Rilsan
Abstract: No abstract text available
Text: IN-LINE CHECK VALVE Series VNR L The VNR L check valve belongs to the LINE ON LINE family, which means it can be connected to all the other components in series or in parallel. Available in the version for pipe-pipe connection with two FOX push-in fittings, and in the version for thread-pipe
|
Original
|
Polyamide12
Rilsan
|
PDF
|
Adapters and Transitions
Abstract: No abstract text available
Text: Adapters and Transitions Male & Female Series Metal Straight Tapered Pipe Thread Adapters for Series 72 & 74 Tubing and Series 75 Conduit Metal straight tapered pipe thread adapters mate with transition fittings How To Order Finish Table II Product Series
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: CSGA GA/CSGA-*/NPT-49B Female Pipe Thread Stainless Steel Cable Shield Grounding Assembly Basic Number National Pipe Thread Fitting Size Table I GA/CSGA - */NPT - 49B Mod Code (Stainless Steel) 8.000 (203.2) Approx. A Thread Min Shield O.D. D Max Cable B
|
Original
|
/NPT-49B
GA/CSGA-P/NPT-49B
GA/CSGA-R/NPT-49B
GA/CSGA-S/NPT-49B
GA/CSGA-T/NPT-49B
GA/CSGA-V/NPT-49B
|
PDF
|
M7000
Abstract: No abstract text available
Text: g GENERAL PURPOSE SENSORS TAPERED PIPE PLUG SENSORS WITH EXTENSION LEADS TYPE M7000: Features • Extremely rugged sensor for use in temperature measurement applications where high pressures or fluids are present. The thermistor is encapsulated into a threaded pipe plug fitting.
|
Original
|
M7000:
1/16-27NPT
1/2-14NPT.
M7000
|
PDF
|
M7000
Abstract: Thermometrics threaded pipe
Text: GENERAL PURPOSE SENSORS TAPERED PIPE PLUG SENSORS WITH EXTENSION LEADS TYPE M7000: Features • Extremely rugged sensor for use in temperature measurement applications where high pressures or fluids are present. The thermistor is encapsulated into a threaded pipe plug fitting.
|
Original
|
M7000:
1/16-27NPT
1/2-14NPT.
M7000
Thermometrics
threaded pipe
|
PDF
|
CSGA-D/NPT
Abstract: GA/CSGA-c/NPT CSGA GA/CSGA-G D-18 GA/CSGA-C/NPT-49B
Text: CSGA GA/CSGA-*/NPT-49B Female Pipe Thread Stainless Steel Cable Shield Grounding Assembly Basic Number National Pipe Thread Fitting Size Table I GA/CSGA - */NPT - 49B Mod Code (Stainless Steel) 8.000 (203.2) Approx. A Thread Min Shield O.D. D Max Cable B
|
Original
|
/NPT-49B
GA/CSGA-P/NPT-49B
GA/CSGA-R/NPT-49B
GA/CSGA-S/NPT-49B
GA/CSGA-T/NPT-49B
GA/CSGA-V/NPT-49B
GA/CSGA-K/NPT-49B
CSGA-D/NPT
GA/CSGA-c/NPT
CSGA
GA/CSGA-G
D-18
GA/CSGA-C/NPT-49B
|
PDF
|
GA/CSGA-**/NPT
Abstract: No abstract text available
Text: CSGA GA/CSGA-*/NPT Female Pipe Thread Cable Shield Grounding Assembly Basic Number National Pipe Thread Fitting Size Table I GA/CSGA - */NPT 8.000 (203.2) Approx. A Thread Min Shield O.D. Max Cable B O.D. D Shrink Tube APPLICATION NOTES 2013 Glenair, Inc.
|
Original
|
|
PDF
|
D-20
Abstract: No abstract text available
Text: CSGA GA/CSGA-*/NPT Female Pipe Thread Cable Shield Grounding Assembly Basic Number National Pipe Thread Fitting Size Table I GA/CSGA - */NPT 8.000 (203.2) Approx. A Thread Min Shield O.D. Max Cable B O.D. D Shrink Tube APPLICATION NOTES 2010 Glenair, Inc.
|
Original
|
|
PDF
|
GA/CSGA-*/NPT
Abstract: No abstract text available
Text: CSGA GA/CSGA-*/NPT Male Pipe Thread Cable Shield Grounding Assembly Basic Number National Pipe Thread Fitting Size Table I GA/CSGA - A/NPT 8.000 (203.2) Approx Min Shield O.D. Max Cable O.D. B D A Thread Shrink Tube APPLICATION NOTES 2013 Glenair, Inc.
