Untitled
Abstract: No abstract text available
Text: EST-A40PS Type: Programmed Rapid Start Electronic Ballast Lamp Connection: Series Wired Lamp Types: Three PL-T42W, PL-T32W, PL-T26W or PL-L40W, PL-L39W, PL-L36W SLI or cross reference GE, Philips or Sylvania/OSRAM lamps SPECIFICATIONS Input Number Voltage of Lamps
|
Original
|
EST-A40PS
PL-T42W,
PL-T32W,
PL-T26W
PL-L40W,
PL-L39W,
PL-L36W
PL-T42W
PL-T32W
PL-T26W
|
PDF
|
Untitled
Abstract: No abstract text available
Text: CSD-UV18PS Group Type: Programmed Start Electronic Ballast Lamp Connection: Dual Lamp in Series Lamp Types: *A. One or Two 13 Watt PL-T or PL-C/4P *B. One or Two 18 Watt PL-T or PL-C/4P *C. One 28 Watt 2D SLI or cross reference GE, Philips or Sylvania/OSRAM lamps
|
Original
|
CSD-UV18PS
|
PDF
|
CSS-UV42PS
Abstract: No abstract text available
Text: CSS-UV42PS Group Type: Programmed Start Electronic Ballast Lamp Connection: Single Lamp Types: One PL-T42W, PL-T32W, FT40W, FT39W, FT36W, CL40W or 2D55W or One or Two PL-T26W SLI lamps or cross reference GE, Philips or Sylvania/OSRAM lamps SPECIFICATIONS Input
|
Original
|
CSS-UV42PS
PL-T42W,
PL-T32W,
FT40W,
FT39W,
FT36W,
CL40W
2D55W
PL-T26W
PL-T26W
|
PDF
|
Untitled
Abstract: No abstract text available
Text: TSS-UV55PBXM Type: Programmed Start Electronic Ballast Lamp Connection: Single Lamp Types: One PL-L55W, PL-L50W, T5 54W or T5 39WSLI lamps or cross reference GE, Philips or Sylvania/OSRAM lamps SPECIFICATIONS Input Number Lamp Lamp Input Watts Input Current Power Max Crest Ballast Bench Heat Test
|
Original
|
TSS-UV55PBXM
PL-L55W,
PL-L50W,
39WSLI
PL-L55W
PL-L50W
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FSD-B32P Group Type: Programmed Start Electronic Ballast Lamp Connection: Dual Lamps in Series Lamp Types: One or Two 26W or 32W PL-T, 24W or 36W PL-L, 21W T5, 21W or 28 2D or One 42W PL-T or 40W or 50W PL-L SLI lamps or cross reference GE, Philips or Sylvania/OSRAM lamps
|
Original
|
FSD-B32P
PL-T32W
PL-T26W
PL-L36W
PL-L24W
21WT5
2D28W
2D21W
PL-T42W
|
PDF
|
Untitled
Abstract: No abstract text available
Text: CSD-UV70PS Group Type: Programmed Start Electronic Ballast Lamp Connection: Single Lamp Types: *A. One or Two 70 Watt PL-T *B. Two 57 Watt PL-T SLI lamps or cross reference GE, Philips or Sylvania/OSRAM lamps SPECIFICATIONS Input Number Voltage of Lamps Lamp
|
Original
|
CSD-UV70PS
|
PDF
|
Untitled
Abstract: No abstract text available
Text: CSS-UV70PS Group Type: Programmed Start Electronic Ballast Lead Connection: Dual Lamps in Series Lamp Types: One PL-T70W or PL-T57W SLI lamps or cross reference GE, Philips or Sylvania/OSRAM lamps SPECIFICATIONS Input Number Voltage of Lamps Lamp Type Lamp Input Watts Input Current Power
|
Original
|
CSS-UV70PS
PL-T70W
PL-T57W
PL-T70W
PL-T57W
|
PDF
|
electronic ballast 18w
Abstract: No abstract text available
Text: BALLAST FSD-B18P Group TM INNOVATIONS Type: Programmed Start Electronic Ballast • Lamp Connection: Dual Lamps in Series • Lamp Types: One or Two: 18W or 13W PL-T, 18W or 13W PL-C, 16W 2D or Two: F17T8 or One: 21W, 28W or 38W 2D, F25T8, 26W PL-T, 26W PL-C or 9W, 14W, 21W or 28W T5
|
Original
|
FSD-B18P
F17T8
F25T8,
electronic ballast 18w
|
PDF
|
Untitled
Abstract: No abstract text available
Text: CSD-UV24PBX Type: Programmed Start Electronic Ballast Lamp Connection: Dual Lamps in Series Lamp Types: One or Two PL-L24W, F27BX, F24BX or two PL-L18W SLI lamps or cross reference GE, Philips or Sylvania/OSRAM lamps SPECIFICATIONS Input Voltage Number of Lamps
