Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    RXZF 21 Search Results

    RXZF 21 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    RAZFE

    Abstract: distance relay single phase to three phase convertor RXKE 1
    Text: RFA 80-11-20 Edition 2 RF 556-00<f Page 1 Three phase power swing unit with impedance relay type RXZF 2 for co-operation with distance relay type RAZFE and reclosing relay_ ENCLOSURES List of apparatus Circuit diagram Terminal diagram sat; 7*01 *c ititi it io a ooo.i


    OCR Scan
    PDF 012-D 012-G 012-E 675-DP RAZFE distance relay single phase to three phase convertor RXKE 1

    over current relay

    Abstract: ASEA relay - RXZ transformer protection relay about the dc relay
    Text: ASEA C A N C tU » Information RK 556-300 E Edition 2 November 1974 rile RK 00-90 £,-Section 5 Relay División Impedance r e l a y t y p e RXZF 2 KXZF 2 i s a s t a t i c impedance m easuring r e l a y t which has s h o r t o p e r a t i n g time and low power consum ption.


    OCR Scan
    PDF 001-AA 00L-C 001-D 5S6-300 over current relay ASEA relay - RXZ transformer protection relay about the dc relay

    MVA generator

    Abstract: RXPE 40 5 MVA generator RXPE 4 5 MVA synchronous machine B03-9540E t 319 5 MVA generator synchronous 1RF640 about the dc relay
    Text: A » 1 1 » • I V 1NFORM Al'loH FiF U 0 021E TIL, tiOVH Edition 1 n u t - o f - s t o p r e l ay t o r tiv n ^ h ionous machine-; Q u t - o f - s t e p o ^ r a t i o n m e a u that. t-he m a c h in e w i t h i n t a c t f i e l d i s tunuir.q out o f s y n c h r o n i s m wj lh t h e


    OCR Scan
    PDF 0105-AB uJ22S, MVA generator RXPE 40 5 MVA generator RXPE 4 5 MVA synchronous machine B03-9540E t 319 5 MVA generator synchronous 1RF640 about the dc relay

    RXPE 4

    Abstract: RXPE 40 synchronous motor 11 MVA 5 MVA generator synchronous MVA generator Synchronism check relay B03-9540E 20 MVA generator 5 MVA synchronous machine about the dc relay
    Text: INFORMATION RF 640 02IE 1# HL, Nov. 1988 Edition 1 Out-of-step relay for synchronous machines Out-of-step operation means that the machine with intact field is running out of synchronism with the network. During the out-of-step condition, the machine current varies heavily as the rotor machine


    OCR Scan
    PDF

    B03-3211E

    Abstract: RELAY AG 105 21 rxms1 transformer faults BROWN BOVERI DISTANCE RELAYS rxms1 abb B03-3210 BROWN BOVERI connection diagram brown boveri b033210 relay 24v AC transformer
    Text: Ik » » 1 1 Type RXZF21 f | | | | B03-32106 r Pagel Single-phase im pedance relay ASEA BROWN BOVERI ABB Relays Data subject to change without notice r CANCELLED ' Abstract - . ••‘ 1 « « • • « • if . ' I • Jumper selectable circular or oval operat­


    OCR Scan
    PDF B03-3210 B03-3211E B03-1210E B03-9301E B03-1213E B03-9382E S-721 RELAY AG 105 21 rxms1 transformer faults BROWN BOVERI DISTANCE RELAYS rxms1 abb BROWN BOVERI connection diagram brown boveri b033210 relay 24v AC transformer

    K8602

    Abstract: RXPE 40 B03-3013 asea directional relay RXPE 40 ASEA relay RXMA 1 about the dc relay
    Text: ASEA RELAYS INFORMATION RF 64 0-0 11 RFA, January 1986 Edition 3 1 O ut-of-step relay for synchronous generators and motors G ENERAL Out- of- st ep operation means that, the machine with in ta c t field is running out of synchronism with the network. During the outof-step condition, the machine current varies heavily as the


    OCR Scan
    PDF B03-3210. 74320105-AAÂ 01OS-AA K8602 RXPE 40 B03-3013 asea directional relay RXPE 40 ASEA relay RXMA 1 about the dc relay

    brown boveri rakza

    Abstract: BROWN BOVERI relay differential B03-9301E BROWN BOVERI relay BROWN BOVERI ASEA rk 651
    Text: il 11II M l l l l SEA b r o w n B O R _ _ ABB Relays Abstract Application TvDe RAKZA * Three-phase impedance relay • Circular operating characteristic • Operate value adjustable between 4—174


    OCR Scan
    PDF B03-1003E B03-9301E 221-AA 221-BA B03-3210E B03-1210E B03-1613E B03-9510E B03-9382E brown boveri rakza BROWN BOVERI relay differential BROWN BOVERI relay BROWN BOVERI ASEA rk 651

