Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SCHAFFNER POWER CHOKES Search Results

    SCHAFFNER POWER CHOKES Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DFE2016CKA-1R0M=P2 Murata Manufacturing Co Ltd Fixed IND 1uH 1800mA NONAUTO Visit Murata Manufacturing Co Ltd
    LQW18CN55NJ0HD Murata Manufacturing Co Ltd Fixed IND 55nH 1500mA POWRTRN Visit Murata Manufacturing Co Ltd
    LQW18CNR56J0HD Murata Manufacturing Co Ltd Fixed IND 560nH 450mA POWRTRN Visit Murata Manufacturing Co Ltd
    DFE322520F-2R2M=P2 Murata Manufacturing Co Ltd Fixed IND 2.2uH 4400mA NONAUTO Visit Murata Manufacturing Co Ltd
    LQW18CN4N9D0HD Murata Manufacturing Co Ltd Fixed IND 4.9nH 2600mA POWRTRN Visit Murata Manufacturing Co Ltd

    SCHAFFNER POWER CHOKES Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    Untitled

    Abstract: No abstract text available
    Text: Photovoltaics Cleaning up green power Grid compliance and reliability for photovoltaic systems Schaffner Group Schaffner is the international leader in the fields of electromagnetic compatibility and power quality, supplying components that support the efficient and reliable use of electric energy. Customers benefit from the technological know-how of the Schaffner Group in the development, manufacturing and marketing of high-performance


    Original
    PDF

    point of common coupling

    Abstract: passive harmonic filters
    Text: ECOsine juLy 2008 ECOsineā„¢ Advanced Passive Harmonic Filters www.myecosine.com  ECOsineā„¢ schaffner Group Schaffner is the international leader in the fields of electromagnetic compatibility and power quality, supplying components that support the efficient and reliable use of electric energy. Customers benefit from the technological know-how of the Schaffner Group in the development, manufacturing and marketing of high-performance


    Original
    690-888B point of common coupling passive harmonic filters PDF

    Schaffner Best EMC manual

    Abstract: T203 DIODE
    Text: DATASHEET High Power Line FN 3410 High Power ECOsine high power passive harmonic filter modules for system integration Modular and highly compact filter concept Cost-effective open panel design for cabinet integration Approvals Optimized for motor drives with DC-link chokes


    Original
    IEEE-519, Schaffner Best EMC manual T203 DIODE PDF

    Untitled

    Abstract: No abstract text available
    Text: DATASHEET EV/EH series Common-mode Suppression Chokes Rated currents up to 5 A Broadband attenuation characteristics Approvals Low magnetic leakage flux UL rated materials RoHS compliant Common-mode suppression chokes are mainly used to filter noise on AC power lines. Noise on


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: DATASHEET EMC/EMI Chokes RB series Current-compensated Chokes Rated currents from 16 to 50 A Up to 600 VAC or 1000 VDC Approvals 2- and 3-wire configurations Horizontal and vertical PCB mounting types Ruggedized saturation and thermal behavior Open construction for forced and convection


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Common-mode Suppression Chokes EV/EH series Rated currents up to 5 A Broadband attenuation characteristics Approvals Low magnetic leakage flux UL rated materials RoHS compliant Common-mode suppression chokes are mainly used to filter noise on AC power lines. Noise on


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Current-compensated Chokes EMC/EMI Chokes RB series Rated currents from 16 to 50 A Up to 600 VAC or 1000 VDC Approvals 2- and 3-wire configurations Horizontal and vertical PCB mounting types Ruggedized saturation and thermal behavior Open construction for forced and convection


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Common-mode Suppression Chokes EV/EH series Rated currents up to 5 A Broadband attenuation characteristics Approvals Low magnetic leakage flux UL rated materials RoHS compliant Common-mode suppression chokes are mainly used to filter noise on AC power lines. Noise on


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: EMC/EMI Chokes RB series Current-compensated Chokes Rated currents from 16 to 50A Up to 600VAC or 1000VDC Approvals 2- and 3-wire configurations Horizontal and vertical PCB mounting types Ruggedized saturation and thermal behavior Open construction for forced and


    Original
    600VAC 1000VDC C/230V Mil-HB-217F) PDF

    Untitled

    Abstract: No abstract text available
    Text: EMC/EMI Chokes RB series Current-compensated Chokes Rated currents from 16 to 50A Up to 600VAC or 1000VDC Approvals 2- and 3-wire configurations Horizontal and vertical PCB mounting types Ruggedized saturation and thermal behavior Open construction for forced and


    Original
    600VAC 1000VDC C/230V Mil-HB-217F) 400Hz convect76185 PDF

    Untitled

    Abstract: No abstract text available
    Text: EMC/EMI Chokes RB series Current-compensated Chokes Rated currents from 16 to 50A Up to 600VAC or 1000VDC Approvals 2- and 3-wire configurations Horizontal and vertical PCB mounting types Ruggedized saturation and thermal behavior Open construction for forced and