|
Original
|
CSD-UV24PBX
PL-L24W,
F27BX,
F24BX
PL-L18W
PL-L18
PL-L24
F24BX
|
PDF
|
Untitled
Abstract: No abstract text available
Text: CSD-UV32PSX Group Type: Programmed Start Electronic Ballast Lead Connection: Dual Lamps in Series Lamp Types: One or Two PL-T32W or PL-T26W or Two PL-L36W or One PL-T42W SLI lamps or cross reference GE, Philips or Sylvania/OSRAM lamps SPECIFICATIONS Input
|
Original
|
CSD-UV32PSX
PL-T32W
PL-T26W
PL-L36W
PL-T42W
PL-T32W
PL-T26W
PL-L36W
|
PDF
|
OSRAM DULUX f
Abstract: No abstract text available
Text: AC-2/26T4UVS1 Group BALLAST TM INNOVATIONS Type: Programmed Start Electronic Ballast Lamp Connection: Dual Lamps in Series Lamp Types SEE CORRESPONDING LETTER IN CHART : *A. One or Two 26W Biax T/E, Dulux T/E, PL-T, Biax D/E, Dulux D/E, or PL-C/4P *B. One 32W or 42W Biax T/E, Dulux T/E, or PL-T
|
Original
|
AC-2/26T4UVS1
1x22W
1x40W
OSRAM DULUX f
|
PDF
|
Untitled
Abstract: No abstract text available
Text: CSD-B42PS Group Type: Programmed Start Electronic Ballast Lead Connection: Dual Lamps in Series Lamp Types: One or Two 42W or 32W PL-T or PL-C or One or Two 36W, 39W or 40W PL-L or One 55W or 50W PL-L or Two 26W PL-T or PL-C SLI lamps or cross reference GE, Philips or Sylvania/OSRAM lamps
|
Original
|
CSD-B42PS
PL-T/C42W
PL-T/C32W
PL-T/C26W
PL-L40W
PL-L39W
PL-T/C36W
|
PDF
|
Untitled
Abstract: No abstract text available
Text: AC-2/18T4UVS Group Type: Programmed Start Electronic Ballast Lamp Connection: Dual Lamps In Series Lamp Types SEE CORRESPONDING LETTER IN CHART : *A. One or Two 18 Watt Biax T/E, Dulux T/E, PL-T/4P, Biax D/E, Dulux D/E, PL-C/4P *B. One or Two 13 Watt Biax T/E, Dulux T/E, Biax D/E, PL-C/4P
|
Original
|
AC-2/18T4UVS
|
PDF
|
electronic ballast for uv tube light
Abstract: DC PL Ballast ignition driver pl lamp ballast 12v lamp driver a boost dc to ac inverter dc-ac inverter ELECTRONIC BALLAST MICROCONTROLLER HT48RA0A uv tube lamp circuits
Text: HT48RA0A/HT48RA0-1/HT48RA0-2 PL Lamp Driver HT48RA0A/HT48RA0-1/HT48RA0-2 PL Lamp Driver D/N: HA0091E Introduction The PL lamps is driven by inverters, which generally provides a wide range of DC input voltage and transfer it up to be a high frequency and high-voltage output to run the lamps.
|
Original
|
HT48RA0A/HT48RA0-1/HT48RA0-2
HT48RA0A/HT48RA0-1/HT48RA0-2
HA0091E
00000010b
00000001b
electronic ballast for uv tube light
DC PL Ballast
ignition driver
pl lamp ballast
12v lamp driver
a boost dc to ac inverter
dc-ac inverter
ELECTRONIC BALLAST MICROCONTROLLER
HT48RA0A
uv tube lamp circuits
|
PDF
|
|
PL-L40/41
Abstract: No abstract text available
Text: EPQ-A40PBXHS Type: Instant Start Electronic Ballast Lamp Connection: Parallel Lamp Types: Three or Four PL-L40W, F39BX/F36BX or FT40DL/28W SLI lamps or cross reference GE, Philips or Sylvania/OSRAM lamps SPECIFICATIONS Input Voltage Number of Lamps Lamp Type
|
Original
|
EPQ-A40PBXHS
PL-L40W,
F39BX/F36BX
FT40DL/28W
F36BX
F39BX
PL-L40/41
|
PDF
|
Electronic ballast 28W
Abstract: No abstract text available
Text: EPQ-A40PBXS/L Type: Instant Start Electronic Ballast Lamp Connection: Parallel Lamp Types: Three or Four 40W PL-L, FBX39, FBX36, or FTDL40/28W SLI lamps or cross reference GE, Philips or Sylvania/OSRAM lamps SPECIFICATIONS Input Voltage Number of Lamps Lamp Type
|
Original
|
EPQ-A40PBXS/L
FBX39,
FBX36,
FTDL40/28W
PL-L40W
PL-L39W