|
Original
|
|
PDF
|
CSGA-D/NPT
Abstract: NPT-49B GA/CSGA-c/NPT D-16 4-14NPT 06324 Glenair 1320 backshell
Text: CSGA GA/CSGA-*/NPT-49B Male Pipe Thread Stainless Steel Cable Shield Grounding Assembly Basic Number National Pipe Thread Fitting Size Table I GA/CSGA - A/NPT - 49B Mod Code (Stainless Steel) 8.000 (203.2) Approx Min Shield O.D. D Max Cable O.D. B A Thread
|
Original
|
/NPT-49B
GA/CSGA-P/NPT-49B
GA/CSGA-R/NPT-49B
GA/CSGA-S/NPT-49B
GA/CSGA-T/NPT-49B
GA/CSGA-V/NPT-49B
GA/CSGA-K/NPT-49B
CSGA-D/NPT
NPT-49B
GA/CSGA-c/NPT
D-16
4-14NPT
06324 Glenair 1320 backshell
|
PDF
|
CSGA
Abstract: CSGA-D/NPT 4-14NPT GA/CSGA-c/NPT CSGAj
Text: CSGA GA/CSGA-*/NPT Male Pipe Thread Cable Shield Grounding Assembly Basic Number National Pipe Thread Fitting Size Table I GA/CSGA - A/NPT 8.000 (203.2) Approx Min Shield O.D. Max Cable O.D. B D A Thread Shrink Tube APPLICATION NOTES 2010 Glenair, Inc.
|
Original
|
|
PDF
|
GA/CSGA-*/NPT-49B
Abstract: No abstract text available
Text: CSGA GA/CSGA-*/NPT-49B Male Pipe Thread Stainless Steel Cable Shield Grounding Assembly Basic Number National Pipe Thread Fitting Size Table I GA/CSGA - A/NPT - 49B Mod Code (Stainless Steel) 8.000 (203.2) Approx Min Shield O.D. D Max Cable O.D. B A Thread
|
Original
|
/NPT-49B
GA/CSGA-P/NPT-49B
GA/CSGA-R/NPT-49B
GA/CSGA-S/NPT-49B
GA/CSGA-T/NPT-49B
GA/CSGA-V/NPT-49B
GA/CSGA-*/NPT-49B
|
PDF
|
FLOW captor 4114.30
Abstract: FLOW captor 4115.30 FLOW captor sensor Flow meter 4115.30 applications of flow meter "flow meter" Captor Management
Text: flow-captor flow-captor Type 4114.30, 4115.30 The flow-captor type 4114.30 / 4115.30 is a flow meter for industrial applications which can be installed virtually non-intrusively into any pipe, allowing flow-sensing without obstruction of the pipe diameter.
|
Original
|
30-US
FLOW captor 4114.30
FLOW captor 4115.30
FLOW captor
sensor Flow meter
4115.30
applications of flow meter
"flow meter"
Captor Management
|
PDF
|
ms21209
Abstract: ms21209 inserts NASM33537 LN 9499 NASM21209 LN 9499 03 075 NASM 33537 MS122076 LN 9499 friction thread NASM8846
Text: 0101/09.02 UNC American National Coarse Thread UNF American National Fine Thread BSW British Standard Whitworth Thread BSF British Standard Fine Thread BSP/ G British Standard Pipe Thread ISO 228/1 Pipe Thread BA British Association Standard Thread Imperial thread inserts for metals
|
Original
|
|
PDF
|
|
pt100 datasheet
Abstract: rtd pt100 sensor PT100 2 wire temperature sensor PT100 IEC 751 PT100 IEC 751 accuracy sensor PT100 PT100 temperature sensor PT100 temperature sensor data sheet PT100 4 wire temperature sensor PT100 temperature
Text: TECHNICAL DATASHEET TEMPERATURE SENSORS P R E C I S I O N I N E L E C T R O N I C S 0.5 sec response time, 100Ω pipe clamp fitting RTD type 29393 This 100R IEC 751 class B sensor has very fast response and is ideal for industrial control applications. The pipe clamp fitting allows a fast non intrusive
|
Original
|
PT100
pt100 datasheet
rtd pt100 sensor
PT100 2 wire temperature sensor
PT100 IEC 751
PT100 IEC 751 accuracy
sensor PT100
PT100 temperature sensor
PT100 temperature sensor data sheet
PT100 4 wire temperature sensor
PT100 temperature
|
PDF
|
Rilsan
Abstract: No abstract text available
Text: IN-LINE PRESSURE GAUGE Series MAN L P N E U M A T I C The MAN L pressure gauge belongs to the LINE ON LINE family, which means it can be connected to all the other components in series or in parallel. Available in the version for pipe-pipe connection with two
