Untitled
Abstract: No abstract text available
Text: 8 6 7 4 5 + 2 HOUSING: SB50-SERIES 3 PRONG PCB CONTACT TWO REQUIRED : ECRN 13418- .25 TYP WAS .21 TYP NOSE OF CONTACT 1 = ASSEMBLED HOUSING AND CONTACTS SB-PCB-SERIES D OPENING OF HOUSING 35.1 1.38 3.7 .14 2 PLCS 1 C REV. DESCRIPTION OF CHANGES BY: DATE CMS
|
Original
|
SB50-SERIES
114197S1
CADFILES/01121
SB50-SERIES
|
PDF
|
connector SB50 anderson
Abstract: anderson SB50 SB50 anderson SB50 cms 25 11 114332S1
Text: 8 5 6 7 1 APPLICATION D 17.6 .69 MINI-VERTICAL POWERCLAW CONTACTS 35.4 1.40 C GUIDE HOUSING 1 REV. C 2 SB50 CONNECTOR 38.5 1.52 ECRN 14249: ADDED MATING LENGTH DATE DESCRIPTION OF CHANGES BY: D CMS 3/26/08 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF
|
Original
|
WIT02
UL94V-0,
CADFILES/01686
114332S4
connector SB50 anderson
anderson SB50
SB50 anderson
SB50
cms 25 11
114332S1
|
PDF
|
anderson SB50
Abstract: No abstract text available
Text: Anderson Power Products ® General Installation Instructions for the Vertical & Horizontal Powerclaw with Guide Housing See reverse side for mounting location/dimensions 1. By applying slight pressure, insert the Vertical Powerclaw contact(s) through the
|
Original
|
1S6401
REV02
anderson SB50
|
PDF
|
SB50-HDL-RED
Abstract: anderson sbs50 SBS50 SBS75X anderson sbs75X anderson SB50 connector SB50 anderson self tapping screws sb50 SB50 anderson
Text: 8 6 7 5 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ANDERSON POWER PRODUCTS. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF ANDERSON POWER PRODUCTS IS PROHIBITED. D 2 SELF-TAPPING SCREWS 3 4 2 1 ANDERSON POWER PRODUCTS RESERVES THE RIGHT TO ALTER PRODUCT TYPES,
|
Original
|
SBS50,
SBS75X)
SBS75X
SB50-HDL-RED)
113923S1
SB50-HDL-RED
anderson sbs50
SBS50
anderson sbs75X
anderson SB50
connector SB50 anderson
self tapping screws
sb50
SB50 anderson
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SB Connectors The Anderson Pow er SB Connector Concept Anderson Power Products® SB® 2 pole connector is available in 50, 175, and 350 amps ratings for use to 600 Volts continuous AC or DC operation. Mechanical keys molded into connectors of the same color
|
OCR Scan
|
MA01564
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SB 50 Connectors - up to 120 amps Based off the design pioneered by Anderson in 1953, APP®’s two pole SB® connectors set the standard for DC power distribution and battery connections. SB®50 connectors feature a one piece plastic housing using stainless steel springs to hold low resistance contacts in
|
Original
|
SB175
1303G13
1304G32
1387G1
1387G2
1388G3
1389G3
|
PDF
|
SBX350
Abstract: SB50 anderson
Text: SB Connectors The Anderson Power SB® Connector Concept Anderson Power Products® SB® 2 pole connector is available in 50, 175, and 350 amps ratings for use to 600 Volts continuous AC or DC operation. Mechanical keys molded into connectors of the same color
|
OCR Scan
|
SBX175
SBX350
SBE160
SB50 anderson
|
PDF
|
PC5930S
Abstract: MIL-STD-1344, Method 3001 PC5930T PC5930 PC5933S PC5933T PC5934S PC5934T cork material connector SB50 anderson
Text: Powerclaw Anderson Power Products 55 amp PCB Connector ® The innovative design of our Powerclaw family of connectors for the power electronics market makes connecting and disconnecting a snap, enabling safe and convenient "hot swapping*" during equipment maintenance
|
Original
|
LR25154
E26226
REV02
PC5930S
MIL-STD-1344, Method 3001
PC5930T
PC5930
PC5933S
PC5933T
PC5934S
PC5934T
cork material
connector SB50 anderson
