Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    R8486 Search Results

    SF Impression Pixel

    R8486 Price and Stock

    Keysight Technologies R8486D

    RF Test Equipment Waveguide Power Sensor, 26.5 to 40 GHz, -70 to -20 dBm
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Mouser Electronics R8486D
    • 1 $13608
    • 10 $13608
    • 100 $13608
    • 1000 $13608
    • 10000 $13608
    Get Quote
    TestEquity LLC R8486D
    • 1 $13608
    • 10 $13608
    • 100 $13608
    • 1000 $13608
    • 10000 $13608
    Buy Now

    Agilent Technologies Inc R8486D

    R8486D/Waveguide Power Sensor, 26.5 To 40 Ghz, -70 To -20 Dbm Rohs Compliant: Na |Keysight Technologies R8486D
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Newark R8486D Bulk 1
    • 1 $13608
    • 10 $13608
    • 100 $13608
    • 1000 $13608
    • 10000 $13608
    Buy Now

    YAGEO Corporation RT0805BRD071ML

    Thin Film Resistors - SMD 1M ohm 0.1% 1/8W
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI RT0805BRD071ML Reel 5,000 5,000
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 $0.0202
    Buy Now

    Littelfuse Inc RF1691-000

    Resettable Fuses - PPTC 9V 100A 3.2Ohms
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI RF1691-000 Reel 4,000
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 $0.179
    Buy Now

    R8486 Datasheets (3)

    Part ECAD Model Manufacturer Description Curated Datasheet Type PDF
    R8486 Hamamatsu PHOTOMULTIPLIER TUBE Original PDF
    R8486A Agilent Technologies R8486A Thermocouple Waveguide Power Sensor, 26.5 GHz to 40 GHz Original PDF
    R8486D Agilent Technologies R8486D Waveguide Power Sensor, 26.5 GHz to 40 GHz Original PDF

    R8486 Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    E678-11A

    Abstract: R8486 R8487 F2222 B11-88
    Text: PHOTOMULTIPLIER TUBES PRELIMINARY DATA FEB. 2001 R8486, R8487 For Vacuum Ultraviolet Light Detection Cs-Te R8486 , Cs-I (R8487) Photocathode, MgF2 Window, 28 mm (1-1/8 Inch) Diameter, 9-stage, Side-on Type FEATURES Sensitivity in the Vacuum Ultraviolet Region


    Original
    R8486, R8487 R8486) R8487) R8486. R8487. R8486 E678-11A R8486 R8487 F2222 B11-88 PDF

    Untitled

    Abstract: No abstract text available
    Text: PHOTOMULTIPLIER TUBES R8486, R8487 For Vacuum Ultraviolet Light Detection Cs-Te R8486 , Cs-I (R8487) Photocathode, MgF2 Window, 28 mm (1-1/8 Inch) Diameter, 9-stage, Side-on Type FEATURES ● Sensitivity in the Vacuum Ultraviolet Region R8486.115 to 320 nm


    Original
    R8486, R8487 R8486) R8487) R8486. R8487. R8486 PDF

    OV10630

    Abstract: GCM32ER71C226KE19L
    Text: DS90UB913A-CXEVM & DS90UB914A-CXEVM REV A User's Guide User's Guide Literature Number: SNLU135 JUNE 2013 Chapter 1 SNLU135 – JUNE 2013 Introduction 1.1 Overview The Texas Instruments DS90UB913A-CXEVM & DS90UB914A-CXEVM REV A Evaluation Modules EVM provides an easy way to evaluate the operation and performance of the DS90UB913AQ /


    Original
    DS90UB913A-CXEVM DS90UB914A-CXEVM SNLU135 DS90UB914A-CXEVM DS90UB913AQ DS90UB914AQ DS90UB913A-CXEVM OV10630 GCM32ER71C226KE19L PDF

    3x1 berg connector

    Abstract: sw dip-2 Diode smd s4 2g 269147-2 diode smd marked s4 SMD diode s26 MX045 smd 1A4 t1A smd smd schottky diode s4 35
    Text: LXD973 PQFP MII Demo Board Development Kit Manual May 2001 Order Number: 249719-001 For technical assistance on this product, please call 1-800-628-8686, or send an e-mail to support@mailbox.intel.com Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual


