dc-dc converter 12v 500mA -16v 4.5A
Abstract: EN61373 EN61000-4-4 PMT-048 IEC60950-1 7200F RAILWAY FIXED EQUIPMENT
Text: FEATURES • 15 WATTS OUTPUT POWER • OUTPUT CURRENT UP TO 4.5A • STANDARD 2.0 X 1.0 X 0.4 INCH PACKAGE • HIGH EFFICIENCY UP TO 88% • 4:1 ULTRA WIDE INPUT VOLTAGE RANGE • SIX-SIDED CONTINUOUS SHIELD • FIXED SWITCHING FREQUENCY • RAILWAY APPLICATION
|
Original
|
PDF
|
2006/95/EC,
93/68/EEC
2004/108/EC
UL60950-1,
EN60950-1
IEC60950-1
ISO9001
2002/95/EC
FEC15W
FEC1524XXXW
dc-dc converter 12v 500mA -16v 4.5A
EN61373
EN61000-4-4
PMT-048
7200F
RAILWAY FIXED EQUIPMENT
|
1i03
Abstract: 501-2132 EN50155 217F MPF330
Text: www.martekpower.com MPF 330 & MPF 420 SERIES NON-ISOLATED DC/DC CONVERTERS >Description The MPF 330 W and MPF 420 W are non isolated DC/DC converters designed to power the headlights, windshield wipers or other equipments on board trains. They allow the adaptation of railway approved 72 V input products into a 110 V input. Inputs are available
|
Original
|
PDF
|
|
RADOX POWER CABLE
Abstract: RADOX 125 1.5 MM2 radox 125 current
Text: Railway products Edition 2013 Bridging our technologies Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical interconnectivity components and systems. Our main markets are communication, transport and industry. Under one roof, we combine
|
Original
|
PDF
|
|
MTBF transil
Abstract: No abstract text available
Text: www.martekpower.com www.martekpower.fr CER 300, 400 DC/DC CONVERTER > Description Designed to supply railway equipments, this isolated DC/DC converter is a 3U Europe card that fits in the CRR 1K5 rack. This converter is compliant with railway standards. > Input Specifications
|
Original
|
PDF
|
HDBK217F)
MTBF transil
|
IEC571
Abstract: RIA12 EN50155 336V IRFD110 application IRFP450 dc to dc converter from 110V to 24V RAILWAY FIXED EQUIPMENT 110VN IRFP450 Power Mosfet
Text: Application Note Using Modular DC-DC Converters to Meet European Standards for Railway Applications In Europe, the performance of electrical and electronic equipment in railway applications is governed by two international standards. Electrical Requirements
|
Original
|
PDF
|
EN50155
IEC571)
IEC571,
EN50155,
RIA12,
IEC571
RIA12
EN50155
336V
IRFD110
application IRFP450
dc to dc converter from 110V to 24V
RAILWAY FIXED EQUIPMENT
110VN
IRFP450 Power Mosfet
|
RADOX CABLE 125
Abstract: RADOX 125 1.5 MM2 siemens standard bogie RADOX 125 1.5 MM SMA-50-3-55/199 11_SMA-50-3-55/199_NE RADOX CABLE
Text: Railway products Edition 2014 Bridging our technologies Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical interconnectivity components and systems. Our main markets are communication, transport and industry. Under one roof, we combine
|
Original
|
PDF
|
|
A16102
Abstract: Souriau* 8p
Text: Railway UTS Lightweight and sealed The solution for indoor applications using 1 standard AWG16 contact Secure for indoor applications Flame retardant material Water jet & underwater proof IP68/IP69K Easy to handle Ergonomic design Wire sealing
|
Original
|
PDF
|
IP68/IP69K
02W2S
42G1S
WINDUTSRWO02ENà
A16102
Souriau* 8p
|
28SH6
Abstract: No abstract text available