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SB Connectors The Anderson Power SB? Connector Concept Anderson Power Products® SB® 2 pole connector is available in 50, 175, and 350 amps ratings for use to 600 Volts continuous AC or DC operation. Mechanical keys molded into connectors of the same color
|
OCR Scan
|
|
PDF
|
14308
Abstract: SB50 anderson
Text: 8 7 5 6 4 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ANDERSON POWER PRODUCTS. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF ANDERSON POWER PRODUCTS IS PROHIBITED. E 7.1 .28 6.9 .27 2 3 1 ANDERSON POWER PRODUCTS RESERVES THE RIGHT TO ALTER PRODUCT TYPES,
|
Original
|
PP75/SB50
B01952S1
14308
SB50 anderson
|
PDF
|
SB50
Abstract: DS-SB50
Text: SB 50 Connectors - up to 120 amps Based off the design pioneered by Anderson in 1953, APP®’s two pole SB® connectors set the standard for DC power distribution and battery connections. SB®50 connectors feature a one piece plastic housing using stainless steel springs to hold low resistance contacts in
|
Original
|
1388G7
SB120
1319G4
1388G3
1319G6
1323G1
1387G1
1388G4
SB175
300mcm
SB50
DS-SB50
|
PDF
|
SB175 anderson
Abstract: connector SB50 anderson UL-746C united chemical P913 P949 sb175 SB-175 ANDERSON POWER PRODUCTS SB175
Text: Chemical Resistant Anderson Power Products SB Connectors ® The new Chemical Resistant CR SB line of connectors were developed for customers whose applications require robust connector solutions that provide improved resistance to environmental factors that commonly
|
Original
|
g2-3700
SB175 anderson
connector SB50 anderson
UL-746C
united chemical
P913
P949
sb175
SB-175
ANDERSON POWER PRODUCTS SB175
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SB Connectors Accessories Handles Polycarbonate handle relieves unnecessary strain on cables when disconnecting. Catalog Number For Use With 995G1 SB175 1 handle & hardware 4 screws 4 lockwashers 4 nuts Gray 995G3 SB175 1 handle & hardware 4 screws 4 lockwashers
|
OCR Scan
|
995G1
SB175
995G3
995G2
SB350
995G4
SB50-HDL
|
PDF
|
UL 486A pull test
Abstract: UL486E table 14.1 UL486e UL 486A pull out test UL486B 1387G1 UL486 1388G4 1388g6 1388G5
Text: CRIMPING INSTRUCTIONS FOR CATALOG # 1387G1 PNEUMATIC CRIMP TOOL The 1387G1 is a heavy-duty pneumatic tool which crimps Anderson contacts with a wire range from #10/12 AWG to 4/0 cable. This tool is either bench mountable or portable and operates off of standard shop air pressure 90 to 125 psi . Interchangeable dies
|
Original
|
1387G1
1387G1
SB50/PP75
PP120
SB175/PP180
SB350
1388G6
UL 486A pull test
UL486E table 14.1
UL486e
UL 486A pull out test
UL486B
UL486
1388G4
1388g6
1388G5
|
PDF
|
|
SBE160
Abstract: SB175 6170G1 ANDERSON POWER PRODUCTS SB175 PP180 anderson SB350 anderson 114204S1 anderson SB50 CMS223 SB50 anderson
Text: 8 6 7 4 5 ECRN 14255: update talbe 4/18/08 AMS 10/01/07 CMS ECRN 14192: CORRECT METRIC TABLE CONVERSIONS 8/2/02 11/21/02 CMS CMS ECRN 13507 ECRN 13533 BY: DATE CMS 2/23/01 DJD 3/1/01 CONTACT BUSHING 1 2 3 4 5 6 6 1 D CABLE CATALOG NUMBER CONNECTOR SERIES FOR USE
|
Original
|
PP75/SB50
PP120/SB120
PP180/SB175
SBE160/SBX175
SBE160
SB175
6170G1
ANDERSON POWER PRODUCTS SB175
PP180 anderson
SB350 anderson
114204S1
anderson SB50
CMS223
SB50 anderson
|
PDF
|
1387G1
Abstract: crimping tool by manufacturer THHN WIRE 1S1030 connector SB50 anderson SB175 SB350 981G1 E26226 anderson SB50
Text: SB Connector Assembly Sheet For all models: 50, 120, 175 and 350 amps Two Pole Connectors with Single Piece Housings ASSEMBLY INSTRUCTIONS For installation by a qualified electrician in accordance with national and local electrical codes and the following instruction. The suitability of this type of termination must be
|
Original
|
E26226.
LR25154.