|
Original
|
|
PDF
|
L-Bracket (to mount) datasheet
Abstract: No abstract text available
Text: IN-LINE PRESSURE INDICATOR Series LAM L P N E U M A T I C The LAM L pneumatic light indicator belongs to the LINE ON LINE family, which means it can be connected to all the other components in series or in parallel. Available in the version for pipe-pipe connection with two
|
Original
|
M15x1
L-Bracket (to mount) datasheet
|
PDF
|
rilsan b
Abstract: Rilsan 4.9.1 r
Text: IN-LINE QUICK-EXHAUST VALVES Series VSR L P N E U M A T I C The VSR L quick-exhaust valve belongs to the LINE ON LINE family, which means it can be connected to all the other components in series or in parallel. Available in the version for pipe-pipe connection with two
|
Original
|
|
PDF
|
M15X1
Abstract: No abstract text available
Text: IN-LINE SHUTOFF VALVE P N E U M A T I C Series “V2V L” and “V3V L” V2V L and V3V L shutoff valves belong to the LINE ON LINE family which means they can be connected to all the other components in series or in parallel. Available in the version for pipe-pipe connection with two
|
Original
|
M15x1
|
PDF
|
Project Report of fire alarm
Abstract: Project Report of simple fire alarm asp105 AIR FLOW DETECTOR FULL REPORT power wizard 1.1 fault codes
Text: FAAST Fire Alarm Aspiration Sensing Technology Table of Contents 3825 Ohio Avenue, St. Charles, Illinois 60174 1.800.SENSOR2; Fax: 630.377.6495 www.systemsensor.com Modifying the Pipe Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
|
Original
|
SS-400-007
E56-3621-003
Project Report of fire alarm
Project Report of simple fire alarm
asp105
AIR FLOW DETECTOR FULL REPORT
power wizard 1.1 fault codes
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Conductivity Sensors Series CDE680 Contacting Conductivity Probes for Use with CDTX680 Series Transmitters and CDCN684, CDCN685 and CDCN686 Series Controllers CDE681 Compression Fitting Sensor Typical Mounting SENSOR CABLE 6.1 M 20' 3/4" PIPE (CUSTOMER PROVIDED)
|
Original
|
CDE680
CDTX680
CDCN684,
CDCN685
CDCN686
CDE681
CDCN684
CDE684-A-1
CDE684-A-2
|
PDF
|
Pipe Thread Adapters
Abstract: series 33
Text: 33 Series 33 Pipe Thread Adapters PRODUCT FEATURES Internal and External Thread Styles Provides Interconnection of NPT Fittings to All Common Circular Connectors Straight Configurations Only Easy integration of NPT conduits in safety-critical interconnect systems
|
Original
|
|
PDF
|
DIN 3852
Abstract: 9130 J127
Text: Industrial Pipe Fittings and Adapters BSP Adapters 4300 Catalog Part Data Reducing Adapter/Expander RI-ED Male BSPP, DIN 3852, Form E EOlastic Seal / Female BSPP * * All dimensions in millimeters. WORKING PRESSURE bar psi G MALE THREAD BSPP d1 FEMALE THREAD
|
Original
|
RI11/2EDX1/2A3C
RI11/2EDX3/4A3C
RI11/2EDX1A3C
RI11/2EDX11/4A3C
RI2EDX11/2A3C
DIN 3852
9130
J127
|
PDF
|
CZ122
Abstract: Norgren 36 0523 03 metric banjo bolt banjo fittings martonair BSP 1 thread 48 0213 BSP 1" thread 34-0272-02 BS 2874-1986
Text: BSP Pipe Fittings /8" – 1" BSP 1 ● Suitable for most general industrial purposes ● Manufactured from extruded bar or hot brass stampings ● Reliable and corrosion resistant Technical Data Medium: Compressed air or any hydraulic fluids which are compatible
|
Original
|
CZ121)
CZ122)
CZ122
Norgren 36 0523 03
metric banjo bolt
banjo fittings
martonair
BSP 1 thread
48 0213
BSP 1" thread
34-0272-02
BS 2874-1986
|
PDF
|