CU-614S,
kg/300m
|
galvanised steel conduit
Abstract: No abstract text available
Text: Cable Protection Systems HelaGuard Metallic Conduits with Plastic Coating and Metallic Overbraid and Fittings 3.6 Metallic conduits with plastic coating and metallic overbraid • PCSB Galvanised Steel Conduit, PVC Coating, Galvanised Steel Overbraid Flexible galvanised steel conduit with PVC
|
Original
|
PDF
|
PCSB20
PCSB25
PCSB32
PCSB40
PCSB50
galvanised steel conduit
|
Untitled
Abstract: No abstract text available
Text: Conduit Systems M24758/1 EMI/EMP Shielding Conduit M24758/1-16-F Standard Brass, Compressed Brass and FEP Core Designator: See Note 1 Omit for uncomprssed brass F = FEP C = Compressed Brass Basic Part No. Conduit Size Code Wire Overbraid Weather Jacket Core
|
Original
|
PDF
|
M24758/1
M24758/1-16-F
|
Untitled
Abstract: No abstract text available
Text: OMEGAFLEX CHEMICAL TUBING Teflon® PTFE Formulation MADE IN USA Think of OMEGA for Specialty Tubing! See Pages L-71 and L-72 for details. • Coiled and • Plastic Metal Overbraiding • Custom Lengths • Kevlar Wrapping • Flexible Styles To Order Specify Model Number
|
Original
|
PDF
|
TYTT-42-25
TYTT-42-50
TYTT-42-100
TYTT-64-25
TYTT-64-50
TYTT-64-100
TYTT-86-12
TYTT-86-50
TYTT-86-100
TYTT-108-25
|
Untitled
Abstract: No abstract text available
Text: MEDIUM TEMPERATURE CONSTANT WATTAGE HEATING CABLE FE Series B Nickel Chromium Resistance Wire MADE IN USA Contact Module Point Alternately Located 20 Mil FEP TEFLON and Metal Overbraid* Extruded Jacket ߜ Continuous Exposure Rating up to 400°F ߜ Low Watt Density
|
Original
|
PDF
|
FE8-120B
|
886-026 and 886-027
Abstract: No abstract text available
Text: SERIES 886 QDC CORDSET 886-026 and 886-027, Back-to-Back Cordset 886-026 AND 886-027 QDC COUPLING WITH NYLON OVERBRAID OR POLYURETHANE JACKET Overmolded quick disconnect back-to-back cordsets feature abrasion resistant extruded polyurethane jackets or ultraflexible nylon overbraid. Polyamide overmold,
|
Original
|
PDF
|
886-026PARB-B7N-MT-18-686A
886-026 and 886-027
|
|
QQ-B-575
Abstract: No abstract text available
Text: SERIES 103 MasterWrap Lightweight, side-entry EMI/RFI cable wrap with T technology ubular braided sleeving meets the broad range of shielding and mechanical protection requirements in aircraft harness assemblies. But the need to apply conductive overbraid
|
Original
|
PDF
|
|
Overbraid
Abstract: No abstract text available
Text: SERIES 88 SuperFly Connectors Materials, Finishes and Cable Jacket/Overbraid ABOUT SUPERFLY® MATERIALS AND FINISHES Four standard material and finish options are available. A 1 Aluminum shell with Electroless Nickel EN . High reflectivity and poor corrosion resistance make nickel a poor choice for
|
Original
|
PDF
|
|
Series 803
Abstract: No abstract text available
Text: Series 803 Series 803 Mighty Mouse with UN Mating Thread Flexible, Lightweight Phantom Cable Cordsets General Information Series 803 Ultraflexible “Phantom Cable” Cordsets Phantom Cable cordsets feature high-flex rubber-insulated wires, lightweight shield and overbraided jackets for maximum flexibility, reduced size and minimum
|
Original
|
PDF
|
100MHz
1000MHz.