1S1030A
REV15
1387G1
crimping tool by manufacturer
THHN WIRE
1S1030
connector SB50 anderson
SB175
SB350
981G1
E26226
anderson SB50
|
PDF
|
PC5933T
Abstract: PC5930 PC5930S PC5930T PC5933S PC5934S PC5934T MIL-STD-1344, Method 3001
Text: 55 amp PCB Powerclaw Contacts The innovative design of our Powerclaw® family of connectors for the power electronics market makes connecting and disconnecting a snap, enabling safe and convenient "hot swapping*" during equipment maintenance without the need
|
Original
|
f2-3700
PC5933T
PC5930
PC5930S
PC5930T
PC5933S
PC5934S
PC5934T
MIL-STD-1344, Method 3001
|
PDF
|
anderson SB50
Abstract: No abstract text available
Text: MAT SPEC. COPPER ALLOY FINISH REVISIONS ELECTROLYTIC BRIGHT NICKEL 2 ECRN 13652 REV. & REDRWN DM 11/03 3 REVISED PER ECRN 14452 CHB 6/17/09 A .28 7.1 .14 3.5 .28 7.1 .43 10.9 1.18±.05 30.0±1.3 CATALOG NO. 1C0608P33 ANDERSON POWER PRODUCTS RESERVES THE RIGHT TO ALTER PRODUCT TYPES,
|
Original
|
1C0608P33
PP75/SB50
1C0608S33
anderson SB50
|
PDF
|
anderson SB50
Abstract: No abstract text available
Text: MAT SPEC. COPPER ALLOY FINISH SILVER PLATE REVISIONS 2 ECRN 13635 CHB 11/11/03 3 ECRN 13652 CHG RADIUS 12/03 4 REVISED PER ECRN 14452 CHB 6/17/09 A .28 7.1 .28 7.1 .19 4.8 .43 10.9 1.18±.05 30.0±1.3 CATALOG NO. 5952 ANDERSON POWER PRODUCTS RESERVES THE RIGHT TO ALTER PRODUCT TYPES,
|
Original
|
PP75/SB50
10mm2
114155S1
anderson SB50
|
PDF
|
6331G3
Abstract: 6319G1 6331G7 6331G1 6331G2 6331G4 6331G5 6331G6 6331G8 6331G9
Text: SB 50 Anderson Power Products Connector ® The innovative SB® connectors provide costeffective reliability, design flexibility and safety for your products' manufacture, installation and maintenance. APP's 2 pole connector is available with a 50 amp rating, 600 Volts continuous AC or DC
|
Original
|
1309G4
1387G1
1388G6
1388G7
1389G6
1389G7
260G16
284G1
250G5
E26226
6331G3
6319G1
6331G7
6331G1
6331G2
6331G4
6331G5
6331G6
6331G8
6331G9
|
PDF
|
1C0608S5
Abstract: 1 pp75
Text: 8 7 5 6 3 4 Copyright 2009 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ANDERSON POWER PRODUCTS. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF ANDERSON POWER PRODUCTS IS PROHIBITED. 2 1 ANDERSON POWER PRODUCTS RESERVES THE RIGHT TO ALTER PRODUCT TYPES,
|
Original
|
10/13NISH:
PP75/SB50
1C0608S5
1C0608S5
1 pp75
|
PDF
|
connector SB50 anderson
Abstract: 1309G4 anderson SB50
Text: SB 50 Anderson Power Products Connector ® The innovative SB® connectors provide cost-effective reliability, design flexibility and safety for your products' manufacture, installation and maintenance. APP's 2 pole connector is available with a 50 amp rating, 600 Volts continuous AC or DC
|
Original
|
DS-SB50
REV03
connector SB50 anderson
1309G4
anderson SB50
|
PDF
|
anderson SB50
Abstract: 5914 ANDERSON 5914
Text: 8 7 5 6 3 4 Copyright 2009 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ANDERSON POWER PRODUCTS. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF ANDERSON POWER PRODUCTS IS PROHIBITED. 2 1 ANDERSON POWER PRODUCTS RESERVES THE RIGHT TO ALTER PRODUCT TYPES,
|
Original
|
PP75/SB50
114100S1
anderson SB50
5914
ANDERSON 5914
|
PDF
|
Untitled
Abstract: No abstract text available
Text: C rim p T o o lin g Crimp Tooling fo r Anderson Connectors The cross reference tables on the following pages list the recommended crimp tool to use for each of our connectors. They are organized by connector type and divided for Anderson's loose piece con
|
OCR Scan
|
1353G1
250G1/250G2
280G1/280G2
260G1/260G3
260G16
250G5
284G1
260G14
260G15
|
PDF
|