PL-L36W
Electronic ballast 28W
|
PDF
|
Untitled
Abstract: No abstract text available
Text: TSD-UV40PBXMS Type: Programmed Start Electronic Ballast Lamp Connection: Dual Lamp in Series Lamp Types: One or Two FT40W, FT39W or FT36W, PL-T32W, FT40/ES 28 , FT40/ES(25) SLI lamps or cross reference GE, Philips or Sylvania/OSRAM lamps SPECIFICATIONS Input
|
Original
|
TSD-UV40PBXMS
FT40W,
FT39W
FT36W,
PL-T32W,
FT40/ES
|
PDF
|
Untitled
Abstract: No abstract text available
Text: AC-B4/40PBXRS Type: Programmed Start Electronic Ballast Lamp Connection: Dual Lamps in Series Lamp Types: One, Two, Three or Four PL-L40W, F36BX, F39BX, FT40DL/28W SLI lamps or cross reference GE, Philips or Sylvania/OSRAM lamps SPECIFICATIONS Input Voltage
|
Original
|
AC-B4/40PBXRS
PL-L40W,
F36BX,
F39BX,
FT40DL/28W
F39BX
F36BX
|
PDF
|
Untitled
Abstract: No abstract text available
Text: EST-340PBXS Type: Programmed Rapid Start Electronic Ballast Lamp Connection: Dual Lamps in Series Lamp Types: Two or Three PL-L 40, 39 or 36 Watt SLI lamps or cross reference GE, Philips or Sylvania/OSRAM lamps SPECIFICATIONS Input Voltage Number of Lamps
|
Original
|
EST-340PBXS
|
PDF
|
philips Electronic ballast t5
Abstract: No abstract text available
Text: AC-B2/54T5XS Type: Programmed Rapid Start Electronic Ballast Lamp Connection: Dual Lamps in Series Lamp Types: One or Two 54W T5 or 50W or 55W PL-L or Two 39W T5 SLI lamps or cross reference Philips, GE or Sylvania/OSRAM lamps SPECIFICATIONS Input Voltage
|
Original
|
AC-B2/54T5XS
philips Electronic ballast t5
|
PDF
|
Untitled
Abstract: No abstract text available
Text: AC-A4/40PBXRS Type: Programmed Start Electronic Ballast Lamp Connection: Dual Lamps in Series Lamp Types: One, Two, Three or Four *A. 40W, 39W, 36W T5 Biax L, Dulux L, PL-L or FT *B. 28W FT40DL SLI lamps or cross reference GE, Philips or Sylvania/OSRAM lamps
|
Original
|
AC-A4/40PBXRS
FT40DL
|
PDF
|
CSD-UV42PS
Abstract: No abstract text available
Text: CSD-UV42PS Group BALLAST TM Type: Programmed Start Electronic Ballast Lamp Connection: Dual Lamps in Series Lamp Types SEE CORRESPONDING LETTER IN CHART : *A. One or Two 26, 32 or 42 Watt PL-T/4P *B. One or Two FT36W, FT39W or FT40W *C. One FT55W or FT50W
|
Original
|
CSD-UV42PS
FT36W,
FT39W
FT40W
FT55W
FT50W
|
PDF
|
resistor 100k ohm
Abstract: zener diode c5 IPH 40w electronic ballast circuit diagram schematic lamp ballast IR2159 resistor* 100k ohm inductor 20mh WY0222MCMBF0K 680k ohm resistor TRANSISTOR mosfet
Text: APPLICATION NOTE AN-1021 International Rectifier • 233 Kansas Street El Segundo CA 90245 USA IR2159: 40W/PL-L Lamp Dimmable Ballast By T. Ribarich and E. Thompson TOPICS COVERED Introduction Functional Description Schematic Diagrams Bill of Materials Waveforms / Measurements
|
Original
|
AN-1021
IR2159:
PL-L/40W
IR2159
PL-L/40W
resistor 100k ohm
zener diode c5 IPH
40w electronic ballast circuit diagram
schematic lamp ballast
resistor* 100k ohm
inductor 20mh
WY0222MCMBF0K
680k ohm resistor
TRANSISTOR mosfet
|
PDF
|
BGF717-UV1
Abstract: uv lamp pl lamp ballast 365nm
Text: 07.O±O.3 17.0 MAX. 1K V VI 07.5 MAX. 02.4 REF. * V1 FILAMENT: 5.2-5.5 VDC FILAMENT CURRENT: 4 5 + /- 10 mA DC V2 ELECTRODE SOURCE: 24-26 VDC TYP. ELECTRODE CURRENT: 14+/-3.0 mA DC BALLAST RESISTOR: 1KTYP. ELECTRODE RUNNING VOLTAGE: 10+/-3.0 V D C TOTAL LAMP WATTAGE:
|
OCR Scan
|
365nm
BGF717-UV1
P-9911-03
BGF717-UV1
uv lamp
pl lamp ballast
|
PDF
|