Text: Railway UTO High density shielded connector The solution for indoor applications using 1 standard AWG16 contact Standardization oriented Compliant to railway fire & smoke standards A unique #16 contact for 11 layouts I2F3 according to NFF16-101 NFF 16-102
|
Original
|
PDF
|
NFF16-101
UTOS22JCSL
UTOS22JCL
UTOS24JCSL
UTOS24JCL
WINDUTORWO02EN
28SH6
|
ABB STOTZ-KONTAKT S 211
Abstract: HC-49/ABB STOTZ-KONTAKT S 211
Text: Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31 and CM-PVS.41 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage. Characteristics –– Monitoring of three-phase mains for phase sequence
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.21 and CM-MPS.41 Characteristics –– Monitoring of three-phase mains for phase sequence can be switched off , phase failure, over- and undervoltage as well as phase unbalance –– TRMS measuring principle
|
Original
|
PDF
|
|
3 phase monitoring relays
Abstract: No abstract text available
Text: Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. Characteristics –– Monitoring of three-phase mains for phase sequence and
|
Original
|
PDF
|
V0012
3 phase monitoring relays
|
Untitled
Abstract: No abstract text available
Text: Railway UTS Lightweight and sealed The solution for indoor applications using 1 standard AWG16 contact Secure for indoor applications Flame retardant material Water jet & underwater proof IP68/IP69K Easy to handle Ergonomic design Wire sealing
|
Original
|
PDF
|
IP68/IP69K
02W2S
42G1S
WINDUTSRWO02EN
|
grommet connector
Abstract: UTS6jc1823s UTS0104S 18-23P QUADRAX CABLE UTS6JC147S UTS1JC147S AWG16 KV-24 dr UTS6JC1823P
Text: Railway UTS Lightweight and sealed The solution for indoor applications using 1 standard AWG16 contact Secure for indoor applications Flame retardant material Water jet & underwater proof IP68/IP69K Easy to handle Ergonomic design Wire sealing
|
Original
|
PDF
|
IP68/IP69K
02W2S
42G1S
WINDUTSRWO01EN
grommet connector
UTS6jc1823s
UTS0104S
18-23P
QUADRAX CABLE
UTS6JC147S
UTS1JC147S
AWG16
KV-24 dr
UTS6JC1823P
|
Untitled
Abstract: No abstract text available
Text: Rail transportation isolated DC-DC Converters Railway Power Supply Rail transportation isolated DC-DC converters DC-DC Converter Key Performance Highlights SynQor’s RailQor line of DC-DC converters is designed to provide isolated DC power in the transportation industry for such electronics
|
Original
|
PDF
|
|
|
Untitled
Abstract: No abstract text available
Text: IBX15 Series Data Sheet Boost Converters Features 54.9 2.16" 54.9 2.16" • • • • • • • • • • 11.5 0.45" RoHS compliant for all 6 substances Wide input voltage range 8 to 160 VDC Output: 30 to 80 VDC Class III equipment no isolation input/output
|
Original
|
PDF
|
IBX15
02-Dec-2013
|
UTO62235SH
Abstract: UTO62448SH UTO62235PH 18-23P UTOS20JCSL UTO24AC Souriau* 8p UTO16AC UTO62028PH UTO12AC
Text: Railway UTO High density shielded connector The solution for indoor applications using 1 standard AWG16 contact Standardization oriented Compliant to railway fire & smoke standards A unique #16 contact for 11 layouts I2F3 according to NFF16-101 NFF 16-102
|
Original
|
PDF
|
NFF16-101
UTOS22JCSL
UTOS22JCL
UTOS24JCSL
UTOS24JCL
WINDUTORWO01EN
UTO62235SH
UTO62448SH
UTO62235PH
18-23P
UTOS20JCSL
UTO24AC
Souriau* 8p
UTO16AC
UTO62028PH
UTO12AC
|
Untitled