    Original
    600VAC 1000VDC C/230V Mil-HB-217F) 400Hz convect76185 PDF

    Untitled

    Abstract: No abstract text available
    Text: DATASHEET High Power Line FN 3410 High Power ECOsine high power passive harmonic filter modules for system integration Modular and highly compact filter concept Cost-effective open panel design for cabinet integration Approvals Optimized for motor drives with DC-link chokes


    Original
    IEEE-519, PDF

    Untitled

    Abstract: No abstract text available
    Text: Saturating Chokes EMC/EMI Chokes RI series Rated currents from 1.5 to 25 A Up to 500 VAC operating voltage Approvals DC to 1 kHz frequency Single or dual-choke configurations RI saturating type chokes change impedance at the moment of switching, and can be used to attenuate


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Saturating Chokes EMC/EMI Chokes RI series Rated currents from 1.5 to 25 A Up to 500 VAC operating voltage Approvals DC to 1 kHz frequency Single or dual-choke configurations RI saturating type chokes change impedance at the moment of switching, and can be used to attenuate


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Current-compensated Chokes EMC/EMI Chokes RB series Rated currents from 16 to 50 A Up to 600 VAC or 1000 VDC Approvals 2- and 3-wire configurations Horizontal and vertical PCB mounting types Ruggedized saturation and thermal behavior Open construction for forced and convection


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Common-mode Suppression Chokes EV/EH series Rated currents up to 5 A Broadband attenuation characteristics Approvals Low magnetic leakage flux UL rated materials RoHS compliant Common-mode suppression chokes are mainly used to filter noise on AC power lines. Noise on


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: DATASHEET EV/EH series Common-mode Suppression Chokes Rated currents up to 5 A Broadband attenuation characteristics Approvals Low magnetic leakage flux UL rated materials RoHS compliant Common-mode suppression chokes are mainly used to filter noise on AC power lines. Noise on


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: EMC/EMI Products EMC/EMI Chokes RB Series Current-compensated Chokes I I I I Rated currents from 16 to 50 A Up to 600 VAC or 1000 VDC 2- and 3-wire configurations Horizontal and vertical PCB mounting types I Ruggedized saturation and thermal behavior I Open construction for forced and


    Original
    Mil-HB-217F) PDF

    CIRCUIT DIAGRAM UPS imax

    Abstract: No abstract text available
    Text: EMC/EMI Products EMC/EMI Chokes RB Series Current-compensated Chokes I I I I Rated currents from 16 to 50 A Up to 600 VAC or 1000 VDC 2- and 3-wire configurations Horizontal and vertical PCB mounting types I Ruggedized saturation and thermal behavior I Open construction for forced and


    Original
    Mil-HB-217F) CIRCUIT DIAGRAM UPS imax PDF

    Untitled

    Abstract: No abstract text available
    Text: RFI suppression Chokes EV/EH series Common-mode Suppression Chokes n Rated currents up to 5A Broadband attenuation characteristics n Low magnetic leakage flux n UL rated materials n RoHS compliant n Typical electrical schematic Technical specifications Maximum continuous operating voltage:


    Original
    250VAC 400Hz 3000VAC, PDF

    Untitled

    Abstract: No abstract text available
    Text: Current-compensated Chokes EMC/EMI Chokes RB series Rated currents from 16 to 50 A Up to 600 VAC or 1000 VDC Approvals 2- and 3-wire configurations Horizontal and vertical PCB mounting types Ruggedized saturation and thermal behavior Open construction for forced and convection


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Current-compensated Chokes EMC/EMI Chokes RB series Rated currents from 16 to 50 A Up to 600 VAC or 1000 VDC Approvals 2- and 3-wire configurations Horizontal and vertical PCB mounting types Ruggedized saturation and thermal behavior Open construction for forced and convection


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: EMC/EMI Chokes RI series Saturating Chokes Rated currents from 1.5 to 25A Up to 500VAC operating voltage Approvals DC to 1kHz frequency Single or dual-choke configurations Technical specifications and/or winding-to-inserts: Flammability corresponding to: High potential test voltage:


    Original
    500VAC C/230V Mil-HB-217F) 10msec: 500VAC 2500VAC, PDF

    Untitled

    Abstract: No abstract text available
    Text: EMC/EMI Chokes RI series Saturating Chokes Rated currents from 1.5 to 25A Up to 500VAC operating voltage Approvals DC to 1kHz frequency Single or dual-choke configurations Technical specifications and/or winding-to-inserts: Flammability corresponding to: High potential test voltage:


    Original
    500VAC C/230V Mil-HB-217F) 10msec: a76185 PDF