    BROWN BOVERI DISTANCE RELAYS

    Abstract: ranzp BROWN BOVERI relay RXTUG 2H brown boveri distance B03-9301E
    Text: _ 11 l i *IPIP ASEA BROWN BOVE RI ABB Relays Abstract v Type RANZP Power-swing-blocking relay B03-7111E Rage 1 May 1983 Data subject to change without notice • Characteristic angle 80° • Setting range 2—87 ohms in 3.5—5 % steps • Reconnectible for 1 A, 2 A or 5 A rated


    OCR Scan
    PDF B03-7111E B03-9301E B03-3210E B03-9112E B03-9382E S-721 BROWN BOVERI DISTANCE RELAYS ranzp BROWN BOVERI relay RXTUG 2H brown boveri distance

    BROWN BOVERI DISTANCE RELAYS

    Abstract: RAZOG distance relay BROWN BOVERI relay distance RXMS 002-AA ABB RAAAM ABB RELAY - RAAAM raaam relay RXKE 1
    Text: V Al l i l i A* IP IP ASEA BROWN BOVERI ABB Relays Type RAZOG B03-7013E Three-zone, phase and ground distance relay for transmission lines Abstract Application Data subject to change without notice >Three-phase and ground sequential mea­ surement distance relay for overhead lines


    OCR Scan
    PDF B03-7013E B03-7013E B03-1003E B03-9151E B03-1613E B03-3210E B03-9113E B03-8010E B03-8014E B03-9510E BROWN BOVERI DISTANCE RELAYS RAZOG distance relay BROWN BOVERI relay distance RXMS 002-AA ABB RAAAM ABB RELAY - RAAAM raaam relay RXKE 1

    cubicles catalogue

    Abstract: RAKZA 004-AA 92-10E ASEA PLUG IN RELAY RXKB 1
    Text: ASEA Catalogue RK 65-52 E Edition 1 Septem ber 1977 File Ft, Part 1 Three-phase impedance-measuring protective relay type RAKZA * Circular impedance characteristic * Adjustable operating time * Operating value adjustable in stages of 3 - 5 % in the range of 4—154 f!


    OCR Scan
    PDF RK651 21-AA 92-10E RK33-11 S-721 cubicles catalogue RAKZA 004-AA 92-10E ASEA PLUG IN RELAY RXKB 1

    ASEA motor

    Abstract: RXPE40 RXMH-2 RXMK1 ASEA brown boveri protection relay ABB RXMVB2 instantaneous overcurrent relay BROWN BOVERI motor protection relay RXIDF 2H asea directional relay
    Text: A »11 ASEA BROWN BOVERI ABB Relays Index of IEEE device function numbers with associated ASEA relays B03-0312E Page 1 January 1985 Changed sin ce M ay 1983 Ref: ANSI/IEEE C37.2-1979 Device number Function Type B03 number 2 Time-delay starting or closing relay


    OCR Scan
    PDF B03-0312E B03-1611E -1612E -1613e -1614e -1610e -8112e -8320e -8321e -3211e ASEA motor RXPE40 RXMH-2 RXMK1 ASEA brown boveri protection relay ABB RXMVB2 instantaneous overcurrent relay BROWN BOVERI motor protection relay RXIDF 2H asea directional relay

    RXSF1

    Abstract: protection relay type racic RXIDF 2H RXEL22 ASEA relay - RAKZB rxsf-1 ABB RXsf1 RXEG21 ASEA motor brown boveri dc motor
    Text: Jk nil M l » » ASEA BROWN BOVERI 303 ^ 3 ^ ^ ABB Relays January 1985 Function Type B03 num b! AC-DC converter, 20 W AC conversion unit for RXKE 1 time-delay relay All or nothing relays, instantaneous, see auxiliary relays


    OCR Scan
    PDF B03-0310E -7016e -7017e -2031e -2531e -2011e -2032e -2033e -2034e -2910e RXSF1 protection relay type racic RXIDF 2H RXEL22 ASEA relay - RAKZB rxsf-1 ABB RXsf1 RXEG21 ASEA motor brown boveri dc motor

    RAZOG

    Abstract: CI 7433 RXKO2 raaak Thyristor pulse transformer AEG asea thyristor pr 16 RXIH 2 ASEA thyristor thyristor aeg asea relay RI
    Text: Inie-No, AS EA RK 615-302 E Rag. Page 7433 1 Filé RK 00-90 E Section 6 IHF0EMATI0H From/Dal« R3?R, Dec. 1975 Edit ioti 1 Reiay Division Distance relay type KAZOG o Static three-phase design o Switched scheme o Minimum operating time 20 m3 o Suitable for both overhead


    OCR Scan
    PDF 0040-C 527I20Ã RAZOG CI 7433 RXKO2 raaak Thyristor pulse transformer AEG asea thyristor pr 16 RXIH 2 ASEA thyristor thyristor aeg asea relay RI