    Original
    LXD973 TP12SH8AQE H1200 TP5-52, LXT973 IC149-100-014-S5 74LVX14 TC74LVX14FN 74LVC244 SN74LVC244ADW 3x1 berg connector sw dip-2 Diode smd s4 2g 269147-2 diode smd marked s4 SMD diode s26 MX045 smd 1A4 t1A smd smd schottky diode s4 35 PDF

    Digital Panel Meter PM 128

    Abstract: Digital Panel Meter PM 129 8484a 8900C E4416A 8481D 11730A power sensor cable 11730A E4418A E4418B
    Text: 01SEC027_IN.QXD 9/6/00 2:13 PM Page 303 Power Meters Peak and Average Power Meters • Peak, peak-to-average ratio and average power measurements • Time-gated power measurements • Fast measurement speed over the GPIB up to 1,000 readings per second with the E4416A and E9320 power sensors


    Original
    01SEC027 E4416A E9320 RS-232/422 E4417A E932X UG-599/U Digital Panel Meter PM 128 Digital Panel Meter PM 129 8484a 8900C 8481D 11730A power sensor cable 11730A E4418A E4418B PDF

    R1306

    Abstract: c7319 R720501 HAMAMATSU E849 e717-63 R928, hamamatsu
    Text: Photomultiplier Tubes PHOTOMULTIPLIER TUBES AND RELATED PRODUCTS Opening The Future with Photonics Human beings obtain more than 70 percent of the information visually by using their eyes. However, there are vast sums of information and unknown possibilities hidden within light not visible to the naked eye. This kind of light


    Original
    B-1348 E-08290 TPMZ0001E01 R1306 c7319 R720501 HAMAMATSU E849 e717-63 R928, hamamatsu PDF

    E4418B

    Abstract: E4419B E4419 V8486A E441xB-915 E4412A E9300 700PW E441xB-909 ISO calibration certificate formats
    Text: Agilent E4418B/E4419B EPM Series Power Meters, E-Series and 8480 Series Power Sensors Data Sheet Why Agilent’s power meters and sensors? [|t;C|[P³rtjrs[§f‰§t„j³ª‰|¾µt‰„ª Ä[§È³‰Å[§³[µ[§³;„S³ª[„ª‰§³f§‰³jt|[„µ³M‰„ªtªµ[„µ|ȳS[|tÄ[§ª³j§[;µ³§[ª¾|µª•³


    Original
    E4418B/E4419B E4418B/9B cdma2000® 480A/B/H, N8480A/B/H, R/Q8486A, N8486AR/AQ 5965-6382E E4418B E4419B E4419 V8486A E441xB-915 E4412A E9300 700PW E441xB-909 ISO calibration certificate formats PDF

    Untitled

    Abstract: No abstract text available
    Text: Agilent N1913A and N1914A EPM Series Power Meters E-Series and 8480 Series Power Sensors Consistent Results and Greater Capability Data Sheet As signals become more complex, it becomes more difficult to make fast, accurate power measurements. For years, you’ve depended on Agilent’s


    Original
    N1913A N1914A E4418B/19B BP-3-1-13) 5990-4019EN PDF

    Untitled

    Abstract: No abstract text available
    Text: Agilent V3500A Handheld RF Power Meter Data Sheet The first palm-sized power meter from Agilent Technologies that delivers high lab quality RF power measurements for installation and maintenance or R&D lab environments Why Agilent’s Power Meters and Sensors?


    Original
    V3500A 5990-5483EN PDF

    Untitled

    Abstract: No abstract text available
    Text: Agilent N1913A and N1914A EPM Series Power Meters E-Series and 8480 Series Power Sensors Consistent Results and Greater Capability Data Sheet As signals become more complex, it becomes more difficult to make fast, accurate power measurements. For years, you’ve depended on Agilent’s


    Original
    N1913A N1914A E4418B/19B 5990-4019EN PDF

    8485A

    Abstract: e4412a service manual 8481A E4418B E4413A e4412a 11730A 8481D 8482B R8486A
    Text: Agilent EPM Series Power Meters E-Series and 8480 Series Power Sensors Data Sheet Product specifications and characteristics EPM series E4418B and E4419B power meters Specifications Accuracy Specifications describe the instrument’s warranted performance and


    Original
    E4418B E4419B 5965-6382E 8485A e4412a service manual 8481A E4413A e4412a 11730A 8481D 8482B R8486A PDF

