Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    Q8486A Search Results

    Q8486A Datasheets (1)

    Part ECAD Model Manufacturer Description Curated Datasheet Type PDF
    Q8486A Agilent Technologies Q8486A Thermocouple Waveguide Power Sensor, 33 GHz to 50 GHz Original PDF

    Q8486A Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Digital Panel Meter PM 128

    Abstract: Digital Panel Meter PM 129 8484a 8900C E4416A 8481D 11730A power sensor cable 11730A E4418A E4418B
    Text: 01SEC027_IN.QXD 9/6/00 2:13 PM Page 303 Power Meters Peak and Average Power Meters • Peak, peak-to-average ratio and average power measurements • Time-gated power measurements • Fast measurement speed over the GPIB up to 1,000 readings per second with the E4416A and E9320 power sensors


    Original
    PDF 01SEC027 E4416A E9320 RS-232/422 E4417A E932X UG-599/U Digital Panel Meter PM 128 Digital Panel Meter PM 129 8484a 8900C 8481D 11730A power sensor cable 11730A E4418A E4418B

    E4418B

    Abstract: E4419B E4419 V8486A E441xB-915 E4412A E9300 700PW E441xB-909 ISO calibration certificate formats
    Text: Agilent E4418B/E4419B EPM Series Power Meters, E-Series and 8480 Series Power Sensors Data Sheet Why Agilent’s power meters and sensors? [|t;C|[P³rtjrs[§f‰§t„j³ª‰|¾µt‰„ª Ä[§È³‰Å[§³[µ[§³;„S³ª[„ª‰§³f§‰³jt|[„µ³M‰„ªtªµ[„µ|ȳS[|tÄ[§ª³j§[;µ³§[ª¾|µª•³


    Original
    PDF E4418B/E4419B E4418B/9B cdma2000® 480A/B/H, N8480A/B/H, R/Q8486A, N8486AR/AQ 5965-6382E E4418B E4419B E4419 V8486A E441xB-915 E4412A E9300 700PW E441xB-909 ISO calibration certificate formats

    Untitled

    Abstract: No abstract text available
    Text: Agilent N1913A and N1914A EPM Series Power Meters E-Series and 8480 Series Power Sensors Consistent Results and Greater Capability Data Sheet As signals become more complex, it becomes more difficult to make fast, accurate power measurements. For years, you’ve depended on Agilent’s


    Original
    PDF N1913A N1914A E4418B/19B BP-3-1-13) 5990-4019EN

    Untitled

    Abstract: No abstract text available
    Text: Agilent N1913A and N1914A EPM Series Power Meters E-Series and 8480 Series Power Sensors Consistent Results and Greater Capability Data Sheet As signals become more complex, it becomes more difficult to make fast, accurate power measurements. For years, you’ve depended on Agilent’s


    Original
    PDF N1913A N1914A E4418B/19B 5990-4019EN

    8485A

    Abstract: e4412a service manual 8481A E4418B E4413A e4412a 11730A 8481D 8482B R8486A
    Text: Agilent EPM Series Power Meters E-Series and 8480 Series Power Sensors Data Sheet Product specifications and characteristics EPM series E4418B and E4419B power meters Specifications Accuracy Specifications describe the instrument’s warranted performance and


    Original
    PDF E4418B E4419B 5965-6382E 8485A e4412a service manual 8481A E4413A e4412a 11730A 8481D 8482B R8486A

    11730A

    Abstract: HP8481H 8481B 8481H apc-7 connector 11730B japanese diode manual HPE1416A E1416A 8485A
    Text: PDFINFO H5 5 6 4 - 0 1 Power Meter HP E1416A Technical Specifications ● ● ● ● ● Single channel ± 0.02 dB or ± 0.5% accuracy 100 kHz to 100 GHz –70 to + 44 dBm 1 mW power reference Description The HP E1416A Power Meter is a C-size, 1-slot, message-based VXI module. It is a high-performance,


    Original
    PDF E1416A E1416A 8482B 8482B 8481H 8481H 8482H 8482H 11730A HP8481H 8481B apc-7 connector 11730B japanese diode manual HPE1416A 8485A

    Untitled

    Abstract: No abstract text available
    Text: Agilent N1913A and N1914A EPM Series Power Meters E-Series and 8480 Series Power Sensors Consistent Results and Greater Capability Data Sheet As signals become more complex, it becomes more difficult to make fast, accurate power measurements. For years, you’ve depended on Agilent’s


    Original
    PDF N1913A N1914A E4418B/19B BP-3-1-13) 5990-4019EN

    N8481A

    Abstract: Diode Sensors N1917C W8486A N8480 n8487A E4410 E9301B agilent CFT 455 n-type connector male
    Text: Agilent N8480 Series Thermocouple Power Sensors Data Sheet The N8480 Series thermocouple power sensors are amongst Agilent’s most accurate and reliable sensors. These will eventually replace the 8480 Series thermocouple range — only better with EEPROM and extended


    Original
    PDF N8480 N1911A/12A) E4416A/17A) N1913A/14A, E4418B/19B) 5989-9333EN N8481A Diode Sensors N1917C W8486A n8487A E4410 E9301B agilent CFT 455 n-type connector male

    Untitled

    Abstract: No abstract text available
    Text: Agilent E4418B/E4419B EPM Series Power Meters, E-Series and 8480 Series Power Sensors Data Sheet Why Agilent’s power meters and sensors? ฀ ฀ ฀ ฀ ฀ ฀ 2 E4418B/9B EPM Series power meter: applications and compatible sensors for average power measurements


    Original
    PDF E4418B/E4419B E4418B/9B cdma2000Â 480A/B/H, 5965-6382E

    Untitled

    Abstract: No abstract text available
    Text: Agilent Power Meters and Power Sensors High performance solutions for peak and average power measurements Introducing Agilent Power Meters and Sensors Reliable, high-performing solutions Every power meter and sensor from Agilent consistently delivers great results.


    Original
    PDF BP-09-27-13) 5989-6240EN

    Untitled

    Abstract: No abstract text available
    Text: Agilent N8480 Series Thermocouple Power Sensors Data Sheet The N8480 Series thermocouple power sensors are amongst Agilent’s most accurate and reliable sensors, plus they include EEPROM, and extended frequency and power ranges. Features • High accuracy with


    Original
    PDF N8480 N8488A) N1911A/12A) E4416A/17A) N1913A/14A, E4418B/19B) N8488A 5989-9333EN

    437B

    Abstract: No abstract text available
    Text: Agilent E1416A Power Meter Data Sheet 1-Slot, C-size, message based Single channel • ± 0.02 dB or ± 0.5% instrumentation accuracy • 100 kHz to 110 GHz, sensor dependent • –70 to +44 dBm • 1 mW power reference • • Description The Agilent Technologies E1416A Power Meter is a C-size,


    Original
    PDF E1416A E1416A 5564E 437B