Abstract: No abstract text available
Text: www.martekpower.com MPF 3K0 1I01 DC/AC INVERTER >Description The 3kVA railway application inverter provides 230 VAC power to train passengers. It has an input of 110 VDC and an output of 230 VAC 50Hz. It is fan cooled and complies with railway standards EN 50155 and EN 50121-3-2. Its standard size facilitates its integration
|
Original
|
PDF
|
|
QwikConnect October 2007
Abstract: No abstract text available
Text: Qwik Connect G L E N A I R OCTOBER 2007 V O L U M E 11 N U M B E R Take The “A” Train! Glenair Has the Connectors, the Cables and the Expertise to Solve Even the Toughest Rail Industry Interconnect Challenges 4 QwikConnect Take the “A” Train: Connectors, Cables and World-Class Interconnect
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: 120W DC/DC Converter for Railway Applications Features • Very low profile Very high efficiency typically 90% Single and dual output versions Input voltages from 24V to 110VDC nominal Output voltages from 5V to 48VDC -40°C to +71°C operation without de-rating
|
Original
|
PDF
|
110VDC
48VDC
EN50155
EN50121-3-2
|
Untitled
Abstract: No abstract text available
Text: FEATURES • RAILWAY APPLICATION • 20 WATTS MAXIMUM OUTPUT POWER • ULTRA LOW QUIESCENT CURRENT • SINGLE OUTPUT UP TO 4.5A • STANDARD 2.00 X 1.00 X 0.40 INCH • HIGH EFFICIENCY UP TO 89% • 4:1 ULTRA WIDE INPUT VOLTAGE RANGE • SIX-SIDED CONTINUOUS SHIELD
|
Original
|
PDF
|
2006/95/EC,
93/68/EEC
2004/108/EC
UL60950-1,
EN60950-1,
IEC60950-1
EN50155
2002/95/EC
RED20W
|
Untitled
Abstract: No abstract text available
Text: FEATURES • RAILWAY APPLICATION • 20 WATTS MAXIMUM OUTPUT POWER • ULTRA LOW QUIESCENT CURRENT • SINGLE OUTPUT UP TO 4.5A • STANDARD 2.00 X 1.00 X 0.40 INCH • HIGH EFFICIENCY UP TO 89% • 4:1 ULTRA WIDE INPUT VOLTAGE RANGE • SIX-SIDED CONTINUOUS SHIELD
|
Original
|
PDF
|
2006/95/EC,
93/68/EEC
2004/108/EC
UL60950-1,
EN60950-1,
IEC60950-1
EN50155
2002/95/EC
RED20W
|
Untitled
Abstract: No abstract text available
Text: HR/HRP Series Data Sheet 240/288 Watt DC-DC Converters, 10:1 Input Range Features • Extremely wide input voltage range from 12 to 168 VDC in the same model • RoHS compliant • Class I equipment • Input over- and programmable undervoltage lockout
|
Original
|
PDF
|
MOUNTINGPLATE-K02
14-Sep-2012
|
Untitled
Abstract: No abstract text available
Text: DATASHEET Rev. A DCREDUW20 SERIES 4:1 Ultra Wide Input Voltage Range Single and Dual Outputs Standard 2.0” x 1.0” x 0.4” Package 20 Watt DC/DC Power Converters FEATURES • Railway Applications Single and Dual Outputs Industry Standard 2.00” x 1.00” x 0.40” Package
|
Original
|
PDF
|
DCREDUW20
1600VDC
|
kXJ Series
Abstract: pmt-050 RAILWAY FIXED EQUIPMENT EN61373 nippon kxj chemi-con capacitor KXJ
Text: DATASHEET Rev. D LANCUW8 SERIES 4:1 Ultra Wide Input Voltage Ranges Single and Dual Outputs SMT and DIP Packages 8 Watt DC/DC Power Converters FEATURES • Single and Dual Outputs 4:1 Ultra Wide Input Voltage Ranges High Efficiency up to 88% 8 Watts Output Power
|
Original
|
PDF
|
1600VDC
300KHz)
2002/95/EC
2006/95/EC,
93/68/EEC
2004/108/EC
UL60950-1,
EN60950-1,
IEC60950-1,
EN50155
kXJ Series
pmt-050
RAILWAY FIXED EQUIPMENT
EN61373
nippon kxj
chemi-con capacitor KXJ
|