Series 803
|
Untitled
Abstract: No abstract text available
Text: Series 804 Series 804 Push-Pull Mighty Mouse Flexible, Lightweight Phantom Cable Cordsets General Information Series 804 Ultraflexible “Phantom Cable” Cordsets Phantom Cable cordsets feature high-flex rubber-insulated wires, lightweight shield and overbraided jackets for maximum flexibility, reduced size and minimum
|
Original
|
PDF
|
100MHz
1000MHz.
|
Omega k type thermocouple range
Abstract: EXTT-J-20-SB-T EXPP-K-20S-TCB-P EXPP-T-20-TCB-P EXPP-T-20 EXPP-K-20-TCB-P EXPP-E-16-TCB-P EXPP-J-16-TCB-P EXTT-K-20-SB-T EXPP-J-14-TCB-P
Text: H35 EXPP-EXTT-MM3.qxd 1/23/04 11:44 AM Page 35 Heavy Duty Industrial Grade Thermocouple Wire For Your Most Demanding Applications! Shielded Extension Cables Model Number EXTT-K-20-SB-T $1045/1000' Insulated Primary Wires Insulation Over Primaries Metal Overbraid
|
Original
|
PDF
|
EXTT-K-20-SB-T
EPG05
Omega k type thermocouple range
EXTT-J-20-SB-T
EXPP-K-20S-TCB-P
EXPP-T-20-TCB-P
EXPP-T-20
EXPP-K-20-TCB-P
EXPP-E-16-TCB-P
EXPP-J-16-TCB-P
EXTT-K-20-SB-T
EXPP-J-14-TCB-P
|
Untitled
Abstract: No abstract text available
Text: Thermocouple Wire MADE IN USA Available! Duplex Extension Grade JX OMEGA will overbraid any thermocouple wire with Inconel 600, 304 SS or tinned copper overbraiding. Both Inconel 600 and SS add durability and abrasion protection. Consult Sales Department.
|
Original
|
PDF
|
EXGG-J-16
EXTT-J-16
EXTT-J-20
EXTT-J-24
EXPP-J-14
kg/300m
EXGG-G-24
EXGG-G-24-50,
|
Untitled
Abstract: No abstract text available
Text: Thermocouple Wire Overbraiding 304 SS, Inconel or Tinned Copper To Order: For Stainless Steel Overbraid, add the suffix “SB” to the wire part number and specify Stainless Steel Overbraid on your order. For Inconel Overbraid, add the suffix “lB” to the wire part number
|
Original
|
PDF
|
GG-K-20-TCB-200,
|
Untitled
Abstract: No abstract text available
Text: Magnet Mount Thermocouples $ 59 From MADE IN USA Dual Magnet Style Single Magnet Style Shown actual size Shown with optional Teflon insulated lead wires SS overbraided glass lead wire standard IN STOCK FOR FAST DELIVERY! Smaller magnetic mount thermocouples are also available.
|
Original
|
PDF
|
-36-SMPW-M
MP2-J-36-SMPW-M-TT,
|
120-103
Abstract: 120100 120103 connector
Text: Conduit and Conduit Adapters Composite Connector Backshell Adapter For Helical Convoluted Tubing Fits MIL-C-28876 Fiber Optic Connectors 189-039 - Straight, 45o and 90o 2.000 50.8 A Thread 120-100 Convoluted Tubing shown for reference only. For Dacron overbraiding, see Glenair P/N 120-103
|
Original
|
PDF
|
MIL-C-28876
120-103
120100
120103 connector
|
Untitled
Abstract: No abstract text available
Text: Cable Protection Systems HelaGuard Metallic Conduits with Metallic Overbraid and Fittings Fittings for metallic conduits and metallic overbraid Technical Table • SCSB-PC Plain Hole Connector Article-No. Type Nominal Ø Pack Cont. 166-34800 SCSB12-PC 12 10
|
Original
|
PDF
|
SCSB12-PC
SCSB16-PC
SCSB20-PC
SCSB25-PC
SCSB32-PC
SCSB40-PC
B12-PC
|