    11730A

    Abstract: HP8481H 8481B 8481H apc-7 connector 11730B japanese diode manual HPE1416A E1416A 8485A
    Text: PDFINFO H5 5 6 4 - 0 1 Power Meter HP E1416A Technical Specifications ● ● ● ● ● Single channel ± 0.02 dB or ± 0.5% accuracy 100 kHz to 100 GHz –70 to + 44 dBm 1 mW power reference Description The HP E1416A Power Meter is a C-size, 1-slot, message-based VXI module. It is a high-performance,


    Original
    E1416A E1416A 8482B 8482B 8481H 8481H 8482H 8482H 11730A HP8481H 8481B apc-7 connector 11730B japanese diode manual HPE1416A 8485A PDF

    Untitled

    Abstract: No abstract text available
    Text: Agilent N1913A and N1914A EPM Series Power Meters E-Series and 8480 Series Power Sensors Consistent Results and Greater Capability Data Sheet As signals become more complex, it becomes more difficult to make fast, accurate power measurements. For years, you’ve depended on Agilent’s


    Original
    N1913A N1914A E4418B/19B BP-3-1-13) 5990-4019EN PDF

    5990-5483EN

    Abstract: E9301B agilent N1922A zigbee temperature and humidity sensor E4413A how to test computer power supply using a meter 848X E9321A E441x
    Text: Agilent V3500A Handheld RF Power Meter Data Sheet The first palm-sized power meter from Agilent Technologies that delivers high lab quality RF power measurements for installation and maintenance or R&D lab environments Why Agilent’s Power Meters and Sensors?


    Original
    V3500A nee888 5990-5483EN 5990-5483EN E9301B agilent N1922A zigbee temperature and humidity sensor E4413A how to test computer power supply using a meter 848X E9321A E441x PDF

    11708a

    Abstract: N1913A E9300B N191xA-908 Diode Sensors W8486A 11730A E9304A N8481 N8481A
    Text: Agilent N1913A and N1914A EPM Series Power Meters Consistent results and greater capability Data Sheet ‘—‘`Ul!c‘— E3ogE—goŽE—3ogycE¦9—`™—)E3ogE‘— goŽE—<`NO3¢c™—™o—g!bE—N!‘™9—!33¢Ž!™E—yo¥EŽ— gE!‘¢ŽEgEl™‘~—oŽ—§E!Ž‘9—§o¢‹¤E—<EyEl<E<—


    Original
    N1913A N1914A N1914A N1913A/14A CDMA2000 11a/b/g 5990-4019EN 11708a E9300B N191xA-908 Diode Sensors W8486A 11730A E9304A N8481 N8481A PDF

    Untitled

    Abstract: No abstract text available
    Text: Agilent E4418B/E4419B EPM Series Power Meters, E-Series and 8480 Series Power Sensors Data Sheet Why Agilent’s power meters and sensors? ฀ ฀ ฀ ฀ ฀ ฀ 2 E4418B/9B EPM Series power meter: applications and compatible sensors for average power measurements


    Original
    E4418B/E4419B E4418B/9B cdma2000Â 480A/B/H, 5965-6382E PDF

    Untitled

    Abstract: No abstract text available
    Text: Agilent Power Meters and Power Sensors High performance solutions for peak and average power measurements Introducing Agilent Power Meters and Sensors Reliable, high-performing solutions Every power meter and sensor from Agilent consistently delivers great results.


    Original
    BP-09-27-13) 5989-6240EN PDF

    Untitled

    Abstract: No abstract text available
    Text: Agilent N8480 Series Thermocouple Power Sensors Data Sheet The N8480 Series thermocouple power sensors are amongst Agilent’s most accurate and reliable sensors, plus they include EEPROM, and extended frequency and power ranges. Features • High accuracy with


    Original
    N8480 N8488A) N1911A/12A) E4416A/17A) N1913A/14A, E4418B/19B) N8488A 5989-9333EN PDF

    437B

    Abstract: No abstract text available
    Text: Agilent E1416A Power Meter Data Sheet 1-Slot, C-size, message based Single channel • ± 0.02 dB or ± 0.5% instrumentation accuracy • 100 kHz to 110 GHz, sensor dependent • –70 to +44 dBm • 1 mW power reference • • Description The Agilent Technologies E1416A Power Meter is a C-size,


    Original
    E1416A E1416A 5564E 437B PDF